DOR6. Components All functions and indications are on the front of the module. Characteristics

Similar documents
Priva Blue ID Relay output module DOR4/DOR8

Priva Blue ID C-Line Mix input/output module MX34

Priva Blue ID Communication module RS485 SC44

Priva Blue ID Digital input module DI4/DI8/DI16

Priva Blue ID Analogue output module with manual override AO2m/AO4m

Priva Blue ID Communication module RS232 SC22

Blue ID Power injection module PI60

Blue ID Communication module RS485 SC44

Priva Blue ID Network module SN1/SN2/SN3/SN3t

Priva Blue ID C-Line system overview

Priva Blue ID C4 Controller with manual override C-MX34m

Priva Blue ID system overview

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

K1D012ULH cam changeover switch - 2-pole A - screw mounting

PHOENIX CONTACT Features

iologik 4000 Series (M) Modules

Model Number Structure

QUINT-PS/ 1AC/24DC/20/CO

TM3DI16 module TM3-16 inputs

K1B004TLH cam switch - 1 pole A - screw mounting

TM3DI16G module TM3-16 inputs spring

QUINT-PS/ 1AC/24DC/ 5

XPSMCMDO Digital output pairs expansion modules with screw term

RM84 miniature relays

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Model Number Structure

TM3AI4 module TM3-4 analog inputs

RXTH DUAL ROOM SENSOR / SWITCH

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

DeltaV Bulk Power Supplies

RXTP ROOM TEMPERATURE

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

em4 Accessories Digital expansions

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

K1F006ALH cam switch - 6-pole A - screw mounting

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

TM3TI8T module TM3-8 inputs temperature

Electronic timer CT-ERD.12

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

DeltaV Bulk Power Supplies

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

XPSMCMDI Input expansion module with screw term

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

TM3TI4 module TM3-4 inputs temperature

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

TM3TM3 module TM3-2 temperature inputs and 1 analog output

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

RM35TF V AC

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

QUINT-PS/24DC/48DC/ 5

Model Number Structure

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

Electronic timer CT-ERS.21

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Electronic timer CT-AHD.22

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

QUINT-PS AC/24DC/10

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

Bulletin 817 Thermistor Protection Relay

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Installation / Control Technique

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

ASI QUINT /2.4 EFD

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Voltage Current Front-mounting bracket

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

XPSMCMMX inputs 2 output pairs expansion module with screw term

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Electronic timer CT-ARS.11

TM3TI4 module TM3-4 inputs temperature

Transcription:

Priva Blue ID C-Line Relay output module Easy installation You simply click the module onto the DIN rail. The wiring connects to the module via spring terminals or screw connectors (optional). The module can also be installed in a DIN 43870 distribution box. Components All functions and indications are on the front of the module. A Priva Blue ID C-Line Relay output module controls output functions using a relay. Characteristics 6 relay outputs (5 x normally open contacts and 1 x changeover contact) switching extra-low voltage and low voltage possible switching current 3 A maximum with resistive load 24 V system power monitoring contacts on terminals are properly isolated from the rest of the system LED for status of I/O line-up LED Internal bus The system is equipped with an internal bus which is implemented to the outside as an I/O bus. The 24 VDC system power, for instance, is distributed via this bus. The communication between controller and modules also runs via the I/O bus. Controlled switching If communication with the controller fails, the outputs are set to a user-configured state. Electrically isolated make or break contacts The contacts on the terminals are isolated from the rest of the system. Legend Front A B C connections for: relay outputs 5 x normally open contact (COM+NO) 1 x changeover contact (COM+NO+NC) I/O bus module information: module name number of the module in the line-up 1

D general module LEDs Clear indication The module has general LEDs that indicate the status of the module. Line-up LED The module is equipped with a blue line-up LED. If the blue LED is continuously on, the module is in the correct place according to the configuration in TC Engineer. LED for I/O status The green LED shows the status of the I/O on the module. If the I/O on the module is working correctly, the LED will be green and on continuously. If not, and in special circumstances, the LED will flash green. Connections - relay output Legend A B line-up LED LED for status of the I/O COM NO (normally open) common contact normally open contact, open when output is not powered NC (normally closed) normally closed contact, closed when output is not powered Specifications of Priva Blue ID C-Line Relay output module General Module article description Module article number Dimensions (XYZ) Width according to DIN 43880 Mounting depth for DIN 43870 distribution box ¹ Weight Maximum power consumption Typical power dissipation ² MTBF ³ Installation Housing material Button material Number of relay outputs Priva Blue ID C-Line Relay output module 5215001 140 x 63 x 62 mm (5.6 x 2.5 x 2.5 inches) 3.5 TE (HP) (1 TE = 18 mm) 53.5 mm 0.18 kg 24 VDC: 1.2 W 1.2 W 4,380,000 hours clicks onto DIN rail can be mounted in DIN 43870 distribution box mixture of polycarbonate and ABS TPE (synthetic rubber) 6, consisting of 5 with normally open contact 1 with changeover contact ¹ measured between the front of the DIN rail and the rear of the cover plate. ² Dissipation under the following conditions: - I/O load of 50% - 50% of the LEDs on ³ The MTBF is calculated according to the Telcordia SR-332 standard Issue 3 under the following conditions: - ambient temperature: 35 50 C - supply voltage: 24 VDC - time in operation per day: 24 hours - reliability level: 60% 2

