ETC Installation Guide

Similar documents
ETC Installation Guide

ETC Installation Guide

ETC Installation Guide

Unison Echo Room Controller

ETC Installation Manual

ETC Installation Guide

ETC Desire Quick Guide

ETC Quick Guide. Source Four LED Profile

Wireless Fixture Adapter (WFA100-SN) Installation Instructions

ColorSource ThruPower

DMX, 2 CHANNEL 2 Channel DMX Driver

Wall Mount, UL Installation Manual

ETC Desire Quick Guide

Push button to adjust displays. LCD Touchscreen Power Button. keypad Keyboard Tray

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

BCM2 Series Branch Circuit Monitors Quick Setup Guide

DIRECT POWER LIGHTING MANUAL

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module

Compact, Low Profile High Rendering, 100% Diffusion

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

INSTALLATION INSTRUCTIONS

PowerLogic High Density Metering System 1-Meter Enclosure

ZenNet Installation Guide:

ERDMX-E Install Guide

SCD96 DMX Output Interface. Installation guide

Loaner Unison CMEd Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS

ETC Setup Guide Universal Fader Wing Installation

SNAP Lighting Control Panel

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

AION LED WT SERIES. Custom Lengths. Made in the USA IP66* High Efficacy Exterior Rated Linear Fixture System

PM Series Power Meter

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Irideon FPZ. User Manual. Rev A

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

THE CTB08D LIGHT CONTOLLER

Wireless Adapter (WA100-PM) i. Installation Instructions

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

Satellite INSTALLATION GUIDE

Installation & Operation Guide

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

Digital Lighting Systems, Inc.

Wallstations for use with Grafik 3000 and 4000 Series Systems

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS

M250 (M LL) Safety

M215-Z Safety Information (M LL-IG-ZC)

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

SAVE THESE INSTRUCTIONS

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

User Manual. Revision B

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

EcoSystem to 0 10 V- Interface

Linearray PD Retrofit Kit

ERn Wall Mount Enclosure Installation Manual

PV Rapid Shutdown device

Switched Relay Controller - Relay Panel with Breakers

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Installation Instructions

Power Load Controller F series INSTALLATION GUIDE

R-LB R-LX Series Installation, Operation & Maintenance Manual

CS XL XM. EcoSystem Bus Supply

Operating instructions. Switching amplifier DN0210 DN / / 2015

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Loosen these screws 2 full turns Step 4: Carefully flip over the console and loosen the 3 screws in blue below: NOTE: DO NOT remove the 3 screws.

PROJECT INFORMATION FLANGE FINISH LENS S. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

A-TRACK HOUSING FAMILY. Semi-Custom. End to End Connectivity. Made in the USA. Custom Lengths. Semi-Custom to Meet Your Needs

ETM-2040 Service Manual

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

Energi Savr Node with DALI for Quantum

Installation and Operations Manual. Electronic copies available at (Rev_ )

Principal LED Qwik Stik Fluorescent Bulb Replacements

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

LCD Central Drive Remote Driver Pathway Custom Series

Wireless General Purpose Adapter (WGA100) Installation Instructions

M215 (M215-60) Safety

Distributed Power Series

Unison ERn Rack Mount Enclosure Installation Manual

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

INSTALLATION INSTRUCTIONS

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

Model DMX8DIM Installation and Operations Manual

PS/IO Circuit Board Retrofit

Operating instructions. Speed monitor D / / 2014

ETC Setup Guide arfr/ irfr for Eos Family Consoles

INSTEON SwitchLinc 1000W. INSTEON Dimmer Switch. For models: SwitchLinc V2 Dimmer 1000W

PX 227. DMX Demux 8. Manual

Installation Instructions

Installation Instructions for Rebel Chameleon TM 105XBRi Series LED Multi-Status Indicator in NEMA 4X Enclosures

Max. Input Power (W) Input Current. Inrush Current

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Transcription:

Unison Foundry Overview The Unison Foundry provides fully-rated 20A relays for switched power control with 0 10V dimming for compatible fluorescent ballasts and LED drivers. The provides two outputs of control that can be wired to individual fixtures or used for zone control. Each output can be configured to a separate DMX address, or both outputs can be controlled in unison by setting the to single-channel mode (see Channel Mode on page 8). Control connected loads from any DMX control device. Configure the 0 10V Controller either remotely via RDM (using a tool like ETC Net3 Concert) or locally on the controller. See Configure the on page 8. Specifications Ambient Environment For indoor use only. Rated for plenum use. 32 F to 104 F (0 C to 40 C) operating temperatures in 5 95% noncondensing humidity. Corporate Headquarters Middleton, Wisconsin, USA Tel +608 831 4116 Service (Americas) service@etcconnect.com London, UK Tel +44 (0)20 8896 1000 Service: (UK) service@etceurope.com Rome, IT Tel +39 (06) 32 111 683 Service: (UK) service@etceurope.com Holzkirchen, DE Tel +49 (80 24) 47 00-0 Service: (DE) techserv-hoki@etcconnect.com Hong Kong Tel +852 2799 1220 Service: (Asia) service@etcasia.com Web: etcconnect.com 2017 Electronic Theatre Controls, Inc. Product information and specifications subject to change. ETC intends this document to be provided in its entirety. 7179M2120 Rev B Released 2017-12

