EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

Similar documents
Option X4 Additional Operator Panel AOP-2 Description of option Functional description

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

DEIF A/S. Description of options. Option C2, Generator add-on protection package Automatic Gen-set Controller. Description of option

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

Genset Controller Unit Model EMS - GC10. Installation Manual Section

Option P1 Event and alarm printer Description of option Functional description Parameter list

APPLICATION NOTES H-coupling

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

MULTI-LINE 2 DESCRIPTION OF OPTIONS

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Genset control and protection with safety system

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Option H8.x and H12.x External I/O modules Description of option Functional description

Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

APPLICATION NOTES Translations

PS/IO Circuit Board Retrofit

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

MULTI-LINE 2 APPLICATION NOTES

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

Advanced Graphical Interface, AGI 100

Inverter Interface Interface examples Wiring examples Communication topology

Differential Liquid/Gas Pressure Transmitter

Getting started - USW 3.x Software download from internet Software installation Device setup Data backup

QUICK START GUIDE Generator Protection Unit GPU 300

INSTALLATION INSTRUCTIONS

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide

EX-RC1 Remote I/O Adapter

Instruction Sheet Board Style Low Water Cutoff

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

Model 7705 Control Module

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

EX-RC1 Remote I/O Adapter

UniStream CPU-for-Panel

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

APPLICATION NOTES DELOMATIC 4, DM-4 GAS/HYDRO

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

crio PN Installation Instructions V0.2/ COMSOFT

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

EX-RC1 Remote I/O Adapter

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

QUICK START GUIDE Paralleling and Protection Unit PPU 300

QUICK START GUIDE Paralleling and Protection Unit PPU 300

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

PV Rapid Shutdown device

PowerLogic High Density Metering System 1-Meter Enclosure

Installation Instructions & User Manual

Digital ac/dc (24V) Input Module

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

DSE2548 LED expansion module INTRODUCTION

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

270 MHz Control Modules

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Installation Instructions

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

A1. Multilin EPM 4600 Meter Displays DIS3500/DIS5700. Quick Start Guide. GE Digital Energy

Analog Input Installation Manual

T3 Interface Converters

Analog Output Module. ST-4xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

P216 Series Condenser Fan Speed Controller

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

2016 MacroAir Technologies Toll Free: Fax:

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Electrical network protection Sepam series 20 Sepam series 40 Quick start

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

DATA SHEET IOM 200 analogue interface for AGC 200

User s Manual Pulse Encoder Interface Module OTAC-01

Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring

Option H3 Serial communication Profibus DP

High Speed Remote I/O Module

Kinetix 6000 Axis Module and Shunt Module

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Vision OPLC V TR6/V350-J-TR6

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

DF PROFINET IO CPCI. Installation Instructions V1.3/ KUNBUS

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide

Analog Monitor Installation Manual

MAXIMA+ Series Rotary Level Indicator

24/48/120 VAC Interface Card Instruction Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

AGC 200 Advanced Gen-set Controller DATA SHEET

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Transcription:

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL r.0454a PM084 Rev 0 08/06/20 9087A 198 th Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology.com www.thomsontechnology.com

CONTENTS 1. WARNINGS AND LEGAL INFORMATION...1 LEGAL INFORMATION AND RESPONSIBILITY...1 ELECTROSTATIC DISCHARGE AWARENESS...1 SAFETY ISSUES...1 FACTORY SETTINGS...1 DEFINITIONS...1 2. DESCRIPTION...2 REAR VIEW...2 3. INSTRUCTIONS...3 FRONT VIEW...3 INSTALLATION:...3 WIRING...4 ERROR HANDLING...5

1. WARNINGS AND LEGAL INFORMATION Legal information and responsibility Thomson Technology takes no responsibility for installation or operation of the engine set. If there is any doubt about how to install or operate the engine controlled by the unit, the company responsible for the installation or the operation of the set must be contacted. The EAP 300 must be installed in accordance with the NEC (United States) or the CEC (Canada) standards. Electrostatic discharge awareness Sufficient care must be taken to protect the terminals against static discharges during the installation. Once the unit is installed and connected, these precautions are no longer necessary. Safety issues Installing the unit implies work with dangerous currents and voltages. Therefore, the installation should only be carried out by authorized personnel who understand the risks involved in working with live electrical equipment. Be aware of the hazardous live currents and voltages. Do not touch any AC measurement inputs as this could lead to injury or death. Factory settings The unit is delivered with certain factory settings. Given the fact that these settings are based on average values, they are not necessarily the correct settings for matching the individual engine. Thus precautions must be taken to check the settings before running the engine. Definitions Throughout this document a number of notes and warnings will be presented. To ensure that these are noticed, they will be highlighted in order to separate them from the general text. Notes NOTE: The notes provide general information, which will be helpful for the reader to bear in mind. Warning The warnings indicate a potentially dangerous situation, which could result in death, personal injury or damaged equipment, if certain guidelines are not followed. 1