Digital relay outputs Output configuration Maximum switching voltage Maximum switching current Maximum switching voltage in USA/Canada when switching different mains voltage phases on the same module External fuse normally open contact or changeover contact (depending on output) 250 VAC 30 VDC 3 A (cosφ = 1) 125 VAC 8 A maximum Expected service life of relay contacts with cosφ = up to 250 VAC and 3 A: 300,000 switches 1 and maximum of 6 switches per minute 24 VDC and 3 A: 300,000 switches Expected service life of relay contacts with cosφ 250 VAC and 2 A AC15: 200,000 switches 1 and maximum of 6 switches per minute 250 VAC motor 370 W AC3: 300,000 switches 24 VDC and 3 A L/R 7 ms: 100,000 switches 24 VDC and 1 A DC13: 200,000 switches UL certified service life of relay contacts with cosφ up to 250 VAC and 3 A: 30,000 switches = 1 and maximum of 6 switches per minute 24 VDC and 3 A: 30,000 switches UL certified service life of relay contacts with cosφ 240 VAC and 0.5 hp motor: 1,000 switches 1 and maximum of 6 switches per minute 120 VAC and 0.25 hp motor: 1,000 switches B300 pilot duty rating: 6,000 switches Maximum switching frequency Fail-safe 6 times per min. if communication with the controller fails, the outputs are set to a user-configured state Indication (for modules with manual override) green/red LEDs for status of outputs (colour is adjustable) orange LED for status of control (automatic or manual) red alarm LED Controls (for modules with manual override) buttons for manual operation to control connected equipment: 0: relay off A: automatic or manual control 1: relay on General specifications of controllers and modules System power supply Requirements The system power supply for the controllers and Mix I/O modules must meet the following requirements. Output voltage Insulation Type of power supply 24 VAC ± 25%; 50/60 Hz ± 5 % 24 VDC ± 10% double insulation between input and output for UL916, CSA C22.2 No. 205: UL listed / CSA certified Class 2 extra low output voltage power supply 3

Housing IP code Flammability class Recycle code Colour Type of device IP20 (IEC 60529) V-0 (UL 94) 7 housing: white (RAL9001) and blue (NCS S 1560-R90B) connections and connectors: black (RAL9011) open type equipment for: indoor use only pollution degree 2 environment Installation and connection Installation Type of DIN rail Connector type for power supply and I/O Permitted core cross section area Strip length/connector length (terminal block) Strip length/connector length (screw connector) Identification of connections in control panel: accessible to authorised personnel only can be clicked onto horizontally or vertically positioned DIN rail. DIN rail installed directly on a mounting plate or floating with respect to the mounting plate in DIN 43870 distribution box 35 x 7.5 or 35 x 15 mm (height x depth), in accordance with IEC 60715 pluggable terminal block screw connectors (optional) solid:: 0.2 2.5 mm² flexible with ferrule connector: 0.2 2.5 mm² flexible with double ferrule connector: 0.2 1.5 mm² solid:: 10 mm flexible with ferrule connector: 10 mm flexible with double ferrule connector: 12 mm 8 mm Maximum length of I/O bus cable between modules 3 m Maximum length of I/O bus (total, including modules) Environment Permitted temperature inside control panel of a working system (without air flow) labelling with an explanatory abbreviation 20 m 0 50 ºC Permitted temperature during transport and storage -20 70 ºC Maximum height Permitted ambient relative humidity Shock resistance Vibration resistance Installation category 3000 m 10% 95% (non-condensing) EN 60068-2-27 (Ea) EN 60068-2-27 (Fc) II Legislation and standards Canada / USA EMC UL 916 (energy management equipment) UL 61010-1 (measurement and control equipment) UL 61010-2-201 (measurement and control equipment) CSA C22.2 No 61010-1-12 (measurement and control equipment) CSA C22.2 No 61010-2-201-14 (measurement and control equipment) CSA C22.2 No 61010-1-04 (measurement and control equipment) CSA C22.2 No 205-12 (signal equipment) in compliance with 47 CFR Part 15 Subpart B, Class B (FCC Rules) Functioning must meet two conditions: 1. The system must not cause harmful interference. 2. The system must acknowledge all interference received, including interference that may cause unwanted operations. ISM system, in accordance with Canadian standard ICES-001 4

Legislation and standards Europe Low Voltage Directive 2006/95/EC: EN 61010-1 (measurement and control equipment) EN 61010-2-201 (measurement and control equipment) EMC Directive 2004/108/EC: EN 61326-1 (measurement and control equipment) EN 61000-6-2 (generic immunity standard) EN 61000-6-3 (generic emission standard) RoHS directive 2011/65/EU in compliance with WEEE directive 2012/19/EU International International IEC IEC 61010-1 (measurement and control equipment) IEC 61010-2-201 (measurement and control equipment) The Priva Blue ID C4 C-MX34 Controller and Priva Blue ID C4 C-MX34m Controller with manual override are BTL-registered with BACnet International. The Priva Blue ID C4 C-MX34 Controller and Priva Blue ID C4 C-MX34m Controller with manual override are BACnet-certified in accordance with ISO 16484-5/6. Priva is a member of the BACnet Interest Group Europe. 5

Europe Office: UK Office: Canada Office: Your Priva partner: Priva Zijlweg 3 P.O. Box 18 2678 ZG De Lier The Netherlands T +31 174 522 600 F +31 174 522 700 www.priva.nl sales.building@priva.nl Priva UK Ltd. 34 Clarendon Road WD17 1JJ Watford United Kingdom T +44 (0)1923 813 480 F +44 (0)1923 813 499 www.priva.co.uk sales@priva.co.uk Priva North America Inc. 3468 South Service Road Vineland Station Ontario LOR 2E0 Canada T +1(905) 562-7351 F +1(905) 562-7717 www.priva.ca contact.priva@priva.ca 5001132_01.001_09-2016