D2SW-3L1HS D2SW-01L1HS

Similar documents
Actuator Terminal Model

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB

Pin plunger D2JW-011 D2JW-011-MD. Short hinge lever D2JW-01K1A1 D2JW-01K1A1-MD. Hinge lever D2JW-01K11 D2JW-01K11-MD

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

masterelectronics.com onlinecomponents.com

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Special-purpose Basic Switch

Solder terminals D2FD-2L0-1H D2FD-01L0-1H. PCB terminals D2FD-2L0-1T D2FD-01L0-1T. Hinge lever Solder terminals D2FD-2L1-1H D2FD-01L1-1H

Quick-connect terminals (#110)

Miniature Basic Switch

Add S to the end of the model number for the UL/CSA-approved version. Consult your OMRON sales representative for details.

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

D2F. Ultra Subminiature Basic Switch with plenty of terminal variations. Model Number Legend. Ultra Subminiature Basic Switch


Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

Snap Action Switch. General- Low force 25 g D2F-FL D2F-FL-T D2F-FL-D D2F-FL-A D2F-FL-A1

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

Z-15GW2277 Z-15GW2277-B

Top-actuated (B3U-1000 Series)

HIGH PERFORMANCE MINIATURE SWITCHES WITH WIDE RANGE

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

DPDT Basic Switch for Two Independent Circuit Control

General-purpose Limit Switch

Miniature Enclosed Limit Switch

14CESeries. Miniature Pre-Leaded Vertical Enclosed Switches

Actuator Series Common to Miniature, V-Size models

Inductive Proximity Sensor

Limit Switches E47 Precision Switches

Thread length (overall length) material

Model Number Structure

ZE/ZV/ZV2/XE/XV/XV2. (1) Built-in Switch (3) Actuator (4) Conduit/Ground Terminal *

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

Inductive Proximity Sensor

Miniature Basic Switch

SPST-NO SPDT DPST-NO DPDT

A K - J 3ML - 2

ZE/ZV/ZV2/XE/XV/XV2. General-purpose Enclosed Switches with High Breaking Capacity and High Durability. Enclosed Switches. Model Number Structure

2. Actuator B: Ball type P: Pin type F: Flat type

Model Number Structure

Cylindrical Proximity Sensor

AM5 (QV) SWITCHES. Automation Controls Catalog

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Compact-sized Snap Action Switches (Contact gap is more than 1mm) MQS-54AS Series 1/10

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Model Number Structure

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

V-3000 Series Miniature Basic Switches

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Switching Power Supply

Pre-wired Models. (1) (2) (3) (4) (1) Rated Current

Miniature Inductive Prox TL-W

Switching Power Supply

E2EC-CR8D2 5.4 mm dia. 1.5 mm (0.06 in) NO E2EC-C1R5D1 NC. E2EC-C1R5D2 8mmdia. 3 mm (0.12 in) NO E2EC-C3D1 NC

Safety Relay Unit (I/O Unit Type)

SUBMINIATURE MICROSWITCHES - SEALED

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Features Sealed Construction for Automatic Soldering. Contact form. Operating Force SPST- NO SPST- NO SPST- NO SPST- NO SPST- NO SPST- NO SPST- NO

Model Number Structure

Round Water-resistant Connectors (M8) XS3

Thread length (overall length)

Classification Enclosure rating Input voltage Type of

Round Water-resistant Connectors (M12) XS2

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Mini Photoelectric Sensor

Miniature Inductive Prox TL-W

Contents. Volume 8 Sensing Solutions CA E February

Pre-wired Models. (1) (2) (3) (4) (1) Rated Current

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Solid-state Timer H3YN

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

S8VE (60/90/120/180/240-W Models)

Technical Information Tactile Switches

SRT2-ROC08, SRT2-ROC16

Chemical Resistant Inductive Prox

MICRO SWITCH Sealed Subminiature Basic Switches. ZW Series. Datasheet

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

Devices raised mounting

I/O delay. (0.32 in ±0.06 in)

802B Compact, Precision and Small Precision

D3SH. List of Models. Surface Mount Switch S H SPST-NO SPST-NC. Long Lever Models. Standard Lever Models

Transcription:

