testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x

Similar documents
The industrial humidity transmitter

The industrial humidity transmitter

testo Probe series testo 661x The industrial humidity transmitter Committing to the future

Humidity transmitter for critical climate applications

Differential Pressure Monitoring in Cleanroom Technology

testo 6681 Humidity transmitters testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 1

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

Vaisala HUMICAP Structural Humidity Measurement Kit SHM40. Full SHM40 product presentation and introduction to the borehole method

testo 6681 Profibus Humidity transmitter with Profibus module testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

EE32/33 Series. Humidity / Temperature Transmitter for High Humidity and Chemical Applications. Typical Applications. Features

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

Environmental Conditions C - remote sensing probe up to 120 C (248 F)

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

DMT345 and DMT346 Dewpoint Transmitters

PTU300 Combined Pressure, Humidity and Temperature Transmitter

CAEL-DP Series Dew Point Transmitter for Industrial Control

Measurement data monitoring system

Measurement data monitoring system

Measurement data monitoring system

testo 6651 Humidity transmitters testo 6600 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 1

Measurement data monitoring system

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

testo 6651 Humidity transmitters testo 6600 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual

Precision digital measuring device PHYSICS 51

Supplied with. Calibration certificate. HD 200 Hygrometer

WiFi data logger system

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

Measurement data monitoring system

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

PHYSICS Digital Measuring Devices

Next Generation! Committing to the future. With the professional Testo data loggers, a new age begins for you. Logger series testo 174

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Multi Units Humidity/Temperature Transmitter. HygroViewer Model JW300 User Manual

InBin-P Pressure switches from 5 Pa Pa

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

HygroClip DIGITAL Humidity and temperature probe

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

testo 6740 Instruction manual

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

Humidity goes Digital

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

VAC analysis measuring instrument

TEMPERATURE CO 2 CALIBRATION

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

Instruction Manual. T3110 T3110L T3110Ex

MMT330 Series Moisture and Temperature Transmitters for Oil

USER'S GUIDE. Vaisala HUMICAP Indicator HMI41 and Probes HMP41/45/46 M210316EN-A

WiFi data logger system

EE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.

USER S GUIDE. EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL ASSEMBLY SCOPE OF SUPPLY CAUTION

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

WiFi data logger system

Humidity goes Digital

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Sensor for car parks and tunnels

Operation manual EE310. Humidity/Temperature Transmitter. BA_EE310_e // V2.1 // Technical data subject to change //

Data logger / EASYBus

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

All measurement data. Always available. On any device. The WiFi data logger system testo Saveris 2. Analysis & Reports. Graphical presentation

TEMPERATURE AND HUMIDITY TRANSDUCER P18(D) TYPE

Advantages high measuring dynamics Nv (up to 1 : 1000) measuring range from 0.2 m/s. low measuring uncertainty, even at lowest flow velocities

Miles Ahead of the Competition!

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement

HLX75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C

EE210. Humidity and Temperature Transmitter for Demanding Climate Control Applications. Features. Applications

HMT330 Series Humidity and Temperature Transmitters for demanding humidity measurement

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

InCos-P Pressure sensor 20 Pa Pa

ProcessCalibrator Model CPH6000

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

EE35. Industrial Transmitter for Dew Point Measurement. Autocalibration. Installation. Alarm Output. Integrated power supply. Typical Applications

x testo 400 The reference measuring instrument for A/C and ventilation systems Additional information at

We measure it. Automated and uninterrupted measurement data recording. Flexible system set-up with wireless or Ethernet probes in many probe versions

Measurement data monitoring system testo Saveris.

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

Precision humidity/temperature control/sensing

Measurement data monitoring system testo Saveris.

testo 176 Data loggers

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

CDD4 Duct Carbon Dioxide Transmitter

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual

HMT330 Series Humidity and Temperature Transmitters

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

with serial RS485/RS232 output

Differential pressure measuring instrument

with serial RS485/RS232 output

Hand-Held Thermometer Model CTH 6200

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Dräger Polytron 8200 Stationary gas detector (CatEx)

Measure, document, issue alarms. Automated with testo Saveris. Committing to the future

Transcription:

