FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

Similar documents
FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX2-CHILLER. Digital Control. Operations Manual

FX 2 Instruction Manual

INTRODUCTION. FX-1 Operations Manual. Standard Features. Optional Features. Read This Manual Completely Before Proceeding!

ARCTIC AIR DC OLED. Digital Control Operations Manual

AirNet. CAN to Ethernet Adapter Setup Manual

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Installation & Operation Guide

Tempco Instruction Manual

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

LTEC Heat Pump DDC Controller

Resolver to Digital Expansion Board

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Integrated Battery Control System LBCS Step-by-Step Setup Guide

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

clarity 3 Programmable Controller

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BCM2 Series Branch Circuit Monitors Quick Setup Guide

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

ETM-2050/ETM-2051 Service Manual

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

SINGLE READER EXPANSION MODULE

COND. A ENABLE RELAY CONTACT COOLA ENABLE 24 VAC. RATING IS 1 AMP COND. B ENABLE COOL B ENABLE.

TECHNICAL PRODUCT DATASHEET

H7625A, H7635A Humidity/Temperature Sensors

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Master Pulse Reference/ Isolated Pulse Follower Expansion Board

Digital Lighting Systems, Inc.

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

BA/BS4S Temperature Sensor Installation & Operating Instructions

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

R325P Single Axis Driver

Modular Room Control (MRC) Series Expansion Board

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number

Satellite INSTALLATION GUIDE

DIN Molded Cable Assemblies

KOBOLD TDA Series Digital Temperature Transmitter

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

Vector Drive - Troubleshooting Guide

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

FX Input/Output (I/O) Modules XM07 and XM14

Dual Digital Module Technical Guide

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

MicroTech Absorption Gateway for Absorption Chillers

LTEC Unit Ventilator DDC Controller

MR52 READER INTERFACE

5504 Thermocouple Analog Input Module

CS5100DV Tech Sheet. Cal Spas. System PN System Model # VSP-CS5100DV-BCAH Software Version # 46 EPN # 3288

Model 7705 Control Module

XT-9100 Technical Bulletin

Contents. Please read and remember the following warnings before using the RELAYplate:

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide

VS515Z Tech Sheet. Balboa Instruments. System PN System Model # VSP-VS515Z-YCAH Software Version # 43 EPN # 2816

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Installation Instructions for UL Rev A

THE CTB08D LIGHT CONTOLLER

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Installation & Operation Guide

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

MicroTech 2000 Water Source Heat Pump Unit Controller

Unity Control Circuit Board As of

VG-305A AC Traffic Light Controller Kit

JR3 EXTERNAL SENSOR ELECTRONICS WITH SERIAL DATA OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

MANUAL INSTALLATION. Multi-Variable Monitor. MVM Series. Issue Date: 02/07/ Price Industries Limited. All rights reserved.

Classic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers

ADVANCED MICRO SYSTEMS

JR3 EXTERNAL SENSOR ELECTRONICS WITH ANALOG OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

AutoMax Network Communication Option Board for use with GV3000/SE AC Drives M/N 2AX3000

JNIOR Series 4. A Network I/O Resource Utilizing the JAVA Platform. JNIOR Series 4 with 4 Relay Output Expansion Module. Version 5.

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

6222 Two Door Module Technical Operations Manual

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

INSTALLATION INSTRUCTIONS

2. Site Planning lists the prerequisites and physical requirements for installing the 289H M LSS monitor.

4-step Chiller and Heat Pump Controller

7. PCB AND FUNCTIONS

P216 Series Condenser Fan Speed Controller

PMDX Axis Breakout/Motherboard for Gecko Stepper Motor Drivers User s Manual

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

Transcription:

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601

Table of Contents Introduction... 4 Jumper settings... 5 Systems with EasyStart... 6 Contactors... 6 Capacitor Selection... 6 Initial Starts... 6 Forcing EasyStart to relearn... 6 Additional EasyStart Jumper Usage... 7 Normal... 7 Re-learn... 7 Default... 7 Disable... 7 DC Fan Option Board... 8 Fan connections... 8 CAN Bus Systems... 9 Basics... 9 Wiring the CAN bus... 9 Wiring Diagrams... 10 Board and Firmware revisions... 10 Wiring Diagram Identification... 10 Using Contactors... 11 Checking Contactors... 11 Installing Load Resistors... 11 Using Solid State Relays (SSR)... 12 Using a Pump Relay with a Chiller... 12 Rev I and Earlier... 13 Air Handler (AH): Rev I and Earlier PCB... 13 Direct Expansion (DX) Wiring: Rev I and Earlier PCB... 14 Fresh Air Makeup Unit Wiring (FAMU) Rev I and earlier PCB... 15 EasyStart Wiring: Rev I and Earlier... 16 Chiller Rev I and Earlier... 17 Rev K PCB... 18 Air Handler (AH) Wiring: Rev K PCB... 18 May 24, 2017 2 Revision 1.09