Sealed Snap Action Switch D2SW Watertight Miniature Snap Action Switch High-quality watertight miniature Snap Action switch. Switch Body meets IP67 (IEC 529) requirements Monoblock construction assures high sealing capability and is ideal for dusty places or where water is sprayed Wide operating temperature range of -40 C to 85 C Perfect for the automobile, agriculture machinery, automatic vending machine, refrigerator, ice-manufacturing, hot-water supply, air conditioner, and industrial equipment, which require highly environment-resistive capabilities RoHS Compliant Ordering Information Actuator Terminal Model Model 3 A Model 0.1 A Pin plunger Solder terminals D2SW-3HS D2SW-01HS Quick-connect terminals (#110) D2SW-3TS D2SW-01TS PCB terminals D2SW-3DS D2SW-01DS With lead wires D2SW-3MS D2SW-01MS Hinge lever Solder terminals D2SW-3L1HS D2SW-01L1HS Quick-connect terminals (#110) D2SW-3L1TS D2SW-01L1TS PCB terminals D2SW-3L1DS D2SW-01L1DS With lead wires D2SW-3L1MS D2SW-01L1MS Simulated roller lever Solder terminals D2SW-3L3HS D2SW-01L3HS Quick-connect terminals (#110) D2SW-3L3TS D2SW-01L3TS PCB terminals D2SW-3L3DS D2SW-01L3DS With lead wires D2SW-3L3MS D2SW-01L3MS Hinge roller lever Solder terminals D2SW-3L2HS D2SW-01L2HS Quick-connect terminals (#110) D2SW-3L2TS D2SW-01L2TS PCB terminals D2SW-3L2DS D2SW-01L2DS With lead wires D2SW-3L2MS D2SW-01L2MS Note: 1. S at the end of the part number signifies UL/CSA approved models. 2. The standard lengths of the lead wires (UL1015 AWG22 for UL/CSA models, AV0.5f otherwise.) of models incorporating them are 30 cm. Model Number Legend D2SW- 1 2 3 4 1. Ratings 3: 3 A at 125 VAC 01: 0.1 A at 30 VDC 2. Actuator None: Pin plunger L1: Hinge lever L2: Hinge roller lever L3: Simulated roller lever 3. Contact Form None: SPDT -2: SPST-NC* -3: SPST-NO* *Lead wire versions only 4. Terminals H, HS: Solder terminals (HS for UL and CSA approval) D, DS: PCB terminals (DS for UL and CSA approval) T, TS: Quick-connect terminals (#110) (TS for UL and CSA approval) M, MS: Molded lead wires (MS for UL and CSA approval) Sealed Snap Action Switch D2SW 195

Specifications Characteristics Operating speed Operating frequency Note: 1. Data shown are of initial value. 2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate 3. For pin plunger models, the above values apply for use at the free position, operating position, and total travel position. For models with levers, the values apply at the total travel position. Ratings (reference values) D2SW-3 D2SW-01 Item D2SW-3 D2SW-01 0.1 mm to 1 m/second (at pin plunger) Mechanical: 300 operations/minute max. Electrical: 30 operations/minute max. Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 30 mω max. for terminal models 50 mω max. for terminal models 50 mω max. for lead wire models 70 mω max. for lead wire models Dielectric strength (See note 2) 1,000 VAC, 50/60 Hz for 1 min. between terminals of the same polarity 600 VAC, 50/60 Hz for 1 min. between terminals of the same polarity 1,500 VAC, 50/60 Hz for 1 min. between current-carrying metal parts and ground, and between each terminal and noncurrent-carrying metal parts Vibration resistance (See note 3) Malfunction: 10 to 55 Hz, 1.5 mm double amplitude Shock resistance (See note 3) Destruction: 1,000 m/s 2 (approx. 100G) max. Malfunction: 300 m/s 2 (approx. 30G) max. Ambient operating temperature -40 to 85 C (at 60% RH) with no icing Ambient operating humidity 95% max. (for 5 C to 35 C) Degree of protection IEC IP67 (excluding the terminals on terminal models) Degree of protection against electric shock Class I Proof tracking index (PTI) 175 Life expectancy Mechanical 5,000,000 operations min. at 60 operations per minute Electrical (30 operations per minute) Weight Terminal model Approx. 2 g Lead wire model Approx. 10 g 200,000 operations min. (3 A at 125 VAC) 100,000 operations min. (2 A at 250 VAC) 200,000 operations min. (at rated resistive load) Rated Voltage Non-inductive load (A) Inductive load Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 125 VAC 3 A 1 A 0.5 A 1 A 0.5 A 1 A 0.5 A 250 VAC 2 A 0.5 A 0.3 A 0.5 A 0.3 A 0.5 A 0.3 A 30 VDC 3 A 1 A 1 A 1 A Rated Voltage Non-inductive load Inductive load Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 125 VAC 0.1 A 30 VDC 0.1 A Note: 1. The resistive load ratings apply under the following test conditions: Ambient Temperature = 20±2 C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min. 2. The above current ratings are the values of the steady-state current. 3. Inductive load has a power factor of 0.7 min. (AC) and a time constant of 7 ms max. (DC). 4. Lamp load has an inrush current of 10 times the steady-state current. 5. Motor load has an inrush current of 6 times the steady-state current. 196 Sealed Snap Action Switch D2SW

