Fiber optic Switch. eol 1x2 1x4 2x2. eol 1x8 1x12 1x16 OPERATION MANUAL

Similar documents
Fiber Optic Prism Switch USER S MANUAL

LT900SERIES. 1xN Multi-Channel Switch Operation Manual

LATCHING FIBER OPTIC 1xN SWITCHES

LT900SERIES. 1xN Multi-Channel Switch Operation Manual. For RS-232 Control with 16-pin Connector

FIBER OPTIC 1xN SWITCH coaxial design

LightBend TM Dual 2x2 Bypass Multimode Fiberoptic Switch

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

FIBER OPTIC TRANSMITTING MODULE TOTX147(F,T)

SBU35020DRxx SFP Single Upstream Transceiver Tx 1310nm & Rx 1550nm / 20km / Dual Rate

Strain Gage Measuring Amplifier GSV-3

SFCxx100PAxD SFP Dual fibre CWDM ITU CWDM / 100km / OC-48 Multirate.

Low Voltage, 10-Bit Digital Temperature Sensor in 8-Lead MSOP AD7314

LD6015. Datasheet & Manual. 1. Features. 3. Description. 2. Applications. 4. Absolute maximum ratings* 5. Recommended operating conditions

850nm Optical Video Dual Receiver

VDL-004. Miniature Manual Variable Optical Delay Line. User Guide

Optical Switch

RoHS COMPLIANT 2002/95/EC

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

WM1030 Rev Introduction. Ultra low power DASH7 Modem. Applications. Description. 868 / 915 MHz. Features. WIZZILAB Technical datasheet 1/10

TORX176 TORX176 FIBER OPTIC RECEIVING MODULE FOR DIGITAL AUDIO EQUIPMENT. 1. Maximum Ratings (Ta = 25 C) 2. Recommended Operating Conditions

Craft Port Tiny RS-232 Transceiver for Portable Applications ADM101E. Data Sheet FUNCTIONAL BLOCK DIAGRAM

SH1030 Rev Introduction. Ultra low power DASH7 Arduino Shield Modem. Applications. Description. 868 MHz. Features

User Manual for TeraRanger Evo single point distance sensors and backboards

Manual Fiber Optic Interfaces

Page 1 of 11 Version 1.2 Release Date: PenMount PM2204 PCI Controller Board Data Sheet. Table of contents

QFBR-S01IN001Z. Optical Phase Interrogator. Data Sheet. Description. Features. Applications

User Manual for TeraRanger Evo single point distance sensors and backboards

Preliminary Data MOS IC. Type Ordering Code Package SDA Q67100-H5096 P-DIP-8-1

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany.

Data Sheet. QFBR-S01IN001Z Optical Phase Interrogator. Description. Features. Applications

Page 1 of 13 Version 1.5 Release Date: PenMount PM1410 PCI Controller Board Data Sheet. Table of contents

User Manual for TeraRanger Evo with: USB and I2C/UART backboard

Fixed mount CCD bar code reader NFT Specification Ver. 1.0

Manual DTM Digital Pressure Transmitter

User Manual for. TeraRanger Evo with: USB and I2C/UART backboard

Preliminary Data MOS IC. Type Ordering Code Package SDA Q67100-H5092 P-DIP-8-1

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

Precise Fiber Couple Laser Light Source

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

WBI Series Mass flow sensors for gases

General Specifications. P2-SCM Serial Communications

Markus Hintermann Global Technical Marketing / Sales Manager at Micro Crystal

600 mw Fiber Bragg Grating Stabilized 14xx nm Pump Modules with Ultra-Low Power Consumption. S35 Series

GLC-GE-100FX (100BASE-FX SFP) Datasheet

(threaded M5) 7-pole fem. connector Binder Series 712 (connection Master/Slave) Connecting cable: cab-las7-male not necessary for single system!

Turnkey Tabletop CW Laser Drive Module Part #LN-WLxx-RIN-Pxx

SLD Drive SLD. Board FC/APC Connector. TEC Control. Board. Control Circuits. Control interface DB9 (Female)

GFK-2415A March Type of sensor connection

RoHS COMPLIANT 2002/95/EC

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

TORX111 TORX111 FIBER OPTIC RECEIVING MODULE FOR APF. 1. Maximum Ratings (Ta = 25 C) FIBER OPTIC RECEIVING MODULE.