Direct Expansion (DX) Wiring: Rev K PCB... 19 Fresh Air Makeup Unit (FAMU) Wiring: Rev K PCB... 20 EasyStart Wiring: Rev K PCB... 21 Rev L and M PCB... 22 Air Handler (AH) Wiring: Rev L and M PCB... 22 Direct Expansion (DX) Wiring: Rev L and M PCB... 23 Fresh Air Makeup Unit (FAMU) Wiring: Rev L and M PCB... 24 EasyStart Wiring: Rev L and M PCB... 25 High Current and DC Fan Wiring: Rev L and M PCB... 26 Chiller Control with EasyStart Rev L and M PCB... 27 Chiller Control Rev L and M PCB... 28 Specifications... 29 General:... 29 Applications... 29 Direct Expansion (DX)... 29 Air Handler (AH)... 29 Fresh Air Make Up Unit (FAMU)... 30 Display and Sensor Cable... 30 CAN bus wire:... 30 COPYRIGHT... 31 2016 Micro Air Corporation, All Rights Reserved... 31 May 24, 2017 3 Revision 1.09

Introduction The FX-2 control board platform is a versatile control interface that supports a variety of displays and system configurations. Among the supported configurations are direct expansion (DX), air handler (AH), fresh air makeup unit (FAMU), EasyStart, and chiller control. The table below lists the compatible displays and the available options for each. DX and AH are hardware selectable options in compatible displays. FAMU is a software compatible option in compatible displays. It can function in both DX and AH systems. EasyStart is a factory installed option that must be ordered with the FX-2 power supply. It reduces compressor starting current by controlling start characteristics. EasyStart can be used in systems where current supply is marginal or to reduce flickering of lights during starts. Chiller is a low cost chiller control that utilizes special software in a FX-2 Joystick display and a standard FX-2 control board. The chiller provides only basic water in based temperature control and standard fault detection along with freeze detection. Boards are operated as standalone systems and do not have run time equalization in multi-unit systems. Modes / Options Compatible Displays FX-2 Touch Easy Touch FX-1 FX- MAXX DX AH FAMU EasyStart ** ** Humidity Reduction Mode CAN Chiller DC Fan option board ** Limited function. FX-2 Joystick May 24, 2017 4 Revision 1.09

Jumper settings Hardware jumpers are provided on the FX-2 control board to provide additional functions. Printed circuit board (PCB) revision I and earlier have jumpers that must be set for proper display operation. Revision K and above automatically detect the display and do not have display setting jumpers. All boards have the configuration jumpers shown in the configuration table below. Display Selection (rev I and earlier PCB): JP9 JP11 Usage OLED OFF OLED OLED display. FX-MAXX ON FXMAX FXMAX display. Configuration (all revisions): System JP7 JP8 Usage AH ON OFF ALL DX OFF ON With low Freon pressure switch. DX ON ON No low Freon pressure switch. FAMU-AH ON OFF Air Handler FAMU-DX ON ON No Low Freon FAMU-DX OFF ON Low Freon Chiller ON ON Chiller 1 with No LP Switch Chiller ON OFF Chiller 1 with LP Switch Chiller OFF ON Chiller 2 with No LP Switch Chiller OFF OFF Chiller 2 with LP Switch May 24, 2017 5 Revision 1.09