+ Probe series testo 661x SPECIFICATIONS Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment Profibus, Ethernet, relay and analog outputs allow optimum integration into individual automation systems Self-monitoring and early warning guarantee high system availability Calculation and presentation of all relelvant humidity parameters P2A software for parameterization, adjustment and analysis saves time and costs in commissioning and maintenance Display with multi-language display Robust, easy-to-clean metal housing Probe series testo 661x SPECIFICATIONS + Probe series testo 661x Industrial humidity measurement demands absolute professionalism. Not only in running the system, but also in the measuring technology used. The industrial humidity transmitter, combined with the probe series testo 661x fulfils these high demands. The has a number of additional features, above and beyond the properties and benefits of a conventional transmitter, which will delight practitioners. Areas of application: Stationary humidity measurement in production/process technology: Drying processes: - Drying tobacco, - Ceramics production - Drying roof tiles Spray-painting booths Food: - Maturing cheese - Ripening fruit - Drying pasta Bio research Mushroom farming Special areas high humidity Sterilization processes in H 2 -atmospheres Stationary measurement of indoor ambient conditions: Monitoring comfort levels Museums Storage of hygroscopic substances Storage of electronic components 0981 8244/msp/A/08.2011 Page 1/5

+ Probe series testo 661x Technical data Measurement parameters Humidity Selectable units Trace humidity Selectable units Dependent on probe, available are: relative humidity %RH; normed atm. dewpoint in CtdA ( Ftd); dewpoint in Ctd ( Ftd); absolute humidity in g/m³ (gr/ft³); degree of humidity in g/kg (gr/lb); enthalpy in kj/kg (BTU/lb); psychrometer temperature in Ctw ( Ftw); water vapour partial pressure in hpa/h20; water content in ppmv; mixture dewpoint H 2 in Ctm/ Ftm; %RH acc. to WMO; temperature in C/ F 0 to 100 %RH Dewpoint in Ctd/ Ftd -60 to +30 Ctd / -76 to +86 Ftd (only with testo 6610) Temperature Selectable units Temperature in C/ F Dependent on probe (testo 661x) General technical data Design Material Dimensions Weight Display Display Resolution Operation Parameterization Installation Probe connection Miscellaneous Protection class EMC Metal 122 x 162 x 77 mm (without probe) 1.5 kg (without probe, without Profibus/Ethernet module) Optional: 2-line LCD with clear text line and relay status display 0.1 %RH / Ctd / Ftd / Ctw / Ftw or 0.01 C/ F 1g / kg / g/m³ / ppm 4 operating buttons for display / P2A software Digital probe connection IP65 2004/108/EG Inputs and outputs Analog outputs Quantity Output type 2 channels (analog signal type uniform for both channels, decided when ordering), additional 3rd channel (optional) 0/4 to 20 ma (2-wire/4-wire) 0 to 1/5/10 V (4-wire) Measurement rate 1/s Galvanic isolation Galvanic isolation of the output signals (2-wire and 4-wire), isolation of supply from outputs (4-wire) Operating conditions Operating temperature (with integrated relay) Without display With display -40 to +60 C Operating temperature -40 to +70 C / -40 to +158 F Storage temperature -40 to +80 C / -40 to +176 F Operating temperature 0 to +50 C / +32 to +122 F Storage temperature -40 to +80 C / -40 to +176 F Measurement medium Air, nitrogen; more on request: applicationsupport@testo.de Resolution Accuracy of the analog outputs Max. load 12 bit 0/4 to 20 ma ± 0.03 ma 0 to 1 V ±1.5 mv 0 to 5 V ±7.5 mv 0 to 10 V ±15 mv 2-wire: 12 VDC: max. 100 / 24 VDC: max. 500 / 30 VDC: max. 625 ; 4- wire: 500 Further outputs Ethernet Profibus-DP Optional: module can be fitted as intermediary layer Optional: module can be fitted as intermediary layer, cannot be combined with Ethernet module Relays Optional: 4 relays (free allocation to measurement channels or as collective alarm with operating menu/psa software), up to 250 VDC /3 A (NO/NC) Page 2/5 Other outputs Mini DIN for Testo P2A software and portable measuring instruments testo 400/650 Supply Voltage supply 2-wire: 24 VDC ±10 % 4-wire: 20 to 30 VAC/DC Current consumption max. 300 ma 0981 8244/msp/A/08.2011

