IntesisBox DK-RC-MBS-1 v.0.8

Similar documents
IntesisBox DK-RC-MBS-1 v.0.2

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox PA-AC-MBS-1

IntesisBox TO-RC-MBS-1

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

IntesisBox ModBus RTU Fujitsu Air Conditioning

IntesisBox PA-AW-MBS-1 v.2.0

IntesisBox. v.1.3. User Manual Issue Date: 04/2016. IntesisBox PA-RC2-MBS-4

Modbus RTU (EIA-485) Interface for Panasonic and Sanyo air conditioners. Compatible with ECOi and PACi line models.

IntesisBox KNX. User Manual v10 r10 eng. Mitsubishi Electric air conditioners (Domestic & Mr.Slim lines) Release V.0.2

KLIC-DI COMMERCIAL PRODUCT MANUAL INTERFACE KNX COMMERCIAL A/C UNIT ZN1CL-KLIC-DI. Edition 8 Version 1.6

DK-AC-KNX-1. Specifications. Main features. Info

IntesisBox Modbus Server Hitachi VRF Air Conditioning. User Manual Issu Date: 11/2018 r1.0 EN

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng

USER'S MANUAL. IntesisBox KNX K01-KNX-1B/16/64 v1.0. r1 eng Issue Date: 2014/06

IntesisBox SMS - Mitsubishi Electric air conditioners

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

KLIC-DI VRV PRODUCT MANUAL INTERFACE KNX DAIKIN VRV ZN1CL-KLIC-DI. Edition 4 Version 1.0

IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML. User Manual Issue Date: 01/2018 r1.0 EN

Modbus Register Map: InRow ACRD60x / ACRC60x

The PanasonicVRF Driver

Panasonic/Sanyo A/C Interface Modbus TCP Installation Instructions

7. PCB AND FUNCTIONS

RTD-NET Installation Instructions

IntesisBox. for EnOcean

EXD-TEVI Economizer Controller for Tandem Compressors

Specifications Manual

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox HI-AW-KNX-1

4-step Chiller and Heat Pump Controller

RTD-W Installation Instructions

RS-FS-N01 Wind speed transmitter user's Guide (485type)

IntesisBox Modbus Server - BACnet/IP Client

BACnet MS/TP Interface User s Guide

OPERATION INSTRUCTIONS

Register Map: Ecoflair Indirect Air Economizer

IntesisBox Modbus Server KNX

UNIT CONTROLLER 8 (UC8) Modbus RTU communications

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Indoor Unit Controller (IUC) Quick Reference and Fault Diagnosis

IntesisBox Modbus Server Panasonic

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Modbus Server - Mitsubishi Electric G50

IntesisBox. Making Building Automation go further. LON Products

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

INTERFACE SPECIFICATION

IntesisBox Modbus Server M-Bus

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

MODEL: R2K-1 SEN TRONIC AG. R2K Series

RXTH DUAL ROOM SENSOR / SWITCH

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Gateway MODBUS-to-Opentherm MB-OTG Technical manual. Revision 1 SETECNA. Rel. Date 1 14/09/2016. Page: 1 di 10. Rev /09/2016

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Carbon Monoxide Sensor - ModBus

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Installation Manual. DZK BACnet

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

5 MICROMASTER 440 specifications

Communicative controller for VAV systems

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

M1000 INTELLIGENT ZONE CONTROL SYSTEM

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Modbus Server - Mitsubishi Electric G50

W8735A1013 EnviraCOM Serial Adapter

Remote I/O Communication Module Specification and Installation Instructions

RS-FX-N01 wind transmitter user's Guide (485type)

Dip Switch settings.