Approvals Consult your OMRON sales representative for specific models with standard approvals. UL Recognized, CSA Certified Rated Voltage D2SW-3 D2SW-01 125 VAC 250 VAC 3 A 2 A EN 61058-1 (VDE Approval) 0.1 A - - - 30 VDC 3 A 0.1 A Rated Voltage 125 VAC 0.1 A D2SW-01 Testing conditions: 5E4 (50,000 operations), T85 (0 C to 85 C) Contact Specifications Item D2SW-3 D2SW-01 Specification Rivet Crossbar Material Silver Gold alloy Gap (standard value) 0.5 mm Inrush current NC: 20 A max. NO: 10 A max. 1 A max. Minimum applicable load 160 ma at 5 VDC 1 ma at 5 VDC (see note) Note: Minimum applicable loads are indicated by N standard reference values. This value represents the failure rate at a 60% (λ 60 ) reliability level (JIS C5003). The equation λ 60 =0.5 x 10-6 / operations indicates that a failure rate of 1/2,000,000 operations can be expected at a reliability level of 60% Engineering data Mounting All switches may be panel mounted using M2.3 mounting screws with plane washers or spring washers to securely mount the switch. Tighten the screws to a torque of 0.23 to 0.26 N m. Panel Mounting Two, 2.4-dia. mounting hole or M2.3 screw hole PCB Layout (reference) PCB Mounting Three, 1.35-dia. to 1.5 holes 8.8±0.2 16.1±0.2 9.5 Structure SPDT SPST-NC SPST-NO COM NO NC (Black*) (Blue*)(Red*) COM (Black) NC (Red) COM (Black) NO (Blue) *Indicates the color of the lead wire. Sealed Snap Action Switch D2SW 197

Dimensions Terminals Note: Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions Solder Terminals (HS) Quick-connect Terminals (#110) (TS) 3.3±0.1 7.3 0.55 1.8 1.6 0.8R 8.5±0.2 1.6 3.2 0.5 5.15 9.5±0.1 15.5±0.2 18.7±0.2 19.8±0.2 2.9 3.3±0.1 10.1 6.6 2.15 8.7±0.2 5.15 9.5±0.1 15.5±0.2 19.8±0.2 2.9 Three, 1.2 dia. holes Three, 2.8 0.5 PCB Terminals (DS) Molded Lead Wires 7.2 3.3±0.1 2.9 1.8±0.1 3.9 9.2 16.4 16.9 1.85 0.8 1.2 8.8±0.2 5.15 9.5±0.1 16.1±0.2 19.8±0.2 0.7 1.3 0.5 Common terminal (black) (see note) Vinyl insulator Normally open terminal (blue) (see note) 0.7 5.15 9.5±0.1 21.2 300±10 (5) Normally closed terminal (red)* Stranded annealed copper wires * UL/CSA approved models have UL approved AWG22 wiring. 198 Sealed Snap Action Switch D2SW

