Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Similar documents
Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

Features: DS54 v1.0 DIN rail mounted switch 5-port DS54 for 4 IP cameras without power supply

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

Features: Example of use

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from

PSBOC PSBOC 27,6V/5,5A/OC

PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3

EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

PSBEN 2012B v.1.1/vii PSBEN 13,8V/2A/7Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN/LCD buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

PSBEN 3012C. PSBEN 13,8V/3A/17Ah/EN Buffer, switched mode power supply unit.

PSBEN 10A12E. PSBEN 13,8V/10A/65Ah/EN Buffer, switch mode power supply unit Grade 3.

EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems

v.1.1/iv EN54 27,6V/7A/2x40Ah power supply for fire alarm systems

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

Buffer power supply units. compliant with EN are intended to alarm system devices

PSBEN 5012D/LCD. PSBEN 13,8V/5A/40Ah/EN/LCD Buffer, switched mode power supply unit.

Buffered Power Supply PS-30DR v1.0

PSBEN 2012B/LCD. PSBEN 13,8V/2A/7Ah/EN/LCD Buffer, switched mode power supply unit.

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

EN54-2A17. EN54 27,6V/2A/2x17Ah power supply for fire alarm systems

Industrial PoE Media Converter

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Hardened PoE Ethernet Switch

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

RXTP ROOM TEMPERATURE

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Installation Manual for D244X Series 24-volt Power Supplies

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Expandable Power Systems

Switches & Power over Ethernet

Interface RS485-WiFi

2 in 1 LAN Tester and Multimeter Model:

OPERATION AND MAINTENANCE MANUAL

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

POWER SUPPLY SYSTEM DSO 24V FOR PAVIRO SYSTEM BY BOSCH

RXTH DUAL ROOM SENSOR / SWITCH

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

ETHOS Auto Ranging Digital Multimeter

CF-POE4 4-Port Gigabit + 2GE Uplink PoE Switch

MCX402DR-BRD I/O expander. Operating Manual

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

DC Outdoor Power Supply/Chargers

PTC-101-M12 Hardware Installation Guide

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Artistic Licence. Mica. User Guide. Mica User Guide. Version 1-1

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Mini Digital Multimeter

Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual

User Manual. cmt-svr Startup Guide

5-Port 10/100TX with 4 PoE Injector Industrial Switch

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Language of the manual

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Mini Digital Multimeter

PTC-101 Quick Installation Guide

IGLOO IGLOO EASY INSTRUCTION MANUAL

Switched Mode Power Supply Operating manual PAP800

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

SWITCH, 24 POE PORTS ART. IPSWP240A

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

THOR Battery Backed DC Power Supply Reference Manual

OPERATING INSTRUCTION

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Model : ON-PS3016G. 16 Port 10/100/1000Mbps Gigabit + 2 Gigabit SFP Uplink Unmanaged PoE Switch

ST-POE-2P-WTP. IP67-Rated POE Extender

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Safety Standards. Model Number:

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Autoranging True RMS Multimeter User Manual

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Model HM-535 Power Supply Installation and Service Instructions

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Modular 8-Port Mid-span Power over Ethernet Injector

Rugged MediaConverter

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Industrial IEEE a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features

Transcription:

S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras (48V DC) 9 10/100 Mb/s ports 8 PoE ports (data transfer and power supply) 15,4W for each PoE port, supports devices complaint with the IEEE802.3af standard Approximate backup time: 6h Metal enclosure color white RAL 9003 with battery space for two batteries 17Ah/12V Supports auto-learning and auto-aging of MAC addresses (1K size) warranty 2 year from the production date Example of use. CONTENTS 1. Technical description. 1.1 General description 1.2 Block diagram 1.3 Description of components and connectors 1.4 Technical parameters 2. Installation. 2.1 Requirements 2.2 Installation procedure 3. Indication of the device operation 3.1 LED indication of operating status 3.2 Optical indication of the switch operation 4. Operation and use. 4.1 Overload or short circuit of the PSU output (SCP on) 4.2 Disconnection of discharged battery 4.3 Maintenance 1

