Advanced Test Equipment Rentals ATEC (2832)

Similar documents
Sartorius Research. R 160 P Electronic Semi-Microbalance

Sartorius handy. H 160, H160 P. Electronic Precision Balance Installation and Operating Instruction

Sartorius XQ 6100, XQ 6100 B.

Sartorius MP8 Series Balances and Scales

Sartorius TS 6100B, TS 12 Electronic Over/Under Scales Installation and Operating Instructions

STANDARD OPERATING PROCEDURE ACB SERIES ACB-600H PRECISION BALANCE

Oxford E Series. Instruction Manual

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

Sartorius Comparator. Interface Description for the CC Model Series

CONTENTS. PRECAUTIONS Introduction Installation... 7

User Manual. Models: BL 303 BL 602 BL 2002 BL 3001 BL 6001 BL 30K1

MWP SERIES. High Precision

Sartorius CC30002, CC50002 Electronic Mass Comparator

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

Sartorius Basic plus. Electronic Semi-micro-, Analytical and Precision Balances Installation and Operating Instructions

Sartorius Element Series

ANALYTICAL / SEMI-MICRO BALANCES

INTRODUCTION INSTALLATION

Operating instructions METTLER TOLEDO BD balances

Sartorius Element Series

AL-Series Analytical and Toploading Balances

STANDARD OPERATING PROCEDURE AA SERIES AA-160 PRECISION BALANCE

Sartorius CP Gem plus Series

Sartorius Master pro Series. LP Models Electronic Precision Balances Operating Instructions

The all-new OHAUS EXPLORER. Intelligent. Intuitive. Ingeniously Practical.

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

Sartorius Economy Series Sartorius Express Series

1.0 Description. 2.0 Unpacking. 3.0 Installation

YJ Carat and Gold Scales

The all-new OHAUS EXPLORER. Intelligent. Intuitive. Ingeniously Practical.

ANALYTICAL/SEMI-MICRO BALANCES

Explorer Pro. The Ohaus Explorer Pro Series, the new standard for performance and value in laboratory balances!

GP SERIES GP-12K/GP-20K/GP-22K/GP-30K GP-40K/GP-60K/GP-100K/GP-102K GP-30KS/GP-100KS

Summit Series. Operation Manual Rev. A g. 0.0 g g TARE

Pro Analytical Balances

VA-6 kg, VA-12 kg, VA-30 kg

IDS-801 Series Compact Bench Counting Scale. User Manual

BBA-Series Precision Balances

PLATINUM PRO1001DXP DIGITAL COUNTERTOP / PORTABLE BALANCE

GX-K series. GF-K series

Sartorius Research Series

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

The OHAUS Explorer Pro Series, the new standard for performance and value in laboratory balances!

The New Sartorius CP-Series

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Introduction BALANCES. Laboratory Balances. Appearance Color Physical Properties Balances. Technical Service Index

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

Visit for discount prices on Acculab Scales SVI SERIES PROFESSIONAL PRECISION INDUSTRIAL SCALE SVI-10A SVI-20B SVI-50C SVI-100E SVI-200F

NB/NHB Precision Balance

Pioneer. Analytical and Precision Balances

Ingeniously Practical. Adventurer Product Replacement Cross Reference Analytical and Precision Balances. Adventurer Pro to New Adventurer AX

The Only Scale in its Class with Touchless Sensors That Free Up Your Hands!

Analytical and Precision Balances Precision Bench and Floor Scales. Weigh the Difference

Sartorius Counting Scales CB Models Electronic Precision Scales

Explorer. Analytical and Precision Balances. Features Include:

QB Series. Operation Manual. Precision Balance. To be the best by every measure

Adventurer TM Balances Instruction Manual

Analytical Balance GH-120 GH-200 GH-300 GH-202 GH-252 1WMPD C

Model Bulk Sampling Scale. User s Manual

GX-200/GX-300/GX-400 GX-600/GX-800/GX-1000 GX-2000/GX-3000/GX-4000/GX-6100 GX-6000/GX-8000

Analytical Balance BM-20 BM-22 BM-252 BM-200 BM-300 BM-500

The New Practum. Start Weighing Right.

