COMMENTS: PLEASE SEE A/E COMMENTS

Similar documents
TR150 DRIVE STANDARD FEATURES

VLT 2800 DRIVE SPECIFICATIONS

TR200 DRIVE STANDARD FEATURES

TR200 DRIVE WITH ELECTRONICALLY CONTROLLED BYPASS SYSTEM

Submittal Data Information SmartDRIVE HVAC Variable Speed Drives

Submittal Data Information SmartDRIVE SP Variable Speed Drives

Submittal Data Information SmartDRIVE VP Variable Speed Drives

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

PowerFlex 400 AC Drive Guide Specification

VLT The Real Drive for HVAC. The VLT 6000 is a. totally new adjustable. frequency drive, with. control functions and. software designed solely

TR200 TM Series. Variable Frequency Drives BAS-PRC034-EN. December R0643

SECTION VARIABLE FREQUENCY DRIVES

A drive dedicated to variable speed control for HVAC applications

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

VFD 4x STAINLESS STEEL ENCLOSURE WITH AC. engineering data and specifications

PART 1: GENERAL PART 2: PRODUCT. Phone: Fax: Web: -

Q9 ASD LOW VOLTAGE DRIVE

PowerFlex 40 Sample Specification

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

ADJUSTABLE SPEED DRIVES. Q9 Series

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

ACH550 Product Overview

SED2 Variable Frequency Drives

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

AF-600 FP AC Drive AC Adjustable Frequency Drive Guide-Form Specification

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet


MC Series Drives. Flexible, simple, rugged, robust!

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Submittal Schedule Details for VFD-P101, P201, P202, P310, P302, P401, P402

Easy To Use OEMS Take Note

Specification Number: Product Name: FRENIC-Mega AC Drives for General Purpose Applications (½ - 150Hp at 230V and ½ Hp at 460V)

VLT HVAC Drive Solutions

HVAC Products. Introducing the SED2 Variable Frequency Drives

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

STANDARD SUBMITTAL PACKAGE

BuildingName The Description of the Project P DOCUMENTS

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

VLT HVAC Drives A complete range of advanced solutions. Energy reduction

CONTENTS. Date Description of Change Pages / Sections Modified

ADJUSTABLE SPEED DRIVES. GX7 Series

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

160 AA02SF1 AF DS-D17

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

IPS INTELLIGENT PUMP STARTER

Baltimore Aircoil Company

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV1200A kv kva

Installation, Operation and Maintenance Manual

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

SECTION VARIABLE FREQUENCY MOTOR CONTROLLERS (VFD)

Optidrive Applications Support Library

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

VLT Micro Drive. Ready Set Go!

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Technologic 502 Variable Speed Pump Controller

The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP

SmartVFD HVAC and BYPASS

Built-in features Built-in simplicity Built for fans & pumps

AC Tech. Variable Speed AC Motor Drives. SCN Series Installation and Operation Manual

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

QUICK REFERENCE GUIDE

Table of Contents 1. Overview Installation...6

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

SED2 Variable Frequency Drives

SECTION LOW-VOLTAGE VARIABLE FREQUENCY DRIVES

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

PowerXL DG1 Product Overview Eaton Corporation. All rights reserved.

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

The VLT Micro Drive Small drive maximum strength and reliability

RT4F-110V/25A RECTIFIER

SENSORLESS VECTOR CONTROL

E1 Plus Electronic Overload Relay

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

INTRODUCING THE S V ADJUSTABLE SPEED DRIVE

AIR COOLED MODULAR RECTIFIER

VARIABLE SPEED DRIVES VLA1 SERIES

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

Transcription:

OCPS CLAY SPRINGS ES SUBMITTAL DETAILS: BUILDING REFERENCE: SUBJECT: ADJUSTABLE FREQUENCY DRIVES PD - RESUBMITTED 2 TIME(S) DATE RECIEVED: Jan 15, 2015 DISCIPLINE: Mechanical PRIORITY STATUS: 2-STANDARD SPECIFICATION REF: REVIEWER DUE DATE: 1/21/2015 DWG REF. DWG TITLE: RETURNED ITEMS: NONE NO OF ITEMS: ITEM DESCRIPTI CONTRACTOR/CM: SUBMITTAL TRANSMITTAL SUBMITTAL NUMBER: 230517-01.02 : WILLIAMS COMPANY : BRAD KUBIN 2301 SILVER STAR RD. ORLANDO, FL, 32809 (407) 295-2530 FAX:(407) 297-0459 DATE RETURNED TO CM: 1/19/2015 1 Product Literature(s) REVIEW STATUS: REVIEWERS: PRIMARY: SECONDARY: KEVIN KING MATERN ENGINEERING PHN: (407) 740-5020 FAX: (407) 740-0365 kking@matern.net TAD RIVENBARK MATERN ENGINEERING PHN: (407) 740-5020 FAX: (407) 740-0365 trivenbark@matern.net COMMENTS: PLEASE SEE A/E COMMENTS RE-SUBMIT WITH SPECIFIED ITEMS cc: OWNER : CALVIN WOOLFOLK 6501 MAGIC WAY, BLDG. 200 ORLANDO, FL, 32809 (407) 317-3700 FAX:(407) 317-3768 R+B FILE: : 13017-0001.X6 RHODES + BRITO ARCHITECTS INC. : 605 E. ROBINSON STREET, SUITE 750 : ORLANDO, FL. : 32801 : 407.648.7288 : FAX.648.7289 PAGE 1 OF 1

OCPS CLAY SPRINGS ES SUBMITTAL DETAILS: SUBJECT: DATE RFI RECIEVED: Jan 15, 2015 DISCIPLINE: Mechanical PRIORITY STATUS: 2-STANDARD SPECIFICATION REF: REVIEWER DUE DATE: 1/21/2015 DWG REF. DWG TITLE: SUBMITTAL CONTENTS: ADJUSTABLE FREQUENCY DRIVES PD -RESUBMITTED 2 TIME(S) NONE NO OF ITEMS: ITEM DESCRIPTION 1 PRODUCT LITERATURE(S) REVIEWERS: PRIMARY: SECONDARY: SUBMITTAL ASSIGNMENT MEMO KEVIN KING PHN: (407) 740-5020 FAX: (407) 740-0365 kking@matern.net TAD RIVENBARK SUBMITTAL NUMBER: 23051701.02 MATERN ENGINEERING MATERN ENGINEERING PHN: (407) 740-5020 FAX: (407) 740-0365 trivenbark@matern.net REVIEW STATUS: REVIEWED FURNISHED AS MARKED REVISE AND RESUBMIT RE-SUBMIT WITH ITEMS NOT REVIEWED REJECTED THIS SUBMITTAL IS ISSUED TO YOU FOR YOUR REVIEW. PLEASE RESPOND AND RETURN...WITH THIS COMPLETED SAM TRANSMITTAL...TO MICHELE BUDAY-URDANETA NO LATER THAN: 1/21/2015. PLEASE COMPLETE REVIEW STATUS AT RIGHT COMMENTS: THIS SUBMITTAL WAS REVIEWED BY : (please print) cc: OWNER : CALVIN WOOLFOLK 6501 MAGIC WAY, BLDG. 200 ORLANDO, FL, 32809 CONTR/CM: : WILLIAMS COMPANY : BRAD KUBIN 2301 SILVER STAR RD. R+B FILE: : 13017-0001.X6

Submittal Approval Form PROJECT: CLAY SPRINGS ELEMENTARY SCHOOL DATE: SUBCONTRACTOR NAME: DHR Mechanical Services Inc. SUBCONTRATOR ADDRESS: 801 Central Park Drive Sanford FL. 32771_ NUMBER AND TITLE OF SPECIFICATION SECTION: 23 05 17 Adjustable Frequency Drives PD Contractor s Submittal Stamp Architect/ Engineer s Submittal Stamp 1/14/15

