Datalogging Manometer

Similar documents
Datalogging Manometers 2PSI, 5PSI, 15PSI , ,

Datalogging ph Meter

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

TMA40-A. Airflow Anemometer. English. 99 Washington Street Melrose, MA Phone Toll Free

Vacuum Meter Instruction Manual

TMA40. Airflow Anemometer. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Torque Meter. Instruction Manual

Datalogging Conductivity/ TDS Meter. Instruction Manual

4-Channel Datalogging Thermometer

RH/Temperature SD Card Datalogger. Instruction Manual

Torque Meter. Instruction Manual

Wide Range Pressure Meter Instruction Manual

Datalogging Hot Wire CFM Anemometer

Anemometer SD Card Datalogger. Instruction Manual

Visible Light SD Card Datalogger

4-Channel Thermometer

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

Mini Environmental Quality Meter

Dissolved Oxygen Meter

Light Meter with Bar Graph

Mini Environmental Quality Meter

AquaShock ph Meter K

Advanced Datalogging Thermometer. Instruction Manual

Psychrometer/Anemometer. Instruction Manual

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

Anemometer/Thermometer

4 Channel Datalogging Thermometer. Instruction Manual

Datalogging IAQ Meter Instruction Manual

Type K/J Thermometers

Mini Environmental Quality Meter

POCKET DIGITAL REFRACTOMETERS ~

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Sound Level Pen Instruction Manual

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

Light Meter (Foot Candles)

WBGT SD Card Datalogger. Instruction Manual

Datalogging RH / Temperature Pen Instruction Manual

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL

PH SD Card Datalogger. Instruction Manual

Mini Environmental Quality Meter

DATALOGGER With DATA LAB GRAPHICAL SOFTWARE INSTRUCTION MANUAL SPER SCIENTIFIC

Bluetooth IR Pen. Instruction Manual

WBGT SD Card Datalogger. Instruction Manual

DIGITAL REFRACTOMETERS , , , INSTRUCTION MANUAL SPER SCIENTIFIC LTD.

OPERATION MANUAL MULTI-FUNCTION DATALOGGER WITH PRINTER MULTI-FUNCTION DATALOGGER WITHOUT PRINTER

Temperature Datalogger

Dissolved Oxygen Meter Kit DOK. Instruction Manual

I/R Thermometer Gun 8:1

DIGITAL SOUND LEVEL METER. Instruction Manual

TestLink Software for Software Instruction Manual

Digital Manometer. for product register and warranty Customer Service:

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

User's Guide. Heavy Duty Differential Pressure Manometer. Model

Advanced Datalogging Sound Meter Instruction Manual

Oxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

Thermal Imaging Camera 220 x Instruction Manual

Heavy Duty Differential Pressure Manometer. Model User's Guide

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

350 SMART MANOMETER OPERATING INSTRUCTIONS

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com

DO Meter Kit. Instruction Manual

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

Manual Differential pressure meter PCE-910 / PCE-917

Heavy Duty Datalogger Module

PM2.5 and PM10 Monitors , & Instruction Manual

User s Manual. BCP-8000 Data Collector. Ver

Professional Benchtop Conductivity meter BC3020

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

Precision hand-held pressure indicator Model CPH6400

AUTOMATION. Operator s Manual PG-7. Full Access. Doc Part Rev B, 07/18. Automation Products Group, Inc.

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

Large Display Salinity & Conductivity Pens &

Heavy Duty Datalogger Module

Portable pressure calibrator Model CPH7600

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge

Portable low-pressure controller Model CPC2000

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

INSTRUCTION MANUAL. Models: H100 Light Meter

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

AUTOMATION. Operator s Manual PG-5. Full Access. DOC Rev. A1 3/10

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Indoor Air Quality Meter/Datalogger

CONTENT. Check up. Brief. 1.Before use. 2.Operation. 3.Others

PM930SD USER S MANUAL

CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Digital Test Gauge Operating Instructions

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

OPTERATING MANUAL. TT Series Micromanometer 550 High Resolution

DTW 400/DTW Digital Torque Tester/Screwdriver User s Guide

AWA6223S Sound Level Calibrator. Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD

VACUUM METER Model : VC-9200

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

Transcription:

Datalogging Manometer 840086, 840098 and 840099 Instruction Manual

TABLE OF CONTENTS Introduction.. 3 Front Panel Descriptions.. 4 Set-up.. 5-6 Calibration.. 7 Measurement Procedures.. 8-14 Error Codes.. 14 Auto Power Off.. 14 Battery Replacement.. 15 Specifications.. 15-16 Software Configuration.. 17-19 Accessories.. 19 FIRST TIME USE Before using the Manometer the first time ensure that the user-defined settings have been configured (see page 5), and that the meter has been calibrated (see page 7)

