TEX-ICC400 Ethernet. Ethernet. TEX-ICC400 Ethernet. Configuration of TEX-ICC400 Serial Options -1- ASCII. Modbus/TCP ASCII.

Similar documents
NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

Texmate Ethernet Supplement NZ216 Revision

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

USB Server User Manual

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

RemLynx Remote Windows Computer Software 5073RemLynx DCN-M408

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Redirector User Guide

CMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1

ETOR-4 Ethernet/Serial Gateway ETOR-4. Ethernet/Serial Gateway USER MANUAL

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

MES1A, MES1B. Modbus TCP to Modbus ASCII/RTU Converters

ETOR-4. Ethernet/Serial Gateway USER MANUAL

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

MCS-Spectrum. Tactile Colorist Control Surface. Users Manual

62532 (EN649) Ethernet Adapter

All the registered trademarks referred to this manual are belonging to their respective companies.

PCMCIA Flash Card User Guide

Zodiac WX QUICK START GUIDE

Alexandria Network Printer

SmartStack SAE J1939 Communication Module

Operating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World!

Firmware Updates Model 24 / 44 / 42 Cryogenic Temperature Controllers

SureCross DX80 Network Basics A Guide to SureCross Networks Table of Contents

Gateway Module Programmable in C

Ethernet HMi RAC and Gateway Setup Instructions Rev. 09

REMOTE FRONT PANEL EMULATION

MODBUS MANUAL For the AccUView UV Transmission Monitor

SmartStack SAE J1939 Communication Module

RTU32 Update Tool. RTU32x Series Remote Update Tool. User Guide Version 1.01,

rbox610 Series Robust Din-rail Fanless Embedded System Web Configuration and App Software User s Manual

NETRS232 Series Quick Installation & Advanced Features Guide

SOFTWARE VERSION 3.3. CD P/N Rev. C

HDR-8X8-Plus. User Manual. HDMI 4K 8x8 Switch Matrix Connect up to eight different HDMI video sources to eight different outputs.

installation manual SALES AND ADMINISTRATION (toll free)

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

InLinK HM Setup Software Installation & Operation Manual

RTP-100 Technical Configuration

Product Release Information

Table of Contents. User Manual. DS-201 Solar Web Monitor

Universal Switch Panel USP-KEYSERVER. User Manual

User Guide. IPico Integrated Access Device

Modbus TCP/IP Option Instruction Manual

8 TS4-DDH T i g e r S t o p M a n u a l D a t a D o w n l o a d i n g. May 2006 Version 3.5 ~ 4.72 Hardware

Surround Panner. for Avid Pro Tools HD. Users Manual

Dynalink RTA020 ADSL Router Quick Set Up Guide

CONTROLweb TM. 3U Modular I/O. User Manual

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

TITLE: Device Server Configuration/Installation Manual

ST600-KIPRO User Manual

Serial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606

hyperion ! This device requires a downloaded phone app in Instruction Manual Data Transfer Module

Data-Tronix DT-HDVD-M2MLT-ENC DT-HDVD-M2MLT-RX. H.264 HDMI video Encoder and. H.264 HDMI video Decoder. User Manual. 15 Version: V1.0.

Manual ServiceGate. Remote Engineer B.V. De Parse 11, 8491 PJ, Akkrum The Netherlands

Secure Com Port Redirector User Guide

PDA-CAN Bridge. Version 1.0. LXNAV d.o.o. Kidričeva 24, 3000 Celje, Slovenia tel fax

USB-A to Serial Cable

User Manual Revision English

tsh-700 Series User Manual

GENERATOR BACKUP Web Server

Industrial Serial Device Server

SD1306. Speed Dome IP Camera. Quick User Guide

8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH

Quick Start Setup Guide

User Manual Revision English

FastForward User Guide

User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

pakedgedevice&software inc.

POWERLINK QUICK START MANUAL V2.8

Customer Support: For more information or support, please visit or at Product Release Information...

FastForward TM User Guide

NetBiter Serial Server User Manual

CAN Fiber Optic Modem

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

cb 1500 quick start guide & user manual Time and Attendance Made Simple...