Accessories / 7XV5662

1999PLU. Active Components Pump Laser Modules. Key Features. Applications. For more Info

APPLICATION NOTE DD-100

PCD 005 PolaMIX. Operation Manual

SYSTEMS ELECTRONICS GROUP

TORX177(F,T) TORX177(F,T) TENTATIVE FIBER OPTIC RECEIVING MODULE FOR DIGITAL AUDIO INTERFACE. 1. Maximum Ratings (Ta = 25 C)

Up to 200 mw Uncooled 980 nm Pump Modules. TO T13 Series

XFCxx070100D XFP CWDM Dual Fibre Transceiver ITU CWDM / 70km / 10 Gigabit Ethernet

976nm Laser Module Stabilized with Narrow-Bandwidth Grating

Amphenol Advanced Sensors. SM-UART-04L Laser Dust Sensor. Application Note. Features. Applications

Evaluation Board User Guide UG-047

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)

P3-SCM. General Specifications

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

PSW-002. Fiber Optic Polarization Switch. User Guide

RT209 OEM Scan Engine. RT209 Integration Guide. Integration Guide

Specification. Small Form Factor Pluggable Dual Transmitter (Non-MSA) LC Receptacle SFP+ 12 Gigabit SDI TIN-A1C61-F14

TORX147(F,T) TORX147(F,T) FIBER OPTIC RECEIVING MODULE FOR DIGITAL AUDIO INTERFACE. 1. Absolute Maximum Ratings (Ta = 25 C) 2.

B5W-LD0101-1/2 B5W- L D Air Quality Sensor. Highly Sensitive and Compact Air Quality Sensor. Model Number Structure. Ordering Information

TORX178B TORX178B FIBER OPTIC RECEIVING MODULE FOR DIGITAL AUDIO INTERFACE. 1. Maximum Ratings (Ta = 25 C) FIBER OPTIC RECEIVING MODULE

T A S A 1 E H

Mounting possibilities (threaded M5)

Master Oscillator Power Amplifier SLD System MOPA-SLD-850

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

QFPQL010400D QSFP+ Dual Fibre CWDM ITU CWDM / 10km / 40 Gigabit Ethernet / LR-4

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany.

Model 3955 DFB 1550nm Laser in TO-can

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Technical data. General specifications. Indicators/operating means

OPTOSTAR's OP-MDCX8xxL1SD-40 10G Cooled EML XFP DWDM transceivers are designed for 10G

L-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope)

Mounting. possibilities. Transmitter optics. 8-pole fem. connector Binder Series 712 (PLC) Connecting cable: cab-las8/sps or cab-las8/sps-w

Product Data Sheet. 3M Active Optical Cable (AOC) Assemblies for CX4 and QSFP+ Applications

L-LAS Series. L-LAS-TB-F-6x1-40/40-CL L-LAS-TB-F-1x6-40/40-CL. Design. L-LAS Series Laser Line Sensors. Product name:

Serial Data DIN Fiber Link System

Switch Protection Module

The Wireless Connectivity Expert

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

PureGain PG1600P. Data Sheet. Fixed Gain, Compact EDFA with Digital Control Electronics. Contents: Features:

F3EM Measuring lightcurtain in robust aluminium housing

Electrically tunable large aperture lens EL TC-VIS-20D

Stereo PDM-to-I 2 S or TDM Conversion IC ADAU7002

Parameter Symbol Min. Typical Max. Unit Storage Temperature T S C Supply Voltage V CC T, R V Relative Humidity RH 0 85 %

PRELIMINARY! DIGITAL HUMIDITY SENSOR

6100E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Transcription:

Fiber optic Switch eol 1x2 1x4 2x2 eol 1x8 1x12 1x16 OPERATION MANUAL

CONTENTS Product Specification Features / Applications / Technology. 3 Optical Characteristics. 4 Electrical & Environmental Characteristics. 4 Performance Curves. 5 Switch Operation Pin Configuration. 6 Serial Interface. 9 Parallel Interface. 10 I 2 C Interface. 12 Device Housing / Mounting. 14 Handling Instructions Handling of Fibers 15 Cleaning & Mating of Connectors 15 Any information established by manufacturer is believed to be accurate and reliable. However, no responsibility is assumed by manufacturer for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of manufacturer.

