SL2400 Compact Monitor

Similar documents
91370 SL2600 Compact Monitor

PHYSICAL INTERFACES 5406R

Control Panel CP600 CP651, CP651-WEB

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

VCL-TP, Teleprotection Equipment

Control Panel CP600 CP635, CP635-B, CP635-WEB

Safety Standards. Model Number:

Voltage Current Front-mounting bracket

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Control Panel CP600-eCo CP604, CP604-B

Safety Standards. Model Number: Unit Weight:

PanelView Plus/VersaView CE Terminals and Display Modules

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Control Panel CP600 CP635-FB, CP635-FW

4600 Series RAID-Enabled

HMISCU6B5. Main. 60 right 40 top 60 bottom

HMISCU6A5. Main. 60 right 40 top 60 bottom

3500/95 System Integrated PC Display Bently Nevada* Asset Condition Monitoring

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

TU531, TU532 Terminal Unit

Safety Standards. Model Number:

Installation Job Aid for VSP 4850GTS

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

60 Watt Medical (MWLT)

Safety Standards. Model Number:

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Safety Standards. Model Number:

Safety Standards. Model Number:

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

20A DRR Module / 40A DRR Module

Safety Standards. Model Number:

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

Safety Standards. Model Number:

Universal Power Supplies

TM251MESC controller M251 Ethernet CAN

PDD-300 pulsed diode driver

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Dell Wyse 5050 All-In-One PCoIP Zero Client

TM241C40U controller M IO transistor NPN

Site~Rite Prevue Ultrasound System and Site~Rite Prevue+ Ultrasound System Technical Manual

Safety Standards. Model Number:

H-series (Rectifier Module)

TM241C24T controller M IO transistor PNP

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

TM241CE24U controller M IO transistor NPN Ethernet

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet

TF501, TF521 Terminal Bases

Installation Guide DRAFTMF4100

Installation Job Aid for VSP 4450GTX-HT- PWR+

VW49U453/6. 49" Ultra Narrow Bezel Video Wall Displays

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

TM251MESC controller M251 Ethernet CAN

Back-UPS RS APC Back-UPS RS 800VA 120V Black

User Manual. SmartWave LF Tool. PN: Revision 1.1. Copyright 2009 Bendix CVS Canada Inc.

NA502 Multiple RF Home Gateway

Philips PageWriter Touch ECG

Industrial Power Supplies

TM241CE24T controller M IO transistor PNP Ethernet

Bus Bar Protection Relay B-PRO 4000

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

LMC058LF42 compact base - 42 I/O - 24 V DC supply

TM241CE40T controller M IO transistor PNP Ethernet

TO65SS 65 SINGLE SIDED TOTEM VERTICAL DIGITAL SIGNAGE DISPLAY

4700 Series RAID-Enabled Industrial PCs DS _RAID(C)

Constant Voltage Mode

CompactBlock Guard I/O EtherNet/IP Safety Modules

TO65DS. 65" TOTEM Displays

PMX09 DATA SHEET FEATURES A PORTABLE 9-SLOT 3U PXI EXPRESS CHASSIS WITH INTEGRATED DISPLAY AND KEYBOARD

TECHNICAL DESCRIPTION

3190 Series Touch Screen POS Workstation

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

Enclosed Power Supplies

TM241CE40R controller M IO relay Ethernet

MINER-S Station Controller

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Version 1.0 December isappos 4 / isappos 5 Scanner Jacket

350A Series MDS 350 A D 701 A A. Technical Datasheet Medical ATX Power Supply ATX 12V 1U Power Supply

IF84M60. 84" Interactive Flat Panel Displays

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Safety Standards. Model Number:

TM241C40R controller M IO relay

Safety Standards. Model Number:

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

TALON Network Manager- 2 & 6 Express

Installation Job Aid for Ethernet Routing Switch 3600 Series

DATASHEET. Ultra Capacitor Charger, UCC-4

Uninterruptible Power Supplies

Safety Standards. Model Number:

Transcription:

Summary The Ultraview SL 2400 is a compact monitoring system with a 10.4-inch resistive touchscreen display. Dual-battery slots allow this monitor to be used in transport, as well as at the bedside. The SL2400 includes one single-high module slot that is compatible with all Spacelabs modules. When used with the 91493 Integrated Module Housing, two additional parameter modules are supported. Features User Interface All controls are on-screen touch keys, with the exception of the power (ON/OFF) key; optional controls include mouse, keyboard, and remote control Display Color thin film transistor (TFT) resistive touchscreen liquid crystal display (LCD) Resolution 640 480 pixels Size 21.11 cm (8.31 inches) wide 15.85 cm (6.24 inches) high Trace Height 4.2 cm (1.65 inches) 6 cm (2.36 inches) Sweep Speed A variety of speeds are available under module control Parameter Capacity Provides three times the number of waveforms purchased, up to a maximum of 18 parameters Alarm Limit Review Provides a snapshot view of bedside alarm limits for all active parameters; this feature is only available with specific Ultraview SL modules Built-in Alarm Light Provides multi-color visual alarm notification based upon alarm severity 31.24 cm (12.3 inches) 10.4 in 26.42 cm 27.05 cm (10.65 inches) Depth: 16.51 cm (6.5 inches) Weight: 5.5 kg (12.1 pounds) with two batteries and recorder

Trends Displays 24 hours of graphic and tabular trend data for any bed on the network Graphic 1-, 2-, 6-,12-, or 24-our segments; data is stored in 1-minute resolution Tabular Time increments of 1, 5, 10, 15, or 30 minutes; 1, 1.5, or 3 hours Interactive Networking Provides interactive view, control, review and recording capabilities for parameters, trends and calculations displayed from any monitored patient on the network Remote View/Alarm Watch Provides a single parameter view for any monitored patient on the network (Remote View), or in the event of an alarm (Alarm Watch) from up to 32 selected patients. Data from any monitor may be simultaneously viewed by up to 16 network devices (monitors or workstations). Configurable Patient ID Biomed-level administration tool; enables configuration of the patient demographic information displayed in public views. For example: Remote View, Alarm Watch, Full Bed Review, and central monitor waveform zones Barcode Scanner Support Provides support for using thirdparty barcode scanners for entering patient demographic data into a patient s Admit Record (limited to 128 ASCII characters). USB-compatible bar code scanners must be purchased from the manufacturer. Power An external direct current (DC) power supply provides power to the monitors and up to three Flexport system interfaces Advanced Power Management Maximizes battery performance during transport; includes battery fuel-gauge Connectors Three standard USB 1.1 connectors (keyboard, mouse or barcode scanner), synchronous data link control (SDLC for Flexport systems or module housings), RJ45 (10/100BaseT Ethernet), remote alarm light, VGA output (video), RS-232 serial connector Network Communication 10/ 100 BaseT modular connector (RJ45) provided; supports interactive bed-to-bed communications Options 04 Four display zones 06 Six display zones D Perioperative; provides customizable, user-specific display setups and start case/end case functions Note The SL2400 does not support the 91388 Remote Display Controller. N Vital Signs Calculations (Hemodynamics, Oxygenation, Ventilation, and Renal) O Drug Dose Calculations Q Data Shuttle (for use with selected modules only) supports transfer for up to 24 hours of the database from the monitor, including continuous and episodic events, and trend information for all parameters monitored by modules and Flexport system interfaces R Patient Data Logger; presents an ASCII data stream of patient name and vital sign data to the serial port in a pre-defined format U Dual Channel Internal Recorder Printing Method Thermal array print head Resolution Eight dots per mm (vertical) and 32 dots per mm (horizontal) at 25 mm per second sweep speed Paper Heat-sensitive roll of paper, 50 mm wide 30 m long Prints Manual and automatic alarm recordings for waveforms and vital sign data, trends, calculations; full annotations are included Frequency Response Determined by the parameter recorded Paper Speed 1.56, 3.12, 6.25, 12.5, 25, and 50 mm per second (depending on the monitor sweep speed selected) Alarm Record Records any parameters in an alarm state when alarm recording is active Auto Run 20 seconds or duration of alarm violation (whichever is longer) Controls CONVERT TO CONTINUOUS, STOP RECORDING, SLOW ON/OFF, PRINTER ON/OFF

