BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

Similar documents
BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

BVS 16 ATEX E088 X, IECEx BVS X. Operating Instructions

Type Quickstart

Type Quickstart (from device Version 2)

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

SolConeX extra-low voltage flange socket

Type ME43. Quickstart

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

MINI MCR-SL-CVS NC

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

PI-EX-ME-2NAM/COC-24VDC

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

MANUAL Surge Protectors

SUBCON-PLUS-PROFIB...

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Metal Position Switch

Safety instructions Overvoltage protection B81-35

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

SolConeX Wall-Mounted Socket, 16 A

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

MINI MCR-SL-MUX-V8-FLK 16

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

GRP Flameproof Visual Signal Xenon or Steady LED

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Type 8791 Positioner SideControl BASIC. Quickstart. English / Deutsch / Français

Technical Data. Dimensions

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Digital electropneumatic positioner SideControl

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

MACX MCR-EX-SD LP(-SP)

PHOENIX CONTACT - 02/2008

MANUAL LML-P, LML-S, LML-Ex

Safety Instructions Cerabar S PMP71, PMP75

MINI MCR-SL-PT100-UI-200

Technical Data. General specifications. Rated operating distance s n 3 mm

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Pneumatic Control/Feedback

SMARTLINE RM76 Supplementary instructions

ETD-BL-1T-OFF-CC- 10S

Pneumatic Control/Feedback

PHOENIX CONTACT - 05/2007

FLEX Ex Spring Clamp Terminal Base

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Series 3730 Type Electropneumatic Positioner

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Micro Motion, Inc. Page 1 of 6

Series 3730 Type Electropneumatic Positioner

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Operating instructions

DR7100 SERIES Supplementary instructions

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Product manual plug, sockets and coupler 16 A.- Z0251

Digital electropneumatic Positioner SideControl

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

PHOENIX CONTACT - 01/2008

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Refer to attachment for more details. Andreas Meyer

Control Head for the integrated mounting on process valves

Installation manual plugs and connectors with screw connection (16/32 A)

Type Operating Instructions - Software. Bedienungsanleitung - Software Manuel d utilisation - Logiciel

Inductive sensor BI1.5-EG08-Y1-H1341

Installation Instruction. HART Add-On Module

Intrinsically safe batch controller Batching Master 110i

Type MS04. Redox potential sensor cube. Operating Instructions

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Inductive sensor NI3-EG08K-Y1-H1341

Digital electropneumatic Positioner for the integrated mounting on process control valves

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Quick Start Guide MHM CC-PBF-EN, Rev 1 April Emerson A0701PBU. Emerson 701P SmartPower Module - Blue

Smart Wireless THUM Adapter

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

Replacing Spare Parts

CPCI-PS24 24V-Power Supply

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Installation & Operation Manual

Type Flow Transmitter / Pulse divider Durchflusstransmitter / Impulsteiler Transmetteur de débit / Diviseur d impulsions

Control Head. Quickstart. English

Inductive sensor BI1.5-EG08-Y1-H1341

Transcription:

/ IECEx BVS 16.0091 X Types 8791, 8792, 8793 Position controller and process controller with II 3G Ex ec ic IIC T4 Gc / II 3D Ex tc IIIC T135 C Dc approval Stellungsregler und Prozessregler mit Zulassung II 3G Ex ec ic IIC T4 Gc / II 3D Ex tc IIIC T135 C Dc Régulateur de position et régulateur de process avec homologation II 3G Ex ec ic IIC T4 Gc / II 3D Ex tc IIIC T135 C Dc Additional Instructions Zusatzanleitung Instruction supplémentaire

We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Bürkert Werke GmbH & Co. KG, 2010-2017 Operating Instructions 1703/02_EU-ml_00809480 / Original DE

Contents 1 ADDITIONAL INSTRUCTIONS...4 1.1 Definitions of terms... 4 2 SYMBOLS...4 3 AUTHORIZED USE...5 4 PARTICULAR SAFETY INSTRUCTIONS...5 4.1 Special conditions of use... 6 5 INSTRUCTIONS ON OPERATION IN THE EXPLOSION-RISK AREA...7 5.1 Media in the explosion-risk area... 7 5.2 Actuators / valves in the explosion-risk area... 7 5.3 Cleaning in the explosion-risk area... 7 5.4 Adhesive labels for the explosion-risk area... 7 5.5 Ambient temperature in the explosion-risk area... 8 5.6 Grounding the housing... 9 5.7 Installing sheet metal cover and housing cover... 9 5.8 Explosion protection approval...10 3