Electrical Specification The Supports: Power input 120 277VAC, 60 Hz Maximum load rating is 20A (total connected load) The maximum load on the can be split between the two relay outputs in any combination required for the installation, but cannot exceed 20A total connected load for the controller. Independent control for 0 10V fluorescent ballasts and/or LED drivers, each is capable of sinking 100mA Supported Load Types (all voltages): 20A fully-rated relay for use with general purpose, tungsten, fluorescent, and LED lighting loads. Compliance UL and cul listed Conforms to UL 916 (Energy Management Equipment) and UL 2043 (Plenum rated) Page 2 of 16 ETC

Prepare for Installation The is designed for mounting directly to an electrical junction box or panel (provided by others) at the electrical lighting load, upstream of the load in the circuit. If your installation requires Class 2 wiring to be installed in separate conduit, a voltage barrier installation box is available from ETC. Order ETC part number 7187A1000. DMX Control Wiring The connects to a DMX512-A source (provided by others) for control. DMX wiring runs can be daisy chains of up to 32 devices with no Y s or loops. Each DMX daisy chain must be terminated for proper control performance (see Terminate DMX on page 5). ETC recommends using Belden 9729 (or approved equivalent) Class 2 wire. Belden 1583A or equivalent Cat5, Cat5e, or Cat 6 UTP wire is also acceptable when properly shielded or installed in grounded metal conduit and connected using the Cat5 IDC termination kit (ETC part number 4100A1013). This termination kit is not provided with the. A voltage barrier installation box (part number 7187A1000) is available for installations where DMX control wiring is installed in grounded metal conduit. Contact ETC to purchase termination kits or voltage barrier installation boxes if required. The total combined length of a DMX wire run (using Belden 9729 or equivalent) may not exceed 1,000 ft (300 m). All control wiring should be installed and terminated by a qualified installer and should follow standard wiring installation practices. Leave approximately 10 in (255 mm) of wiring available for connection and to allow slack for future service needs. For more information on DMX control wiring requirements, see these and other Support Articles at etcconnect.com: etcconnect.com/support/articles/dmx-512-info.aspx etcconnect.com/support/articles/dmx-over-cat5.aspx Page 3 of 16 ETC

Installation Installation should follow all local codes and standard electrical practices. Ensure that the junction box is clean and free of obstructions and that all wiring is installed correctly. WARNING: Risk of electric shock! This device utilizes high voltage and should only be installed by a qualified installer or electrician. Follow all local codes for installation. Before terminating the AC power wiring verify that the main breaker is in the off position and follow the proper lockout/tag out procedures per NFPA Standard 70E. WARNING: For indoor use only! Must install to an electrical junction box or wire way. 1: Locate the circuit breaker panel and turn off the power to the lighting circuit. 2: To gain access to the line voltage wiring, remove the cover plate and other hardware from the junction box at the load. 3: Mount the to the exterior of the junction box or panel using the 1/2 threaded nipple. Use the provided 1/2 conduit locknut to secure the to the junction box or panel. Follow all local code requirements for terminating wire. Notice that the harness wires on the controller are pre-stripped for your installation convenience. Use appropriately sized wire nuts (not provided) to secure each termination. Page 4 of 16 ETC

Connect DMX 1: Pull wiring to the junction box. 2: Terminate the DMX cable by following the steps in the termination kit supplied with the unit. Terminate DMX Terminate the last device in the DMX data run for proper control performance. To terminate the DMX data run at the, connect the last two pins on the termination connector with a wire jumper (not included) as shown below. Because resistance is built into the, no additional resistor is required to terminate the last device in the DMX data run. Wire jumper Page 5 of 16 ETC