+ Probe series testo 661x Technical data probe range testo 6610 testo 6611 testo 6612 testo 6613 testo 6614 testo 6615 testo 6617 Type Operating range Wall Cable Cable Heated cable Cable trace humidity (selfadjustment) Room climate probe wall mounting Process humidity Process humidity probe duct mounting probe flexible with cable Humidity probe for high humidity applications / when risk of condensation Humidity probe for trace humidity / dewpoint (with selfadjustment) Cable with cover electrode monitoring Humidity probe with self-monitoring for sensor-damaging media Measurement parameters Humidity Measurement uncertainty* (+25 C)** 0 to 100 %RH see trace humidity 0 to 100 %RH testo 6611/12/13: ±(1.0 + 0.007 * mv) %RH for 0 to 100 %RH / ±(1.4 + 0.007 * mv) %RH for 90 to 100 %RH; testo 6614: ±(1.0+ 0.007 * mv) %RH for 0 to 100 %RH; testo 6617: ±(1.2 + 0.007 * mv) %RH for 0 to 90 %RH / ±(1.6 + 0007 * mv) %RH for 90 to 100 %RH +0.02 %RH per Kelvin dependent on the process and electronics temperature (for a deviation of 25 C / 77 F) Selectable units %RH; C td / F td ; g/m 3 / gr/ft 3 ; g/kg / gr/lb; kj/kg; BTU/lb; Ctw/ Ftw; hpa; inch H 2 ; ppm vol %; %vol; Ctm (H 2 )/ Ftm (H 2 ) Reproduceablility better than ±0.2 %RH Sensor Testo capacitive Testo capacitive humidity sensor; soldered humidity sensor, plug-in Response time t90 max. 10 sec. Temperature Selectable units C/ F -20 to +70 C/ -4 to +158 F -30 to +150 C/ -22 to +248 F -40 to +180 C/-40 to +356 F -40 to +120 C/- -40 to +180 C/- 22 to +302 F 40 to +356 F Measurement uncertainty* (at +25 C / +77 F) ±0.15 C / 0.27 F (Pt1000 Class AA) Pt100 Class AA Pt1000 Class AA Trace humidity Trace humidity Measurement uncertainty General technical data Probes Probe shaft Cable Plug Probe dimensions (diameter) Probe dimensions (probe shaft length) Cable length Operating conditions Pressure tightness * Other accuracies apply for wall probe length 70 mm combined with a current output (P07): Operation: 2 channels at 12 ma, without display illumination, relay off, additional measurement error to above values at +25 C (+77 F), humidity ± 2.5 % RH **The determination of measurement uncertainty takes place according to GUM (Guide to the Expression of Uncertainty in Measurement): For the determination of measurement uncertainty, the accuracy of the measuring instrument (hysteresis, linearity, reproduceability), the uncertainty contribution of the test site as well as the uncertainty of the adjustment site (works calibration are taken into account. For this purpose, the value of k=2 of the extension factor, which is usual in measurement technology is used as a basis, which corresponds to a trust level of 95%. 70/200 mm 200/300/500/ 800 mm specially for duct versions 120/200/300/500/ 800 mm -60 to +30 C td Stainless steel FEP coated Plastic ABS 12 mm 1 bar positive pressure (probe tip) PN 10 (probe tip) PN 1 (probe tip) ±1 K at 0 C td ±2 K at -40 C td ±4 K at -50 C td 200/500 mm 1/2/5/10 m PN 16 (probe tip) 1 bar positive pressure (probe tip) 0981 8244/msp/A/08.2011 Page 3/5

+ Probe series testo 661x Technical drawings a b 122 77 162 Duct probe testo 6612 Cable probe testo 6613 Wall probe testo 6611 Cable probe testo 6614 Cable probe testo 6615/6617 Connection plan Connection plan 2-wire technology (4 to 20 ma) 18 24 VDC + - 0 V CH1 CH2 CH3 + - + - + - 2 or 3 channels 4 to 20 ma, max. load 100 to 750 (at 24 V) + - 24V CH1 CH2 CH3 + - + - + - + - L = Probe length L A = Probe length length protective cal A = 35 mm Connection plan 4-wire technology (0 to 20 ma / 4 to 20 ma / 0 to 1 V / 0 to 5 V / 0 to 10 V) 18 24 VDC 0 V 2 or 3 channels 0 to 20 ma / 4 to 20 ma, max. load 500 each 0 to 1 V / 0 to 5 V / 0 to 10 V 0981 8244/msp/A/08.2011 Page 4/5