INTRODUCTION This Manometer is ideal for measuring gauge pressure and low differential pressure in clean rooms, test and balance, medical equipment, HVAC, pneumatic systems and computer peripherals. Features a user-friendly interface with a large backlight display, automatic data logging, measurement of single and multiple points and a tripod mount. The RS232 port, cable and software enable communication with a computer. Powered by 4-AAA batteries (included), or an optional 9V adaptor. Gauge Pressure: A measure of pressure in PSI that refers to ambient pressure. Differential Pressure: Measurement of the difference between two pressures. 3

FRONT PANEL DESCRIPTION Connectors Welcome Display View previous/ next record MEAS MEM LOG SET F1 F2 F3 F4 1 SYM. 2 ABC DEF 3 4 GHI 5 JKL MN0 6 7 PQRS 8 TUV WXYZ 9 0 ON/OFF On Screen prompts correspond to the F1-F4 buttons. Keypad, press: 1 for 1*:$+-=, 2 for 2abcABC 3 for 3defDEF 4 for 4ghiGHI 5 for 5jklJKL 6 for 6mnoMNO 7 for 7pqrsPQRS 8 for 8tuvTUV 9 for 9wxyzWXYZ 0 for 0 and space Backlight On/Off Not Applicable DC 9V Adaptor Port RS232 Port 4

SET-UP PROCEDURE Turn the meter on using the ON/OFF button. You will see the Welcome menu shown below. Welcome MEAS MEM LOG SET LCD Cont. (1-5): 3 Prn Cont. (1-9): 5 Auto Off: 20mins Enable EXIT EDIT NEXT Set Clock: MM-DD-YY HH:MM:SS 06-30-05 18 : 29 : 20 Set ID: Disable ID: User Name EXIT EDIT NEXT 1. Press F4 (SET) to enter the setup mode. 2. Use the or buttons to move the on-screen cursor, F2 (EDIT), and the Keypad to input changes. 3. If changes are made, press the F4 (Enter) button to save the new settings or F1 (ABORT) to cancel the change. 4. Press F4 (NEXT) to access the next page. Select Item P psi 5. Press F1 (EXIT) to return to the Welcome menu. EXIT EDIT BACK 5

SET-UP PROCEDURE Welcome MEAS MEM LOG SET LCD Cont. (1-5): 3 Prn Cont. (1-9): 5 Auto Off: 20mins Enable EXIT EDIT NEXT Set Clock: MM-DD-YY HH:MM:SS 06-30-05 18 : 29 : 20 Set ID: Disable ID: User Name EXIT EDIT NEXT Select Item P psi EXIT EDIT BACK 1.LCD Cont. (1-5): Display contrast, 5 = least contrast. 2.Auto Off: 1~20 minutes, Enable/ Disable. 3.Set Clock: Select the date mode MM-DD-YY, DD-MM-YY or YY-MM-DD and set local time. 4.Set ID: Enable/Disable datalogging. 5.ID: Alpha/numeric user name. 6.Select Item: Press F2 (EDIT) to select X = not selected, = selected. 7.Press the F2 (EDIT), or buttons to cycle through the 11 units of measure shown below: PSI inh2 kpa fth2 inhg cmh2 mbar bar mmhg ozin kgcm 6

CALIBRATION Calibration 1. Full (HI-LOW) calibration requires a standard manometer calibrator and should be performed by a professional calibration laboratory. Contact Sper Scientific. 2. To perform a ZERO calibration, disconnect all tubes and do not apply pressure to the connectors. 3. Press F1 (MEAS) followed by F3 (Cali) - Calibration is displayed. 3. Press F4 (ZER0) and Cali: 0.000 PSI will be displayed. 4. Press F4 (ENTER) again - after approximately 3 seconds the meter will display OK to indicate that the calibration was successful. 5. If NG (No Good) is displayed, perform the calibration again. If the meter fails to calibrate after three (3) attempts, it should be returned to Sper Scientific. 7

MEASUREMENT PROCEDURES Measurement Modes The unit offers three (3) measurement modes: 1. F1 (MEAS) Single Measurement 2. F2 (MEM) Multiple Measurement 3. F3 (LOG) Auto Logging Single Measurement Welcome MEAS MEM LOG SET P: 0.1 psi EXIT REC Cali Pressure Max: 1.2psi Min: -1.2psi Avg: 0.4psi Curr: 0.1psi EXIT 1. Ensure the tubing is connected and not leaking or damaged. 2. Press F1 (MEAS) to take a single pressure measurement. 3. Once a pressure is detected the reading is displayed. 4. If desired, press F2 (REC) to display the real-time Max., Min. and Avg. pressure and last pressure readings. 5. Press F1 (EXIT) to return to the Welcome menu. 8