The Sartorius Talent Series Your access to talented weighing technology

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

Sartorius Talent Sartorius Gem, Gold Electronic Analytical and Precision Balances and Precious Metal Scales

Precision Balance W3200 Series Operating Manual

EHC-WF. User/Technical Manual. Contents subject to change without notice

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Sartorius Master pro Series

Navigator. The Only Scale in its Class with Touchless Sensors That Free Up Your Hands! Portable Scales. Standard Features Include:

Precision balance with Graphic display. User Manual

Adventurer TM Pro Analytical and Precision Balances

Operating Instructions. ALC Models. Electronic Analytical Balances and Precision Scales

GF SERIES GF-200/GF-300/GF-400/GF-600/GF-800/GF-1000 GF-1200/GF-2000/GF-3000/GF-4000/GF-6100 GF-6000/GF-8000

GX/GF Series. SHS Sensor Series Precision Balances. Unrivalled in capacity and resolution: 210g / 0.001g ~ 8100g / 0.1g TYPE APPROVED PRODUCT (GX)

Instruction Manual for. Torbal AGZN Series Balances

This document hosted by: High-Precision Tuning Fork Electronic Balance. SJ-E Series. Operation Manual IMPORTANT

Compact Balances. EK-610j EK-6100j. in an Authorized A&D Dealer

High-Precision Tuning Fork Electronic Balance. SJ-CE Series. Operation Manual IMPORTANT. To ensure safe and proper use of the balance, please read

Operating instruction Platform scale

Nimbus NBL Series (P.N , Revision 3.00, Effective Aug 2017)

American Weigh Scales, Inc. AMW-BENCH. D i g i t a l T a b l e t o p S c a l e. User Manual

PX Series Balances. Quick Start Guide. Please download the user manual from

Instruction Manual for. Torbal AGCN Series Balances

Explorer. Analytical and Precision Balances. Features Include:

Scout Resource Guide Scout Portable Balances

Operating Instructions Betriebsanleitung Mode d emploi Istruzioni per l uso Manual de instrucciones

Application Guide for the Secura, Quintix and Practum Series of Models

Analytical and Toploading Balances

Eclipse EBL Series (P.N , Revision 1.00, Effective Aug 2015) Operating Manual For internal ( i ) and external ( e ) calibration models

FX-iWP SERIES. Dust and Waterproof Precision Balance INSTRUCTION MANUAL. FX-120i WP / FX-200i WP / FX-300i WP FX-1200i WP / FX-2000i WP / FX-3000i WP

sarbrius Sartorius Master Series

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

Discovery. Ohaus Discovery. Semi-Micro and Analytical Balances. The Professional s Choice For Analytical Applications!

Adventurer TM Pro. The OHAUS Adventurer TM Pro The Most Complete Balance in Its Class! Analytical and Precision Balances

Adventurer TM Pro Analytical and Precision Balances

Sartorius Pipette Calibration Balance

EW EG-(N) Laboratory Balance. Standard. Option (addit. price) KERN Your DKD Calibration Partner. Your specialist dealer

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Sartorius Laboratory. L 610, L2200S, L2200P Electronic Precision Balances Installation and Operating Instructions

1 Weighing pan 2 Weight display 3 ON/OFF key 4 CAL key 5 Tare control 6 Menu access switch (for the balance operating program) 7 Leveling foot (L 2200 S only) 8 Power receptacle 9 level indicator (L 2200 only) 2

