ERNT-AQTD61 ERNT-AQTD61 ERNT-AQTD61. User s Manual. Mitsubishi General-Purpose Programmable Controller Renewal Tool Conversion Adapter.

Similar documents
ERNT-AQTX10 ERNT-AQT68AD-GH. User s Manual. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter.

Additional Explanation for A851GOT Graphic Operation Terminal

DC I/O Conversion Module FA-TB32XY

FX1N-2EYT-BD Output Expansion Board

FX1N-4EX-BD Input Expansion Board

DC I/O Conversion Module

S82S (3/7.5-W Models)

User Guide. Control Box. RoscoLED TM.

TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- RELAY OUTPUT FR-A5AR

Wall. No opening (Example: LA-030-W)

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

B63/ NS MS. EtherNet/IP LINK

VECTOR INVERTER -INSTRUCTION MANUAL- HIGH RESOLUTION ANALOG INPUT / EXTRA CONTACT INPUT / THERMISTOR INTERFACE FR-V5AX

SAFETY PRECAUTIONS. (Read these precautions before using this product.)

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE

FR-A8AR INSTRUCTION MANUAL

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Solid State Relays with Failure Detection Function

VESSEL + Todd Bracher. Installation Guide Sconce

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

MELSEC-L Analog Input/Output Module User's Manual -L60AD2DA2

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

INVERTER INSTRUCTION MANUAL. Relay output function. Plug-in option FR-A7AR PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Mitsubishi Electric General-purpose Programmable Controllers MELSEC-A/QnA (Large), AnS/QnAS (Small) Transition Examples. Apr.

Analog Input Installation Manual

Table of Contents Product Overview Before using the product Installation Procedure... 5

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3

3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Optional add-on cassette Attachment Instruction manual

YAMAHA Robot Controller. MRCH/QRCH/QRCX Series UNIT OWNER'S MANUAL

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

FX2N-4AD-PT SPECIAL FUNCTION BLOCK

MDM 011-Z1 Regen Resistor

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Kinetix 6000 Axis Module and Shunt Module

MELSEC-Q High Speed Analog-Digital Converter Module User's Manual -Q64ADH

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

V E2B Snap-in I/O Module

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Touch-controller_IM_03943A_1_Co_EN.indd 오후 3:06:00

KBMG MULTI-SPEED BOARD

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

PRODUCT SPECIFICATION. PC Board Relays. Series.

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

User s Manual YAMAHA NETWORK BOARD

OWNER S MANUAL. Additional Camera Unit AC-CAM-210 Compatible with AC210 Baby Video Monitor TABLE OF CONTENTS

Install Motor Controller User Manual

Analog Monitor Installation Manual

Demo Kit Quick Start Guide

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Conductive Level Controller

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Quick Start Guide CJB1950ALAAB

ESV3000 ETDRS Illuminated Cabinet INSTRUCTION MANUAL

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

MELSEC-L Flexible High-Speed I/O Control Module User's Manual

NOTICES NOTICE OF INTENDED USE

Installation Instruction. HART Add-On Module

MELSEC iq-r Channel Isolated Thermocouple Input Module/Channel Isolated RTD Input Module User's Manual (Startup) -R60TD8-G -R60RD8-G

Output Terminal Module

Installation manual plugs and connectors with screw connection (16/32 A)

MELSEC iq-r EtherNet/IP Network Interface Module User's Manual (Application) -RJ71EIP91

1. Safety Precautions (Read these precautions before use.)

MELSEC iq-r Digital-Analog Converter Module User's Manual (Startup) -R60DA4 -R60DAV8 -R60DAI8

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

MELSEC iq-r Channel Isolated Analog-Digital Converter Module User's Manual (Startup) -R60AD8-G -R60AD16-G

VR 71. Installation instructions. Installation instructions. For the competent person GB, IE. Publisher/manufacturer Vaillant GmbH

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Cat. No. I153E-EN-01. SCARA Robots ZX-T YRC Series. DeviceNet USER S MANUAL

PC-HELPER. Expansion Adapter for Express Card Slot EAD-CE-EC. User s Manual CONTEC CO.,LTD.

