Product Data Sheet. SC Thead-Lock Connector Assembly Instructions. Page 1 of 5 QUALITY FIBER COMPONENTS, EQUIPMENT, & SUPPLIES

Similar documents
Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors

FiberExpress Brilliance Connectors

TABLE OF CONTENTS 1. GENERAL PRECAUTIONS...3

Optical Fiber Assemblies

3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS

Emerging Fiber Termination Solution

Panduit Certified Installer. Fiber Certification Review

Pre-polished Connector Insertion Loss and Termination Yield. Achieving High Termination Yields And Low Insertion Loss Values

OptiCam 2. Terminating OptiCam Connectors Using OptiCam 2 Termination Tool

Encore XT Manual Gun Upgrade Kit

Copyright Black Box Corporation. All rights reserved.

3M Fibrlok Optical Splice System

Halo-5 Microdrive. Users Manual. Microdrive used for manually driving tetrodes for electrophysiology recordings

Elecraft K3 KPA3 Power Connector Replacement Revision B, June 30, 2017 Copyright 2017, Elecraft, Inc. All Rights Reserved

Instruction Manual R&M Connectors. R&M Fiber Optic Components. System security for future requirements. Version 2.4

UniCam High-Performance Connectors, Multimode and Single-Mode

Replacing/Upgrading Mac Pro Processors (Early 2008)

Wall Mounted Building Entrance Enclosure Instructions

OptiSheath Advantage Sealed 4-, 6-, 8- and 12-Port Multiport Terminals

Economizer Regulator Filter Upgrade

XEROX PHASER 6250 TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS

White Paper. FASTConnect or FUSEConnect Which Should You Choose? ABSTRACT INTRODUCTION. Tom Jeffers, Associate Product Manager, AFL

OFS Assembly Instructions UNIV Instruction Sheet for Pre-radiused LC Fiber Optic Comcode: D05AK0029 Behind-The-Wall (BTW) Connectors

Fiber Termination Where we ve been and where we re going. Lylette Macdonald, RCDD Legrand Ortronics

SC Field Installable Connectors

MVPplus Quick Reference Guide

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

Application Specification OPTIMATE* Fiber Optic Lightplane Connector 13 OCT 09 Rev B

Removing and Replacing Parts

Product Bulletin PB 308

Further Information can be found at

ASSET LGA1366 Top-side Probe

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

Mini Wall-mount Building Terminal (WBM)

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR SIMPLEX OPTICAL FIBER (MULTIMODE) NO-EPOXY, NO-POLISH CONNECTORS

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

Audi Climate Control LCD Rebuild Kit

User Manual. Trinocular Stereo Microscope

Removal and Installation 8

Rack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates

Field-Installable Fiber Optic Connector Tool Kits

Zebra XiII-Series Printer Quick Reference Guide

When you are ready to build your computer you will have the following materials to work with.

Replacing the SATA PCI Controller Card

3 Maintenance. Chapter contents

COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET CONNECTORS, FIBER OPTIC, SINGLE FIBER, SMALL FORM FACTOR, LC TYPE

with Fiber Management Bar

RIFOCS Corp. Component Services Division

3 Angled Connector Housing (MC) Installation

FUSION SPLICERS Splicing Made Easy and Affordable

01-161, -162, -163, AND -164 GAUGING SETS USER S GUIDE

1530R & 1540 All-in-One Pro Data/Phone Tools

SX4M SX5M TXPSX4 TXPSX5

FP 00C GS0 FP 00C HS0 FP 00C TS0 Crimpless Connector for Plastic Optical Fiber Data Sheet

MICROMANIPULATOR TABLE OF CONTENTS 1.0 INTRODUCTION SAFETY...3

User Manual. Trinocular Stereo Microscope

UniCam Connector Installation Tool Kits

ipad Mini Wi-Fi Front Facing Camera Replacement

HD Flex Zero RU Cassette Holder and Bracket

Product information 19" 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330

Central Processing Unit (CPU) Replacement

Welch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement

March 2018 OM1 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OM4 MULTIMODE DUPLEX FIBRE OPTIC CABLE 500M OS2 SINGLEMODE DUPLEX FIBRE OPTIC CABLE 500M

TOOLS TOOLS. Chapter Summary All the tooling required to install optical fiber and twisted pair connectors

Raptor Series Adapters

Case for iphone 6/6S

imac Intel 21.5" EMC 2389 Stand Replacement

VIS Video Inspection Scope

Singlemode SC Connector Kits Polymer Crimp Body. Housing Boot. 3.0 mm Jacketed. Simplex Blue Blue. Duplex Blue Blue

M204SMB Surface Mount Box Instructions

3D SYSTEMS University CubeX 3D Printer

UniCam Connector Installation Tool Kits

Ruger SR22. Operator s Manual RUGER SR22 SR9C SR40C 9E LMS-RMSR

Equipment (Tools) Needed

Removal and Installation8

Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749

GVIS Video Inspection Scope

Spec Sheet. OmniReach FTTX Solutions DLX Fiber Optic Connector

GbX Backplane and Daughtercard Tooling. *GbX is a Trademark of Teradyne Inc.

apple Service Source imac (USB 2.0) Updated 11 September Apple Computer, Inc. All rights reserved.

Written By: Kaitlyn Fisher

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

Dell Latitude V710/V740 Service Manual

Adapter guide for C167/ST10, emulators

Note: Clean Work area of all or any debris after Repair.