IntesisBox Modbus Server - LON

INDOOR UNIT CONTROLLER (IUC) Operation Manual

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Integrated Multi-Function

Trident and Trident X2 Digital Process and Temperature Panel Meter

MOD-RI Room Interface Modules with Modbus

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

RXTP ROOM TEMPERATURE

IntesisBox KNX - BACnet/IP Client

IntesisBox Modbus Server Siemens Synova FC330A

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

SX90 Process Controller

Quick Start Guide DDC (2014/02) Subject to change without prior notice Quick Start Guide

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD

MODBus RTU for AKOCAM and AKOPRO controllers

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

FCU-4 FAN COIL CONTROLLER

P3-SCM. General Specifications

Transcription:

IntesisBox DK-RC-MBS-1 v.0.8 MODBUS RTU (RS-485) Interface for Daikin air conditioners. Compatible with VRV and SKY line air conditioners commercialized by Daikin. User Manual Issue Date: 2013/02/26 Order Code: DK-RC-MBS-1

Intesis Software S.L. 2012. All Rights Reserved. Information in this document is subject to change without notice. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or any means electronic or mechanical, including photocopying and recording for any purpose other than the purchaser s personal use without the written permission of Intesis Software S.L. Intesis Software S.L. Milà i Fontanals, 1 bis 08700 Igualada Spain TRADEMARKS All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 2 / 17

INDEX 1. Presentation... 4 2. Connection... 5 2.1 Connection of the interface to the AC indoor unit... 5 2.2 Connection of the interface to Modbus... 5 3. Modbus Interface Specification... 6 3.1 Modbus physical layer... 6 3.2 Modbus Registers... 6 3.2.1 Control and status registers... 6 3.2.2 Configuration Registers... 7 3.2.3 Considerations on DK-RC-MBS-1 temperature registers... 8 3.3 DIP-switch Configuration Interface... 9 3.4 Implemented Functions... 11 3.5 Device LED indicator... 11 3.6 RS485 bus. Termination resistors and Fail Safe Biasing mechanism... 11 4. Specifications... 13 5. List of supported AC Unit Types.... 13 6. Error Codes... 14 7. Annex 1: Master of Mode... 17 3 / 17

1. Presentation The DK-RC-MBS-1 interface allows a complete and natural integration of Daikin air conditioners into Modbus RTU (RS-485) networks. Compatible with all SKY Air and VRV models commercialized by DAIKIN Reduced dimensions. 93 x 53 x 58 mm. Quick and easy installation. Mountable on DIN rail, wall, or even inside the indoor unit in some models of AC. External power not required. Direct connection to MODBUS RTU (RS-485) networks. Up to 63 DK-RC-MBS-1 devices can be connected in the same network. DK-RC-MBS-1 is a Modbus slave device. Direct connection to the AC indoor unit. Configuration from both on-board DIP-switches and MODBUS RTU. Total Control and Supervision. Real states of the AC unit's internal variables. Allows using simultaneously the IR and wired remote controls and MODBUS RTU. DK-RC-MBS-1 Modbus RTU RS485 network Modbus RTU master device Up to 63 AC indoor units DK-RC-MBS-1 SCADA PLC DDC BMS HMI Controller etc DK-RC-MBS-1 4 / 17

2. Connection 2.1 Connection of the interface to the AC indoor unit The DK-RC-MBS-1 connects directly to the Daikin P1/P2 Bus. Depending on which controllers are available the recommended connection methods are the following (details in Figure 2.1): Wired remote control available. Connect the gateway as Slave in parallel with the wired remote controllers (Wall controller acts as master). Infrared remote control available. Connect the gateway as Master in parallel with the infrared remote controller (Infrared receiver) as Slave. No remote control available Connect the gateway directly to the P1/P2 bus of the indoor unit as Master when there is no Daikin remote controller Disconnect mains power from the AC unit and use a 2 wire cable with a diameter of 0.75mm 2 to 1.25mm 2 for the connection of DK-RC-MBS-1, Daikin s remote controller and its corresponding indoor unit. Screw the suitably peeled cable ends in the corresponding P1/P2 terminals of each device, as summarized in Figure 2.1. Maximum P1/P2 bus length is 500 meter, cable has no polarity. 2.2 Connection of the interface to Modbus Use the EIA485 connector in the DK-RC-MBS-1 to connect to the Modbus network. 53 mm AC Indoor Unit Internal electronic control P1 P2 Remote Control DAIKIN P1 P2 P1 P2 AC Unit IntesisBox DK-RC-MBS-1 EIA485 A+ B- For wall mount extract the upper and lower staples until you hear the "click". 90 mm Max. 500 m MODBUS RTU EIA485 Bus 53 mm AC Indoor Unit Internal electronic control P1 P2 Max. 500 m Connection to P1 P2 bus. Two wires cable. Figure 2.1 DK-RC-MBS-1 Connection diagrams P1 P2 AC Unit IntesisBox DK-RC-MBS-1 EIA485 A+ B- MODBUS RTU EIA485 Bus 5 / 17