SUBMITTAL DATA REVIEW COMMENTS Date: January 17, 2015 MPE Project No: 2013-224 Project: By: Submittal: OCPS-Clay Springs ES J. Walden for Kevin King Adjustable Frequency Drives Data No.: 23 05 17.02 Submittal No.: 001 Contractor s I.D.: DHR Class: Basis of Design (1) Equal (2) Substitution (3) A No exceptions taken. B Make corrections noted. C Revise and Resubmit. X D Submit Specified Item. E Rejected. N Review not required. ACTION CODE THE FOLLOWING COMMENTS SHALL BE CONSIDERED AN INTEGRAL PART OF THE SUBMITTAL DATA REVIEW. REVIEW OF THIS DATA IS ONLY FOR CONFORMANCE WITH THE DESIGN CONCEPT AS GIVEN IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR: QUANTITIES, FUNCTIONS, DIMENSIONS AND COORDINATION OF THE WORK WITH OTHER TRADES. 1. Submit a Harmonic Analysis as per specifications. END OF SUBMITTAL DATA REVIEW COMMENTS Corporate Office: 130 Candace Drive, Maitland, Florida 32751-3331 Phone: 407.740.5020 Orlando Fort Myers Jacksonville Tampa www.matern.net Registered: FLORIDA * GEORGIA* LOUISIANA * NORTH CAROLINA * SOUTH CAROLINA * TEXAS * TENNESSEE * VIRGINIA

Revised Submittal Prepared For: MPE Sold To: DHR Mechanical Services Date: September 15, 2014 Job Name: OCPS Clay Springs Elementary School Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 8 Variable Frequency Drives Trane branded variable frequency drives are manufactured by Danfoss and based on the TR200 design The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Kelly Carlson Trane 2301 Lucien Way, Suite 430 Maitland, FL 32751 Phone: (407) 660-1187 Cell: (321) 284-5801 Fax: (407) 660-0303 J:\JOBS\43\115698\7\VFD Submittal.doc Equipment Submittal Page 1 of 18

460 Volt EMB2 Bypass Packages Frame Size Nominal Max. Amps Qty. Tag Numbers HP NEMA1 TR200 Model Voltage Output 2 AHU 1-3 AHU 1-6 5 A2/A5 TR200P3K7T4 460 7.6 1 AHU 1-4 7.5 A3/A5 TR200P5K5T4 460 11 1 AHU 1-1 4 Exclusions Floor stands AHU 1-2 AHU 1-5 AHU 2-1 AHU 2-2 DUAL HP 5 X 5 DUAL HP 7.5 X 7.5 B1 TR200P11KT4 460 21 B1 TR200P15KT4 460 27 Eight (8) Variable Frequency Drives Serving: AHU 1-1, 1-2, 1-3, 1-4, 1-5, 1-6, 2-1, 2-2 Product Data 460V/3Ph 6 Pulse NEMA 1 Main disconnects Drive fusing w/ 100K AIC Common run/stop Under voltage relay RFI/EMI filter Dual DC Link Reactor (Equivalent to 5% AC input line reactor) Manufacture assisted start-up 36 month parts and labor warranty Equipment Submittal Page 2 of 18