1. Technical description 1.1. General description. The S98-B is dedicated for uninterruptible power supply of 8 IP cameras (48V DC power supply). The main elements of this system include: - 9 port PoE switch - 27,6V buffer power supply unit which can accommodate two 2 x 17Ah / 12V - a converter (DC/DC48250) increasing the voltage to 48V DC (supply of the PoE switch) In case of power decay, a battery back-up is activated immediately. The approximate backup time is given assuming that all output ports are used (using typical devices and 17Ah batteries). The electricity consumption for own needs and the energy efficiency of the power intake track were taken into account. The exact description of how to perform the calculations can be found at: "Approximate backup time - assumptions for calculations". Automatic detection of any devices powered in the PoE standard is enabled at the 1 8 ports of the switch. The UPLINK port is used for connection of another network device e.g. recorder. The LEDs at the front panel indicate the operation status (description in the table. 8). The switch is housed in a metal enclosure (color RAL 9003) which can accommodate two 2x17Ah/12V battery. The enclosure features a micro switch tamper indicating door opening (front panel). The S98-B is fitted with two LEDs on the front panel (red LED indicates 230V AC power supply of the PSU, green LED indicates the presence of DC voltage). The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate power cable for each device. This method allows supplying other network devices, such as IP phone, wireless access point or router. 1.2 Block diagram. Fig. 1. Block diagram. 2

1.3 Description of components and connectors. Fig. 2. The enclosure view. Table 1. (See Fig. 2) Component No. (Fig. 2) Description [1] Switch PoE [2] Switch mode buffer power supply unit [3] DC/DC48250 converter [4] Output filter [5] Tamper micro switch (terminals) of tamper protection (NC) [6] Space for two batteries 17Ah/12V [7] Power supply connector of the PSU L, N PE protective connector (electric shock) [8] BAT +, BAT - battery output + BAT red, - BAT black Fig. 3. The view of the switch. 3

Table 2. (See Fig.3) Component No (Fig. 3) [1] 8 x PoE port (1 8) [2] 1 x UPLINK port [3] 48V DC power supply socket Description 1.4 Technical parameters - parameters of the switch (tab.3) - electrical parameters (tab.4) - mechanical parameters (tab.5) - operation safety (tab.6) - operating parameters (tab.7) Table 3. Parameters of the switch Ports PoE power supply Protocols, Standards Forwarding rate Bandwidth Transmission method 9 10/100 Mb/s ports (8 x PoE + 1 x UPLINK) with connection speed auto-negotiation and MDI/MDIX Auto Cross) IEEE 802.3af (1 8 ports), 48V DC / 15,4W at each port * Used pairs 4/5 (+), 7/8 (-) IEEE802.3, 802.3u, 802.3x CSMA/CD, TCP/IP 10BASE-T: 14880pps/port 100BASE-TX: 148800pps/port 1,6 Gbps Store-and-Forward Switch power supply; Optical indication of Link/Act; operation PoE Status * The given value of 15.4W per port is the maximum value. The total power consumption should not exceed 96W when all PoE ports are being used. Table 4. Electrical parameters Mains supply 176 264V AC Current up to 1,4A@230V AC max. Supply power 110W Output current at the PoE ports (RJ45) 8 x 0,3A ΣI=2A (max.) Output voltage at the PoE ports (RJ45) 48V DC Short-circuit protection SCP and overload protection OLP 105% 150% PSU power, manual restart (the fault requires disconnection of the DC output circuit) PSU current consumption 100mA Battery charge current 0,5A max. / 2x17Ah (+/-5%) Approximate backup time 6h Battery circuit protection SCP and reverse polarity connection melting fuse Deep discharge battery protection UVP U<19V (± 5%) disconnect of connection battery Sabotage protection: - TAMPER output indicating enclosure opening - microswitch, NC contacts (enclosure closed), 0,5A@50V DC (max.) 4