Sartorius Laboratory L 610, L 2200 S, L 2200 P With this Sartorius Balance, you have acquired a sophisticated, high-quality electronic precision weighing Instrument that will help ease your daily work load. Please read these Installation and operating instructions carefully before operating your new balance. Pursuant to the German Directive for the Implementation of Regulations for Prevention of Accidents "Elektrische Anlagen und Betriebsmittel (VBG 4)" [Electrical Installations and Equipment] of April, 1986, it is hereby certified that the equipment delivered, "Electronic Precision Balance, model L 610, L 2200 S or L 2200 P," is manufactured and tested in compliance with the following DIN/VDE regulations DIN IEC348/VDE0411: Safety requirements for electronic measuring apparatus DIN IEC 380/VDE 0806: Safety of electrically energized Office machines DIN IEC 601 A/DE 0750: Safety of medical electrical equipment and with Article 10 of the Low Voltage Directive 73/23/EEC issued on February 19, 1973, by the European Community. When you use electrical equipment in installations and under ambient conditions requiring higher safety Standards, you must comply with the provisions as specified in the applicable regulations for installation in your country. 3

Contents Equipment Supplied 5 Installation Instructions 6 Startup 7 Operation 8 Calibration 10 Balance Operating Program 11 Troubleshooting Guide 14 Accessories 15 Specifications 17 4

Equipment Supplied Do not miss out on the benefits of our warranty. Please complete the warranty registration card, indicating the date of installation, and return the card to your Sartorius dealer. The equipment supplied includes the components shown on the left and a dust cover. Save all parts of the packaging and the box for shipping your balance to prevent any damage during transportation. Installation Instructions Ambient Conditions Please choose a suitable place to set up your balance. lt should not be exposed to the following: heat radiation aggressive/corrosive substances vibrations draughts Do not expose the balance to extreme moisture over long periods. Moisture in the air can condense on the surfaces of a cold balance whenever it is brought to a substantially warmer place. lf you Transfer the balance to a warmer area, make sure to condition it for about 2 hours at room temperature, leaving it unplugged. Afterwards, if you leave the balance connected to mains power supply, the continuous positive difference in temperature between the inside of the balance and the outside will practically rule out the effects of moisture condensation. The components used in the balance are rated to at least Class KSF according to DIN 40040. 5

Startup Attach the dust cover by pressing down on the adhesive disks, and mount the weighing pan (1) on the balance. Your balance is powered by an AC adapter. Please make sure that the voltage rating printed on this unit is identical to your local line voltage rating. Plug the cord of the AC adapter into the power receptacle of the balance. Secure the connection by tightening the knurled collar. Now plug the AC adapter into a wall outlet. At the point of use, level the balance using the leveling feet (7) so that the air bubble is entered within the circle of the level indicator (9) (only for the L 2200 S). 6

Operation The weight display provides the following special Status messages for your information: BUSY The processor is still busy processing a function and will not accept any other commands to perform functions at this time. STANDBY The display has been turned off with the ON/OFF key (3), and the balance is now in the STANDBY mode and ready to operate without warm u p. POWER OFF The balance was disconnected from line power (reconnection to line power after the balance was unplugged, power failure). CAL The calibration function has been activated. In addition to grams, this balance gives you a variety of other menu-definable international weight unit options. Select the weight unit you need from the table of the menu options for the balance operating program, and set the appropriate code as described in the section "Balance Operating Program." 7

Press the ON/OFF key (3) to turn the display on or off. You can also turn it on with the tare control (5). After the balance has been plugged into the AC adapter, the weight display will go out whenever you turn oft the power with the ON/OFF key. All other electronic circuits will remain energized (indicated by STANDBY). This means the balance is immediately ready to operate without requiring warmup the next time you switch it on. After the power is turned on, a test of all essential electronic functions is run automatically. This self-test ends with the readout 0.00 g (it the program code setting 511 is used). Now place your sample or object on the pan (1) to determine the weight. Read oft the weight in the display (2) as soon as the weight unit (in this case "g") appears as the stability symbol. lf you wish to use a Container to weigh, or if the weight display does not indicate 0.00 g (or the equivalent with the weight unit of your choice), press the tare control to zero the display. 8

Calibration This is only possible with an accurate calibration weight (L 610-500 g; L 2200 S, L 2200 P - 2,000 g). See the "Accessories." Clear the pan and press the CAL key (4) for at least three seconds until the calibration weight readout appears in the display. Center the calibration weights on the pan. Now the weight unit symbol is displayed. An acoustic signal indicates the end of the calibration procedure. 9

