MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

Similar documents
MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. ALMS20L AC / DC Lighting Controller Part number A000235

SD1306. Speed Dome IP Camera. Quick User Guide

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Install Motor Controller User Manual

Chore-Tronics Mobile Server

DCM Digital Control Modules

Plus-X 300. Installation and Operation Manual

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

FNet Repeater Installation & Operator s Instruction Manual

Universal Switch Panel USP-KEYSERVER. User Manual

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

VIP-812A DUAL NETWORKED STATION PORT

PSA200 User s Manual

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

FTC-200 X-ray Tube Controller Users Manual

CM68 4 Channel NTSC/PAL Video Decoder

TDM-170 TIMER DISPLAY

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

CA-A480-A Elevator Controller. Reference & Installation Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

TDM-150 TIMER DISPLAY

Elapsed Timer Control Panel

iconverter 2-Module Power Chassis

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

CMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1

I/O Expansion Box Installation & Operator s Instruction Manual

PIM-Mini Pulsed Current Source Operation Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Woolich Racing. USB ECU Interface User Guide

Y K Modem Module

SonicWALL CDP 2.1 Agent Tool User's Guide

CMSA-100 Manual. Cinema Media Server Automation

All the registered trademarks referred to this manual are belonging to their respective companies.

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

CM Mpixel CMOS Imaging Camera

TSD-SEQ6 Sequencer Controller

XS/SC26-2 Safety Controller. Quick Start Guide

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications

Operation Manual. Equipment. Operation Manual. Loctite RB30 Robot Camera. Part Number:

S82S (3/7.5-W Models)

Broadband Automatic Disconnect Switch. User Manual

INSTRUCTION MANUAL 4 UNIT AES SWITCH MODEL R198 S/N

Wall. No opening (Example: LA-030-W)

SECURE/NONSECURE LED SIGN USER MANUAL

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

cb 1500 quick start guide & user manual Time and Attendance Made Simple...

INSTRUCTION MANUAL CM-60. Monitor. Ultra Stereo Labs, Inc. 181 Bonetti Drive San Luis Obispo, CA Telephone

XS/SC26-2 Safety Controller Quick Start Guide

EPSON PreferredSM Limited Warranty Program for the Epson Stylus

SATA II HDD Canister KISS DA 435 Quick Reference Guide

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

FA-2448 SIX POSITION Filter Wheel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Relay Board. User Manual. 1.0, Oct 2013

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

KBMG MULTI-SPEED BOARD

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Quick Start/Installation Guide

8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

EAR K. Installation and Programming. Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

VESSEL + Todd Bracher. Installation Guide Sconce

SUPPLEMENT TO THE MDC-360C MANUAL MDC-361C. Film Deposition Controller. IPN Rev. C

SOFTWARE VERSION 3.3. CD P/N Rev. C

Installation and Operation Manual

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

PCM-7140 Pulsed Current Source Operation Manual

OZONE SWITCH Model OS-6. OS-6 Features

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

MPP1700 User s Manual

MTS-2000 USER S MANUAL

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

EPSON Preferred. Priority Technical Support. Toll-Free Phone Number. Security and Peace of Mind. On-Site Repair

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

MWC-8. Operation MWC-8 800MHz Controller Manual. Operation Manual. manmwc9.

PS8 - II. Professional Power Sequencer. User s Manual

Number of input channels

ST600-KIPRO User Manual

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

550 Watt Power Supply

Sonic Ruptor 400. User Manual

Sign-Up Timeclock Set-up Departments & Employees Troubleshooting Device Installation Warranty

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Loctite Light Intensity Monitor Part Number EQUIPMENT Operation Manual. Light Intensity Monitor. Item No Set to 100% Run Mode

Transcription:

MiT MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE OF A-LMS 24 Architectural Lighting Management System Part number A000230-xxx Manual Version 1.0 MOVING image TECHNOLOGIES, LLC. 17760 Newhope St. Fountain Valley, CA Telephone: (714) 751-7998 Fax: (714) 429-7717 www.movingimagetech.com

Manual A-LMS 24 The information in this document is subject to change without notice and does not represent a commitment on the part of Moving Image Technologies (hereinafter referred to as MIT). MIT does not assume responsibility for errors that may appear in this document. MIT or its subsidiaries, designated representatives, and any vendor are not responsible in any way for any liabilities or loss resulting from the use or misuse of this document. Copyright 2015 by MIT All Rights Reserved All copyrights and trademarks are the property of their respective owners. MOVING image TECHNOLOGIES, LLC. Fountain Valley, CA Telephone: (714) 751-7998 www.movingimagetech.com