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

HIGH PERFORMANCE TRANSISTOR INVERTER TRUE TORQUE CONTROL SERIES

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

Chore-Tronics Mobile Server

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

SERVICE MANUAL MODEL SSW-520-F

CMSA-100 Manual. Cinema Media Server Automation

MELSEC iq-r Analog-Digital Converter Module User's Manual (Startup) -R60AD4 -R60ADV8 -R60ADI8

V E1B Snap-in I/O Module

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

AnyWire System Product Guide. AnyWire Picking Terminal series/ Transparent Type A027PB-T02G-P/ light-emitting unit A027XB-T02G-C/ light-receiving unit

Display Panel BAT 100 LSN. en Operation Guide

PMDX-170 Slotted Optical Sensor

Resolver to Digital Expansion Board

TSD-SEQ6 Sequencer Controller

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Transcription:

Mitsubishi General-Purpose Programmable ontroller Renewal Tool onversion Adapter Model ERNT-AQTD61 User s Manual ERNT-AQTD61 Model ERNT-AQTD61 50M-D180036-(1007)MEE EAD OFFIE:NIONJISO-DAIII BLDG.1-13-5,KUDANKITA IYODA-KU,TOKYO 10-0073,JAPAN NAGOYA ENGINEERING OFFIE:139 SIMOYASIKIO-SIMOYASIKI,KASUGAI,AII 486-0906,JAPAN

SAFETY PREAUTIONS (Always read these precautions prior to use.) Before using this product, please read this manual carefully and pay full attention to safety to ensure that the product is used correctly. The precautions presented in this manual are concerned with this product only. For Programmable ontroller system safety precautions, refer to the user s manual of the MELSE-Q series PU module to be used. In this manual, the safety precautions are ranked as DANGER and AUTION. DANGER AUTION Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury. Indicates that incorrect handling may cause hazardous conditions, resulting in medium or minor injury and/or property damage. Note that failure to observe the AUTION level instructions may lead to a serious consequence according to the circumstances. Always follow the precautions of both levels because they are important to personal safety. Please keep this manual in an easy-to-access location for future reference, and be sure to provide the manual to the end user. [Precautions: Prior to Use] AUTION When replacing the MELSE-A series with the MELSE-Q series, be sure to refer to the various MELSE-Q series module manuals to check the differences in performance, functionality, PU input/output signals, buffer memory addresses, and the like. In addition, we recommend that you also refer to the document L(NA)08045-D, Guidelines: Replacing MELSE-A/QnA (Large-Size) Series with Q Series (Intelligent Function Module). [Installation Precautions] AUTION Use the conversion adapter and conversion adapter anchor base in an environment of the general specifications defined in the MELSE-Q series PU module user s manual. Failure to do so could lead to electric shock, fire, malfunction or product failure or deterioration. Do not come in direct contact with the conductive area of the conversion adapter. Doing so could lead to system malfunction or failure. Fully secure the conversion adapter and conversion adapter anchor base using the installation screws, and tighten the installation screws securely within the specified torque range. Failure to do so could cause the conversion adapter and anchor base to fall, resulting in conversion adapter and conversion adapter anchor base damage. Be sure to confirm that the MELSE-Q series and conversion adapter combination is correct. Use of a different combination may result in module damage

[Wiring Precautions] DANGER Be sure to shut off all phases of the external power supply before performing installation or wiring work. Failure to do so could result in electric shock or product damage. If you want to energize and run the unit after completing the installation and wiring work, be sure to close the terminal block cover attached to the MELSE-A series terminal block. Failure to do so could result in electric shock. AUTION Properly wire the conversion adapter after verifying the specifications and terminal layout of the module to be used. onnecting a power supply with a different rating or improper wiring could lead to fire or product failure. Securely tighten the conversion adapter installation screws, conversion adapter anchor base installation screws and MELSE-A series terminal block installation screws within the specified torque range. A loose screw may result in a short circuit, fire or malfunction. An excessively tightened screw may result in screw or conversion adapter damage, causing the conversion adapter to fall, a short circuit or product malfunction. Do not allow foreign matter such as cuttings or wiring shavings to enter the conversion adapter or module. Doing so could lead to fire, failure or malfunction. [Startup and Maintenance Precautions] DANGER Do not touch the terminals during energization. Doing so could result in electric shock or malfunction. Be sure to shut off all phases of the external power supply before cleaning and retightening terminal screws. Failure to do so results in the risk of electric shock. Excessively tightened screws could result in conversion adapter and module damage, causing the conversion adapter to fall, a short circuit, or product malfunction. AUTION Do not disassemble or modify the conversion adapter. Doing so could lead to failure, malfunction, injury or fire. The conversion adapter case is made of resin. Do not drop or apply excessive impact to the case. Doing so could lead to conversion adapter damage. [Disposal Precautions] AUTION When disposing of the product, treat it as industrial waste.

