Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Similar documents
SolarEdge Quick Installation Guide North America

Replacing the Power Supply

SolarEdge Quick Installation Guide North America

Power Supply and Fan Module Installation

SolarEdge Quick Installation Guide North America

one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

SUN2000-(2KTL-5KTL)-L0. Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

SolarEdge. Distributed Solar Power Harvesting Systems. Installation of the SolarEdge System SolarEdge

About This Guide SolarEdge Installation Guide for Three Phase Inverters EU Version 1.5

SUN KTL-USH0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Firmware Update with SD Card SUNNY BOY WINDY BOY SUNNY TRIPOWER

Panduit Basic Rack PDU

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

VRp Three-Phase Precision AC Voltage Regulator

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TCNM-ACBB1 Installation Manual

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Recommended Practices for Installation For EC Directive 2004/108/EC Relating to EMC Supplement to Installation and Operating Manual

Mounting on the Ceiling Using Flush Mount (Face Down)

PowerLogic High Density Metering System 1-Meter Enclosure

OPLC Installation Guide

Standard Strip Series

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation manual plugs and connectors with screw connection (16/32 A)

sonnen Installation Practical

SolarEdge Installation Guide MAN Cover goes here (right-side [odd] page) hotovoltaikforum.co

Bulletin Installation of solar photovoltaic systems Rules , , , , and

Installation Notes TII Model 341 Protector

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

Panduit Basic Rack PDU with Local Meter

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Power supply module, bus connection module

SUN2000 (8KTL-28KTL) Quick Installation Guide. Issue: 14 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

Power Supply Installation

3RV1 Circuit-Breakers

SUN2000 (8KTL-28KTL) Quick Installation Guide. Issue: 13 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SAVE THESE INSTRUCTIONS

Installing the Camera

PV Rapid Shutdown device

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

High Speed Remote I/O Module

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

JAN 16 Rev B

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Thermal-Magnetic Circuit Breaker 2216-S

Flat Surfaced Ceiling Mounted Exterior Dome (Face Down) IN-DO2MIRVSLL, IN-DO4MF, IN-DO4M36A, IN-DO1MIRF, IN-DO2MIRF,

M215 Microinverter Installation Planning

Vision OPLC V TR6/V350-J-TR6

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

Installing the Cisco AS5400XM Universal Gateway

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

Installation Instructions

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Model Number Electrical Compatibility Module Connector Type M LL-S22 M LL-S22-NA M LL-S23 M LL-S23-NA

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

onlinecomponents.com

M215 (M215-60) Safety

Rack Installation Instructions

M250 (M LL) Safety

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

M215-Z Safety Information (M LL-IG-ZC)

User Manual. Solar Inverter for Water Pump

FP-PS-4. Features. Installation

FLEX Ex Spring Clamp Terminal Base

SUN KTL-M0 Quick Guide (Europe Edition) Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

V E2B Snap-in I/O Module

TXM1.8RB. TX-I/O Blinds module

BLUE 3 INSTALLATION GUIDE

The identified danger could cause physical and property damage.

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

Installing the Cisco 2524 and Cisco 2525 Routers

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

DeviceNet ArmorBlock Network Powered 16-input Module

Enphase S-Series Microinverter and Engage Cable Safety

MicroTech II TM Remote I/O Panel Installation Manual

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

UniStream HMI Panel. CPU-for-Panel

SUN KTL-US-HV-D0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

Installing a Power over Ethernet injector

IntelliLED TM. Controls: User Guide. Picture for DALI only. Wireless adds external antenna. NOTE: These parts are NOT user serviceable

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Transcription:

Three Phase Residential Solution for Australia, System Design and Installation Guidelines This document describes how to design and install SolarEdge three phase inverters for residential installations. Version History 1.0 - initial release 1.1 - modified design guidelines and figure 1. 1.2- changed pictures in the Design Guidelines section. 1

Design Guidelines To balance the system arrays, ensure that the system you are connecting is designed according to guidelines herein. No. of PV Arrays: 2 PV Array Length: 8*-25 power optimisers, max. 5,700kWp *7 when using P404/P405 power optimisers Max. Difference of PV Array Length: 2 modules Mix of Modules from Each Facet: In case of 2 facets - each array should include a similar mix of modules from each facet with a difference of up to 2 modules in total. Examples of Balancing Two PV Arrays* Arrays equal in length Mix of modules from each facet is identical Arrays differ in length by 2 modules Mix of modules from each facet is similar with a difference of 2 modules Arrays equal in length X Mix of modules from each facet is different by more than 2 (total of 8) Arrays differ in length by 1 module Mix of modules from each facet is similar with a difference of 1 module Arrays differ in length by 2 modules Mix of modules from each facet is similar with a difference of 2 modules Arrays differ in length by 1 module X Mix of modules from each facet is different by more than 2 (total of 3) * Blue modules represent the difference in the mix of modules from each facet. 2