FEATURES excellent repeatability ultra low back reflection low insertion loss and PDL high optical isolation broad spectral range polarization maintaining option short switching time small dimensions APPLICATIONS testing and measurement fiber optic sensing add/ drop multiplex system network fault protection signal protection laser scanning microscopy fiber bragg sensors multi channel optical power monitoring TECHNOLOGY eol series switches were developed to serve for the most demanding applications in testing and measurement. Its optomechanical design (MOEMS) ensures an excellent optical performance combined with short switching time due to refractive microoptical components and industry proofed high resonant actuators. The small package size and unilateral fiber location simplify the switch accomodation on printed circuit boards. The implemented microcontroller provides versatility in interface programming and controlling. FUNCTIONAL BLOCK DIAGRAM

OPTICAL CHARACTERISTICS parameter unit test conditions / comments insertion loss 0.7 db typ. 1.0 db max. @ 1.55µm and 1,31µm 1.4 db max. @ 0.80µm and 0,65µm 2.0 db max @ 0.46µm 0.60 µm back reflection <-65 db @ 1,55µm crosstalk <-55 db repeatabiltiy 0.005 db standard wavelength range 400 670 nm 600...850 nm 900 1200 nm 1260-1360 1480-1650 nm 5000 cycles @ 1Hz, constant temperature other wavelengths on request polarization depending loss < 0.1 db switching time switching frequency 2 50 ms Hz max. reliability > 10 8 cycles power consumption < 300 mw ELECTRICAL CHARACTERISTICS parameter unit test conditions / comments operating voltage 5 V switching current 50 ma min. switching frequency = 0Hz 100 ma typ. 300 ma max. switching frequency = 50Hz ENVIRONMENTAL CHARACTERISTICS parameter unit test conditions/comments storage temperature -40 to +80 C operating temperature 0 to +60 C vibration stability Up to 10 g no influence on optical characteristics

PERFORMANCE CURVES REPEATABILITY 0,003 0,002 0,001 0-0,001-0,002-0,003 0 100 200 300 400 500 600 700 800 SWITCHING CHARACTERISTICS THERMAL CHARACTERISTICS INSERTION LOSS (db) 0,15 0,05 0 15 30 45 60-0,05-0,15 TEMPERATURE ( C)

PIN CONFIGURATION 1x2; 2x2; 1x4 # PIN PIN name type *) function test 1 V CC P positive voltage 5V 2 GND P ground, (reference point for interfaces) 3 TxD O transmitter data output of serial port 4 RxD I receiver data input of serial port 5 SDA I/O I 2 C-compatible input/output pin 6 SCL I/O serial clock pin for I 2 C interface 7 - not used never connect this pin to GND or V cc 8 D0 I address bit 0 for the TTL/parallel interface 9 D1 I address bit 1 for the TTL/parallel interface 10 strobe I clock pin for parallel interface *) notes: P power supply I input O output I/O input and output simultaneously

PIN CONFIGURATION 1x8; 1x12; 1x16 # PIN PIN name type *) function test 1 V CC P positive voltage 5V 2 GND P ground, (reference point for interfaces) 3 TxD O transmitter data output of serial port 4 RxD I receiver data input of serial port 5 SDA I/O I 2 C-compatible input/output pin 6 SCL I/O serial clock pin for I 2 C interface 7 - not used never connect this pin to GND or V cc 8 D0 I address bit 0 for the TTL/parallel interface 9 D1 I address bit 1 for the TTL/parallel interface 10 D2 I address bit 2 for the TTL/parallel interface 11 D3 I Address bit 3 for the TTL/parallel interface 12 strobe I clock pin for parallel interface *) notes: P power supply I input O output I/O input and output simultaneously

SERIAL INTERFACE The RS232 interface allows to control the switch from your PC or laptop directly. The interface is protected for short circuits by GND. SPECIFICATIONS - T out = ±9V (typ.) - R in = ±25V (max.) - RS232 input threshold low = 1.3V (typ.) - RS232 input threshold high = 1.8V(typ.) SETTINGS - 57600 Baud (standard) - 8 data bit - no parity - 1 stop bit CABLE CONNECTIONS eol 1x4 - pin code Computer DB-9 pin Computer DB-25 pin 2 GND 5 7 3 TxD 2 3 4 RxD 3 2 COMMANDS All commands must be sent in ASCII code. A command is not executed until terminated by a carriage return (ASCII decimal code 13) and a new line (ASCII decimal code 10). COMMAND SUMMARY command name parameter response function type? none eol1x4 1 response of the switch type firmware? none ver3.27 response of the firmware version number ch? none 2 indicates the current switch position ch 1.. 4 2 none sets into the specified position example: ch3 -> enables channel 3 i2c? Actual i2c adress Response for the set i2c adress i2c 10 99 Setting the i2c adress Note: 1 response for eol1x2: eol 1x2 and for eol 2x2: eol 2x2 2 for the eol1x2 and eol2x2 switch use 1 and 2