Systems with EasyStart Contactors Systems with compressors over 24K BTU or greater than 1.5 HP must use a contactor. See the wiring diagram for details. Capacitor Selection Best start performance, in most cases, can be achieved by using the start capacitor values found in the table below. BTU Rating Start Capacitor Size 37K to 48K 189 to 227uF 25K to 36K 130 to 156uF 12K to 24K 88 to 106uF 5K to 11K 64 to 77uF Run capacitors should be sized according to the compressor manufacturer s recommendations. Both capacitors often see voltages much higher than the applied line voltage. Select capacitors that have the appropriate voltage rating for your system. Initial Starts EasyStart has adaptive software that collects data during the first five starts of the compressor. EasyStart uses this data to determine the best starting characteristic for minimum start current delivered to the compressor. It is highly recommended that these starts be done with a stable power source such as shore power. Start the compressor five times after installation on shore power to allow EasyStart to learn about the compressor. No further setup is required. Forcing EasyStart to relearn EasyStart may be reset to perform the learning process. This is used when changing compressors or if instructed by to manufacturer to do so. Follow these steps below to complete this process. Refer to the FX-2 DX EasyStart wiring diagram for jumper position identification. 1. Remove AC power 2. Short pins four (4) and six (6) on JP1 with the black jumper. 3. Restore AC power for 30 seconds. 4. Remove AC Power. 5. Remove the jumper from pins four (4) and six (6) on JP1 and place it over pins three (3) and four (4). 6. Restore AC power and start the compressor five times. EasyStart will relearn the start characteristics of the compressor. May 24, 2017 6 Revision 1.09

Additional EasyStart Jumper Usage The pin header JP1 on the EasyStart top board is used to configure EasyStart. The white block shown by the arrow one indicates pin number 1. Other pins are identified as shown in relation to pin 1. Caution: Do not place jumpers on JP1 except as indicated. Normal: Most operation should be done without a jumper installed on JP1 or with the jumper installed across pins 3 and 4. Re-learn: If a compressor, start capacitor, or run capacitor is replaced, place a jumper on pins 4 and 6. Cycle power on then off again. Remove the jumper and place it across pins 3 and 4. Cycle the compressor on then off five times to complete the setup. Be sure to allow enough time for pressure to bleed off between cycles in systems without a reversing valve. Default: A compressor may be operated with a factory defined start characteristic. This may not be the optimal start for the connected compressor and is generally used for factory diagnostics. Install a jumper across pins 1 and 3 for this configuration. No optimization is done with this setting. Disable: This setting disables the microprocessor on the board so no operation can occur. Use this setting on an FX-2 system if you are installing a compressor with its own start device and are not using EasyStart. In this case you must follow the wiring diagram for a standard FX-2 system. Install a jumper across pins 5 and 6 for this configuration. May 24, 2017 7 Revision 1.09

DC Fan Option Board The PCB-361 option board is factory installed on the FX-2 control board. This option allows up to four PWM controlled DC fans to be connected. Speed control for each fan is individually adjustable in the programmable parameters on compatible displays. Fan connections Each fan is connected by three wires to the control board. Connect the control wires to their corresponding terminals on the option board. The + terminal is connected to the DC fans +10 volt output. The - terminal is connected to the DC fans ground control wire only. Do not connect the GND wire to an AC ground. The S terminal is connected to the DC fans 0-10V signal wire. Connect the DC fan s AC input directly to the AC line input. All other connections to the FX-2 control board are as they would be in a normal installation. Notes: The FX-2 control board provides an output for a triac driven fan connected to Fan L1 and Fan L2 on the FX-2 control board. When connected, the fan will follow the speed control for Fan A on the DC fan option board. Do not connect the DC fan power source to the Fan L1 terminal on the FX-2 control board. Power for the DC fan must be supplied by the AC L1 and AC L2 terminals. The DC fan option board cannot be used with combination humidity and air sensors. Improper or erratic operation can result if combination humidity and air sensors are installed. EasyTouch humidity control feature is not available with the DC option board installed. May 24, 2017 8 Revision 1.09

CAN Bus Systems Basics The CAN system (Computer Area Network) is a communications protocol system that facilitates communication between electronic controls. Controls are connected to each other to form a network. Typical controls in a network could include ice makers, chilled and heated water systems, air handlers, and direct expansion systems. The physical connection is called a bus and consists of a minimum of two wires connected to each device. Up to 127 controls including a computer connection may be connected on one bus. CAN bus exchange protocol follow the ISO-11898 standard for CAN specification 2.0 Part B. System integrators can find the message contents defined in the Microair CAN protocol specification available from http://www.microair.net. Wiring the CAN bus The bus consists of a two or three wire connection to each device in the system. Wires are connected to each control in a sequentially wired, daisy chain style connection. Wire used for the CAN bus must be rated as indicated in the specifications section of this document. To wire the system, first determine which devices will be at each end of the system. All other devices will be connected between these two devices. Wire the bus starting with a selected end device. Connect wires to CAN-L and CAN-H (and ground if used) on this device then connect the other end of these wires to the second control in the system. Connect wires in parallel to the wires connected to the second device to the third device in the system. Continue making connections until all controls are connected. Always connect GND to GND, CAN-L to CAN-L, and CAN-H to CAN-H. Never place more than two wires in any terminal connection. The control at each end of the bus must have a terminator installed. The terminator is a two pin jumper located on the circuit board next to the CAN connector labeled CT. Place this jumper only on the first and last control in your system. During installation, write down the serial numbers of each device connected and description of the location they are in or are responsible for. This will help to simplify system setup later. May 24, 2017 9 Revision 1.09