3. Modbus Interface Specification 3.1 Modbus physical layer DK-RC-MBS-1 implements a MODBUS RTU (slave) interface, to be connected to an RS-485 line. It performs 8N2 (8N1-compatible) communication (8 data bits, no parity and 2 stop bit) with several available baudrates (2400 bps, 9600 bps -default-, 19200 bps and 57600 bps). 3.2 Modbus Registers All registers are of type 16-bit signed Holding Register, in standard ModBus big endian notation. The registers are accessible as Holding registers or Input Registers 3.2.1 Control and status registers Register Addr (protocol address) Register Addr (PLC address) R/W 0 1 R/W 1 2 R/W 2 3 R/W 3 4 R/W 4 5 R/W 5 6 R 6 7 R/W Description AC unit On/Off 0: Off 1: On AC unit Mode 1 0: Auto 1: Heat 2: Dry 3: Fan 4: Cool AC unit Fan Speed 1 1: Low 2: Mid 3: High AC unit Vane Position 1 1: POS1 (Horizontal) 2: POS2 (Horizontal) 3: POS3 (Med) 4: POS4 (Vert) 5: POS5 (Vert) 10: SWING AC unit Temperature Setpoint 2,3 16..32ºC (ºC/x10ºC) 60..90ºF See section 3.2.3 below. AC unit Return Path Temperature 2, 3 (ºC/x10ºC/F) 2 See section 3.2.3 below. Window Contact 0: Closed 1: Open 1 See Section 5 for detail on indoor unit model differences and function availability 2 Magnitude for this register can be adjusted to Celsius x 1ºC, Celsius x 10ºC (default) or Fahrenheit through DIP switches S4 3 Check Table 3.4 for details 6 / 17

Register Addr (protocol address) Register Addr (PLC address) R/W Description 7 8 -- Reserved 8 9 R/W 9 10 R/W 10 11 R 11 12 R 22 23 R/W Remote Command Disablement 3 0: Remote Command enabled 1: Remote Command disabled AC unit Operation Time 4 0..65535 (hours). Counts the time the AC unit is in On state. AC unit Alarm Status 0: No alarm condition 1: Alarm condition Error Code Information in section 6 Indoor unit ambient temperature from external sensor (at Modbus side) -32768: Default value. No temperature is being provided from an external sensor. Any other: (ºC/x10ºC/ºF) 5 See section 3.2.3 below. 3.2.2 Configuration Registers Register Addr (protocol address) Register Addr (PLC address) R/W Description 12 13 R/W Reserved 13 14 R/W 14 15 R 15 16 R 21 22 R 49 50 R Open Window switch-off timeout 6,4 0..30 (minutes) Factory setting: 30 (minutes) Modbus RTU baud-rate (bps) 2400 4800 9600 19200 Device's Modbus slave address 1..63 Max number of fan speeds 7 2 3 Device Identification DK-RC-MBS-1: 0x800 50 51 R Software version 4 This value is stored in non-volatile memory 5 Magnitude for this register can be adjusted to Celsius x 1ºC, Celsius x 10ºC (default) or Fahrenheit through DIP switches S4 6 Once window contact is open, a count-down to switch off the AC Unit will start from this configured value 7 Configured with S1 (Table 3.1) 7 / 17