Y K Modem Module

PA-SIP PAGING SWITCH. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

TABLE OF CONTENTS ABOUT THIS GUIDE... 4

SMG-1100/6100 User s Manual

User Manual A08. User Manual

1. SELECTING NEW PROTOCOLS

Flex Gateway Card. Installation and Operation Manual. For CPS 50kW/60kW 3-Phase String Inverters

Endura NSM5200 Series

BFR3000 Modbus Router

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

D-Link DI-804V. Broadband VPN Router. Manual. Rev Building Networks for People

Bluetooth USB User Guide. Revision A July 12, 2006 Part Number GC

TALKBACK INTERCOM SYSTEM V-2926 OPTION BOARD

SmartLog X 3 TEAM Basic Software Installation and Operation Instructions

62533 Ethernet Adapter

APPLICATION NOTE # 036

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

UPS COMMUNICATION Web Card

Seanet System Serial Barometer Interface. Supplement

WEB NODE INSTALLATION & OPERATION MANUAL

6001TA Terminal Adapter Installation Instructions

INDUSTRIAL ETHERNET MODULE TBOX Manual

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

If WPA-PSK is selected, please set the PSK key in the pass phrase field. The pass phrase should be 8 characters at least.

Transcription:

TEX-ICC400 Ethernet TEX-ICC400 Ethernet The TEX-ICC400 series controllers are available with two Ethernet options for Com port 1. They can be supplied with an ASCII Ethernet interface or with a Modbus/TCP Ethernet interface. ASCII The ASCII Ethernet option allows the TEX-ICC400 controller to communicate over a local or wireless area network using the Texmate ASCII communication protocol. This protocol is included in all of Texmate s development tools, and allows the TEX-ICC400 to be accessed from the the Texmate Development System (TDS), the Texmate Configuration Utility and the Texmate Data Viewer. Modbus/TCP The Modbus/TCP Ethernet option allows the TEX-ICC400 controller to communicate as a slave or master over a local or wireless area network using the industry standard Modbus protocol. This protocol is included in the Texmate Configuration Utility and the Texmate Data Viewer. (NB: The TDS does not include a Modbus communication option). In order for the TEX-ICC400 to operate correctly with any of the above Ethernet options, both of the TEX-ICC400 s serial and network options must be correctly configured, Configuration of TEX-ICC400 Serial Options ASCII When using the ASCII Ethernet option the serial operating mode for Com port 1 should be set to E_NET (mode 4) and the controller address should be set to match the address value used in the Texmate Configuration Utility or the Texmate Data Viewer application. Modbus/TCP When using the Modbus/TCP Ethernet option the serial operating mode for Com port 1-1-

should be set to MODBUS for a Modbus RTU slave (mode 1) or MB_MST for Modbus RTU master (mode 7). Recommended baudrate settings are 115,200 baud, no parity, transmit delay=2ms. The controller address should be set appropriately for the Modbus network. Serial options can be configured by one of the following methods: Keypad Display If your TEX-ICC400 has been supplied with the LED or LCD keypad/display option then you can check the serial options as follows: A. Press the P and buttons together. B. Press the P button until the display shows CAL. C. Using the and buttons adjust the Cal value to 201 and then press P. D. Using the and buttons change the mode to E_NET if you are using the ASCII Ethernet option or to MODBUS (Modbus slave) or MB_MST (Modbus master) if you are using the Modbus/TCP Ethernet option. E. Use the P and / buttons to edit the following serial parameters as specified above. F. When finished set CAL back to 000 and then keep pressing the P button to exit the setup mode and return to the normal display (or press the P and buttons together to quickly exit the setup mode). Texmate Configuration Utility Use the standard Texmate serial cable to connect the serial port of your PC to com port 2 on the TEX-ICC400. (Make sure that com port 2 on the TEX-ICC400 is set to the default mode of ASCII, 115,200 baud, no parity). A. Run the Texmate Conifugration Utility application on your PC. B. Open a new connection to the TEX-ICC400 controller. (Download the Texmate Configuration Utility Quick-start Guide for more info. at: www.texmate.co.nz). C. Click on the Meter button in the tool bar and select the Change meter comm. settings option as shown below. D. Click on the Mode options for port 1 and select either Ethernet, MODBUS, or MODBUS Master as required. (Note: In older versions of the Texmate Configuration Utility, the Ethernet option is shown as a hyphen - ). Set up the serial address of the controller to the desired address and then click OK. -2-