TABLE OF CONTENTS Section Page 1. INTRODUCTION & SAFETY 2 2. GENERAL DESCRIPTION 3 3. INSTALLATION 4 4. NETWORK CONFIGURATION 6 5. A-LMS WEB INTERFACE 7 6. OPERATION 10 APPENDIX A: DIAGRAMS, PARTS LIST & WARRANTY 12 R000145 A-LMS Manual 1 v1.0 9/15

1. INTRODUCTION 1 1.1 SPECIAL NOTICES Two kinds of specific notices are used within this manual to emphasize information. 1.1.1 Warning WARNING WARNING: Indicates the presence of a hazard that can cause personal injury if the hazard is not avoided. 1.1.2 Caution CAUTION: Indicates the presence of a hazard that can cause damage to equipment. 1.2 SAFETY This device is not required to be connected to AC power in order to operate, the only danger from electrical shock with the device is related to what the user connects it to. However the unit does control lighting which has safety implications as far as national and local fire safety rules. R000145 A-LMS Manual 2 v1.0 9/15

2. GENERAL DESCRIPTION 2 The MiT model A-LMS 24 Architectural Lighting Management System controls LED lighting fixtures conforming to the IEC 60929 1.0-10VDC Architectural dimming standard. The unit is available in two models: 2-channel as standard, a 4-channel unit is also available. All versions have six scene settings plus an override, All On 100% mode for emergency or cleaning. The unit accepts scene cues from external contact closures, serial port, or a LAN port. The unit is housed in a 1U rack-mount enclosure. MiT can provide a list of LED fixtures that have been tested for compatibility with the A-LMS. Because these types of lighting fixture use a low-voltage control signal, the same model A-LMS controller may be used regardless of lighting circuit voltage: 100-277 VAC. The A-LMS unit itself operates on 12VDC, the universal power supply included may be connected to 100-240VAC. POWER MODE / STATUS SCENE CUES MiT A-LMS 24 OUTPUT CHANNELS 1 2 3 4 OVERRIDE NORMAL A RCHITECTURAL L IGHTING MANAGEMENT SYSTEM ALL ON 1 2 3 4 Figure 2-1: Outline Figure 2-2: Rear Panel R000145 A-LMS Manual 3 v1.0 9/15

3 3 INSTALLATION CAUTION: Users are urged to read this instruction manual thoroughly and understand the procedures described herein before installing the system. CAUTION: National and Local electrical codes should be observed at all times. AC lighting systems involve connection to high voltages ranging from 120V to 277V. This wiring must be done by licensed electricians or other personnel with appropriate training. The technical information in this manual is provided for use by certified electricians and other qualified personnel ONLY. 3.1 GPI Inputs A connector on the rear panel allows the connection to external switches or relays to select scenes by dry contact closures. The input pin is connected to common to activate the desired scene. The voltage on unconnected control pins is 5V and compatible with a variety of other systems, for example the Moving image Technologies M4800 AC dimmer series. The inputs on the two dimmers may be connected in parallel if you wish to control both LED 1.0-10V and 120VAC phase control lighting fixtures in the same auditorium. R000145 A-LMS Manual 4 v1.0 9/15

3.2 Output Connections There are two sets of output connectors on the rear of the unit. One connector is the 1.0-10V analog control voltage to be connected to the LED fixtures/drivers. Each channel can drive approximately 50mA current. This should easily drive 20-50 LED light fixtures that conform to IEC 60929 (usually each fixture only requires about 0.5mA of current on the control line). The other connector is a switch output for turning off the power to the lighting fixtures when the dimming level reaches the bottom end of the dimming range. This is optional, only needed if desired. See Figure 3-2 for a typical connection diagram (one channel). 3.3 Mechanical mounting Figure 3-2 Once the electrical connections are made the unit may be installed in a standard 19 equipment rack. Or the unit may be mounted to a wall if desired. In this case the rack mounting brackets may be removed from the sides. R000145 A-LMS Manual 5 v1.0 9/15