+ Probe series testo 661x The following options can be specified for the : Bxx Cxx Dxx Exx Fxx Gxx Hxx Ixx Analog output / supply Display / menu language Cable entry Ethernet Humidity / temperature unit Humidity / temperature unit Relay Humidity / temperature unit (optional) Example: Order code for transmitter with the following options: - Housing with display with menu setting English - 4 to 20 ma (4-wire) - Cable entry M16/M20 - Etherne module - Factory configuration Channel 1: Ctpd with scaling min 0 Ctd, max 100 Ctd* - Factory configuration Channel 2: C with scaling min -10 C/-14 F - max +70 C/+158 F* - with relay - without 3rd channel Bxx Analog output / supply Gxx Humidity/temperature unit B01 4 to 20 ma (2-wire, 24 VDC), not possible with G01 %RH relay, Ethernet module or probe testo 6614/6615 G02 C B02 0 to 1 V (4-wire, 24 VAC/DC) G03 F B03 0 to 5 V (4-wire, 24 VAC/DC) G04 C td B04 0 to 10 V (4-wire, 24 VAC/DC) G05 F td B05 0 to 20 ma (4-wire, 24 VAC/DC) G06 g/kg B06 4 to 20 ma (4-wire, 24 VAC/DC) G07 gr/lb B77 Profibus-DP G08 g/m 3 G09 gr/ft 3 Cxx Display/menu language G10 ppmv G11 Cwb (wet bulb) C00 without display / without operating menu Clear G12 Fwb (wet bulb) C02 with display and operating menu / English text G13 kj/kg (enthalpy in air) C03 with display and operating menu / German language. G14 hpa / max (water vapour partial pressure) C04 with display and operating menu / French OperatingG15 inch H C05 with display and operating menu / Spanish 2 O (water vapour partial menu pressure) C06 with display and operating menu / Italian only G18 %Vol. C07 with display and operating menu / Japaneseavailable C08 with display and operating menu / Swedish with display. Hxx Relay Dxx Cable entry D01 Cable entry M16 (relay: M20) D02 Cable entry NPT ½ D03 Cable contact via M plug connection for signal and supply (for optionale relay: M20 cable entry) Exx Ethernet E00 Without Ethernet module E01 With Ethernet module Fxx Humidity/temperature unit F01 %RH F02 C F03 F F04 C td F05 F td F06 g/kg F07 gr/lb F08 g/m 3 F09 gr/ft 3 F10 ppmv F11 Cwb (wet bulb) F12 Fwb (wet bulb) F13 kj/kg (enthalpy in air) F14 hpa / max (water vapour partial pressure) F15 inch H 2 O (water vapour partial pressure) F18 %Vol. Channel 1* H00 Without relay H01 4 relay outputs, limit value monitoring H02 4 relay outputs, limit values Channel 1 + collective alarm Channel 2* not with B01 Ixx Humidity/temperature unit (optional) I00 no optional 3rd analog output I01 %RH I02 C I03 F I04 C td I05 F td I06 g/kg I07 gr/lb I08 g/m 3 I09 gr/ft 3 I10 ppmv I11 Cwb (wet bulb) I12 Fwb (wet bulb) I13 kj/kg (enthalpy) I14 hpa (water vapour partial pressure) I15 inch H 2 O (water vapour partial pressure) I16 Ctm / mixture dewpoint for H 2 I17 Ftm / mixture dewpoint for H 2 I18 %Vol. Channel 3* 0555 6681 A01 B06 C02 D01 E01 F03 F04 0 100 G02-10 +70 H01 I00 The following options can be specified for the probe testo 661x: Lxx Mxx Nxx Pxx Probe version Protective cap Probe shaft length Probe length / length mm Lxx L11 L12 L13 L14 L15 L17 Probe version Probe 6611 (wall version) Probe 6612 (duct version up to 150 C) Probe 6613 (duct version up to 180 C) Probe 6614 (heated cable version) Probe 6615 (trace humidity cable version) Probe 6617 (self-monitored cable version) N00 Without cable (only L11) N01 Probe length 1 m (not for L11, L12) N02 Probe length 2 m (not for L11, L12) N05 Probe length 5 m (not for L11, L12) N10 Probe length 10 m (not for L11, L12) N23 Probe length 0.6 m, specially for duct versions (only L12) Page 5/5 Example: Order code for probe testo 6613 with the following options: - Cable probe, -40 to +180 C - Sintered stainless steel filter - Cable length 2 m - Probe length 300 mm Protective cap M01 Stainless steel protective cap M02 Wire mesh protective filter M03 PTFE protective cap M04 Metal protective cap, open M06 PTFE protective cap with condensate drip hole M07 PTFE protective cap with condensation protection and condensate drip hole M08 Protective cap for H2O2 atmospheres Nxx Probe length / length mm 0555 6610 L13 M01 N02 P30 * The standard scaling is supplied if "min" and "max" are not specified. Pxx Probe length / length mm P07 Probe length 70 mm (only L11) P12 Probe length 120 mm (only L13) P20 Probe length 200 mm P30 Probe length 300 mm (only L12, L13, L14) P50 Probe length 500 mm (not with L11) P80 Probe length 800 mm (only L12, L13) ** Plug connection M12, 5-pin plug and socket available as accessories. 0981 8244/msp/A/08.2011

+ Probe series testo 661x 0981 8244/msp/A/08.2011 Page 6/6