Additional instructions 1 ADDITIONAL INSTRUCTIONS The additional instructions contain safety instructions and information for the use of the device in the explosion-risk area. Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device. Important safety information. Read these instructions carefully and thoroughly. Study in particular the chapters entitled Particular safety instructions and Authorized use. The additional instructions must be read and understood. Further information on the device can be found in the operating instructions of the corresponding device. The operating instructions can be found on the Internet at: www.burkert.com 1.1 Definitions of terms The term "device" used in these instructions always stands for the position controllers Type 8791 and Type 8792 and for the process controller Type 8793. 2 SYMBOLS The following symbols are used in these instructions. DANGER! Warns of an immediate danger! Failure to observe the warning will result in a fatal or serious injury. WARNING! Warns of a potentially dangerous situation! Failure to observe the warning may result in a serious or fatal injury. CAUTION! Warns of a possible danger! Failure to observe this warning may result in a moderate or minor injury. NOTE! Warns of damage to property. Important tips and recommendations. Refers to information in these operating instructions or in other documentation. designates instructions for risk prevention. designates a procedure which you must carry out. 4

Authorized use 3 AUTHORIZED USE Non-authorized use of the device may be dangerous to people, nearby equipment and the environment. The device is designed to be mounted on pneumatic lifting and rotary actuators for the control and regulation of media. Type 8791 to 8793 PX45 is approved according to device group II category 3G/D for use in explosion-risk areas of Zones 2 and 22. The complete identification is located on the type label (see chapter "5.4"). The device is mounted on a pneumatic lifting or rotary actuator. In doing so, the control valve must have at least explosion protection approval of the position/process controller. During use observe the permitted data, the operating conditions and conditions of use specified in the contract documents, the operating instructions and on the type label - of the position/process controller and - the control valve. Use the device only in conjunction with third-party devices and components recommended and authorized by Bürkert. Correct transportation, storage and installation as well as careful operation and maintenance are essential for reliable and fault-free operation. Use the device only for its intended purpose. 4 PARTICULAR SAFETY INSTRUCTIONS DANGER! Risk of explosion when removing the electric circular plug. Secure cable connections, which use circular plugs, with suitable locking clips. This will prevent the circular plug from working loose. For example: EXCLIP, FA. Phoenix Contact, Type SAC-M12-EXCLIP-M, art. no. 1558988 or Type SAC-M12-EXCLIP-F, art. no. 1558991 or locking clips, FA. ESCHA Locking clip M8 x 1, art. no. 8040691 Locking clip M12 x 1, art. no. 8040501. Do not remove or connect electric circular plug until the power supply has been disconnected. Risk of explosion when opening the device. Open device only when no explosive atmosphere is present. Risk of explosion caused by electrostatic discharge. In the event of a sudden discharge from electrostatically charged devices or individuals, there is a risk of explosion in the explosionrisk area. Protect device from large charge-generating processes. Ground housing before start-up. Take suitable measures to ensure that no electrostatic discharges can build up in the explosion-risk area. Clean the device surface by gently wiping it with a damp or antistatic cloth only. 5

Particular safety instructions DANGER! To prevent the risk of explosion, observe not only the safety instructions in the operating instructions for operation in the explosion-risk area, but also the following: Specifications on the type label concerning temperature class, ambient temperature, degree of protection and voltage. Do not use device in areas where there is gas or dust with a lower ignition temperature than indicated on the type label. Installation, operation and maintenance may be performed by qualified technicians only. Observe the applicable safety regulations (also national safety regulations) as well as the general rules of technology for construction and operation. Do not repair the device yourself, but replace it with an equivalent device. Repairs may be performed by the manufacturer only. Do not expose the device to any mechanical and/or thermal loads which will exceed the limits described in the operating instructions. Use only cable and line entry points which have been approved for the respective application area and which have been screwed into place according to the associated installation instructions. The cable glands may be used for the insertion of permanently installed cables and lines only. Close all unnecessary cable glands with lock screws approved for the explosions area. Use pre-assembled cable glands according to the installation instructions supplied by the gland manufacturer. Before start-up in the explosion-risk area, check whether the cable gland, as described in the associated installation instructions, has been installed. 4.1 Special conditions of use Do not use the device in dust atmospheres in which intensive charging processes can be expected. Use the device only in an area with at least degree of soiling 2, as defined in IEC 60994-1. Ensure that the transient protection has been set to a value which does not exceed 140 % of the measured peak voltage value at the supply connections of the device. If devices feature a circular plug connection (multipole), the mating plug will be provided by the end user and is not an object of the approval. The mating plug must satisfy the relevant requirements of the IEC 60079-0, IEC 60079-7 and IEC 60079-31 and must have at least housing degree of protection IP65 according to IEC 60529. If devices feature a circular plug connection (multipole), use a special locking clip which prevents the plug from being loosened without a tool. 6