2. DESCRIPTION The annunciator panel (EAP 300) which can be connected to the MEC 310 via a CANbus communication line. The EAP 300 has 16 configurable LEDs and 8 configurable buttons, which are programmed with the TPS 300 PC utility software. It can be used as an interface to the MEC 310 for indication of status and alarms together with buttons for e.g. remote alarm acknowledge and mode selection. Contents: A DC/DC converter for the EAP 300 DC supply voltage and cable with an RJ12 plug in one end and stripped wires in the other end is included in the EAP 300 Kit. NOTE: A maximum of 2 EAP 300 units can be connected to each MEC 310. NOTE: The maximum length of the CANbus line is 200m. REAR VIEW EAP 300 Connectors: CAN 1: DC supply (input) and CANbus communication to/from MEC 310 or other EAP 300 units. CAN 2: CANbus communication to/from other MEC 310 or EAP 300 units and status relay output. End resistor: Dip switch for 120 Ω end resistor for the CANbus communication. Dip switch 2 is not used Torque: 4 lb-in 2

3. INSTRUCTIONS FRONT VIEW: The configurable LEDs are named 1 to 16. Buttons are named 1 to 8. INSTALLATION: Mount on a flat surface of a Type 1 Enclosure. Note the maximum ambient temperature rating is 60 o C Panel Cut-out Detail: Dimensions in millimetres ( 1 inch = 25.4 mm ) 3

Wiring MEC 310 EAP 300 End resistor CAN L CAN H 59 57 OFF ON 2 1 CAN 1 CAN 2 R=120 Ω Gr Ye ee llo Bl Bl n w ue ac k W hit e Gr Ye ee llo Bl Bl n w ue ac k W hit Re e d Cable shield +5 0 VD VD C C Comm. to other units N Co O m mo n N C Status relay End resistor: The 120 Ω end resistor on the MEC 310 is needed at all times. The default setting of the end resistor on the EAP 300 panel is ON. Thus, the dip switch is at the right position if only one EAP 300 is connected. If there are two EAP 300 s connected, the end resistor of the EAP 300 with a connector plug in both CAN 1 and CAN 2 must be switched off. 1 unit connected: Dip switch no. 1 on the unit should be set to ON. 2 units connected: Dip switch no. 1 on EAP 300 no. 1 should be set to OFF and dip switch no. 1 on EAP 300 no. 2 should be set to ON. WIRE TYPE NOTES: Wire Size 30-12 AWG copper conductors (60-70 o C) The cable between the terminal blocks should be shielded twisted pair (Belden 9841 or equivalent) The maximum length of CANbus line is 200m. 4

CAN ID configuration The CAN ID for the EAP 300 can be changed by the following procedure: 1. Push-button no. 7 and no. 8 at the same time to activate the CAN ID change menu, this will activate the LED for the present CAN ID number, and LED no. 16 will be flashing. 2. Use button no. 7 (increase) and button no. 8 (decrease) to change the CAN ID according to the table below. 3. Press button no. 6 to save the CAN ID and return to normal operation. Selection of CAN ID: CAN ID Indication of CAN ID selection 0 CANbus OFF: LED 16 flashes 1 LED 1 light steady + LED 16 flashes (default value) 2 LED 2 light steady + LED 16 flashes Status relay The status relay will activate approximately 5 sec. after power up. Programming The programming of the EAP 300 is accomplished through the TPS 300 programming software. Error handling Duplicate CAN ID If two units on the CANbus have the same CAN ID, LED no. 1 to 4 will flash quickly. In this case press button no. 6 to jump into the CAN ID change menu and select another CAN ID for the unit. NOTE: The EAP 300 can be used with the supported CANbus Expansion I/O modules. 5