I/O module, digital outputs (open collector), modu551

Similar documents
I/O module, digital outputs (relays), modu550

I/O module, digital and universal inputs, modu530

I/O module, universal, digital, S0 inputs, modu533

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

I/O module, analogue outputs and universal inputs

modu : Local override and indicating units

EY-EM : Remote I/O module, ecolink

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit

EYE 200: DDC single-room controller, ecos200

EY-SU 358: Push-button unit for room operating unit, ecounit358

EY-RU : Room operating unit, ecounit

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

modunet292: novanet-ethernet interface

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

EY-AS 525: Modular automation station, modu525

EY-AS 524, 525: Modular automation station, modu524/525

EY-RU 355: Room operating unit, ecounit355

EY-AS 524, 525: Modular automation station, modu524/525

EY-RC 208, 209: Room automation stations, ecos208, 209

AVM 321, 322: Valve actuator

EY-RU : Room operating unit with EnOcean wireless technology, ecounit

EY-RU : Room operating unit with EnOcean wireless technology, ecounit

Sauter Systems

ecounit : Room operating unit with EnOcean wireless technology

AVF 125S: SUT valve actuator with spring return

Manual operation and local visualisation. with SAUTER EY-modulo.

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

EY-AS 521: Compact automation station, modu521

Status display unit with P-bus connection

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Products no longer available

Operating instructions. Speed monitor D / / 2014

AVM 105S, 115S: Valve actuator with SAUTER Universal Technology (SUT)

Products no longer available

TXM1.8RB. TX-I/O Blinds module

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Rotary version, three-position control

AVM321S, 322S: Actuator SAUTER vialoq AVM 1000 with SAUTER Universal Technology (SUT )

Resistance measuring module

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Operating Instructions

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

Operating instructions. Switching amplifier DN0210 DN / / 2015

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Extension module for lighting control

Power supply module, bus connection module

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Control D. Controller Module for Proportional Valve Control. Installation Manual

Technical data. Safety notes. Product features

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Product and functional description

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Digital input modules

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Ă„nderungen vorbehalten /02

Electrical Actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

EY-RC 500: Room automation station, ecos500

Content. Product Description

Switching module for AC V and up to three load stages, with manual switching

AB Axis Industries. Use

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

M-Bus Central Unit. Use

Room Temperature Controller

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Operating instructions. Standstill monitor A / / 2011

Temperature controller Ducted systems

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

OPERATING INSTRUCTIONS

IXXAT CME/PN. CANopen-PROFINET Gateway HARDWARE MANUAL ENGLISH

ERF910. RF Repeater. Synco living

Technical data sheets

Impulse switching module

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Room automation station

Mobile Data Collector

VersaMax IP I/O Module

s Spring return C / max C

Heating Circuit Controller

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

VersaPoint I/O Module

Non-communicating room controllers

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

SMARTSCAN INFORMATION

Super universal modules

Functional data Factory settings Variable Setting Torque Inhibiting torque

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Pneumatic positioning module contiuous kpa output signal, with manual operation

Transcription:

Product data sheet 92.056 EY-IO 551: I/O module, digital outputs (open collector), modu551 How energy efficiency is improved SAUTER EY-modulo 5 technology: modular, fast and universal Features Part of the SAUTER EY-modulo 5 system family 16 digital outputs Plug-in element for extending the modu525 automation station (AS) Power supply from modu525 AS Modular design (baseplate/electronics) Direct labelling on the front Can be equipped with a local operating and indicating unit EY-IO551F001 Technical data Power supply Power supply from modu525 AS via I/O bus Power consumption1) 0.7 VA/0.35 W Power loss 0.35 W Current consumption2) 30 ma Operating temperature 0...45 C Storage and transport temperature 25...70 C Admissible ambient humidity 10...85% rh, no condensation Digital outputs 16 Type of outputs Open collector, NO contacts (0-I) outputs switched with respect to ground Power supply for DO external, positive 24 V= Load 0.5 ma up to 100 ma Connection for modu6** 6-pin, integrated Connection, I/O bus 12-pin, integrated Connection terminals 24 (0.5...2.5 mm²) Fitting on top-hat rail Dimensions W x H x D 42 170 115 mm Weight 0.29 kg Type of protection IP 30 (EN 60529) Protection class I (EN 60730-1) Ambient conditions Inputs/outputs Interfaces and communication Construction Standards and directives CE conformity as per Environment class 3K3 (IEC 60721) EMC directive 2004/108/EC3) EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 Overview of types Type Properties EY-IO551F001 I/O module, digital outputs (open collector), modu551 1) 2) 3) On the primary side of modu525 base station (230 V~) Supply via modu525 base station EN 61000-6-2: In order to meet the European standard, the power cable should not exceed 30 metres in length. Right of amendment reserved 2015 Fr. Sauter AG 5.1 1/5