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

Pretium Rack-mountable 1U Housing Hardware

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

Source Four PARNel. Assembly Guide

Module Connectors and Cable Specifications

- Optical FAQ Highway 108 Sierra Village, CA Telephone: (800) Fax: (209) Optical Connectors:

Xi4 Quick Reference Guide

FIBRE ENCLOSURES AND SPLICING ACCESSORIES

NewScope-T0 Operation Manual

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

Dell Inspiron XPS and Inspiron 9100 Service Manual

VFS 2 Video Fiber Scope User s Guide. Test & Inspection

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

Transcription:

Page 1 of 5 SC Thead-Lock Connector Assembly Instructions

Page 2 of 5 A. 2.0mm, 2.5mm & 3.0mm JACKETED CABLE 1. Place jacketed fiber protective boot on cable and slide back. (Figure 1) NOTE: To help avoid tool, buffer and fiber contamination, clean 4-6 inches of jacket first with a 99% alcohol wipe, then with a lint-free wipe. 2. Remove jacket 1-1/2". Clean with a 99% alcohol wipe followed by a lint-free wipe to remove any con-taminants. Gently snap the shorter length 900µm Build-up Sleeve (BUS) onto fiber, butting it up against the jacket. Strip the 900µm buffer back 1 to within 1/4 of the BUS. Strip about 1/4 at a time. (Figure 2) 3. Trim aramid strands back even with the end of the tight buffer that surrounds the fiber (approximately 1/2 ). Clean fiber with 99% isopropyl alcohol and a lint-free wipe to remove coating. (Figure 3) 4. Distribute aramid strands evenly over the outer surface of the 900µm BUS. Fold the retention sleeve over the BUS and the distributed aramid strands. Align end of the BUS with threaded end of the reten-tion sleeve. Leave 1/8-1/4 of buffered fiber exposed and complete assembly and polishing process as described in section D. (Figure 4)

Page 3 of 5 B. 900 µm BUFFERED FIBER 1. Place bare fiber protective boot on cable and slide back. (Figure 5) NOTE: To help avoid tool, buffer and fiber contamination, clean 4-6 inches of jacket first with a 99% alcohol wipe, then with a lint-free wipe. 2. With indelible marker (Leviton PN# 49886-SMP), mark the buffer 1.5 inches from the edge of the buffer. To measure, use the ruler in this instruction sheet, or the one marked on your buffer remover. Gently snap the longer (5/8 long) 900 µm BUS onto the buffered fiber, butting it up against the line. (Figure 6) 3. Grasping the BUS firmly, strip the buffered fiber back 1", using 1/4 increments. Clean with 99% iso-propyl alcohol and a lint-free wipe to remove any debris. (Figure 7) 4. With thumb and forefinger at the base of the BUS, slide BUS slightly forward to within 1/8"-1/4" of buffered fiber end. (Figure 8) NOTE: Do not squeeze the BUS, as excessive external pressure may cause difficulty in moving the BUS. 5. Fold threaded retention sleeve over BUS even with the end and complete the assembly and polish-ing process as described in Section D. (Figure 9)

Page 4 of 5 C. 250 µm LOOSE TUBE GEL FILLED FIBER 1. Remove all gel from fiber with industrial strength solvent pad such as a D-Gel pad. Follow with a lint-free wipe, an alcohol wipe, and another lint-free wipe.(figure 10) 2. Install 900 µm fan-out kit (furcation tubing) per manufacturer s instructions and place bare fiber pro-tective boot on assembly and slide back (Figure 11). Clean 3-4 inches of buffer and fan-out kit with 99% isopropyl alcohol wipe. 3. Gently rotate BUS down on furcation tubing, then slide bare fiber into 250 µm BUS and move BUS back until it securely fits over furcation tube. (Figure 12) 4. Grasp the BUS firmly, and strip fiber coating back about 1 and leave 1/8-1/4 of 250 µm coating exposed (Figure 13). Clean exposed fiber with 99% isopropyl alcohol wipes. 5. Fold retention sleeve over BUS so it is even with the end (Figure 14). Complete the assembly and pol-ishing process as described on Page 5, Section D.

Page 5 of 5 D. ASSEMBLY AND POLISHING PROCESS 1. Insert connector into tightening tool and then while firmly holding the threaded sleeve together, insert fiber into connector housing (Figure 15). Rotate connector housing down over threaded sleeve. To rotate, use the tightening tool and grip the sleeve head with pliers. Rotate connector housing, not threaded sleeve (Figure 16). Trim away any exposed aramid strands. 2. Tighten down connector housing until flush with threaded sleeve head. 3. Cleave fiber by use of the Versa-Cleave or scribing tool. (Figure 17) 4. 12 µm AIR POLISH FOR SINGLEMODE AND MULTIMODE FIBER - Begin by Air Polishing the con-nector with 12 µm polishing film. Hold film at the edge with thumb and forefinger. Gently touch con-nector to film and rotate using 18-20 one-inch circles to remove fiber stub. 3 µm POLISH FOR SINGLEMODE AND MULTIMODE FIBER - Wipe the bottom surface of the polishing puck and the surface of the connector with a 99% alcohol wipe. Place 3µm film on the polishing pad, dull side up, and set polishing puck on the film. Gently insert the connector into the puck, and trace 15-20 Figure 8 s on the film, using very light pressure and proceeding to firmer pressure as you progress. Repeat the same procedure with the.3µm film. 5. Slide protective boot up to coupling nut. 6. Inspect the fiber using the 200x inspection scope, to be sure the fiber is not scratched, cracked or broken. Remove any debris using a lint-free wipe. (Figure 18)