Macro Configuration For advanced users, the serial port can also be configured by embedding commands into the macro source file. The following lines should be included: mem &SERIAL_MODE1=4 mem &SERIAL_ADDRESS1=1 mem &BAUDRATE1=7 //1=Modbus slave, 4= ASCII Ethernet, 7=Modbus master // 115200 baud, no parity, 2mS Tx delay Ethernet Configuration of Network Options The network options can only be configured via the network TCP connection. They cannot be configured from the TEX-ICC400 directly or from any of the other Texmate development tools. To help you configure the network options a free program called Device Installer is available for download from Lantronix: http://www.lantronix.com/device-networking/utilities-tools/device-installer.html Once you have installed the Device Installer application, connect the TEX-ICC400 controller to the Ethernet network and turn it on. When you run the device installer application, it will immediately start searching the network for any connected devices and display the ones that it finds as shown below. NOTE: All TEX-ICC400 s with Ethernet are DHCP enabled by default - this allows the server to resolve an IP adddress for the device. If you change the IP address from a dynamic address to a fixed address, it may become undetectable on the network if the IP address or subnet mask do not match those of your current network. Configuration of the ASCII Ethernet Option If you are using the ASCII ethernet option, click on the IP address of the device shown in the left frame. Then select the Web Configuration tab at the top of the right frame as shown overleaf. -3-

Click the green Go button (see above). When the dialog box pictured on the right is displayed, you may choose to either click OK to enter directly, or select your own custom username and password. Click on Serial Settings and set up the configuration options as shown below. After changing the configuration settings to the correct values, scroll down to the bottom of the page and click the OK button. As shown overleaf, the message Done! -4-

appears next to the OK button to verify that the changes have been accepted. Ethernet Save the new settings to memory by clicking on the Apply Settings button in the lefthand menu. When you do this the ethernet port will reboot and take several seconds to reappear, as shown below. For most standard networks the other configuration settings can be left at their default values. Do not change any other settings unless you are an experienced user of TCP/IP networks. If you can connect to the IP address, but can t talk to the TEX-ICC400, (or if you want to start again), simply click on Apply Factory Defaults and repeat the setup for the Serial Settings as shown above. Advanced users can also use other serial modes in the TEX-ICC400 with the ASCII Ethernet option. For example, the standard ASCII mode (mode 0), the macro master mode (mode 2) and the print mode (mode 3) can also be used. When using these modes of operation, ensure that the serial settings in the Ethernet port match the serial settings in the TEX-ICC400. Depending on the protocol you are using, you may also have to disable or modify the Packing Control section in the Serial Settings window. In most cases the ASCII ethernet port will receive incoming connections to allow an external client to read or control the TEX-ICC400, however it is also possible to make outgoing connections to a remote server. This allows an exchange with an http or SMTP server for email. To do this, the ASCII ethernet port needs be set to modem mode in the Connection -5-

window. The TEX-ICC400 does not include any built-in support for these features, and operation in these modes will always require the appropriate macro to be loaded into the TEX-ICC400. Please contact Texmate NZ to enquire about the range of macros that are currently available. For more help with ASCII Ethernet advanced features, please go to www. lantronix.com/support/documentation.html and download the Xport User Guide. Modbus/TCP Option If you are using the Modbus/TCP ethernet option, click on the IP address of the device shown in the left frame of the device installer window. Then select the Telnet Configuration tab at the top of the right frame. (Modbus/TCP versions do not have a web browser for configuration setup). Click on the connect button at the top of the window and you should see the following text appear: Press the Enter key on your keyboard and the screen should now display all of the available configuration options, as shown below. -6-