3.2.3 Considerations on DK-RC-MBS-1 temperature registers DK-RC-MBS-1 implements three registers containing temperature values: AC unit Temperature Setpoint (R/W) (register 5 in PLC addressing): This is the adjustable temperature setpoint meant to be required by the user. This register can be read (Modbus function 3 or 4) or written (Modbus functions 5 or 16). A remote controller connected to the P1P2 bus of the Daikin indoor unit will report the same temperature setpoint value as this register. AC unit return path temperature (R) (register 6 in PLC addressing): This register always shows the temperature reported by the sensor placed in the return path temperature of the Daikin indoor unit. It is a read-only register (Modbus functions 3 or 4). AC unit external reference temperature (R/W) (register 23 in PLC addressing): This register allows providing an external temperature reference from Modbus side. If an external temperature is provided through this register, indoor unit will use it as reference for its temperature control loop. o o o o For this temperature to take effect it is required that the Daikin AC indoor unit is configured in such a way that it uses the thermostat sensor in the remote controller (this is, DK-RC-MBS-1 will act as thermostat sensor providing a temperature sensor reading). This configuration is done via a Daikin remote controller connected to the indoor unit (Config mode 10 first code value 2 second code value 1 ) and must be done by Daikin authorized installers at the time of the installation of the AC. The value of this register only takes effect when DK-RC-MBS-1 is set as master of P1P2 bus, with respect to an additional remote controller in the bus (see section 2.1 - Connection of the interface to the AC indoor unit and 3.3 - DIP-switch Configuration Interface ) Register value after DK-RC-MBS-1 startup is -32768, which means that no temperature reference is provided to the AC indoor unit. In that case, AC indoor unit will use its own return path temperature sensor as reference for its control loop. Additionally, note that temperature values all these three registers are expressed according to the temperature format configured through its onboard DIP- (See 3.3 - DIP-switch Configuration Interface ). Following formats are possible: Celsius value: Value in Modbus register is the temperature value in Celsius (i.e. a value 22 in the Modbus register must be interpreted as 22ºC) Decicelsius value: Value in Modbus register is the temperature value in decicelsius (i.e. a value 220 in the Modbus register must be interpreted as 22.0ºC) Fahrenheit value: Value in Modbus register is the temperature value in Fahrenheit (i.e. a value 72 in the Modbus register must be interpreted as 72ºF (~22ºC). 8 / 17

3.3 DIP-switch Configuration Interface In this section the values of the configuration switches and their meaning are specified: L1 L2 S1 ON 1 2 3 4 P1 P2 AC Unit IntesisBox DK-RC-MBS-1 EIA485 A+ B- ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 S3 S4 Figure 3.1 DK-RC-MBS S1 AC unit configuration: Master/Slave, Master/Slave of Operating Mode, Fan speeds and Vanes Binary value b 0 b 4 Decimal value 1 2 3 4 Description 0xxx 0 x x x 1xxx 1 x x x Slave A Daikin BRC Controller must be present in P1 P2, configured as Master (default value). Master in P1 P2 bus Daikin BRC Controller not needed in P1 P2. If existing, BRC must be configured as slave x0xx 0 x x x Master of VRV Operation Mode (For VRV only) 8 x1xx 1 x x x VRV slave of Operating Mode (For VRV only) (default value) xx0x 0 x x x Indoor unit has 2 Fan Speeds (default value) xx1x 1 x x x Indoor unit has 3 fan speeds xxx0 0 x x x Indoor unit has no Vanes xxx1 1 x x x Indoor unit has Vanes (default value) Table 3.1 S1 switch configuration 8 Explained in section 7 9 / 17

S3 Modbus protocol: Slave address and baudrate Add Add Add Add 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 0 x x 16 x x 32 x x 48 x x 1 * x x 17 x x 33 x x 49 x x 2 x x 18 x x 34 x x 50 x x 3 x x 19 x x 35 x x 51 x x 4 x x 20 x x 36 x x 52 x x 5 x x 21 x x 37 x x 53 x x 6 x x 22 x x 38 x x 54 x x 7 x x 23 x x 39 x x 55 x x 8 x x 24 x x 40 x x 56 x x 9 x x 25 x x 41 x x 57 x x 10 x x 26 x x 42 x x 58 x x 11 x x 27 x x 43 x x 59 x x 12 x x 28 x x 44 x x 60 x x 13 x x 29 x x 45 x x 61 x x 14 x x 30 x x 46 x x 62 x x 15 x x 31 x x 47 x x 63 x x Table 3.2 S3 Modbus Slave address Binary value b 0 b 8 Decimal value 1 2 3 4 5 6 7 8 Description xxxxxx00 0 x x x x x x 2400bps xxxxxx10 1 x x x x x x 4800bps xxxxxx01 2 x x x x x x 9600bps (default value) xxxxxx11 3 x x x x x x 19200bps Table 3.3 S3 Modbus baud rate S4 Other: Degrees/Decidegress (x10), temperature magnitude (ºC/ºF) and EIA485 termination resistor Binary value b 0 b 4 Decimal value 1 2 3 4 Description 0xxx 0 x x x Temperature values in Modbus register are represented in degrees (x1) (default value) 1xxx 1 x x x Temperature values in Modbus register are represented in decidegrees (x10) x0xx 0 x x x x1xx 1 x x x Temperature values in Modbus register are represented in Celsius degrees (default value) Temperature values in Modbus register are represented in Fahrenheit degrees (value for S4-1 (x1/x10) is ignored) xxx0 0 x x x EIA485 bus without termination resistor (default value) xxx1 1 x x x Internal termination resistor of 120Ω connected to EIA485 bus ** Table 3.4 S4: Temperature and termination configuration * Default value ** Only in the interfaces connected at both ends of the bus must be activated the termination resistor, not in the rest. 10 / 17