Dimensions and Operating Characteristics Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions 2. Omitted dimensions are the same as pin plunger type. 3. The following illustrations and dimensions are for models with solder terminals. Refer to Terminals for models with quick-connect (#110) and PCB terminals. 4. The operating characteristics are for operation in the A direction( ) Pin Plunger Models D2SW-3@S D2SW-01@S S 7.3 3.3±0.1 2.35 +0.1 0.05 2.5 dia.±0.07 0.55 1.8 dia. 1.8 1.6 7.5±0.1 A 8.5±0.2 5.15 9.5±0.1 15.5±0.2 18.7±0.2 19.8±0.2 2.35 +0.1 0.05 dia. holes 10.1 0.8R 1.6 3.2 7.7 PT 2.9 0.5 OF RF min. PT max. OT min. MD max. 180 gf 30 gf 0.6 mm 0.5 mm 0.1 mm 8.4 ± 0.3 mm Hinge Lever Models D2SW-3L1@S D2SW-01L1@S S t = 0.3 Stainless-steel lever 14.5 A FP 5.9 3.6 OF RF min. OT min. MD max. FP max. 60 gf 6 gf 1.0 mm 0.8 mm 13.6 mm 8.8 ± 0.8 mm Simulated Roller Lever Models D2SW-3L3@S D2SW-01L3@S S t = 0.3 Stainless-steel lever 15.8 1.3R A FP 5.9 3.6 OF RF min. OT min. MD max. FP max. 60 gf 6 gf 1.0 mm 0.8 mm 15.5 mm 10.7 ± 0.8 mm Hinge Roller Lever Models D2SW-3L2@S D2SW-01L2@S S t = 0.3 Stainless-steel lever 14.5 A FP 5.9 4.8 dia. 3.2 Polyacetal roller OF RF min. OT min. MD max. FP max. 60 gf 6 gf 1.0 mm 0.8 mm 19.3 mm 14.5 ± 0.8 mm Sealed Snap Action Switch D2SW 199

Precautions Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User s Guide, Snap Action Switches, Technical Information for correct use. Correct Use Operation stroke Make sure that the switching object is perfectly separated from the actuator when the switch is not operated and the actuator is pressed appropriately by the switching object when the switch is operated. The switch should be set so that its stroke will be within the rated OT when the switch is operated. Handling Install the switching object so that its moving direction is the same as that of the actuator. With the pin plunger models, set the switch so that the plunger can be actuated from directly above. Since the plunger is covered with a rubber cap, applying a force from lateral directions may cause damage to the plunger or reduction in the sealing capability. Correct Incorrect Incorrect Cautions Degree of Protection The D2SW was tested under water and passed the following watertightness test, which however, does not mean that the D2SW can be used in the water. JIS C0929 (rules for testing the watertightness of electrical devices and materials), class 7 (watertightness test). Refer to the following illustration for the test method. IEC Publication 529, class IP67. Refer to the following illustration for the test method. Note: The object to be tested is left in the water for 30 minutes on condition that the distance between the surface of the water and the top of the object be 15 cm minimum, and the distance between the surface of the water and the bottom of the object be 1 m minimum. Protection Against Chemicals Handle D2SW models with pin plungers with care so that the sealing rubber parts around the pin plungers will not be damaged. Make sure that there is no icing when using the D2SW at low ambient temperatures. Using Microloads Using a model for ordinary loads to switch microloads may result in faulty operation. Instead, use the models that are designed for microloads and that operate in the following range; Prevent the switch from coming into contact with oil and chemicals. Otherwise, damage and deterioration to the switch materials may occur. Soldering When soldering a lead wire to a terminal of the D2SW, use a soldering iron with a maximum capacity of 30 W and do not take more than 5 seconds to solder the lead wire, otherwise the characteristics of the D2SW may be altered. Voltage (V) Operating range for micro load models D2SW-01 Operating range for general-load models D2SW-3 Inoperable range Current (ma) However, even when using microload models within the operating range shown above, if inrush current or inductive voltage spikes occur when the contact is opened or closed, then contact wear may increase and so decrease the service life. Therefore, insert a contact protection circuit where necessary. 200 Sealed Snap Action Switch D2SW

Sealed Snap Action Switch D2SW MEMO

All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X303-E-1 11/10 Specifications subject to change without notice OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Printed in USA Sealed Snap Action Switch D2SW