EM AND LOW VOLTAGE DIRETIVES ompliance to the EM Directive, which is one of the EU Directives, has been a legal obligation for the products sold in European countries since 1996 as well as the Low Voltage Directive since 1997. Manufacturers who recognize their products are compliant to the EM and Low Voltage Directives are required to declare that print a "E mark" on their products. Authorized representative in Europe Authorized representative in Europe is shown below. Name: Mitsubishi Electric Europe B.V. (EM.. Division) Address: Gothaer strasse 8, 40880 Ratingen, Germany 1. Overview This manual describes the Mitsubishi general-purpose Programmable ontroller renewal tool conversion adapter (ERNT-AQTD61) and the conversion adapter anchor base (sold separately; ERNT-AQF1/-AQF8/-AQF5/-AQF3) that secures the bottom of the conversion adapter. The conversion adapter is a product that converts the differences in MELSE-A series and MELSE-Q series pin assignments. When replacing the MELSE-A series with the MELSE-Q series, be sure to refer to the various MELSE-Q series module manuals to check the differences in performance, functionality, PU input/output signals, buffer memory addresses, and the like. In addition, we recommend that you also refer to the document L(NA)08045-D, Guidelines: Replacing MELSE-A/QnA (Large-Size) Series with Q Series (Intelligent Function Module). Once you have opened the packaging, verify that it contains the following products. Product Quantity onversion adapter 1 Mounting bracket 1 Mounting bracket fixing screw (M.6 x 4)

. onversion Adapter Product Specifications onversion A Series Module No. of input Q Series Module onversion Adapter Adapter Model Model Points Model Weight (g) ERNT-AQTD61 AD61 QD6 105 QD6-01 AD61-S1 QD6-0 A Series Terminal Block TB TB4 TB6 TB8 TB10 TB1 TB14 TB16 TB18 TB0 TB TB4 TB6 TB8 TB30 TB3 TB34 TB36 TB38 TB1 TB3 TB5 TB7 TB9 TB11 TB13 TB15 TB17 TB19 TB1 TB3 TB5 TB7 TB9 TB31 TB33 TB35 TB37 For the power supply terminal, use the 1 side. Terminal No. TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB1 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB0 TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB30 TB31 TB3 TB33 TB34 TB35 TB36 TB37 TB38 1 Signal Name OPEN(1 PRST 1V) PhaseA 4V PhaseA 1V PhaseA 5V PhaseA OM PhaseB 4V PhaseB 1V PhaseB 5V PhaseB OM DIS 4V DIS OM PRST OM PhaseA 4V PhaseA 1V PhaseA 5V PhaseA OM PhaseB 4V PhaseB 1V PhaseB 5V PhaseB OM DIS 4V DIS OM PRST OM OPEN(1 DIS 1V) OPEN( PRST 1V) OPEN( DIS 1V) Terminal No. A0 B0 A19 B19 A18 B18 A17 B17 A16 B16 A15 B15 A14 B14 A13 B13 A1 B1 A11 B11 A10 B10 A9 B9 A8 B8 A7 B7 A6 B6 A5 B5 A4 B4 A3 B3 A B A1 B1 1 Signal Name PhaseA 4V PhaseA 1V PhaseA 5V AB OM PhaseB 4V PhaseB 1V PhaseB 5V PRST 1V TRL OM FUN 4V FUN 1V FUN 5V PhaseA 4V PhaseA 1V PhaseA 5V AB OM PhaseB 4V PhaseB 1V PhaseB 5V PRST 1V TRL OM FUN 4V FUN 1V FUN 5V 1 EQU1 1 EQU EQU1 EQU OPEN OPEN OPEN OPEN 0V 1/4V 0V 1/4V Q Series onnector When the preset input and disable input are used at 1V, disconnect the wiring connected to TB9, 1, 7, and 30, and connect the wiring to open terminals (TB18, 36, 37, and 38). onversion Adapter