3.4 Implemented Functions DK-RC-MBS-1 implements the following standard MODBUS functions: 3: Read Holding Registers 4: Read Input Registers 6: Write Single Register 16: Write Multiple Registers (Although this function is allowed, the interface does not allow write operations on more than 1 register with the same request, this means that length field should always be 1 when using this function for writes) 3.5 Device LED indicator The device includes two LED indicators (check Figure 3.1) to signal its different possible operational states. In this section their meaning is explained L1 (yellow) Operation ON OFF Meaning Blinking 500 ms 500 ms Communication error Flashing 100 ms 1900 ms Normal operation (configured and working) L2 (red) Operation ON OFF Meaning Pulse 3 sec -- Undervoltage L1 (yellow) & L2 (red) Operation ON OFF Meaning Pulse 5 sec -- Device start-up Alternate blinking 500 ms 500 ms Flash checksum not OK 3.6 RS485 bus. Termination resistors and Fail Safe Biasing mechanism RS485 bus requires a 120Ω terminator resistor at each end of the bus to avoid signal reflections. The DK-RC-MBS-1 device includes an on-board terminator resistor of 120Ω that can be connected to the RS485 bus by using DIP-switch (Table 3.4) A fail safe biasing circuit has also been included in the board of DK-RC-MBS-1, it can be connected to the RS485 bus by placing the internal jumper JP1(see details in Figure 3.2). This fail safe biasing of the RS485 bus must only be supplied by one of the devices connected to the bus Some Modbus RTU RS485 master devices can provide also internal 120Ω terminator resistor and/or fail safe biasing (consult the technical documentation of the master device connected to the RS485 network in every case). 11 / 17

Location of jumpers and DIP-switches for RS485 bus Termination resistor or Fail Safe Biasing selection: ON 1 2 3 4 JP1 1 Jumpers placed Fail safe biasing circuit connected to the RS485 bus ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 (jumper placed) Figure 3.2 Fail Safe jumper To access to internal jumpers JP2 and JP3, extract the top cover of the interface inserting a small screw-driver or clip in P1 P2 AC Unit the holes located at both sides of the cover. IntesisBox DK-RC-MBS-1 ON 1 2 3 4 EIA485 A+ B- ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 Figure 3.3 Accessing the jumpers 12 / 17

4. Specifications Dimensions: 93 x 53 x 58 mm Weight: 85 g Operating Temperature: -40... 85ºC Stock Temperature: -40... 85ºC Operating Humidity: <95% RH, non-condensing Stock Humidity: <95% RH, non-condensing Isolation voltage: 1000 VDC Isolation resistance: 1000 MΩ Modbus Media: Compatible with Modbus RTU - RS485 networks AC Unit connection LED Indicator DIP DIP 58 mm RS485 Port 53 mm 93 mm 5. List of supported AC Unit Types. A list of Daikin indoor unit model references compatible with DK-RC-MBS-1 and their available features can be found in: /pdf/intesisbox_dk-rc-xxx-1_ac_compatibility.pdf 13 / 17