ELECTRO-MECHANICALLY CONTROLLED BYPASS (EMB2) FEATURES General Features All optional features shall be built, mounted and tested by TRANE. The factory warranty will apply to the entire assembly as shipped. All options will carry a UL / C-UL Enclosed Industrial Control Panel label. All optional devices will be factory tested as assembly. Bypass Power Features Contactor bypass will be provided that allows operation of the motor via line power in the event of a failure of the VFD. Motor control selection shall be through either a VFD output contactor or a bypass contactor that is interlocked to ensure that both contactors are not energized simultaneously. Main input disconnect will be provided that removes power from both the bypass and VFD. VFD-only, fast acting input fuses will be provided. Overload protection will be supplied in bypass mode. o Adjustable current setting for complete motor protection when operating on line power. o Overload protection shall include phase loss and phase imbalance protection. o Visual indication of an overload trip condition shall be displayed on the VFD keypad. o Resetting an overload trip condition shall not require the opening of the enclosure door for safety reasons and shall be accomplished via a digital input, door mounted device (drive keypad), or over the serial communications. Bypass Power Options use left column to indicate desired options X X A third contactor, the drive input contactor, will be supplied. This allows powering of the VFD with the motor off or operating in bypass mode for testing, programming and troubleshooting purposes 100kA Short Circuit Current Rating for Panels without circuit breaker. Includes main fusing which protects entire assembly. Equipment Submittal Page 3 of 18

Bypass Interface and Control Features Bypass or VFD selection shall be via a DRIVE OFF BYPASS selector switch. A BYPASS pilot light will illuminate when operating in bypass mode. Units that include an optional drive input contactor shall include a fourth switch position; TEST. This shall allow the ability to supply power to the drive for testing purposes while running the motor in bypass. Selection of Bypass or VFD operation will be by any one of the following: Manually via the VFD keypad, remotely via a contact closure from the BMS system, commanded over the communication network or automatic bypass operation based on VFD programming. Bypass package will include an External Safety interlock that will disable motor operation in either bypass or VFD mode when open. EMB2 control package will be provided. This package includes the following features: o There shall be complete Common Start/Stop command when operating in either Bypass or VFD mode. While operating in Bypass mode, the keypad shall allow the selection of Hand or Remote motor starting. In Hand and Bypass modes, pushing the keypad start button shall initiate motor operation via line power. When in Remote and Bypass modes are selected, the motor shall start just as it would have in VFD and Remote mode. This start source can be via either a hardwired start command, the VFD s real time clock or a command over BAS communication. This feature allows energy savings over standard bypass packages by allowing nighttime shutdown schedules and load shedding even with a VFD failure. Bypass packages that only allow common remote start / stop command when this command is hardwired to the package are not acceptable. o Selectable Run Permissive logic shall operate in either VFD or bypass operation. When activated, any command to start the motor, in either Hand Bypass, Remote Bypass, Hand VFD or Remote VFD shall not start the motor, but instead close a relay contact that is used to initiate operation of another device, such as an outside air damper. A contact closure from this device shall confirm that it is appropriately actuated and the motor shall then start. o Firemode operation input shall be available. When closed, the motor will run in bypass mode regardless of operating mode selected and will ignore calls to stop. These include the opening of the external safety interlock circuit or the tripping of the motor overload. Additional Protective features In additional to the power and operational protective features listed above, each bypass will include the following: Low voltage contactor operation shall be maintained to 70% of the package s nominally rated voltage. This will ensure VFD operation on low voltage conditions that would otherwise be interrupted due to contactor dropout. The VFD shall be able to operate the motor at a reduced load with the loss of any one of the three phases of power. Contactors shall remain closed regardless of which phase is lost. This will ensure VFD operation on single-phase conditions that would otherwise be interrupted due to contactor dropout. WARRANTY The standard 36 month warranty includes parts, labor, travel, and expenses. STARTUP An authorized service technician will perform a professional startup service. Equipment Submittal Page 4 of 18