MEASUREMENT PROCEDURES Multiple Measurement Manually record up to 99 data points with time & date and your filename. Welcome MEAS MEM LOG 0. 1 02 P. P. P. EXIT MEAS EDIT 0. 1 02 P. P. P. EXIT CLR BACK 0.1 P. 0.100psi ABORT SAVE 0. 06:30:23:56:49 1 P. 100psi 02 P. P. EXIT MEAS EDIT NEXT 0. 06:30:23:56:49 1 P. 100psi 02 P. P. EXIT CLR BACK 1. Press F2 (MEM) to enter Multiple Measurement mode. 2. Press F2 (MEAS) to take a measurement. 3. Once a pressure is detected the reading is displayed. 4. Press F4 (SAVE) to save the reading or press F1 (ABORT) to exit the current reading. 9

MEASUREMENT PROCEDURES 5. By default, the first reading will be stored in memory location 01: using the date & time as the filename. The pressure reading is displayed next to the P: (for example: 0.025 psi). 6. If desired, press F3 (EDIT) to edit the filename. Then, use the Keypad to edit the filename. Cycle through the characters by depressing the key until the desired character is highlighted. Once the filename has been defined, press F4 (ENTER). 7. To take another reading, press the button to advance to the next memory location and continue with the next reading. 8. Press F1 (EXIT) to return to the Welcome menu. 10

MEASUREMENT PROCEDURES Clear Single Memory Record 1. Press F2 (MEM) to enter Multiple Measurement mode. 2. Use the or buttons to move to the desired memory location. 3. Press F4 (NEXT) then press F2 (CLR). Once F2 is pressed the Clear? message is displayed. Press F2 (YES) again to clear the highlighted memory location or F3 (NO) to cancel the clear function. 4. Press F1 (EXIT) to return to the Welcome menu. Clear All Memory Records 1. Press F2 (MEM) to enter Multiple Measurement mode. 2. Press F4 (NEXT) then press F2 (CLR) for two (2) seconds. After two (2) seconds the Clear All? message is displayed. Press F2 (YES) again to clear all 99 memory locations or F3 (NO) to cancel the clear function. 3. Press F1 (EXIT) to return to the Welcome menu. 11

Run Auto Logger MEASUREMENT PROCEDURES Welcome MEAS MEM LOG SET 0023: P: 0024: P: 0025: P: 06-30 02:28:55 0.1 psi EXIT START SET NEXT 1. Press F3 (LOG) to enter log mode. 2. Press F3 (SET) to modify the user-defined parameters. 0023: 06-30. 02:28:55 P: 0.1 psi 0024: P: 0025: P: P-PG N-PG BACK Begin: 30-06-06 Start: 02:28:06 End: 02-07-05 Suspend: 03:28:55 Rate: 60Sec(s) Expect: 12000Point(s) Remain: 11977Point(s) EXIT EDIT VIEW NEXT Begin: 30-06-06 Start: 02:28:06 End: 02-07-05 Suspend: 03:28:55 Rate: 60Sec(s) Expect: 12000Point(s) Remain: 11977Point(s) START CLR BACK 3. Use the and buttons to select an auto log parameter and press F2 (EDIT) to edit. Begin date* Start time End date* Rate (1 to 7200 seconds) Suspend time Logging... STOP MEAS VIEW 0023: 06-30 02:28:55 P: 0.100 psi 0024: P: 0025: P: STOP MEAS ESC For 24 hour logging, set the Start time to 00:00:00 and the Suspend time to 23:59:59. Expect is the total number of memory points (12,000). Remain shows the number of available memory points (12,000 minus the number already recorded). ESC P: 0.100 psi * Ensure date formats are consistent 12

MEASUREMENT PROCEDURES 4. Press F4 (ENTER) after modifying a parameter. 5. Once the parameters have been set press F4 (NEXT) and F1 (START) to start the auto logger. The word Logging will be displayed. The meter will automatically start and stop logging according to your chosen parameters. Once the required number of data points is reached, logging stops and the records are held in the data logger. 6. During the auto logging press F2 (MEAS) to take a realtime reading or F4 (VIEW) to view memory record. 7. To stop auto logging press F1 (STOP). 8. Use the and buttons to scroll through the memory records. 9. Press F4 (NEXT) to access the previous and next page buttons. Press F1 (P-PG) or F2 (N-PG) to review previous or next 100 data points. 10. Press F4 (BACK) to access the auto log main menu and press F2 (Start) to continue auto logging or F1 (EXIT). 13