6. Error Codes Error Code Modbus Error in Remote Controller Error category Error Description 0 N/A No active error 17 A0 External protection devices activated 18 A1 Indoor unit PCB assembly failure 19 A2 Interlock error for fan 20 A3 Drain level system error 21 A4 Temperature of heat exchanger (1) error 22 A5 Temperature of heat exchanger (2) error 23 A6 Fan motor locked, overload, over current 24 A7 Swing flap motor error 25 A8 Overcurrent of AC input 26 A9 Electronic expansion valve drive error 27 AA Heater overheat 28 AH Dust collector error / No-maintenance filter error 30 AJ Capacity setting error (indoor) 31 AE Shortage of water supply 32 AF Indoor Unit Malfunctions of a humidifier system (water leaking) 33 C0 Malfunctions in a sensor system 36 C3 Sensor system of drain water error 37 C4 Heat exchanger (1) (Liquid pipe) thermistor system error 38 C5 Heat exchanger (1) (Gas pipe) thermistor system error 39 C6 Sensor system error of fan motor locked, overload 40 C7 Sensor system of swing flag motor error 41 C8 Sensor system of over-current of AC input 42 C9 Suction air thermistor error 43 CA Discharge air thermistor system error 44 CH Contamination sensor error 45 CC Humidity sensor error 46 CJ Remote control thermistor error 47 CE Radiation sensor error 48 CF High pressure switch sensor 49 E0 Protection devices activated 50 E1 Outdoor uni9t PCB assembly failure 52 E3 High pressure switch (HPS) activated 53 E4 Low pressure switch (LPS) activated 54 E5 Overload of inverter compressor motor 55 E6 Over current of STD compressor motor 56 E7 Overload of fan motor / Over current of fan motor 57 E8 Over current of AC input 58 E9 Electronic expansion valve drive error 59 EA Four-way valve error 60 EH Pump motor over current 61 EC Water temperature abnormal 62 EJ (Site installed) Protection device activated 63 EE Malfunctions in a drain water 64 EF Ice thermal storage unit error 65 H0 Malfunctions in a sensor system 66 H1 Air temperature thermistor error 67 H2 Sensor system of power supply error 68 H3 High Pressure switch is faulty 69 H4 Low pressure switch is faulty 70 H5 Outdoor Unit Compressor motor overload sensor is abnormal 71 H6 Compressor motor over current sensor is abnormal 72 H7 Overload or over current sensor of fan motor is abnormal 73 H8 Sensor system of over-current of AC input 74 H9 Outdoor air thermistor system error 75 HA Discharge air thermistor system error 76 HH Pump motor sensor system of over current is abnormal 77 HC Water temperature sensor system error 79 HE Sensor system of drain water is abnormal 80 HF Ice thermal storage unit error (alarm) 81 F0 No.1 and No.2 common protection device operates. 82 F1 No.1 protection device operates. 83 F2 No.2 protection device operates 84 F3 Discharge pipe temperature is abnormal 87 F6 Temperature of heat exchanger(1) abnormal 91 FA Discharge pressure abnormal 92 FH Oil temperature is abnormally high 93 FC Suction pressure abnormal 95 FE Oil pressure abnormal 96 FF Oil level abnormal 97 J0 Sensor system error of refrigerant temperature 14 / 17