DRIVE FEATURES OPERATOR INTERFACE The TR200 Drive The TR200 Drive Series is a microprocessor-based, high frequency IGBT-based, PWM AC drive with control functions and software designed solely for the unique needs of HVAC systems. The TR200 Drive uses state-of-the-art Voltage Vector Control to supply full rated motor voltage at rated load and frequency, full motor performance without derating, high efficiency for both drive and motor, and a nearly perfect output sine wave. The diode-bridge rectifier and DC-link reactor provide a high displacement power factor at all speeds and loads and minimize power line harmonics. The TR200 Drive utilizes a common user interface for all units. Fully Graphic, Multilingual Display The TR200 Drive uses a large, bright, backlit graphic display to provide complete drive information at a glance. The logical arrangement of all elements simplifies the setup, operation and monitoring of the drive. Choose from 25 different items to display, including input reference, motor current, hours run, output frequency, horsepower, kw or kwh. Or select from custom units, such as GPM or HP and calibrate the maximum value to the maximum frequency of the unit. After programming one drive, the keypad can be used to transfer the same settings to all other drives. Drive can run without the keypad in place to assure tamper-proof operation. Drive status is shown even with the keypad removed. LED Indication Three LEDs are provided on the TR200 Drive for indication of power applied, warning and fault. Upon power up, all LEDs will briefly light as a lamp test. Alarm Will flash red when the drive has registered a fault condition which has caused the drive to shut down. Warning Will flash yellow to indicate a situation exists that exceeds the normal drive/system parameters, and if that condition continues, a trip may be imminent. On Will glow green to indicate that the VFD is connected to AC power (line voltage is present). Operating Keys Hand On Starts the drive regardless of remote start/stop contact (assuming safety interlock is closed). The speed of the drive will generally be controlled manually via the keypad "+" and "-" buttons. Off Shuts the drive down regardless of other commands. Auto/On The drive will start and stop via the external contact closure (building automation time clock). The speed is generally controlled via the building automation signal (4 to 20 ma, 0 to 10 V DC, etc.). Reset Will reset any trip level fault (not trip lock) if the drive is not set for infinite automatic fault resets. Directional Keys Right / Left / Up / Down arrows Used as the electronic potentiometer to manually control the speed in the Hand/Start mode. All four keys are active during operation as well as programming. They provide the ability to move the cursor around the display, or sequence through display values. Programming Keys Status Used to display operational data and status. Cancel Used to cancel the last programming command so the change is not carried out. OK Used to confirm that the last programming change should be saved to memory. Back Used to exit present display or menu to the previous display or menu. Quick Menu Used for programming the TR200 Drive for the most typical applications. Main Menu Used to access all parameters for programming. It can switch directly from this mode to quick menu. Alarm Menu Used to access all fault and warning data. Info Key Accesses an on-board manual that gives detailed explanation of a parameter. Equipment Submittal Page 5 of 18

PROGRAM OPTIONS Application-Specific Software The TR200 Drive was designed specifically for the HVAC market. This specialization has allowed TRANE to factory program and configure the TR200 Drive to make it ready to use, out of the box. This eliminates the time-consuming and often confusing job of selecting the correct parameters in the field. For the advanced user, the parameters are logically grouped, making modifications simple. Customized text fields are available to show user-specific data. Four independent setups are available for unmatched flexibility. Menu Structure Quick Setup Menu Contains the 14 required setup parameters to easily start the application. HVAC Application Menu Easy access to the most relevant parameters for each of the most common HVAC applications. Personal Menu Contains up to 20 user-selectable parameters for customized access. Changes Made Menu Provides easy access to previously modified parameters Keypad Features Hot-pluggable with upload and download capabilities On-screen scroll bars and graphs Up to five separate meters displayed simultaneously Two-level password protection Plain language alarms and warnings Remote keypad mounting kits available USB Connectivity The TR200 Drive can be remotely commissioned and monitored through a standard USB connection and TDU 10 PC software. Agency listing: All drives and option packages are factory built and carry UL and C UL listings. All drives and option packages are built in ISO 9000 and 14001 certified facilities. Equipment Submittal Page 6 of 18