Module Specification omparison hart Item No. of channels ounting speed switch setting ount input signal Phase Signal level (ФA, ФB) Model MELSE-A Series AD61 QD6-01 channels channels channels - 1-phase input -phase input 5VD/1VD/4VD : to 5mA 00K (100K to 00KPPS) QD6 100K (10K to 100KPPS) 1-phase input, -phase input 5VD/1VD/4VD: to 5mA MELSE-Q Series 10K (10KPPS or less) - 1-phase input -phase input 5VD/1VD/4VD : to 5mA Performance specifications per channel ounter Size comparison External input ounting speed (maximum) 1-phase input: 50KPPS -phase input: 50KPPS ounting range 4-bit binary (0 to 1677715) Form omparison range omparison result Preset ount disable Up/Down preset counter + Ring counter function Binary format (binary) 4 bits Setting value < ount value Setting value = ount value Setting value > ount value 1/4VD: 3/6mA 5VD: 5mA 1/4VD: 3/6mA 5VD: 5mA 1-phase input: 00KPPS 1-phase input: 100KPPS 1-phase input: 10KPPS -phase input: 00KPPS -phase input: 100KPPS -phase input: 10KPPS 3-bit signed binary (-147483648 to 147483647) Up/Down preset counter + Ring counter function 3-bit signed binary Setting value < ount value Setting value = ount value Setting value > ount value 5/1/4VD: to 5mA - 1-phase input: 50KPPS -phase input: 50KPPS 3-bit binary (-147483648 to 147483647) Up/Down preset counter + Ring counter function 3-bit signed binary Setting value < ount value Setting value = ount value Setting value > ount value 5/1/4VD: to 5mA - Function start - 5/1/4VD: to 5mA 5/1/4VD: to 5mA External output No. of occupied points urrent consumption Match output Transistor output Transistor output Transistor output 1/4VD 0.5A/point 1/4VD 0.5A/point 1/4VD 0.5A A/common A/common 3 points 16 points 16 points 0.30A 0.30A 0.30A Item No. of channels Model MELSE-A Series MELSE-Q Series AD61-S1 QD6-0 channels channels ounting speed switch setting - - ount input signal Phase Signal level (ФA, ФB) 1-phase input -phase input 5VD/1VD/4VD : to 5mA 1-phase input -phase input 5VD/1VD/4VD : to 5mA Performance specifications per channel ounter Size comparison External input ounting speed (maximum) 1-phase input: 10KPPS -phase input: 7KPPS ounting range 4-bit binary (0 to 1677715) Form omparison range omparison result Preset ount disable Up/Down preset counter + Ring counter function Binary format (binary) 4 bits Setting value < ount value Setting value = ount value Setting value > ount value 1/4VD: 3/6mA 5VD: 5mA 1/4VD: 3/6mA 5VD: 5mA 1-phase input: 10KPPS -phase input: 7KPPS 3-bit binary (-147483648 to 147483647) Up/Down preset counter + Ring counter function 3-bit signed binary Setting value < ount value Setting value = ount value Setting value > ount value 5/1/4VD: to 5mA - Function start - 5/1/4VD: to 5mA External output Match output No. of occupied points urrent consumption Transistor output Transistor output 1/4VD 0.5A/point 1/4VD 0.5A A/common 3 points 16 points 0.30A 0.30A