Balance Operating Program The balance operating program lets you adapt your balance to various ambient conditions and to different weighing requirements, and select the weight unit(s) commonly used in your country. At the factory, we have set the codes for a Standard program, which is protected by a locking function to prevent accidental changes. The "menu code" contains the information of the operating program, lt consists of three digits, known as the page (1st digit), the line (2nd digit) and the word (3rd digit) in "computerese." How to access the menu of the balance operating program: With the balance turned off (STANDBY state), hold down the tare control (5) and briefly press the ON/OFF key (3). Upon completion of the automatic self-test, release the tare control as soon as "CH5" is displayed. The Status of the balance operating program will appear in the weight display: "L" Stands for the list mode. In this mode, you can check the menu code settings, but you cannot program new menu codes. lf you wish to change a program menu code, you must first unlock the menu access switch to access the program menu. To do so, remove the protective cap located on the front right of your balance and slide the menu access switch (6) in the direction of the arrow. The display will indicate "C," which Stands for the change mode, meaning you can now change the menu code settings. 10

After you have accessed the menu of the operating program, the display will show a continuous sequence of numbers from 0-5 for the "page" or first digit of the code, in addition to the Status code letter "L" or "C." When the first digit of the code you wish to check or change appears, press the tare control (5). The "page" code number (1st digit) now stops in the display, and a series of numbers for the 2nd digit or "line" will begin to cycle. Press the tare control again to stop the code number of your choice in the display. Next, the numbers for the "word" (last digit) will cycle in the display. Repeat the procedure to enter the last digit of the code. The "o" symbol that appears indicates the actual setting. To change any menu code settings ("C" mode), press the tare control as soon as the appropriate numeric code is displayed. Brief display of BUSY and the "o" symbol confirms your selection, followed by a return to "zero" for the 2nd digit or "line." How to return to the weighing mode: press the tare control each time a 0 appears in the numerical sequence (word, line, page). lf you have changed a menu code, your code entry will be stored as soon as the display returns to the weighing mode. Lock the balance operating program using the menu access switch ("L" readout) and replace the protective cap. Auto Zero This balance has an automatic zero tracking function known as "Auto Zero" (can be turned off by menu code). Any change off zero 0.5 digit per second will be set to zero automatically within a range of ±0.5 of a digit. 11

C 1 3 1 Page Line Word Menu of the Balance Operating Program (Active Parameters) Code Ambient Conditions Code Program Lock C 1 1 1 Very stable C 4 1 1 OFF C 1 1 2 Stable C 4 1 2 ON C 1 1 3 Unstable C 1 1 4 Very unstable Code Acoustic Signal C 4 3 1 ON Code Stability Range C 4 3 2 OFF C 1 2 1 0,25 digit C 1 2 2 0,5 digit Code Weight Units 1 ) C 1 2 3 1 digit C 5 1 1 Grams g C 1 2 4 2 digits C 5 1 2 Kilograms kg C 1 2 5 4 digits C 5 1 3 Carats ct C 1 2 6 8 digits C 5 1 4 Pounds lb C 1 2 7 16 digits c 5 1 5 Ounces oz C 1 2 8 32 digits c 5 1 6 Troy ounces ozt C 1 2 9 64 digits c 5 1 7 Parts/pound o c 5 2 1 Hong Kong taels tl Code Display Format c 5 2 2 Singapore taels tl C 1 3 1 Last decimal ON c 5 2 3 Taiwan taels tl C 1 3 2 Last decimal OFF c 5 2 4 Grains gr C 1 3 3 Last decimal at stability c 5 2 5 Pennyweights dwt C 1 3 4 All decimals at stability c 5 2 6 Mommes o c 5 2 7 Milligrams o Code Tare parameter C 5 2 8 Austrian carats o C 1 4 1 Without stabilty C 1 4 2 At stability C 5 2 0 Call Program Line Code Auto Zero C 5 0 Call Program page C 1 5 1 ON C 1 5 2 OFF C 0 End of programming Code Calibration C 1 6 1 Accessible C 1 6 2 Accessible blocked Additional Parameters for the data Output format at the interface port and for calculation programs are available on request.-please refer to the Accessories." 1) You can choose any weight unit as long as it can be displayed in the particular weighing range you selected (for example do not set the code for "kg" when you are using a 0.1 mg balance). 12