98 J1 Pressure sensor error 99 J2 Current sensor error 100 J3 Discharge pipe thermistor system error 101 J4 Low pressure equivalent saturated temperature sensor system error 102 J5 Suction pipe thermistor system error 103 J6 Heat exchanger(1) thermistor system error 104 J7 Heat exchanger(2) thermistor system error 105 J8 Oil equalizer pipe or liquid pipe thermistor system error 106 J9 Double tube heat exchanger outlet or gas pipe thermistor system error 107 JA Discharge pipe pressure sensor error 108 JH Oil temperature sensor error 109 JC Suction pipe pressure sensor error 111 JE Oil pressure sensor error 112 JF Oil level sensor error 113 L0 Inverter system error 116 L3 Temperature rise in a switch box 117 L4 Radiation fin (power transistor) temperature is too high 118 L5 Compressor motor grounded or short circuit, inverter PCB fault 119 L6 Compressor motor grounded or short circuit, inverter PCB fault 120 L7 Over current of all inputs 121 L8 Compressor over current, compressor motor wire cut 122 L9 Stall prevention error (start-up error) Compressor locked, etc. 123 LA Power transistor error 125 LC Communication error between inverter and outdoor control unit 129 P0 Shortage of refrigerant (thermal storage unit) 130 P1 Power voltage imbalance, open phase 132 P3 Sensor error of temperature rise in a switch box 133 P4 Radiation fin temperature sensor error 134 P5 DC current sensor system error 135 P6 AC or DC output current sensor system error 136 P7 Total input current sensor error 142 PJ Capacity setting error (outdoor) 145 U0 Low pressure drop due to insufficient refrigerant or electronic expansion valve error, etc. 146 U1 Reverse phase, Open phase 147 U2 Power voltage failure / Instantaneous power failure 148 U3 Failure to carry out check operation, transmission error 149 U4 Communication error between indoor unit and outdoor unit, communication error between outdoor unit and BS unit 150 U5 Communication error between remote control and indoor unit / Remote control board failure or setting error for remote control 151 U6 Communication error between indoor units 152 U7 Communication error between outdoor units / Communication error between outdoor unit and ice thermal storage unit 153 U8 System Communication error between main and sub remote controllers (sub remote control error) / Combination error of other indoor unit / remote control in the same system (model) 154 U9 Communication error between other indoor unit and outdoor unit in the same system / Communication error between other BS unit and indoor/outdoor unit 155 UA Combination error of indoor/bs/outdoor unit (model, quantity, etc.), setting error of spare parts PCB when replaced 156 UH Improper connection of transmission wiring between outdoor and outdoor unit outside control adaptor 157 UC Centralized address duplicated 158 UJ Attached equipment transmission error 159 UE Communication error between indoor unit and centralized control device 160 UF Failure to carrey out check operation Indoor-outdoor, outdoor-outdoor communication error, etc. 209 60 All system error 210 61 PC board error 211 62 Ozone density abnormal 212 63 Contamination sensor error 213 64 Indoor air thermistor system error 214 65 Outdoor air thermistor system error 217 68 HVU error (Ventiair dust-collecting unit) 219 6A Dumper system error 220 6H Door switch error 221 6C Replace the humidity element 222 6J Replace the high efficiency filter 223 6E Replace the deodorization catalyst Others 224 6F Simplified remote controller error 226 51 Fan motor of supply air over current or overload 227 52 Fan motor of return air over current / Fan motor of return air overload 228 53 Inverter system error (supply air side) 229 54 Inverter system error (return air side) 241 40 Humidifying valve error 242 41 Chilled water valve error 243 42 Hot water valve error 244 43 Heat exchanger of chilled water error 245 44 Heat exchanger of hot water error 258 31 The humidity sensor of return air sensor 259 32 Outdoor air humidity sensor error 15 / 17

260 33 Supply air temperature sensor error 261 34 Return air temperature sensor error 262 35 Outdoor air temperature sensor error 263 36 Remote controller temperature sensor error 267 3A Water leakage sensor 1 error 268 3H Water leakage sensor 2 error 269 3C Dew condensation error 339 M2 Centralized remote controller PCB error 345 M8 Communication error between centralized remote control devices 347 MA Centralized remote control devices inappropriate combination 349 MC Centralized remote controller address setting error 65535 N/A DK-RC-MBS-1 Error in the communication of DK-RC-MBS-1 device with the AC unit In case you detect an error code not listed, contact your nearest Daikin technical support service. 16 / 17

7. Annex 1: Master of Mode The master of mode only applies under the following conditions: 1. The AC system is VRV 2. The VRV system uses a Heat pump outdoor unit 3. The DK-RC-MBS-1 is configured as Master of the P1/P2 bus (Table 3.1) If they are not matched the parameter is going to be ignored. The Heat pump outdoor unit of a VRV system can only work in one mode (either Heat, Cool or fan). The Master of mode is the indoor unit that defines which is the working mode of the outdoor unit. If there is no Master of mode in the system the first AC unit to be turned On is the one controlling the mode. In a VRV system there can only be one device acting as Master of Mode. If more than one is configured this way the system is not going to work properly. When a DK-RC-MBS-1 is configured as Master of Mode it can control all the modes of the system (section 3.2.1). The Mode selection of all the other gateways and remote controllers is going to be affected by the one chosen by the Master of Mode (detailed in Table 7.1) Master of Mode Heat Dry Fan Cool Slave of Mode Heat, Fan Cool, Fan, Dry Fan Cool, Fan, Dry Table 7.1 Mode correspondence 17 / 17