4 NETWORK CONFIGURATION 4 4.1 LAN Setup In order to issue commands to the A-LMS device via a Local Area Network you ll have to configure the IP address of the unit. The unit can be configured using Telnet or the web page interface. This section describes the Telnet method, for the web page interface see Section 5. Units are configured at the factory with the IP address set to a default value. The IP address is indicated on a label on the rear of the A-LMS chassis. Note: Please contact MiT Engineering if you would like your A-LMS unit(s) set to a specific IP address at the time of production. The IP address may be changed by the user after installation using Telnet. No special software tools are required. Procedure to set the IP Address: 1. Windows XP: From the Start menu, click RUN and enter the following: Windows: telnet x.x.x.x 9100 2. Windows 7/8: From the start menu, click RUN and type cmd, or type cmd in the Search programs and files box. When the command line window appears type the following: telnet x.x.x.x Where x.x.x.x is the IP address indicated on the label on the A-LMS chassis. 3. A login prompt will appear. Type admin and press Enter. 4. A password prompt will appear. Type admin and press Enter. 5. A /> prompt will appear. Type ipconfig -a y.y.y.y -m 255.255.255.0 and press Enter. Where y.y.y.y is the new IP address. 6. Type exit and close the command prompt window. R000145 A-LMS Manual 6 v1.0 9/15

5 A-LMS Web Interface 5 To adjust the dimming settings you must log into the A-LMS using the web interface. Open an internet browser window and enter the IP address marked on the rear of the unit (or the IP address you configured in Sec. 4). Login to the unit by entering admin in the login box and admin in the password box and press Enter. 5.1 Scene Settings page The default page is the Scene Settings. Here is where you may change the dimming levels and fade times for each scene and channel. The factory default values are shown below. If desired you may enter a name for each lighting channel, for example House, Stage, Sconce, etc. On 2-channel models only the first two channels are applicable. After making changes on this page you must click the button to Update the unit. R000145 A-LMS Manual 7 v1.0 9/15

5.2 System Settings page The System Settings tab allows you to change the IP address, the subnet mask, the name of the unit, the name of the theater, and so on. After making changes on this page you will need to click the box that says Update A-LMS. If you make changes to the IP address you will have to reboot the unit. MiT suggests putting the auditorium number or name in the Device Name field, and the name of the theater in the Location 1 field. For example ABC Cinemas Fountain Valley #456. Additional information may be added in the other Location fields if desired, but aren t required. 5.3 Configuration Management page This page allows the user to backup, restore, and reset a unit to its factory defaults. The Backup and Restore function is handy for setting all the A-LMS units in a multiplex with the same values. R000145 A-LMS Manual 8 v1.0 9/15

Clicking on Backup will open a dialogue window to prompt for the location and filename for where you wish to save the settings. Clicking on Restore will open a similar window, asking what file you want to restore from. Clicking on Reset will revert all the settings of the unit to the factory default values. You will be prompted to confirm that you want to do that. R000145 A-LMS Manual 9 v1.0 9/15

6 6 OPERATION 6.1 Front Panel Controls The controls on the front panel consist of manual pushbuttons to select desired scenes, as well as to select the emergency ALL ON mode or Resume Normal mode. The LEDs indicate when the unit is in the Emergency or Normal mode. Scenes 1-4 each have their own selection button. To select Scene 5, press buttons 1 and 4 simultaneously. To select Scene 6 press buttons 2 and 4. The indicator LEDs on the buttons will reflect the same pattern, i.e. for Scene 6 the LEDs on buttons 2 and 4 will remain illuminated. 6.2 Remote Operation Scene cues may be received by the GPI input connector, the Serial connector, or the LAN connector. The GPI digital inputs accept switch or relay closures as described in Sec. 3.1. To use the serial or LAN inputs to receive scene cues you will need to send ASCII text strings from the controlling device. To send scene cues to the A-LMS via the LAN connection, in addition to configuring the desired IP address described in Sec. 4 or 5, you will need to establish a TCP/IP connection to the Host address (192.168.1.xxx or other IP address that you configured), using the port of 9100, then send the appropriate text string. See Table 6-1 for the commands accepted. Table 6-1 GPI Input Function Desc LAN / Serial Command String 1 Activate Scene 1 settings SCENE1 2 Activate Scene 2 settings SCENE2 3 Activate Scene 3 settings SCENE3 4 Activate Scene 4 settings SCENE4 5 Activate Scene 5 settings SCENE5 6 Activate Scene 6 settings SCENE6 7 Exit Emergency mode, return to last scene EMERG-OFF 8 Activate Emergency mode, all outputs on full EMERG-ON - Report status and health of A-LMS STATUS? R000145 A-LMS Manual 10 v1.0 9/15