A brief summary of the configuration setup is shown in the diagram on p.6. Parameters in any of the above sections can be changed by entering a number from 1-4 and then working through the menu options as they are presented. Press the Enter key to retain the current parameter value (shown in braces), or enter a new value for the parameter and then press enter. Ethernet Section 1 allows you to change the IP addresses. The default IP address should be set to 0.0.0.0 which selects the DHCP mode, enabling your network server to allocate an IP address automatically. Section 2 allows you to set the operating mode and serial settings. The Slave/Master option for the Ethernet port must match the TEX-ICC400 s serial mode setting for port 1 (see p.1-3 section on TEX-ICC400 Serial Options ). If you are operating the TEX-ICC400 as a Modbus slave, then you should also select Slave (or if the TEX-ICC400 is set to operate as a Modbus master then you should select master) for the Etherenet port as well. The operating mode should always be set Modbus/RTU mode (the TEX-ICC400 only operates in RTU mode). The serial setings should be set to 115,200 baud, 8 data bits, no parity, 1 stop bit. Please note that these parameters should also match the TEX-ICC400 serial options for port 1 (as described in Section D of the configurtaion utility instructions on p.2). It is possible to use different settings if required, but these settings have been chosen to give maximum through-put and are recommended. The interface type parameter should always be set to RS232. Section 3 provides options which are not available with the TEX-ICC400, so it can be ignored. Section 4 provides advanced options for the Modbus protocol. Unless you are an advanced user and have experience with the Modbus protocol, we recommend that you use the default settings for this section. If you do change any parameters in this section, you can always return to the default settings by pressing D at the main menu screen. Section 5 is only available when Modbus master mode has been selected. This section allows the standard 8-bit Modbus slave addresses to be converted to 32-bit IP addresses for use with the Modbus/TCP network via a lookup table. The following section has been recreated from the Modbus/TCP users guide to explain this in more detail. Since serial Modbus uses 8-bit slave addresses and a TCP/IP network requires 32-bit IP addresses, the Device Server uses this table to map an 8-bit address into an IP/ Unit ID combination. The 8-bit address is used to both select the desired IP and as the Unit ID sent. The table holds 8 entries, and any Modbus slave address not found in the table returns an exception response to the master (if enabled). Overleaf is an example of adding an entry. Select 5 to edit/view settings. -7-

Close Idle TCP sockets after (3-60 sec, 0=leave open) (10) Redundant entry retries after (15-60 sec. 0=disable feature) (0) (Set 4th octet to 0 to use Slave Address as part of IP) 1): 001-100: 192.168.000.000+SLV 2): 101-199: 192.168.000.150 A)dd, D)elete, E)xit - select function A Modbus addr from (102) Modbus addr to (102) 255 Slave IP address (192) 172.(168) 16.(000) 123.(000) 1): 001-100: 192.168.000.000+SLV 2): 101-199: 192.168.000.050 3): 200-255: 172.016.123.000+SLV A)dd, D)elete, E)xit - select function These options are only relevant in Modbus master mode and once again we recommend that only advanced Modbus users change these settings from the default values. Notes Warranty: Texmate warrants that its products are free from defects in material and workmanship under normal use and service for a period of one year from date of shipment. Texmate s obligations under this warranty are limited to replacement or repair, at its option, at its factory, of any of the products which shall, within the applicable period after shipment, be returned to Texmate s facility, transportation charges pre-paid, and which are, after examination, disclosed to the satisfaction of Texmate to be thus defective. The warranty shall not apply to any equipment which shall have been repaired or altered, except by Texmate, or which shall have been subjected to misuse, negligence or accident. In no case shall Texmate s liability exceed the original purchase price. The aforementioned provisions do not extend the original warranty period of any product which has been either repaired or replaced by Texmate. Ph: +64-9-835-1550 Fax: +64-9-835-1250 DOCUMENT REVISION CODE: Unit 2, 10 Canaveral Drive, Albany, North Shore City 0632 New Zealand Email: info@texmate.co.nz www.texmate.co.nz ICCETH-MAN-07-V.01 User s Responsibility: We are pleased to offer suggestions on the use of our various products either by way of printed matter or through direct contact with our sales/application engineering staff. However, since we have no control over the use of our products once they are shipped, NO WARRANTY, WHETHER OF MERCHANTABILITY, FITNESS FOR PURPOSE OR OTHERWISE is made beyond repair, replacement, or refund of purchase price at the sole discretion of Texmate. Users shall determine the suitability of the product for the intended application before using, and the users assume all risk and liability whatsoever in connection therewith, regardless of any of our suggestions or statements as to application or construction. In no event shall Texmate s liability, in law or otherwise, be in excess of the purchase price of the product. Texmate cannot assume responsibility for any circuitry described. No circuit patent or software licenses are implied. Texmate reserves the right to change circuitry, operating software, specifications, and prices without notice at any time. Distributor: -8-