DRIVE FEATURES MOTOR AND DRIVE INTERACTION Constant-Torque Start The TR200 Drive s constant-torque start mode provides full torque to accelerate different loads until the drive reaches the setpoint. Breakaway current can be set up to 160% for up to 0.5 seconds for starting high friction loads. Current Limit Circuit Adjustable from 0 to 110% of the TR200 Drive's rated current (factory set at 110%). If during acceleration the current required to accelerate the load exceeds the current limit, the TR200 Drive will stop accelerating until the motor current is reduced to normal levels, at which time the load will continue to accelerate at the rate set by the acceleration time. Three-Phase Output Current Measurement The TR200 Drive s software measures output current on all three phases. Phase grounding is detected instantly. Output contactors may be repeatedly used with no damage to the drive. Multiple motors may be run from one drive. Advanced Motor Protection The TR200 Drive features integrated electronic, thermal motor protection. The VFD calculates the motor temperature based on current, frequency, and time. This system allows for changing cooling conditions as speed and load vary. The drive can predict motor overheating and reports a % of thermal load. Motor Preheat Circuit This preheat function can be activated to avoid condensation on the motor windings when it is stopped. Stall Protection The TR200 Drive provides protection against a stalled motor. When activated, this function can provide a warning or a fault condition caused by excessive motor current at low speeds. DRIVE FEATURES DC-Link Reactor A dual, 5% DC-link reactor on the positive and negative rails of the DC bus is standard equipment on the TR200 Drive. This reactor reduces the level of harmonics reflected back into the building power system without causing a voltage loss at the drive s input and reducing efficiency as an external AC line reactor would. This reactor also improves input power factor. The reactor is non-saturating (linear) to provide full harmonic filtering throughout the entire load range. In performance, the DC-link reactor is equivalent to a 5% AC line reactor. Power Line Protection Power line voltage surge protection is provided by means of input Metal Oxide Varistors (MOVs). This protects the diodes in the TR200 Drive s 3-phase full wave diode bridge. The DC-link reactor also acts to reduce input current caused by power line disturbances. Sleep Mode Automatically stops the drive when speed drops below set "sleep" level for specified time. Automatically restarts when speed command exceeds set "wake" level. Saves energy and reduces wear on driven equipment. Run Permissive Circuit Ability to accept a "system ready" signal assures that dampers or other auxiliary equipment are in the proper state for drive operation. This feature also provides the ability for the drive to send a start signal applied signal to the system to notify the auxiliary equipment of the drive s request to start. Firefighter s Override Mode Overrides all other commands to provide desired operation. Ignores most alarms including overload, overcurrent, overtemperature, and phase loss. When used with bypass, selectable to run from drive, from bypass, or switch from drive to bypass in the event of a drive failure. Equipment Submittal Page 7 of 18