The DC voltage displayed on the inverter refers to the internal inverter voltage. Connection Guidelines This section is a supplement to the SolarEdge Installation Guide version 3.1 (P/N MAN-01-00057-3.1: T53Uhttp://www.solaredge.com/sites/default/files/se-inverter-installation-guide.pdfU35T) It describes how to connect DC and AC cables to the DC Safety Unit via conduits (instead of cable glands and connectors), in SolarEdge three phase residential inverters for Australia. The SolarEdge DC Safety Unit is an integral part of the SolarEdge inverter and complies with AS/NZS 5033:2014. Do not install additional exetrnal PV array DC isolators adjacent to the inverter. The DC Safety Unit terminals are suitable for connection of copper conductors only. To open conduit knockouts: The conduit knockouts may be opened before or after mounting the inverter. 1 Turn OFF the following: The inverter ON/OFF switch The AC circuit breaker The DC Safety Unit The DC switch in the DC Safety Unit is mechanically interlocked with the front cover. Do not remove the cover unless the switch is in the OFF position. When the DC Saftey Unit is OFF it may be locked:hen the DC Saftey Unit is OFF (for example during maintenance) it may be locked: 1. Rotate the DC Saftey switch to the Lock position. 2. Insert the lock through the knob opening. 2 Loosen the screws on the front cover of the DC Safety Unit, as shown in Figure 2: Figure 1: Opening the DC Safety Unit 3 Remove the DC Safety Unit cover. The following figure shows an example of the internal components in the DC Safety Unit of a three phase residential inverter. Components may differ depending on inverter models. 3

Terminal blocks for DC connection (to the inverter) Figure 2: Inside the DC Safety Unit 4 Open the required AC and DC conduit knockouts according to the conduits used in the installation: The knockouts are located at the bottom and sides of the enclosure. Open the required knockouts two for the DC connections and one for the AC connection, taking care not to interfere with any of the internal components. A step drill bit may be used. Figure 3: DC Safety Unit knockouts Unused conduit openings should be sealed with appropriate seals. 5 Open the inverter cover: Release the Allen screws and carefully pull the cover towards you before lowering it. CAUTION! When removing the cover, make sure not to damage internal components. SolarEdge will not be held responsible for any components damaged as a result of incautious cover removal. To connect the AC Grid to the inverter via the DC Safety Unit: Use a five-wire (four core + earth) cable. The maximum wire size for the input terminal blocks is 16mm². 1 Strip 35 cm of the external cable insulation and strip 8-10mm of the internal wire insulation. Figure 4: Insulation stripping AC 2 Insert the AC conduit into the AC-side knockout that was opened. 4

3 Insert the AC cable through the conduit towards the AC terminals in the inverter. 4 Connect the AC wires as follows. Connect the PE (grounding) wire first. Wire type Connect to terminal Line 1 Line 2 Line 3 PE (grounding) L1 L2 L3 Neutral N Figure 5: Three Phase Inverter AC Terminals 5 Tighten the screws of each terminal with a torque of 1.2-1.5 N*m / 0.88-1.1 lb*ft. 6 Check that the wires are fully inserted and cannot be pulled out easily. 7 Verify that there are no unconnected wires to the inverter and that unused terminal screws are tightened. To connect the arrays to the DC Safety Unit: 1 Strip 8 mm of the DC wire insulation. 2 Insert the DC conduits into the DC-side knockouts that were opened. 3 Connect the DC wires according to the DC+ and DC- labels: Use a standard flat-blade screwdriver to connect the wires to the spring-clamp terminals as shown in Figure 7. The screwdriver blade should fit freely in the terminal opening. Too large a blade can crack the plastic housing. Insert the screwdriver and press the release mechanism and open the clamp. Insert the conductor into the round opening and remove the screwdriver the wire is automatically clamped. Ensure each array is conected to a different terminal block. 4 Verify that there are no unconnected wires. Figure 6:Spring-clamp terminals 5 Close the DC Safety Unit cover. Attach the cover and secure it by tightening the four screws with a torque of 1.2 N*m / 0.9 ft.*lb. 6 Ensure proper cable entry sealing: inspect the entire cable run and use standard sealants to avoid water penetration. 5

Mechanical Specifications Figure 8: Residential three phase inverter dimensions 6