Indicators Paper out, unit off Record Enables selection of up to two active monitor channels plus trends. Z Wireless Ethernet Communication; provides 2.4 GHz 802.11b communication; wireless Ethernet will send one to six waveforms and numeric vital signs to the Ultraview Care Network ; requires site qualification survey to ensure adequate performance Product Specifications Classification MDD Class IIb EN 60601-1 Class 1 Requires outlet with safety ground (Protective Earth) conductor Electrical Specifications Rated for continuous operation CISPR11, Group 1, Class B Suitable for use in domestic establishments connected to a low-voltage supply network Mains Power 100 to 240 VAC, 50 to 60 Hz, 2 A Batteries One or two 12-volt (2.45 Ah NiMH) batteries may be used, providing 2.5 hours of operation with two batteries (TFT display), for up to 600 charge/discharge cycles; Physical Dimensions Height 27.05 cm (10.65 inches) Depth 16.51 cm (6.5 inches) Environmental Requirements Storage Temperature -25 to 60 C (-13 to 140 F) Humidity 95% (non-condensing) Electromagnetic Compatibility EN 60601-1-2: 2001 Emissions (CISPR 11) EN 55011, Class B operating time is dependent on configuration and usage; 1.5 hours are required to charge batteries to 100% of capacity with AC connected to rear panel and mains switch in the OFF position; 3-hour charge Width 31.24 cm (12.3 inches) Altitude 0 to 12,192 meters (0 to 40,000 feet) Operating Temperature 0 to 50 C (32 to 122 F) EN 61000-3-2 Harmonics EN 61000-3-3 Flicker time required with the mains switch in the ON position. Isolation Chassis leakage current meets AAMI, UL 60601-1, CSA Std. C22.2 No. 601.1, and IEC 60601-1 standards Weight 5.5 kg (12.1 pounds) with two batteries and recorder Humidity 95% (non-condensing) Altitude 0 to 4,572 meters (0 to 15,000 feet) Immunity IEC 61000-4-2 ESD, 8 kv contact/15 kv air

IEC 61000-4-3 RF fields, 20 volts/meter, 80 MHz to 2.5 GHz IEC 61000-4-4 Burst, 1 kv data and I/O ports/2 kv power ports IEC 61000-4-5 Surge, 1 kv differential/ 2 kv common mode IEC 61000-4-6 Conducted RF, 3 Vrms 150 khz to 80 MHz IEC 61000-4-8 Magnetic field (50/60 Hz), 60 Amps/meter IEC 61000-4- 11Power quality, voltage, and frequency variations Accessories P/N 010-1114-01 Dual external NiMH/SLA battery charger, 100 to 240 V P/N 146-0055-00 Rechargeable NiMH battery 90360-01 Remote keypad P/N 016-0369-00 Bedrail hook/quick release mounting plate P/N 010-1622-00 Mouse, USB P/N 010-1621-00 Keyboard (U.S. English only; other keyboards are available for use outside the U.S.) P/N 119-0479-00 Power supply* Height 7.74 cm (3.05 inches) Length 12.8 cm (5.04 inches) Depth 4.19 cm (1.65 inches) Weight 0.54 kg (1.2 pounds) * This accessory is included. A variety of GCX-brand mounting and mobility solutions are available from Spacelabs or GCX directly. Documentation Ultraview Operations Documents CD-ROM (P/N 084-1101-xx) Spacelabs Medical Service Documents CD-ROM (P/N 084-0700-xx) Spacelabs Medical Supplies and Accessories Catalog CD-ROM (P/N 084-1201-xx)

Regulatory Approvals C US CSA certified to IEC CB Scheme. Meets IEC 60601-1, CSA C22.2 No. 601.1, and UL 60601-1 for electrical safety. 0123 Meets EN 60601-1. CE marked in accordance with the Medical Device Directive 93/42/EEC. 0168! The embedded 802.11b (2400 to 2483.5 MHz) wireless option (Z) of this device complies with part 15 of the FCC Rules, with RSS-210 of Industry Canada, and is CE marked in accordance with the RTTE Directive 1999/5/EC. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The radio-transceiver may only be used for Wireless Local Area Network (WLAN) operation within a medical facility. It is not intended for home or vehicle use. Changes or modifications not expressly approved by Spacelabs Medical will void the user s authorization to operate this equipment. To comply with RF safety Specific Absorption Rate (SAR) requirements, the user must ensure that the monitor, which contains the radiating element of the antenna, is located at least 20 cm (8 inches) away from a person s head or body. Ultraview, Ultraview SL, Ultraview Care Network, Flexport, and Data Shuttle are trademarks of Spacelabs Medical, Inc. Brands and product names are trademarks of their respective owners. www.spacelabshealthcare.com 061-1406-00 Rev. J 10/06