Inductive sensor BI1.5-EG08-Y1-H1341

Similar documents
Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Technical Data. General specifications. Rated operating distance s n 3 mm

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Pneumatic Control/Feedback

standard, short, preferential, top

Pneumatic Control/Feedback

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

PHOENIX CONTACT - 12/2007

Pneumatic Control/Feedback

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

Thread length (overall length) material

Series 3730 Type Electropneumatic Positioner

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Inductive proximity switches with long operating distance, series 500

NAMUR INDUCTIVE SENSOR ATEX/IECEx

Series 3730 Electropneumatic Positioner Type

Sensor boxes SRBG Key features

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

PI-EX-ME-2NAM/COC-24VDC

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

PHOENIX CONTACT - 01/2008

PI-EX-ME-2NAM/COC-120VAC

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Flow monitoring For the connection of intrinsically safe flow sensors IO-Link device with relay outputs FMX-IM-3UR38X

Fieldbus I/O module PROFIBUS-DP 16 configurable digital channels, as PNP inputs or 2 A outputs TBDP-L2-16DXP

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

5 Fieldbus Technology

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

PHOENIX CONTACT - 05/2007

Datasheet - CSS 11-30S-D-M-ST

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Your Global Automation Partner. Inductive Sensors uprox with IO-Link Interface. Operating Instructions

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

TBEN-L Multiprotocol Module for Ethernet Compact RFID and I/O Module Programmable via CODESYS V3 with WebVisu License TBEN-L5-4RFID-8DXP-CDS-WV

Safety switches with separate actuator

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

Rotary Measurement Technology Absolute Encoders, Singleturn

APPLICATION GUIDE. Interface Modules IM Series.

Safety switches with separate actuator

Rotary Measurement Technology Absolute Encoders, Multiturn

LS 6600 Technical Datasheet

Safety switches with manual mechanical delay and separate actuator

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Safety coded magnetic sensor SR A series

FLEX Ex Spring Clamp Terminal Base

Datasheet - BNS ZG-ST

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

PROFIBUS-PA Positioner Type 3785

TBEN-L Multiprotocol Module for Ethernet interface for 4 BL ident read-write heads (HF/UHF) TBEN-L5-4RFID-8DXP-CDS

BL67 electronic module 4 analog inputs for current/voltage BL67-4AI-V/I

Electrical connection

Your Global Automation Partner. Teachable Capacitive Sensors. Operating Instructions

PFK series M18 cylindrical inductive sensors

Rotary Measurement Technology Absolute Encoders, Singleturn

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Compact multiprotocol I/O module for Ethernet 16 digital channels, configurable as 2 A PNP inputs or outputs TBEN-L1-16DXP

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

T EN TROVIS Electropneumatic Positioner

KINAX WT720 absolute, programmable angular postion transmitter

Safety switches for hinged doors

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

interface for 4 BL ident read-write heads (HF/UHF) TBEN-L5-4RFID-8DXP-CDS

Operating instructions

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Safety switches with separate actuator

Special-Purpose Proximity Sensor E2C

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Transcription:

ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1 with redundant configuration HFT1 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12 x 1 male connector Type designation Ident-No. 1003502 Wiring Diagram Rated switching distance Sn 1.5 mm Mounting conditions Flush Secured operating distance ð (0,81 x Sn) mm Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy ð 2 % of full scale Temperature drift ð ± 10 % Hysteresis 1 10 % Ambient temperature -25 +70 C Output function Switching frequency Voltage Non-actuated current consumption Actuated current consumption 2-wire, NAMUR 5 khz Nom. 8.2 VDC ï 2.1 ma ð 1.2 ma Functional principle Inductive sensors detect metal objects contactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil. Approval acc. to KEMA 02 ATEX 1090X Design Threaded barrel,m8 1 Dimensions 57 mm Housing material Stainless steel, 1.4427 SO Active area material Plastic, PA12-GF30 Max. tightening torque housing nut 5 Nm Electrical connection Connectors, M12 1 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 C Packaging unit 1 1 / 6 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com

Distance D Distance W Distance T Distance S Distance G 2 x B 3 x Sn 3 x B 1.5 x B 6 x Sn Diameter active area B Ø 8 mm 2 / 6 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com

Accessories IM1-22EX-T 7541232 Isolating switching amplifier, 2-channel; 2 transistor outputs; input NAMUR signal; selectable ON/OFF mode for wirebreak and short-circuit monitoring; switchable between NO / NC mode; removable terminal blocks; width 18 mm; universal voltage supply unit QM-08 6945100 Quick-mount bracket with dead-stop, chrome-plated brass, male thread M12 x 1. Note: The switching distance of proximity switches may be reduced through the use of quick-mount brackets. BST-08B 6947210 Fixing clamp for threaded barrel devices, with dead-stop; material: PA6 MW-08 6945008 Mounting bracket for threaded barrel devices; material: Stainless steel A2 1.4301 (AISI 304) BSS-08 6901322 Mounting bracket for smooth and threaded barrel devices; material: Polypropylene 3 / 6 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com

Accessories MBS80 69479 Mounting bracket for threaded barrel devices; material mounting block: Anodized aluminium IMC-DI-22EX- PNO/24VDC 7560003 2-channel isolating switching amplifier with M12x1 males, for peripheral use, IP67, zones 2/22, input circuits II(1) Ex ia, PNP transistor output NO IMX12-DI01-2S-2T-0/ 24VDC 7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/NC mode; signal doubling; removable screw terminals; 12.5 mm wide; 24 VDC power supply Wiring accessories RKC4.221T-2/TEB 6628420 Connection cable, female M12, straight, 2-pin, cable length: 2 m, sheath material: PVC, black; culus approval; other cable lengths and qualities available, see www.turck.com RKC4.221T-10/TEB 6628422 4 / 6 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com

Wiring accessories WKC4.221T-2/TEB 6628427 WKC4.221T-10/TEB 6628429 5 / 6 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com

Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 1 G and Ex ia IIC T6 Ga and É II 1 D Ex ia IIIC T95 C Da acc. to EN 60079-0, -11 Local admissible ambient temperature -25 +70 C Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Attention! When used in safety systems, all content of the security manual must be observed. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 6 / 6 TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com