Troubleshooting Guide Problem... Causes... Remedy No segments appear in the weight display (2) - No line voltage available - The connecting cable of the power supply is not plugged into the balance - Check power supply - Plug in the cable Weight display shows L or CH 2 Weight display shows H The weight readout changes constantly or the special message BUSY does not go out in the weight display Weight shows CE The weight readout is obviously wrong - The weighing pan (1) and/or the pan adapter are not in place - Load exceeds capacity of the balance - Unstable ambient conditions - Too much vibration or the balance is exposed to a draft - Sample does not have a stable weight - The Cal key (4) was not pressed when the display read zero - The balance is loaded - The balance has not been calibrated - The balance has not been tared before weighing - Position the pan and the pan adapter - Unload the balance - Set up balance in another area - Access the menu to adjust the proper code for the particular type of weighing environment - Press the tare control (5) - Unload the balance - Calibrate the balance - Tare before weighing 13

Accessories (Options) Data printer, with date/time and statistics functions YDP02-OD Print speed, approx. lines/sec. 1.5 Printer housing (W x D x H) in mm 150 x 138 x 43 Calibration weights for: L 420 D L 420 P (4 x 100 g) 7072 04 L 610 D (1 x 500 g) 7072 16 Interface YDO 01 L "PLUS" Performance Package, integratable (incl. interface) Over/under check weighing/ sorting & classification Mass unit conversion Weight of residue in %/change in % Statistics - Net total/ formulation & compounding Filling toward "0" - Parts counting Animal weighing Calculations by a factor Calculation of the weight per unit area/division Accumulator memory - I.D. no. memory Communication with Computers Thermo Control infrared dryer, programmable Remote display (can be plugged into the interface port of the balance) LCD, reflective for overhead projectors, transmissive Extra-large special draft shield Carrying case YDO 01 L+ YTC 01 L 7371 01 A 7371 02 A YDS 01 L YDB 02 L Antiheft locking device 6087 Dust cover 69 60L220 14

Specifications Model L 610 L 2200 S L 2200 P Weighing range g 610 2220 400/800/2220 Readability g 0,01 0,01 0,01/0,02/0,05 Tare range (by subtraction) g -610-2220 -2220 Standard deviation g ± 0,005 ± 0,005 ± 0,01/0,01/0,025 Max. linearity deviation g ± 0,01 ± 0,015 ± 0,02/0,02/0,05 Stabilization time (typical) s 2 Display update rate s 0,1... 0,8 (selectable) Adaption to ambient conditions and application requirements by selection of one of four digital filter levels Stability range d 0,25... 64 (selectable) Ambient temperature range K +273... +313 (0 o C... +40 o C) Sensitivity drift within 283 303 K /K ± 5 10-6 ± 2 10-6 ± 1 10-5 Deviation of readout when balance is tilted 1 : 1000 g ± 0,01 ± 0,01 ± 0,01/0,02/0,05 Pan dimensions mm 211 x 169 Balance housing (W x D x H) mm 220 x 235 x 75 Net weight, ca. kg 4,5 Power requirements (voltage; frequency: 50 60 Hz Power consumption VA 7 (typical) Interface (optional) 100/120 V or 220/240 V, depending on the power supply unit (adapter) used RS 232 C/V24 28, RS 423/V10; 7-bit; parity: even, mark, odd, space; transmission rates: 150... 9600 Baud 15

Sartorius AG B 37070 Göttingen P Weender Landstraße 94 108, 37075 Göttingen T (0551) 308-0, F (0551) 308-3289 Internet: http://www.sartorius.com Copyright by Sartorius AG, Göttingen, Deutschland. All rights reserved. No part of this publication may be printed or translated in any form or by any means without the prior written permission of Sartorius AG. Sartorius AG reserves the right to make change to the technology, features, specification and design of the equipment without notice.