Accessories Type EY-LO630F001 EY-LO650F001 EY-LO650F002 Description 16-LED indication, bi-colour 6 switches, auto-0-i, 4 LEDs operation/indication 3 switches, auto-0-i-ii, 4 LEDs operation/indication 0920360003 24 V I/O module baseplate (pack of 3) 0929360551 Electronics module, modu551, 16 DO (OC) 24 V Description of operation The modu551 I/O module is used to activate actuators such as relays or displays of operational systems, e.g. in HVAC engineering. Intended use This product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product documents must also be adhered to. Changing or converting the product is not admissible. Engineering notes The modu551 I/O module is generally comprised of two components. The baseplate in which the I/O bus system and the connection terminals are integrated and the actual I/O module electronics. Fitting/assembly The baseplate of the I/O module is mounted in a cabinet using a top-hat rail (EN 60715) and connected on the side directly to the I/O bus of the modu525 AS or modules. This work must only be carried out in the de-energised state. The baseplate contains a bus module, which is responsible for power supply and continuous communication as well as the optional emergency power supply. This ensures that faults due to a failure or partial defect in the electronic component do not affect the function of other downstream modules. Removing/inserting the I/O module electronics from/to the baseplate is possible while the AS is in operation. To ensure plant safety and to avoid any faults at inputs or outputs, the I/O module electronics should only be removed or inserted while the base station is switched off. Labelling concept The I/O module can be labelled with a paper insert in the frontal transparent cap. There are specially perforated label sheets available for this purpose. The labelling is usually carried out using texts generated from CASE Suite, and the labels are printed on normal A4 paper using commercial printers. Assigning modules to AS The I/O module electronics are encoded on the hardware side using pin inserts so that only the appropriate baseplate can be used. The modu525 AS detects whether a module baseplate is plugged into the I/O bus. Baseplate number and assignment of module types for the I/O modules on the AS are defined with CASE Suite. This information is permanently stored in the AS. LED indicator/function The I/O module is equipped with a system LED that indicates the operating modes as follows: System LED LED I/O bus Status Indicator sequence Description No designation Continuous green Module in operation Outputs Pulsating green º º º º º º Module not assigned with the base station Rapid pulsating red ººººººººººººº AS in configuration, update or download Flashing red º º º º º º º º Module incorrectly assigned or internal error Alternating green red OFF ºº ºº ºº ºº ºº No indicator The I/O module has a total of 16 digital outputs Lamp test active (indicator type priority) No power supply 2/5 5.1 Right of amendment reserved 2015 Fr. Sauter AG

Number of outputs 16 Type of outputs Load on outputs Length of connecting cable Digital, transistor open collector Signal connected to ground/earth 24 V=, 0.5 ma up to 100 ma 30 m Processing cycle 100 ms Real feedback is only possible via digital inputs. The open collector outputs (OC) can be supplied with a maximum power supply of 24 V=; the signals are connected to ground. The plant devices are connected via screw terminals; this may only take place when the system is disconnected from the electrical supply. ) Note If it is mandatory to comply with the European standard (EN 61000-6-2), the connecting cables for the digital open collector outputs (DO-OC) must not be longer than 30 metres. Defined switching statuses in the event of a module defect are guaranteed by an independent internal cut-off facility. This prevents the outputs from flickering. The open collector outputs adopt the defined status 0 (Off): when the power supply/communication on the I/O bus is interrupted, or, when the AS power supply fails. All open collector outputs are equipped with protective switches. When connecting relays with integrated protection (e.g. freewheeling diode), you must ensure that the polarity is correct. Channel and terminal assignment Description modu551 Digital output Transistor open collector Channel Schematic Terminals DO GND 0 o0 1 1 o1 2 3 2 o2 4 5 3 o3 6 7 4 o4 8 9 5 o5 10 6 o6 11 7 o7 12 8 o8 13 9 o9 14 10 o10 15 16 11 o11 17 18 12 o12 19 20 13 o13 21 22 14 o14 23 15 o15 24 Connection of local operating unit The modu551 I/O module can be complemented with the modu630 local operating and indicating units (LOI) to allow actuated outputs to be displayed directly or be actuated directly by the modu650 local operating unit. The function corresponds to the standard EN ISO 16484-2:2004 for local override and indicating units. Two types are available: EY-LO650F001: 6 switches (automatic mode A, 0-I) with LED indicators EY-LO650F002: 3 switches (automatic mode A, 0-I-II) with LED indicators The local operating and indicating units can be installed and removed during operation (hot-pluggable) without affecting functions of the AS or I/O module. Detailed information about the actuation function and LED indicator can be found in the PDS 92.081 for EY-LO 6**. If an incompatible unit is connected, this status is indicated by the flashing of all LEDs (red and yellow); there is no risk of the I/O module being destroyed. Right of amendment reserved 2015 Fr. Sauter AG 5.1 3/5

92.056 Product data sheet ) Note Before inserting an indicating and operating unit, all switch positions (AUTO) must be checked to ensure that no undesired switching statuses are active. When the unit is removed, all outputs are operated with the automatic statuses of the I/O module. In accordance with the standard, the local override and indicating units allow restricted operation of system components without involvement of the AS planned for the application. Outputs in manual position may change their status briefly when the user program is downloading. The local operating unit can be used to actuate the channels 0...5 in the AS directly even without a user application (CASE Engine). Area of use EY-LO630F001 Single unit used for indication of the data points of the modu530 I/O or modu525 AS 16 LEDs EY-LO650F001 Single unit used for operation and indication of the data points of the modu550 I/O or modu525 AS 4 LEDs 6 switches with LED indicator Level Auto-0-I green indication Manual position indication yellow EY-LO650F002 Single unit used for operation and indication of the data points of the modu550 I/O or modu525 AS 4 LEDs 3 switches with LED indicator Level Auto-0-I-II green indication Manual position indication yellow Disposal When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. Connection diagram o0 o1 01 o2 03 02 o3 o4 05 04 o5 07 09 06 08 o6 o7 11 10 12 16 x OC Open Collectors 15 14 o8 o9 o10 4/5 17 16 19 18 o11 o12 23 21 20 22 o13 24 o14 o15 5.1 A10509 13 Right of amendment reserved 2015 Fr. Sauter AG

Dimension drawing 42 115 M11416 85 170 85 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-controls.com Right of amendment reserved 2015 Fr. Sauter AG 5.1 5/5