Note: 1. (terminal numbers TB1 and TB30) of the MELSE-A series side is connected to of QD6. When preset input is used at 1V, use is enabled by connecting the (terminal numbers TB1 and TB30) wiring to terminal numbers TB18 and TB37. (Refer to the figure on the right). Because the external input specifications differ, the specifications of the external device need to be checked. Note 1V input Note 1 1V input Note 1V input Note 1 1V input Terminal No. TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB1 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB0 TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB30 TB31 TB3 TB33 TB34 TB35 TB36 TB37 TB38 1 Signal Name Open(1 PRST 1V) Phase A 4V Phase A 1V Phase A 5V Phase A OM Phase B 4V Phase B 1V Phase B 5V Phase B OM DIS 4V DIS OM PRST OM Phase A 4V Phase A1V Phase A 5V Phase A OM Phase B 4V Phase B 1V Phase B 5V Phase B OM DIS 4V DIS OM PRST OM Open(1 DIS 1V) Open( PRST 1V) Open( DIS 1V) hange Note 1 1V input Note 1V input Note 1 1V input Note 1V input Terminal No. TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB1 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB0 TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB30 TB31 TB3 TB33 TB34 TB35 TB36 TB37 TB38 1 Open(1 PRST 1V) Signal Name Phase A 4V Phase A 1V Phase A 5V Phase A OM Phase B 4V Phase B 1V Phase B 5V Phase B OM DIS 4V DIS OM PRST OM Phase A 4V Phase A 1V Phase A 5V Phase A OM Phase B 4V Phase B 1V Phase B 5V Phase B OM DIS 4V DIS OM PRST OM Open(1 DIS 1V) Open( PRST 1V) Open( DIS 1V)

. DIS 4V (terminal numbers TB9 and TB7) of the MELSE-A series side is connected to FUN 4V of QD6. When disable input is used at 1V, use is enabled by connecting the DIS 4V (terminal numbers TB9 and TB7) wiring to terminal numbers TB36 and TB38. (Refer to the figure on the right.) Because the external input specifications differ, the specifications of the external device need to be checked. 3. Program changes (changes to the number of occupied input/output points, input/output signals, and buffer memory addresses) are required. 4. For the AD61 match output external power supply, use the 1 side (terminal numbers TB17 and 16) only. When the -side external power supply (terminal numbers TB35 and 34) is used, wiring changes are required. (Refer to the figure on the right.) Additionally, when the 1-side external power supply (terminal numbers TB17 and 16) and -side external power supply (terminal numbers TB35 and 34) are used based on separate power supplies, the power supplies need to be changed to the same power supplies. External power supply External power supply Terminal No. TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB1 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB0 TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB30 TB31 TB3 TB33 TB34 TB35 TB36 TB37 TB38 1 Signal Name Open(1 PRST 1V) Phase A 4V Phase A 1V Phase A 5V Phase A OM Phase B 4V Phase B 1V Phase B 5V Phase B OM DIS 4V DIS OM PRST OM Phase A 4V Phase A 1V Phase A 5V Phase A OM Phase B 4V Phase B 1V Phase B 5V Phase B OM DIS 4V DIS OM PRST OM Open(1 DIS 1V) Open( PRST 1V) Open( DIS 1V) hange External power supply External power supply Terminal No. TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB1 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB0 TB1 TB TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB30 TB31 TB3 TB33 TB34 TB35 TB36 TB37 TB38 Signal Name Phase A 4V Phase A 1V Phase A 5V Phase A OM Phase B 4V Phase B 1V Phase B 5V Phase B OM DIS 4V 1 DIS OM PRST OM Open(1 PRST 1V) Phase A 4V Phase A 1V Phase A 5V Phase A OM Phase B 4V Phase B 1V Phase B 5V Phase B OM DIS 4V DIS OM PRST OM Open(1 DIS 1V) Open( PRST 1V) Open( DIS 1V) 5. For detailed and general specifications not stated in the Specification omparison hart, refer to the user s manual of the module used. In addition, we recommend that you also refer to the document L(NA)08045-D, Guidelines: Replacing MELSE-A/QnA (Large-Size) Series with Q Series (Intelligent Function Module). For those sections in which the MELSE-A series specifications and MELSE-Q series specification differ, specification restrictions may apply upon replacement. heck the specifications of the connected devices.