Wiring Diagrams Board and Firmware revisions This manual makes reference to FX-2 control board printed circuit board (PCB) revisions. The PCB revision is found along the edge of the printed circuit board in white silk screened lettering and starts with PCB-360. PCB-360-00J indicates a revision J circuit board. Firmware revision is marked on a label placed on the microcontroller integrated circuit on revision L circuit boards. Previous revision boards have no software revision markings and can only be determined by contacting Microair. Wiring Diagram Identification The included wiring diagrams are organized by board revision and system type. To find the correct diagram for your system, first identify the control board revision used in your system. Use this identifier along with the type of system you have (direct expansion (DX), air handler (AH), fresh air makeup (FAMU), EasyStart) to find the correct wiring. Systems may not include all features shown in the wiring diagrams. Colors are provided for clarity and may not reflect the colors used in your system. May 24, 2017 10 Revision 1.09

Using Contactors Circuitry on the board may adversely affect the operation of contactors by holding a contactor on when it should be off. This condition should be verified whenever a contactor is used by following the procedure below. WARNING: AC LINE VOLTAGE CAN BE DANGEROUS OR FATAL IF IMPROPERLY HANDLED. The following steps involve working directly with AC line power and must only be performed by trained service personnel. Checking Contactors 1. Disconnect the contactor load from the contactor. 2. Disconnect the display by removing the plug from the display jack on the FX-2 control. 3. Apply power to the board from the AC mains power source. 4. Depress the contactor armature using a non-conductive hand tool. If the contactor armature releases quickly without any noticeable sticking or hesitation, then no load resistors are required and you can reconnect the contactor load and display. 5. If the armature does not release or sticks before releasing, add load resistors as described in the next section Installing Load Resistors. Installing Load Resistors Installers may add loading resistors of 62k ohms 2 to 3 watts, to the contactor coil to prevent contactors from remaining on. One load resistor is also required for Chiller controls when a pump relay is connected to the fan output. These resistors are available from standard electronics outlets or from Microair directly. 1. Disconnect AC power from the board. 2. Add one or two 62K ohm 2 to 3 watt resistors in parallel to the contactor coil. 3. Recheck the contactor as described in the Checking Contactors section. 4. If adding six or more resistors does not significantly reduce sticking or hesitation, contact Microair for additional assistance. May 24, 2017 11 Revision 1.09

Using Solid State Relays (SSR) Circuitry on the board may adversely affect the operation of an SSR by holding an SSR on when it should be off. Customers with applications using an SSR should contact Microair prior to purchase for factory modification of the board. Boards may also be returned to Microair for modification. Using a Pump Relay with a Chiller The following information is provided for identification of modified boards. Microair recommends customers call Microair and order a board specifically modified for their application needs. Improperly modified boards and other customer damages are not covered by the Microair product warranty. These modifications are valid only on revision L printed circuit boards. C35 C28 120K 2W Remove C35 and C28 for contactor or pump relay connected to fan output. Install a 120K 2W resistor on fan L1, L2. May 24, 2017 12 Revision 1.09

Rev I and Earlier Air Handler (AH): Rev I and Earlier PCB May 24, 2017 13 Revision 1.09

Direct Expansion (DX) Wiring: Rev I and Earlier PCB May 24, 2017 14 Revision 1.09

Fresh Air Makeup Unit Wiring (FAMU) Rev I and earlier PCB May 24, 2017 15 Revision 1.09

EasyStart Wiring: Rev I and Earlier May 24, 2017 16 Revision 1.09

Chiller Rev I and Earlier May 24, 2017 17 Revision 1.09

Rev K PCB Air Handler (AH) Wiring: Rev K PCB May 24, 2017 18 Revision 1.09

Direct Expansion (DX) Wiring: Rev K PCB May 24, 2017 19 Revision 1.09

Fresh Air Makeup Unit (FAMU) Wiring: Rev K PCB May 24, 2017 20 Revision 1.09

EasyStart Wiring: Rev K PCB May 24, 2017 21 Revision 1.09

Rev L and M PCB Air Handler (AH) Wiring: Rev L and M PCB (Rev L shown. Rev M has different style DC fan jack.) May 24, 2017 22 Revision 1.09