MEASUREMENT PROCEDURES Clear Auto Log Data 1. Press F3 (LOG) to enter log mode. 2. Press F3 (SET) to enter auto log parameter set-up. 3. Press F4 (NEXT) to access the clear option. 4. Press F2 (CLR) for two (2) seconds and the Clear All? message is displayed. 5. Press F2 (YES) to clear all auto log data, or F3 (NO) to cancel clear function. 6. After clearing all auto log data, press F4 (BACK) to return to auto log parameter set-up. 7. Press F1 (EXIT) to return to the Welcome display. ERROR CODES E2: The value is under-range E3: The value is over-range E4: Error reading sample AUTO POWER OFF To prolong battery life, the meter will turn off automatically if no buttons are pressed for your preset (1~20 minutes). To edit or disable this feature, press F4 (SET) to access the setup mode, then use the F2 (EDIT), or buttons and Keypad to make changes. 14

BATTERY REPLACEMENT When the low battery icon is displayed, open the battery cover, install 4-AAA Alkaline batteries and replace the cover. Remove the batteries during prolonged periods of nonuse. 840086 SPECIFICATIONS Unit of Measure Range Resolution PSI ±5 0.001 inh 2 O ±138 0.1 kpa ±34.5 0.01 fth 2 O ±11.5 0.01 inhg ±10.2 0.01 cmh 2 O ±352 0.1 mbar ±345 0.1 Bar ±0.345 0.001 mmhg ±259 0.1 oz / inch2 ±80 0.01 Kg / cm2 ±0.35 0.001 Max Pressure 20 PSI Accuracy ± 0.3% fs @ 25 ºC Repeatability ± 0.2% typ, max ± 0.5% fs Combined linearity & hysteresis ± 0.29% typ, max ± 1.0% fs Manual Memory 99 Auto Log Memory 1200 Battery 4-AAA Alkaline Weight 9 oz (255g) Dimensions 208x70x53 mm 15

840098 SPECIFICATIONS Unit of Measure Range Resolution PSI ±2 0.001 inh 2 O ±55.36 0.01 kpa ±13.79 0.01 fth 2 O ±4.614 0.01 inhg ±4.072 0.01 cmh 2 O ±140.6 0.1 mbar ±137.9 0.1 Bar ±0.138 0.001 mmhg ±103.4 0.1 oz / inch2 ±32.48 0.01 Kg / cm2 ±0.141 0.001 Max Pressure 20 PSI 840099 SPECIFICATIONS Unit of Measure Range Resolution PSI ±15 0.01 inh 2 O ±415.2 0.1 kpa ±103.4 0.1 fth 2 O ±34.6 0.01 inhg ±30.54 0.01 cmh 2 O ±1054 1 mbar ±1034 1 Bar ±1.034 0.001 mmhg ±775.7 0.1 oz / inch2 ±240 0.1 Kg / cm2 ±1.055 0.001 Max Pressure 30 PSI 16

SOFTWARE CONFIGURATION Use the included USB 2.0-P cable and software to download saved data to a PC for further analysis, or to upload pre-edited filenames to save set-up time. PC requirements: Win98 or above. Main Menu Options (see Figure 1) File Mode Port Command About Main Menu Options Figure 1. Mode Menu Option 1. There are two (2) data modes: Memory and Logger. 2. Select the data mode from Mode on the main menu or the drop-down menu. (see Figure 2) 3. In Logger mode, select GoTo to choose the logged data range you wish to display. 17

SOFTWARE CONFIGURATION Figure 2. Com Port 1. Select the Com port and ensure that the meter is communicating with the PC. 2. The selected Com port is displayed in the bottom-left hand corner of the software screen. Com1 3. When connected, PC Mode and the Com port number (1-8) are displayed on the meter. Command Options There are four (4) command options supported by the software. Choose the correct mode before uploading or downloading data. (see Figure 3) 1. Download Memory Data 2. Download Logger Data 3. Download All Data 4. Upload Memory Description 18

SOFTWARE CONFIGURATION Figure 3. Print Options Select the data to be printed from the following three (3) choices: (see Figure 4) 1. All Data ( Memory and Logger Data printed in sequential order). 2. Memory Data 3. Logger Data Figure 4. ACCESSORIES 840089 Rubber Holster 840090 Water Resistant Pouch 840096 AC Adapter 19

Sper Scientific warrants this product against defects in materials and workmanship for a period of ONE (1) year from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD 7720 E Redfield Rd, Suite 7 Scottsdale, AZ 85260 WWW.SPERSCIENTIFIC.COM INFO@SPERSCIENTIFIC.COM The defective unit must be accompanied by a description of the problem and your return address. Register your product online or return your warranty card within 10 days of purchase. Revised 5/2/2012