3. Products Required by the onversion Adapter (1) onversion Adapter Anchor Base (Sold Separately) The conversion adapter anchor base secures the bottom of the conversion adapter and is required for conversion adapter use. One anchor base is required per base. onversion Adapter Anchor Base Model Type Specifications Weight (g) ERNT-AQF1 1-slot conversion adapter anchor base 590 ERNT-AQF8 8-slot conversion adapter anchor base 410 ERNT-AQF5 5-slot conversion adapter anchor base 75 ERNT-AQF3 3-slot conversion adapter anchor base 185 () Base Adapter (Sold Separately) The base adapter enables MELSE-Q series installation using the installation holes of the MELSE-A series base unit. (Additional hole machining not required) Base Adapter Model ERNT-AQB38 MELSE-A Series ompliant Module A38B A38B Specifications MELSE-Q Series ompliant Module Q31B Q38B ERNT-AQB68 A68B Q61B Q68B Installable onversion Adapter Anchor Base ERNT-AQF1 ERNT-AQF8 Weight (g) ERNT-AQB58 A58B Q68B ERNT-AQF8 870 ERNT-AQB35 A35B Q38B Q35B ERNT-AQB65 A65B Q68B Q65B Q55B ERNT-AQB55 A55B Q65B Q55B ERNT-AQF8 ERNT-AQF5 970 930 795 790 ERNT-AQF5 655 ERNT-AQB3 A3B Q33B ERNT-AQF3 675 ERNT-AQB6 A6B Q63B Q5B ERNT-AQB5 A5B Q5B 650 505

4. Mounting and Installation 4.1 andling Precautions (1) Do not touch the terminals during energization. Doing so could result in electric shock or malfunction. () Do not disassemble or modify the conversion adapter. Doing so could result in failure, malfunction, injury or fire. (3) Do not come in direct contact with the conductive area of the conversion adapter. Doing so could result in system malfunction or failure. (4) Fully secure the conversion adapter and conversion adapter anchor base using the installation screws, and securely tighten the screws within the specified torque range. Failure to do so could cause the conversion adapter and anchor base to fall, resulting in conversion adapter and conversion adapter anchor base damage. 4. Use Precautions Item Use Precautions Module width dimension Because the module width decreases (from 37.5mm to 7.4mm), the wiring area decreases. Verification prior to installation is required. MELSE-A series MELSE-Q series module module I/O Depth 37.5 7.4 The depth increases. Verification prior to installation is required. Q series module A series module + Renewal tool onversion adapter Base adapter 140 165.3 UP 5.3mm(13.5mm) onversion adapter anchor base The value in parentheses is the dimension when the base adapter is not used. 4.3 Installation Environment For details of the installation environment, refer to the user s manual of the MELSE-Q series PU module to be used.

5. Part Names and Installation Method Q series module Mounting bracket (conversion adapter accessory) Mounting bracket fixing screw M.6 x 4 (conversion adapter accessory) 3 onversion adapter installation screw M3 x 18 5 MELSE-A series terminal block installation screw (M4) 6 onversion adapter anchor base 5 onversion adapter MELSE-A series terminal block onversion adapter bottom installation screw M3 x 0 4 onversion adapter anchor base installation screw M4 x 8 (conversion adapter anchor base accessory) 6 5.1 Installation Method [1] Secure the conversion adapter anchor base to the base adapter or control panel using the conversion adapter anchor base installation screws (M4 8) provided as an accessory. (Two end locations) [] Secure the mounting bracket to the Q series module using the mounting bracket fixing screws [M.6 4 (conversion adapter accessory); two upper/lower locations]. [3] Mount the conversion adapter onto the mounting bracket. [4] Secure the conversion adapter using the conversion adapter bottom installation screw (M3 0; 1 location). [5] Secure the conversion adapter using the conversion adapter installation screws (M3 18; locations). [6] Secure the MELSE-A series terminal block to the conversion adapter using the terminal block installation screws (M4; two upper/lower locations). 5. Tightening Torque Tighten the module installation screws to the specified torque below. An inappropriate tightening torque could cause the product to fall or result in a short circuit, product failure or malfunction. Screw Location onversion adapter anchor base installation screw (M4 screw) Mounting bracket fixing screw (M.6 screw) onversion adapter bottom installation screw (M3 screw) onversion adapter installation screw (M3 screw) MELSE-A series terminal block installation screw (M4 screw) Tightening Torque Range 139 to 189N cm 34 to 46 N cm 43 to 57 N cm 10 to 138 N cm