Direct Expansion (DX) Wiring: Rev L and M PCB (Rev L shown. Rev M has different style DC fan jack.) May 24, 2017 23 Revision 1.09

Fresh Air Makeup Unit (FAMU) Wiring: Rev L and M PCB (Rev M shown. Rev L has different style DC jack.) May 24, 2017 24 Revision 1.09

EasyStart Wiring: Rev L and M PCB (Rev L shown. Rev M has different style DC fan jack.) May 24, 2017 25 Revision 1.09

High Current and DC Fan Wiring: Rev L and M PCB (Rev L shown. Rev M has different style DC fan jack.) Note: Up to two DC fans can be connected to the DC fan output. May 24, 2017 26 Revision 1.09

Chiller Control with EasyStart Rev L and M PCB (Rev L shown. Rev M has different style DC fan jack.) May 24, 2017 27 Revision 1.09

Chiller Control Rev L and M PCB (Rev L shown. Rev M has different style DC fan jack.) May 24, 2017 28 Revision 1.09

General Specifications Temperature sensor accuracy 2 F at 77 F Low voltage limit 115 VAC units 75VAC Low voltage limit 230 VAC units 175VAC Line voltage limit 250VAC Frequency 50 or 60 Hz Maximum board input current 30 Amps Minimum operating temperature 0 F Maximum operating temperature 180 F Maximum RH conditions (Board and display) 95 % Non-condensing Maximum length of the display cable 75 Feet Maximum length of the Outside air sensor cable 50 Feet Externally mounted heater or fan triac 16 Amps Application Direct Expansion (DX) Fan output MAX filtered Unfiltered Valve output MAX (Or electric heater connected to valve output) Pump output MAX Compressor output Rev J PCB and above: Heater 6 Amps 16 Amps with external Triac 10 Amps Maximum ¼ HP at 115 VAC ½ HP at 230 VAC 1HP at 115 VAC 2HP at 230 VAC 16 Amps with external Triac Air Handler (AH) Electric heater output Rev IPCB and earlier (Connected to compressor L1 and L2) 30 Amps Maximum Rev J PCB and above: Heater (see wiring) 16 Amps with external Triac 30 Amps: compressor output Valve output MAX Fan output MAX 10 Amps Maximum 6 Amps May 24, 2017 29 Revision 1.09

Specifications (CONTINUED) Fresh Air Make Up Unit (FAMU) RH measurement range 5% to 100% Electric heater output: Rev I PCB and earlier (Connected to Fan L1 and L2) Rev J PCB and above: Valve output MAX Fan output MAX Rev I PCB and earlier (Connected to Pump L1 and L2) Rev J PCB and above (Connected to Fan L1 and L2) 16 Amps Maximum 16 Amp with external Triac 10 Amps Maximum 10 Amps Maximum 6 Amps Maximum 16 Amps with external Triac Display and Sensor Cable Flat (oval) multi-conductor shielded modular type cable consisting of stranded tinned copper conductors with thermoplastic insulation and a 22 AWG stranded fused tinned copper drain wire with an overall 100% coverage aluminum/polyester shield in a PVC jacket. Five conductors are used for the sensor cables and seven conductors for display cables with 26 AWG 7/36 strand wire covered with.009in (Nominal) insulation. Adirondack wire and cable type AWC195 or similar type cable. CAN bus wire Compatibility: SAE J1939 Characteristic impedance: 120 ohms Line capacitance: < 80pF per meter at 1 MHz Wire gauge: 20 AWG minimum Specific line delay (velocity factor) : > 70% Mechanical: 2 conductors, twisted pair with shield and drain connection. Examples of acceptable wire: North Wire Data Cell J1939 Waytec CB20-11F 20 Prestolite Wire SAE1939-15 #149812 May 24, 2017 30 Revision 1.09

COPYRIGHT 2017 Micro Air Corporation, All Rights Reserved No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means electronic, mechanical, photocopying, recording or otherwise without prior written consent by Micro Air Corporation. Every precaution has been taken in the preparation of this manual to insure its accuracy. However, Micro Air Corporation assumes no responsibility for errors and omissions. Neither is any liability assumed nor implied for damages resulting from the use or misuse of this product and information contained herein. May 24, 2017 31 Revision 1.09