6.3 Control by Server via LAN Here is an example of the setup procedure for controlling the A-LMS with a D-cinema server (based on the GDC server, others should be similar): 1. Add the A-LMS as a 'Network Socket' 2. Enter the IP address as previously configured 3. Enter the default port of 9100 4. Transport control is TCP 5. Linefeed type is CR, LF. The 'None' option will not work. 6. Define the control cues. a. Enter Lights-Intermission' for the name and 'SCENE1' for the Value. b. Enter Lights-Previews for the name and SCENE2' for the Value. c. Enter Lights-Feature for the name and 'SCENE3 for the Value. d. Enter Lights-Credits for the name and SCENE4 for the Value. e. Enter whatever name you want to use for Scene 5 and 6 (if needed) 7. Enter the control cues in a playlist. 8. After these steps, Save. Now the A-LMS device will be available to work with the usual automation macros defined for playlists. Note: cleaning or emergency lighting modes will normally be selected by a hardware input rather than by the playlist in the server. R000145 A-LMS Manual 11 v1.0 9/15

Appendix Parts List, Schematics, and Warranty A000230-001 A-LMS 2 channel A000230-002 A-LMS 4 channel MODELS AND PART NUMBERS REPLACEMENT PARTS LIST R000145 A-LMS Manual 12 v1.0 9/15

Standard Product Warranty WARRANTY, DISCLAIMERS AND LIMITATION OF LIABILITY Unless otherwise noted, all Moving Image Technologies products are covered by the warranty set forth in the following paragraphs. The warranty is extended only to the purchaser of the Products directly from Moving Image Technologies, or an authorized dealer of Moving Image Technologies, as new merchandise. For a period of twelve (12) months from the date of original delivery to Buyer, the Products are warranted to be free from functional defects in materials and workmanship, provided they are operated under condition of normal use, and that repairs and replacements are made in accordance herewith. Moving Image Technologies does not warrant consumable components. The foregoing warranty shall not apply to Products that have been disassembled, altered or repaired other than by Moving Image Technologies (or by a Moving Image Technologies certified technician) or if the Product has been subject to abuse, misuse, negligence or accident. Moving Image Technologies sole and exclusive warranty obligation and Buyer's sole and exclusive warranty consists of Moving Image Technologies, at its option, repairing or replacing free of charge Products: (a) which contain a defect covered by the above warranty; (b) which are reported in writing to Moving Image Technologies not later than seven (7) days after the expiration of the twelve month warranty period; (c) which are returned to Moving Image Technologies promptly after discovery of the defects; and (d) which are found to be defective by Moving Image Technologies upon examination. Buyer shall pay all transportation charges. Moving Image Technologies shall not be otherwise liable for any damages, including, without limitation, loss of profits or overhead, reimbursement, personal injury or property damage. The aforesaid warranty obligation of Moving Image Technologies constitutes its sole liability, and under no circumstances, shall the maximum liability of Moving Image Technologies under any legal theory (e.g. Contract, warranty, negligence, promissory, estoppels, strict liability, misrepresentation, tort) and for any reason whatsoever (e.g. Defect, delay or otherwise) exceed the purchase price of the defective part, regardless whether the claim is asserted by buyer or any other person or entity. The liabilities of Moving Image Technologies, as above set forth, shall not be extended because of advice given by it in connection with the design, installation or use of the products or parts thereof. There are no express or implied warranties which extend beyond the warranties set forth above. Moving Image Technologies makes no warranty of merchantability or fitness for a particular purpose with respect to the products or any parts thereof. This warranty is subject to change at any time without notice. R000145 A-LMS Manual 13 v1.0 9/15

CONTACTING MiT To order parts or request information from MiT, use the address, telephone number, or fax number given on the inside front page of this document. When contacting MiT be prepared to provide: Model and serial number. Part name and part number, as shown in this manual. Original Purchase order number. The purchase order number is essential for replacement parts requested under warranty. MiT issues credit for defective parts received. Please request a Return Authorization number from MiT for any defective parts. R000145 A-LMS Manual 14 v1.0 9/15