Acceleration / Deceleration Rates The TR200 Drive can provide four individually controlled sets of acceleration/deceleration rates each from 1 to 3600 seconds. The shape of these curves may be automatically contoured to prevent tripping. The TR200 shall also provide an S-Curve shaped acceleration/deceleration ramp. Plenum Rated The TR200 NEMA 1 or NEMA 12 drive is recognized by UL for installation in air handling compartments. Auto Restarts The TR200 Drive can be automatically restarted up to 20 times or infinitely at 0 to 600 second intervals. If the application causes the drive to trip more than the number of trials set, the drive will stop operating and display the fault on the display screen. A manual reset will be required by means of the reset key, a digital input, or EIA 485 command. In cases of severe trips, as a safety feature, the drive's input power may have to be cycled to restart a fault. Carrier Frequency By using IGBTs, the TR200 Drive can employ high switching frequencies, so the motor current is practically sinusoidal. Audible motor noise can also be minimized by adjusting the switching frequency. These frequencies can be set or adjust themselves automatically to fit the application. Input Power The TR200 Drive is equipped with an automatic sustained power or phase loss circuit. The TR200 Drive will provide a full rated output with an input voltage as low as 90% of the nominal. The drive will continue to operate with reduced output with an input voltage as low as 164 volts for 208/230 volt units, 313 volts for 460 volt units, and 394 volts for 600 volt units. Automatic Motor Adaptation (AMA) Knowing motor stator resistance, the drive automatically optimizes performance and efficiency. The motor does not have to be run or decoupled from the load for the AMA setup to be performed. Automated Frequency Avoidance / Critical Frequency Lockouts For applications where it may be necessary to avoid specific frequencies due to mechanical resonance problems in the driven equipment, the TR200 Drive, with its Critical Frequency Lockout Function, makes it possible to set up to four different frequency ranges which will be avoided during operation of the drive. This feature can be programmed by simply activating the feature and pushing OK at the top and bottom points that you wish to avoid. Each critical frequency setting can avoid a frequency band which is from 1 to 100 Hz wide. If the reference signal defines that the TR200 Drive is to operate within this critical frequency range, the critical frequency lockout function will keep the drive operating continuously within this range. When the frequency reference signal rises above the critical frequency maximum limit, the TR200 Drive will allow the motor to accelerate through the critical frequency at the rate set by the acceleration rate. Automatic Energy Optimization Circuitry The Automatic Energy Optimization (AEO) function adapts the output of the drive to the specific motor and load connected. This circuit optimizes the system efficiency as system loads change. The AEO function regulates the output voltage on the basis of the reactive current and the effective current. A savings of 3 to 10% in power consumption can be obtained with this function. Preset Speeds The TR200 Drive allows for a maximum of 16 programmable preset speeds to be selected from the digital inputs. Energy Monitoring Real energy savings are always available without the additional expense of external equipment. Equipment Submittal Page 8 of 18

Automatic High Ambient Derate If the ambient temperature exceeds the normal limit, the drive can be set to warn of its over temperature and continue to run, keeping the HVAC system functional. To control its temperature, the drive will reduce the output carrier frequency and then, if necessary, reduce the output current. Preventive Maintenance Scheduling The TR200 Drive can monitor system usage and notify the operator when preventive maintenance is required. Intelligent HVAC Controller Four auto-tuning PIDs control the drive and up to three other devices, eliminating external controllers and reducing cost. Proportional: The proportional gain dictates the rate at which the deviation between actual and desired feedback signal is corrected. The higher the gain, the faster the response, but too high a gain can cause hunting and a large overshoot. Integral Time: The integral time continually compares the feedback value with the desired set point over time to make sure the set point is reached. The greater the integral time, the longer it takes to actually achieve the set point, but improves the system stability. Derivative: The derivative function monitors the rate at which the feedback is closing on the desired set point and slows the rate of approach to prevent overshooting. This function allows rapid accurate system control. Built-in Communications The TR200 Drive is fully equipped for serial communication (EIA 485). Up to 31 drives can be connected to one serial bus up to 5,000 feet long. Communicates directly with Johnson Controls Metasys (N2), Siemens Building Technologies System 600 (FLN), and Modbus RTU systems with no hardware changes or additional costs. Optional communications include BACnet MS/TP and LonWorks with the addition of an Option A card. Broken Belt, Loss of Load A minimum motor current value can be set to indicate the motor is not using any more current than to run at idle. This can be used to indicate a broken belt or coupler. This feature can also be used to detect when a motor is disconnected from the drive. Equipment Submittal Page 9 of 18