Table 5. Mechanical parameters Dimensions W=397, H=350, D+D 1=92+8 [+/- 2mm] W 1=402, H 1=355 [+/- 2mm] The dimensions of the battery 370 x 180 x 80mm (WxHxD) max compartment Gross/Net weight 4,8 / 5 kg Enclosure Steel plate, DC01 1,0mm color white RAL 9003 Closing Cheese head screw x 2 (at the front), (lock assembly possible) Power supply of the cameras: RJ45 socket Connectors Outputs: Φ 0,63-2,50 (AWG 22-10), battery output BAT: 6,3F-2,5 TAMPER output: wires Notes The enclosure does not touch the assembly surface so that cables can be led. Table 6. Operation safety Protection class PN-EN 609501:2007 I (first) Protection grade PN-EN 60529: 2002 (U) IP20 Electrical strength of insulation: - between input and output circuits of the PSU (I/P-O/P) 3000 V/AC min. - between input circuit and PE protection circuit (I/P-FG) 1500 V/AC min. - between output circuit and PE protection circuit (O/P-FG) 500 V/AC min. Insulation resistance: - between input circuit and output or protection circuit 100 MΩ, 500V/DC Declarations CE Table 7. Operating parameters Operating temperature Storage temperature Relative humidity Vibrations during operation Impulse waves during operation Direct insulation Vibrations and impulse waves during transport -10ºC...+40ºC -20ºC...+60ºC 20%...90%, without condensation unacceptable unacceptable unacceptable According to PN-83/T-42106 2. Installation 2.1. Installation procedure The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V AC and low-voltage installations. The device shall be mounted in confined spaces, according to the environment class II, with normal air humidity (RH=90% max. without condensation) and the temperature from -10 C to +40 C. The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the enclosure. Before installation, prepare a Switch'a load balance. The given value of 15,4W per port is the maximum value referring to a single output. The total power consumption should not exceed 96W when all PoE ports are being used. The increased demand for power is particularly evident in the case of cameras with heaters or infrared illuminators - when launching these features, the power consumption increases rapidly, which may adversely affect the operation of the switch. As the device is designed for a continuous operation and is not equipped with a power-switch, therefore an appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed about the method of unplugging (usually through assigning an appropriate fuse in the fuse-box). The electrical system shall follow valid standards and regulations. 2.2. Installation procedure 1. Before installation, cut off the voltage in the 230V power-supply circuit. 2. Mount the PSU in a selected location and connect the wires. 3. Connect the power cables (~230V AC) to L-N clips of the PSU. The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire coat of the power cable shall stick to one side of the terminal - marked with symbol on the PSU enclosure. Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE! It can cause a device failure or an electric shock. 5

4. Connect the ground wire to the terminal marked with the symbol (power supply module connector). Connect the ground wire to the clip marked by the earth symbol PE. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. Lead the cables to the appropriate clips through the insulating bushing of the connection board. 5. Connect the power (~230V). 6. Connect the battery (mind the colours): - battery output (+V): BAT+ cable / red, - battery output (0V): BAT cable / GND / black. 7. Connect the camera cables to the RJ45 connectors (PoE connectors) and connect the recorder to the network (the UPLINK connector). 8. Check the optical indication of the switch operation. 9. After installing and checking proper working, the enclosure can be closed. 3. Indication of the device operation. 3.1 LED indication of operating status. The PSU is equipped with two diodes on the front panel: RED LED: on the PSU is supplied with 230V AC off no 230V AC supply GREEN LED: on DC voltage in the AUX output of the PSU off no DC voltage in the AUX output of the PSU 3.2 Optical indication of the switch operation (see Table 8). Table 8. Indication of the switch operation OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY GREEN LED LIGHT (Power) Indication of the switch's power supply OFF no power supply of the switch ON power supply on, normal operation OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY (1 8) DIODA LED ZIELONA (PoE) Indication of the PoE power supply at the RJ45 ports YELLOW LED LIGHT (LINK) The connection status of LAN devices, 10 Mb/s or 100 Mb/s and data transmission OFF- no power supply at the RJ45 port (the device is not connected or not compliant with the IEEE802.3af standard) ON supply at the RJ45 port Blinking short-circuit or output overload OFF- no connection ON - the device is connected; 10 Mb/s or 100 Mb/s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT GREEN LED LIGHT OFF- no connection ON the device is connected; 10 Mb/s or 100 Mb/s YELLOW LED LIGHT (LINK) The connection status of LAN devices, 10 Mb/s or 100 Mb/s and data transmission OFF- no data transmission ON - the device is connected: 10 Mb/s or 100 Mb/s Blinking data transmission 6

Installation example of the S98-B battery (Battery not included) 4. Operation and use. 4.1 Overload or short circuit of the PSU output (SCP on). In case of overload, the output voltage is automatically shut off, and so is the LED indicator. The restoration of the voltage takes place immediately after the failure (overload) is over. 4.2 Disconnection of discharged battery. The PSU is equipped with the discharged battery disconnection system. During the battery-assisted operation, reducing voltage below 19V at the battery terminals will cause battery disconnection. 4.3 Maintenance. Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network. The PSU does not require performing any specific maintenance measures, however, in case of significant dust rate, its interior is recommended to be cleaned with compressed air. In case of fuse replacement, use a replacement of the same parameters. 7

WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the applicable law. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl 8