CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

Similar documents
RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RXTP ROOM TEMPERATURE

RТTH DUAL ROOM SWITCH

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

RXTH DUAL ROOM SENSOR / SWITCH

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

B63/ NS MS. EtherNet/IP LINK

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

LED W RGBA User Manual

NL-324BTR User manual (60706)

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

SolConeX extra-low voltage flange socket

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Fog machine PT Users Manual

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

1. Safety Precautions

Flexoled FTP3HP RGB LED DMX Driver

User Manual Please read the instructions carefully before use

MATRIX LED LED User Manual Please read the instructions carefully before use

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Configurable Network Paging Console. Product Instructions. Model: X-NPMI

INSTALLATION MANUAL. Gateway option box EKLONPG EKBNPG

CMSA-100 Manual. Cinema Media Server Automation

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Instruction Manual. T3110 T3110L T3110Ex

User Manual. Printer P-52RUE

Crossfire. User Manual. Order code: EQLED061

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

CP 64 BD15 CP 64 PD15

DMX LED Starcloth Systems

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

JanusRAID SA-6692J Hardware User Manual

Expansion module EM-BAC-MOD-01. Installation manual

OZONE SWITCH Model OS-6. OS-6 Features

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Operating Manual. icam100

FTP1 Single Channel LED DMX Driver

Deckblatt von Marketing / Foto fehlt

Lynx Pro Audio S.L. Valencia, Spain

Powergate³ User. Instruction manual and user s guide

RS232C/RS485 Data can be easily monitored by LAN

ERF910. RF Repeater. Synco living

7032 Digital-Analog Multimeter

i-reader User manual

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Installation manual plugs and connectors with screw connection (16/32 A)

Phase comparator. User manual Document version: 02i00 Update:

TOUPCAM QUICK GUIDE INSTALLATION MANUAL

OPERATING INSTRUCTIONS

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Operating instructions. Speed monitor D / / 2014

HV-CS kv Edge Mount Triaxial Jack

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

IPCB42501 / IPCB42551

CS2 DMX Distribution Splitter

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

RS Stock No Instruction Manual RS Input Data Logging Thermometer

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

RGB Power Batten. User Manual. Order code: EQLED032

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Product manual plug, sockets and coupler 16 A.- Z0251

Powergate3+ Decoder. Instruction manual and user s guide

Operating instructions. Switching amplifier DN0210 DN / / 2015

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

MC 11 EB-2 Power supply cabinet with external bus, AC version

UV Power Flood. User Manual. Order code: EQLED029

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

MDM 011-Z1 Regen Resistor

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

LCU-2S Liquid Supply System User Manual English

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Simple but elegant look and ease of installation make it ideal for various industrial applications.

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

TB-1230 QW. User Manual Please read the instruc on carefully before use

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Carbon Monoxide Sensor - ModBus

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

F1000 User's Manual. (Version: V1.01)

PF LED Profile. User Manual

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

Analog Input/Output Modules

Transcription:

USB CONVERTER Operating instructions

Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING AND CONNECTIONS 5 OPERATING INSTRUCTIONS 5 VERIFICATION OF INSTALLATION 8 MODBUS REGISTER MAPS 8 TRANSPORT AND STORAGE 9 WARRANTY AND RESTRICTIONS 9 MAINTENANCE 9 2-6

SAFETY AND PRECAUTIONS Read all the information, the datasheet, mounting and operating instructions and study the wiring and connection diagram before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications of the product are inadmissible. The product should not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Long-term exposure to chemical vapours in high concentration can affect the product performance. Make sure the work environment is as dry as possible; avoid condensation. All installations shall comply with local health and safety regulations and local electrical standards and approved codes. This product can only be installed by an engineer or a technician who has expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts; always treat the product as if it is live. Always disconnect the power supply before connecting, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use appropriate wire size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and these should be disposed of in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact our technical support or consult a professional. 3-6

PRODUCT DESCRIPTION The CNVT-USB-RS485 is a self-powered Modbus RTU (RS485) to USB converter. The Modbus RTU serial information is automatically converted to serial information on a USB virtual COM port in both transmitted and received communication. INTENDED AREA OF USE To connect any Sentera device with Modbus RTU communication to a computer To connect Sentera devices to the 3SModbus software suite for monitoring and configuration For indoor use only! TECHNICAL DATA STANDARDS Easy plug & play installation LED indication for receiving and transmitting signals Integrated connections for terminal block in enclosure Compatible with USB 1.1 and 2.0 Installs as a standard Windows COM port Supply: USB powered Input: USB Type A Output: Modbus RTU (RS485) A, /B and GND Protection class: IP30 Enclosure: polycarbonate, colour: transparent Operating ambient conditions: temperature range: 0 50 C rel. humidity: 5 85 % rh (non-condensing) Storage temperature: -10 60 C Low Voltage Directive 2014/35/EC EMC Directive 2014/30/EC: EN 61000-6-2: 2005/AC:2005, EN 61000-6-3:2007/A1:2011/AC: 2012, EN 61326-2-3:2013 WEEE Directive 2012/19/EC RoHs Directive 2011/65/EC WIRING AND CONNECTIONS Connections A RS485 signal A /B RS485 signal /B GND Ground NOTE The GND terminal should NOT be used! Connecting equipment with a GND that is not common with your computers GND will damage your USB port. Therefore it is strongly recommend NOT to use the GND terminal. 4-6

OPERATING INSTRUCTIONS Before you start connecting the CNVT-USB-RS485, read carefully Safety and Precautions. Then follow these steps: 1. Before you start using the CNVT-USB-RS485 converter, you need to download the free 3SM Center application from Sentera s website: https://www.sentera. eu/3smcenter/index/eng and install it on your computer. 2. Connect the A signal of the 3SModbus device to the A terminal of the CNVT-USB- RS485 3. Connect the /B signal of the 3SModbus device(s) to the /B terminal of the CNVT- USB-RS485. 4. Plug the converter into the USB port of your computer. It will be recognised and installed automatically once the connections are complete (see Fig. 1). Fig. 1 Example of connecting Sentera s VFSC9 electronic fan speed controller to a computer via CNVT-USB-RS485 CNVT-USB-RS485 VFSC9 A /B GND 5. Connect the 3SModbus device(s) which will be monitored and / or configured to the power supply network. 6. Start the 3SM Center application and click on the 3SModbus button. Once you start the application, the computer will scan and automatically recognize the connected device (see Fig. 2). Fig. 2 3SMobdus application 5-6

VERIFICATION OF INSTALLATION After the communication between the computer and the 3SModbus device(s) has been established, the LEDs on the PCB of the converter should blink - the red LED indicates that packages are received and the green indicates that packages are transmitted via Modbus RTU. If this is not the case, check the connections. Fig. 3 Modbus communication indication TRANSPORT AND STORAGE Avoid shocks and extreme conditions. Stock in original packing. WARRANTY AND RESTRICTIONS Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. MAINTENANCE In normal conditions these controllers are maintenance-free. If soiled, clean with a dry or damp cloth. In case of heavy pollution, clean with a non-aggressive product. In these circumstances, the unit should be disconnected from the main supply. Pay attention that no fluids enter the unit. Only reconnect the controller to the main supply when it is completely dry. 6-6