SPECIFICATIONS Drive Input Power Input voltage, 3 phase... 200 240, or 380 460, or 525 600 VAC Input voltage range for full output... Nominal ±10% Undervoltage trip point... 164, 313 VAC, or 394 VAC Overvoltage trip point... 299, 538, or 690 (792 for 100 HP and above) VAC Input frequency... 50 or 60 Hz, ± 2 Hz Displacement Power factor... 0.98 or greater at all speeds and loads Total Power factor... 0.90 or greater at full load and nominal motor speed Drive Output Power Output frequency... Selectable 0 to 120 Hz Motor voltages... 200, 208, 220, 230; 380, 400, 415, 440, 460; 550 or 575 VAC Continuous output current... 100% rated current Output current limit setting... Adjustable to 110% of drive rating Current limit timer... 0 to 60 seconds or infinite Adjustable maximum speed... From minimum speed setting to 120 Hz Adjustable minimum speed... From maximum speed setting to 0 Hz Acceleration time... To 3,600 seconds to base speed Deceleration time... To 3,600 seconds from base speed Breakaway torque time... 0.0 to 0.5 seconds (1.6 times motor nameplate current) Start voltage... 0 to 10% DC braking time... 0 to 60 seconds DC braking start... 0 to maximum frequency DC braking current... 0 to 50% of rated motor current Environmental limits: Efficiency... 97% or greater at full load and nominal motor speed Ambient operating temperature... 14 F to 113 F (-10 C to 45 C) frames A2 C2; 14 F to 104 F (-10 C to 40 C) frames D1 E1 Humidity... < 95%, non-condensing Altitude: maximum without derating... 3,300 ft. (1,000 m) Drive and options enclosure(s)... NEMA/UL Types 1 and 12; as noted Equipment Submittal Page 10 of 18

Software Lost speed reference action... Selectable to go to a preset speed, go to maximum speed, stay at last speed, stop, turn off, or stop and trip Time delay for lost speed reference action... 1 to 99 seconds Adjustable auto restart time delay... 0 to 600 seconds Automatic restart attempts... 0 to 20 or infinite Automatic restart time delay... 0 to 600 seconds between each attempt Relay ON delay and relay OFF delay... 0 to 600 seconds Maximum number of preset speeds... 16 Maximum number of frequency stepovers... 4 Maximum stepover width... 100 Hz Maximum number of accel rates... 4 Maximum number of decel rates... 4 Delayed Start... 0 to 120 seconds Equipment Submittal Page 11 of 18

Protections: Low frequency and high frequency warnings... 0 to 120 Hz Low current and high current warnings... 0 to maximum current Low reference and high reference warnings... -999,999 to 999,999 Low feedback and high feedback warnings... -999,999 to 999,999 Ground fault... Protected Motor stall... Protected Motor over temperature... Protected (Predictive motor temperature) Motor Condensation... Protected (Motor pre-heat circuit) Pump No-Flow... Protected Pump end-of-curve... Protected Dry pump... Protected Short-cycle... Protected Motor overload... Protected (Programmable action) Vibration protection... Protected (Programming automated) Control Connections Follower signal, analog input... 2; selectable voltage or current, direct and inverse acting Programmable digital inputs... 6 (2 can be used as digital outputs) Programmable analog outputs... 1; 0/4 to 20 ma Programmable relay outputs... 2 standard Form C 240 V AC, 2 A; 1 or 3 additional optional Auxiliary voltage... +24 V DC, maximum 200 ma Control Optional MCB 101 General Purpose I/O... 3 DI, 2 DO, 2 AI (voltage), and 1 AO (current) MCB 105 Relay Card... 3 standard Form C 240 VAC, 2 A MCB 107 24V DC Supply... Allows external 24 V DC power to be connected to the TR200 Drive MCB 115 Programmable I/O... Available 2 nd half of 2009 Equipment Submittal Page 12 of 18

Serving Tags: AHUs 1-1, 1-2, 1-5, 2-1 & 2-2 Equipment Submittal Page 13 of 18

Serving Tags: AHUs 1-1, 1-2, 1-5, 2-1 & 2-2 Equipment Submittal Page 14 of 18

Serving Tags: AHUs 1-1, 1-2, 1-5, 2-1 & 2-2 Equipment Submittal Page 15 of 18

Serving Tags: AHUs 1-3, 1-4, & 1-6 Equipment Submittal Page 16 of 18

Serving Tags: AHUs 1-3, 1-4, & 1-6 Equipment Submittal Page 17 of 18

Serving Tags: AHUs 1-3, 1-4, & 1-6 Equipment Submittal Page 18 of 18