6. onversion Adapter Anchor Base Installation Method To use the conversion adapter, a conversion adapter anchor base (ERNT-AQF1/-AQF8/-AQF5/-AQF3) is required. Q Base Unit onversion Adapter Anchor Base Q31B Q38B Q35B Q33B Q61B Q68B Q65B Q63B Q55B Q5B ERNT-AQF1 ERNT-AQF8 ERNT-AQF5 ERNT-AQF3 : Applicable : Applicable (with some restrictions *1 ) : Not applicable *1: There are certain slots in which the conversion adapter cannot be installed. For example, the conversion adapter cannot be installed in Slots 8 to 11 (4 slots) of the Q base unit when Q31B (Q base unit) is used with ERNT-AQF8 (conversion adapter anchor base). The machining of screw holes (M4 locations) used to install the conversion adapter anchor base, such as described below, is required when a base adapter (sold separately) is not used. (1) With Main Base Unit Q31B, Q38B, Q35B or Q33B 118.5±0. PU ERNT-AQF** Machine screw holes (M4 x locations) in these locations for conversion adapter anchor base installation. onversion Adapter A Anchor Base 94.8±0. A±0. ERNT-AQF1 31. ERNT-AQF8 10 ERNT-AQF5 16.6 ERNT-AQF3 71

() With Extension Base Unit Q61B, Q68B Q65B or Q63B 118.5±0. 87.4±0. ERNT-AQF** A±0. Machine screw holes (M4 x locations) in these locations for conversion adapter anchor base installation. onversion Adapter Anchor Base A ERNT-AQF1 31. ERNT-AQF8 10 ERNT-AQF5 16.6 ERNT-AQF3 71 (3) With Extension Base Unit Q55B 118.5±0. Machine screw holes (M4 x locations) in these locations for conversion adapter anchor base installation. ERNT-AQF5 31.8±0. 16.6±0.

(4) With Extension Base Unit Q5B 118.5±0. Machine screw holes (M4 x locations) in these locations for conversion adapter anchor base installation. ERNT-AQF3 4±0. 71±0. Tips Use of a base adapter (sold separately) eliminates the need for additional screw hole machining on the control panel. (A base adapter is a product that enables MELSE-Q series installation using the MELSE-A series installation holes.)

7. External Dimensions 7.1 onversion Adapter Mounting bracket 31 04 70 17.55 7.4 7. onversion Adapter Anchor Base 0 A B 7.8 98 Model ERNT-AQF1 ERNT-AQF8 ERNT-AQF5 ERNT-AQF3 A B 335.8 4.6 141. 85.6 305.8 194.6 111. 55.6 31. 10 16.6 71

Product Warranty Details Please confirm the following product warranty details prior to product use. Gratis Warranty Terms and Gratis Warranty Range If any fault or defect (hereinafter referred to as Failure ) attributable to Mitsubishi Electric Engineering ompany Limited (hereinafter referred to as MEE ) should occur within the gratis warranty period, MEE shall repair the product free of charge via the distributor from whom you made your purchase. Gratis Warranty Period The gratis warranty period of this product shall be one (1) year from the date of purchase or delivery to the designated place. Note that after manufacture and shipment from MEE, the maximum distribution period shall be six (6) months, and the gratis warranty period after manufacturing shall be limited to eighteen (18) months. In addition, the gratis warranty period for repaired products shall not exceed the gratis warranty period established prior to repair. Gratis Warranty Range The gratis warranty range shall be limited to normal use based on the usage conditions, methods and environment, etc., defined by the terms and precautions, etc., given in the instruction manual, user s manual and caution labels on the product. Warranty Period after Discontinuation of Production (1) MEE shall offer product repair services (fee applied) for seven (7) years after production of the product has been discontinued. Discontinuation of production shall be reported via distributors. () Product supply (including spare parts) is not possible after production has been discontinued. Exclusion of Opportunity Loss and Secondary Loss from Warranty Liability Regardless of the gratis warranty period, MEE shall not be liable for compensation for damages arising from causes not attributable to MEE, opportunity losses or lost profits incurred by the user due to Failures of MEE products, damages or secondary damages arising from special circumstances, whether foreseen or unforeseen by MEE, compensation for accidents, compensation for damages to products other than MEE products, or compensation for other work carried out by the user. hanges in Product Specifications The specifications given in the catalogs, manuals and technical documents are subject to change without notice. This document is a new publication, effective July 010. Specifications are subject to change without notice. The standard price does not include consumption tax. Please note that consumption tax will be added at the time of purchase. This manual was printed on recycled paper. Developed July 010 50M-D180036-