Parallel Interface - Switch can only receive data, not transmit - Switch can be programmed either with or without a chipselection signal (strobe) - Interface operates with standard TTL levels (see LEONI Manual) - Case1: without strobe After detecting a new switching state (binary code) at the data input port, the switches moves to the corresponding channel after time delay t 1. In order to avoid problems this code must be kept constant for this period. t 1 > 40µsek - Case 2: with Strobe (standard interface operation) By a HIGH LOW slope, data at the parallel interface ports are transferred into the switch and stored there (latch). The LOW level for the strobe input must be constant for a time period t 1. Before the HIGH LOW slope the strobe signal has to be at HIGH level at least for a time duration t 2. Switching occures after a duration t 3. t 1 t 2 t 3 >45µsek >45µsek t 1 +20µsek

Please note: After each switching process the switch will not accept signals for the next 6 ms. Other values are possible on costumers request. (See the following table for the necessary binary code corresponding to the required switch channels. Please note that data pins D3 and D2 are not used for switch configurations 1x2; 2x2; 1x4). D3 D2 D1 D0 Channel 0 0 0 0 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 4 0 1 0 0 5 0 1 0 1 6 0 1 1 0 7 0 1 1 1 8 1 0 0 0 9 1 0 0 1 10 1 0 1 0 11 1 0 1 1 12 1 1 0 0 13 1 1 0 1 14 1 1 1 0 15 1 1 1 1 16

- Fiber switch operates as Slave - Interface corresponds to PhilipsSpecs standard mode (see Philips-Homepage) o Deviations from standard: - Switch does not respond to the common adress 0000000b - (this is even not a stringent requirement) - switch does not support a 10Bit adressing - Switch can only receive data, not transmit - In correspondence to the specifications of the standard mode only bitrates up to 100kBit are accepted. Higher bitrates will lead to noncorrect function of the switch. - After a switching operation is initiated through an interface (also valid for parallel interface and RS232) it will be blocked for a 20 ms period in order to avoid overload of the high-voltage electronics (this is also valid for parallel and RS232) - The following figure (taken from the Philips Dokumentation) shows the typical Timing for the I²C-Bus: Adress: 68 (1000.100 + 0b) Data byte: for channel 1: 0000.0001b for channel 2: 0000.0010b for channel 3: 0000.0011b... for channel 12 : 0000.1100b The initial adress (set at works) is 68. This initial adress can be changed by an appropriate command through the RS232 interface. For this purpose additional to the existing commands of the RS232 interface: o ch? o ch o firmware? o type?

Two additional commands have been added for the support of the I2C interface: o i2c? this allows to query the actual I2C adress o i2c this allows to set the I2C adress to any fixed value between 10 and 99 (for example i2c15 sets the adress 15 After a new adress has been set, it remains unchanged even after switch off the power supply, as this adress is stored in the flash memory of the controller. Important: Please write the commands in small letters!! The commands must be activated by a carriage return!!

DEVICE HOUSING (small) DEVICE HOUSING (large)

Handling Instructions for Fiberoptic Components CAUTION! Any extreme stresses onto the optical cable could degrade the optical performance or damage the fiber. Do not pull on the fibers! Never bend an optical cable more sharply than a 35mm radius! Bending over any sharp edges may damage or break the fiber! Avoid excessive heat near cables! All optical connectors should remain covered with dust cups in place when not in use. Cleaning & Mating Instructions for Optical Connectors Clean both connectors prior to mating by using a high-grade isopropyl alcohol and a cotton swab. Allow connectors have to dry before mating. Insert the connector ferrule into the appropriate adapter smoothly. Do not over-tighten the connectors. Specifications for the eol series switches are based on an optimal connection. If the resulting values are unacceptable, please repeat the cleaning procedure and start again.