Nokeval. FD100 series. User Manual

Similar documents
60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

H704-42(H)(E), H704-42/1(H)(E)

TBX-1316 High-Voltage Attenuator Terminal Block

S66 Series Electronic Fan Speed Control

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English

Safety switches with separate actuator

Installation Manual BAK02


PowerLogic High Density Metering System 1-Meter Enclosure

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

User's Guide. Model W 3-in-1 Switching DC Power Supply

Mini Digital Multimeter

Safety switches with manual mechanical delay and separate actuator

WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Rhino PSM Power Supplies. Operating Instructions

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Electrical Specifications


The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Product and functional description

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Pop-Up Floor Number(s) : à à à

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Rack Mount Power Supplies

Pop-Up Number(s) : to 03, to 08, to 13,

Product and functional description

Nokeval. No Manual. Models 575F, 1000F, 1100F, Scalable counter for pulse sensors

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Safety switches for hinged doors

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BCM2 Series Branch Circuit Monitors Quick Setup Guide

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

IF-80x Outdoor Terminal

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Version 5 Controls for natural ventilation. WUF 110 / 121 / 150 Actuator interfaces

ABB Junction boxes Top solutions for surface mounting

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

RТTH DUAL ROOM SWITCH

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Mini Digital Multimeter

Universal Safety Photo Eye UL MONITORED DEVICE

Access Terminal IF-800

INTELLIGENT SERVER. Model: BMS-LSV6E

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Safety switches with separate actuator

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Total Reach ISDN/DDS Isolation Card P P30059 Isolation Card

Redundancy Module QUINT-DIODE/40

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

TPE 1464 Series Pressure Transducer

Earth Resistance and Resistivity Tester

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

TOA INTERCOM SYSTEM TELEPHONE LINE INTERFACE

MX1 Reversible AC Motor Controller. Supplementary Wiring Examples

FP-PS-4. Features. Installation

RTD-W Installation Instructions

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

Conveyor Belt Alignment Switches from IDEM

RXTP ROOM TEMPERATURE

Power Supply (48Vdc, 2.5A)

AL168 Series Multi-Output Power Supplies

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

Installing the DX LCD Display

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Actionneur électrique Electric actuator Elektrische Stellantrieb Actuador eléctrico

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from

Temperature. Power requirements. Weight. Dimensions

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

LIFEBUOY RELEASE SYSTEM - TECHNICAL PRODUCT SPECIFICATION AND INSTALLATION MANUAL

Manual Control Unit GFC 32

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

APS4 Inductive Proximity Sensors

Double-deck terminal block; Through/through terminal block; L/L; gray housing

RXTH DUAL ROOM SENSOR / SWITCH

Transcription:

Nokeval FD100 series User Manual

Contents Document information... 2 FD100A4 and FD100A6 field displays... 3 Power supply connection... 4 Configuring... 5 Specifications... 7 Document information Device Scope: FD100A4 (4-digit device) FD100A6 (6-digit device) Case versions: 1.0 to 1.0 Document Type: manual Document ID: 3103 Document Version: 6 Document Date: 22.12.2011 2

FD100A4 and FD100A6 field displays Introduction The FD100 series includes 4 and 6 digit models. Digit size is 100mm. The displays are based on input cards of the panel meter series 2000 giving over 100 combinations. The unit has wide power supply range of 41...265 VAC or 20...28 VAC/VDC depending on model. This manual covers enclosure information and installation of the unit. Input cards and programming are covered in corresponding 2000-series panel meter manual. All 2000-series panel meter combinations are valid for this series. Mounting 503 (685) 450 (632) Lock for door on sides 100 145 191 477, (659) Ø7 mm notch Dimensions for FD100A6 (6digits) Two cable glands Ø13.5 mm hole are shown in brackets M20x1.5 mm The display unit can be mounted with four screws, one at each corner. The diameter of the screw must be between 5.5 and 6.5 mm. The unit may be mounted to a steel or aluminum structure, to wood with minimum thickness of 20 mm, or to a material of equivalent or better strength. To open the case door There are quick locks on the both sides of the case. The door can be unlocked by turning side locks towards the rear of the case. Warning! Only a qualified electrician is allowed to open the enclosure. 3

Symbols and markings Protective earth connector Alternating or direct current Power supply connection The unit has wide power supply range of 41...265 VAC or 20...28 VAC/VDC depending on model. There are two types of power supply connectors; grey connector color is used to indicate higher voltages and green color to indicate 24 V. FD100A4-F48/230 and FD100A6-F48/230 D3 Electronics unit D2 D1 N L Power supply 41...265 VAC Small display and buttons for configuration PE - Protective earth. Free wire length must be longer than on N and L lines Do not strip the wires more than necessary in order to avoid exposing dangerous voltages. Tie the N and L wires so that if one of them gets accidentally disconnected, the wire end can't reach the other connectors. 4

FD100A4-F24 and FD100A6-F24 Electronics unit D3 D2 D1 24V Power supply 20...28 VAC/VDC No polarity Small display and buttons for configuration Two cable glands Configuring The display unit is configured with the small display and buttons inside the main case. Electronics unit To reach electronics unit open the main case as explained before. Use the small display and four buttons to configure the display unit. Programming and input/output connections are explained in 2000-series panel meter manual for each different device type. Electronics unit Power supply (Factory connected) SLOT C SLOT B SLOT A See corresponding 2000-series panel meter manual for input and output connections Buttons and display. Programming is explained in corresponding 2000- series panel meter manual. 5

Jumper configurations If corresponding 2000-series manual informs that jumpers need to be changed, see below instructions to reach the jumpers. 1. Detach all connectors 2. Open these 4 screws to open the electronics case lid to reach internal measurement cards 6

Specifications Enclosure Indoors installation Allowed Dimensions See page 3 Outdoors installation Allowed Protection IP65 Altitude Max 2000 m Pollution degree 3 Operating temperature -10 +50 C Weight, 4 digits 5 kg Storage temperature -30 +50 C Weight, 6 digits 6 kg Humidity < 90 %Rh Power supply Nominal voltage 20 28 VAC / VDC or 41 285 VAC depending on model Pre-fuse (not required) >2 AT (24V), not required >1 AT (230V), not required Frequency 45 65 Hz Installation category CAT II Power <50 VA Protection Enclosure: Class 1, protective earth. Inputs: Class 2, reinforced insulation. Regulations Electrical safety EN 61010-1 Classification Fixed equipment, permanently connected equipment, with protective earth See additional input and output card specifications from corresponding 2000-series manual. Nokeval Nokeval Oy, Yrittäjäkatu 12, 37100 Nokia, Finland, Tel. +358 3424800, fax. +358 3422066, sales@nokeval.com, www.nokeval.com 7