Instructions on operation in the explosion-risk area 5 INSTRUCTIONS ON OPERATION IN THE EXPLOSION-RISK AREA When using the device in an explosion-risk area, observe the following: 5.1 Media in the explosion-risk area If explosive media are used, this can result in additional explosion risks. 5.2 Actuators / valves in the explosion-risk area Use in an explosive atmosphere may be restricted by the actuators / valves. Observe the operating instructions of the actuators / valves. 5.3 Cleaning in the explosion-risk area DANGER! 5.4 Adhesive labels for the explosion-risk area Fig. 1: WARNING 1. DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED 2. DO NOT OPEN WHEN ENERGIZED 3. POTENTIAL ELECTROSTATIC CHARGING HAZARD - see instructions Additional adhesive label Type label Arrangement of the adhesive labels for the explosion-risk area, additional adhesive label Risk of explosion caused by electrostatic charge. Clean the device surface by gently wiping it with a damp or antistatic cloth only. Check that cleaning agents are approved for use in explosive atmospheres. 7

Instructions on operation in the explosion-risk area 1 8 8792 24V DC 5W NAMUR Profibus DP P=1,4 7 bar IP65/67 Tamb 0..+60 C S/N 123456 00999999 7 W17MA BVS 16 ATEX E 118 X II 3G Ex ec ic IIC T4 Gc II 3D Ex tc IIIC T135 C Dc IECEx BVS 16.0091 X Ex ec ic IIC T4 Gc Ex tc IIIC T135 C Dc D-74653 Ingelfingen Identification of explosion protection: Gas Gas group II 3G Ex ec ic IIC T4 Gc II 3D Ex tc IIIC T135 C Dc Fig. 2: Dust 2 3 4 5 6 11 12 13 14 15 C 0102 Equipment protection level Temperature class Dust group Ignition protection type Type label (example) of a device with explosion protection approval US 9 10 16 Item Description 1 Manufacturer's logo 2 Type identification, nominal voltage, nominal power 3 Device design (NAMUR/Remote; 24V DC/Profibus DP/DeviceNet) 4 Nominal range of supply pressure and degree of protection 5 Ambient temperature range 6 Serial number 7 ID number 8 Ex Logo 9 CE logo with Notified Bodies 10 Other approval logos 11 Date of manufacture (encoded) 12 ATEX, certificate author and certificate number 13 ATEX, identification of the explosion protection 14 IECEx, certificate author and certificate number 15 IECEx, identification of the explosion protection 16 Barcode (includes identification number and serial number) Tab. 1: Description of the type label data 5.5 Ambient temperature in the explosion-risk area Types 8791, 8792, 8793 PX03: 0 +60 C 8

Instructions on operation in the explosion-risk area 5.6 Grounding the housing DANGER! Risk of explosion caused by electrostatic discharges. Ground housing before starting up the device. 5.7 Installing sheet metal cover and housing cover DANGER! Risk of explosion when opening the device. Open device only when no explosive atmosphere is present. Install electrical system only when no explosive atmosphere is present. Sheet metal cover Screw FE functional ground Fig. 3: Connection for grounding the housing Use a suitable cable lug for grounding. Spacer sleeve Housing cover Seal Fig. 4: Installing/removing sheet metal cover and housing cover using Type 8791 as an example 9

Instructions on operation in the explosion-risk area To install the electrical system using screw-type terminals and to start up Type 8791 using DIP switches, remove the sheet metal cover and the housing cover: Unscrew screws (4 x) on the housing cover. Remove sheet metal cover together with the screws and spacer sleeves. Remove housing cover and fold to the side. Install or start up device. After installing or starting up the device, mount sheet metal cover and housing cover: Close housing cover, ensuring that the seal is correctly fitted. Attach sheet metal cover with screws and spacer sleeves (see "Fig. 4"). Tighten screws (4 x) hand-tight as far as the stop. 5.8 Explosion protection approval The explosion protection approval is only valid if the modules and components authorized by Bürkert are used as described in these operating instructions. Use the devices only in combination with the valve types approved by Bürkert, otherwise the explosion protection approval will expire. If any unauthorized changes are made to the system, modules or components, the explosion protection approval will also expire. The EU Type-Examination Certificate BVS 16 ATEX E 118 X and IECEx BVS 16.0091 X was issued by DEKRA EXAM GmbH Dinnendahlstraße 9 D-44809 Bochum Germany Production is audited by the PTB (CE0102). 10