Connect Power Input and Relay Output The power input and relay output wiring exits the through the knockout mount on the enclosure. 1: Connect the power input wiring. a: Connect the white wire (14 AWG) to the incoming neutral wire from the breaker panel and the neutral wire of the lighting load. b: Connect the power input wire (12 AWG) to the line input feed wire (hot) from the breaker panel. Power input wire is black for 120VAC or brown for 277VAC. 2: Connect the relay output wiring. The has two relay output wires (18 AWG): Zone 1 is red and Zone 2 is red/white. a: Connect the Zone 1 relay output wire (red) to the hot input of the first load. b: Connect the Zone 2 relay output wire (red/white) to the hot input of the second load. When configured to single-channel mode, a single DMX address controls both relays. If you are using only one output, cap off the unused wires with wire nuts (not included). Gray 0 10V Violet Gray/White 0 10V Violet/White Dimming Ballast 1 Dimming Ballast 2 Black Line In White Neutral Red Red/White Load 1 Load 2 DMX-512A Page 6 of 16 ETC

Connect 0 10V Dimming Output WARNING: RISK OF DEATH OR INJURY BY ELECTRIC SHOCK! 0 10V wiring may not be fully isolated from high voltage AC power. Do not assume that 0 10V wiring is safe to touch, even when run as an NEC Class 2 signal. Test for AC voltage to ground before terminating any 0 10V control wiring to the. The 0 10V dimming output wiring exits the through the top nipple of the enclosure with the power wiring. 1: Connect the 0 10V dimming output wiring. The has two pairs of 0 10V output wires (22 AWG): Zone 1 is gray and violet, and Zone 2 is gray/white and violet/white. a: Connect the Zone 1 output wires, gray (+) and violet (-), to the control input of the connected load. b: Connect the Zone 2 output wires, gray/white (+) and violet/white (-), to the control input of the second connected load. 2: Reinstall the junction box cover plate. CAUTION: The 0 10V control outputs must be treated as NEC Class 1 control signals, in the same manner as other high voltage connections. Page 7 of 16 ETC

Configure the You can use RDM to set the DMX address and data loss behavior for the. You can set other parameters using RDM, too. See RDM Parameters on page 14. Channel Mode You can configure the to single-channel or dual-channel mode using Net3 Concert or another RDM controller. In dual-channel mode, each relay is assigned a separate DMX address for control. In single-channel mode, both relays are assigned to a single DMX address and function in unison. The ships from the factory in dual-channel mode. See RDM Parameters on page 14. You can also switch between single-channel mode and dual-channel mode using the SET button on the. Press and hold the SET button to switch modes. The POWER LED will blink once for single-channel mode or twice for dual-channel mode. DMX Address You can assign DMX addresses to an entire daisy chain of Unison Foundry devices using Net3 Concert or another RDM controller. If you cannot assign the DMX addresses using RDM, you can manually set the DMX start address on the device. The default factory-set DMX address is 1, and the range of available addresses is 1 512. Page 8 of 16 ETC

Manually Set the DMX Address If you cannot assign the DMX addresses using RDM, use the MODE and SET buttons to set the value of each digit in the three-digit DMX address in sequence. POWER LED SIGNAL LED SET button MODE button Task What to do What you will see 1: Put the controller into DMX addressing mode. 2: Set the 100s digit of the DMX address. 100s 10s 1s 201 Press and hold the MODE button. Press the SET button to set the 100s digit. For example, press the button once for 1, twice for 2, and so forth up to five times for 5. Press and hold the SET button for 0. If the 100s digit in the new DMX address is the same as in the current DMX address, you can keep the digit by skipping to step 3. The POWER LED indicator blinks 3 times to indicate that you can set the 100s digit of the DMX address. The SIGNAL LED indicator blinks the 100s digit in the current DMX address. For example, if the current DMX address is 201, the SIGNAL LED indicator blinks 2 times. (If the 100s digit is a 0, the indicator remains lit and does not blink.) The POWER LED indicator continues to blink 3 times to indicate that you are setting the 100s digit of the DMX address. The SIGNAL LED indicator blinks the value that you set for the 100s digit in the DMX address. Page 9 of 16 ETC

Task What to do What you will see 3: Set the 10s digit of the DMX address. 100s 10s 1s 201 Press the MODE button to advance to the 10s digit. Press the SET button to set the 10s digit. For example, press the button once for 1, twice for 2, and so forth up to nine times for 9. Press and hold the SET button for 0. If the 10s digit in the new DMX address is the same as in the current DMX address, you can keep the digit by skipping to step 4. The POWER LED indicator blinks 2 times to indicate that you are setting the 10s digit of the DMX address. The SIGNAL LED indicator blinks the 10s digit in the current DMX address. For example, if the current DMX address is 201, the SIGNAL LED indicator remains lit and does not blink. If the SIGNAL LED indicator rapidly blinks red, this means that you set the 100s digit to an invalid value (for example, 6). When this occurs, the exits DMX addressing mode without saving. The POWER LED indicator continues to blink 2 times to indicate that you are setting the 10s digit of the DMX address. The SIGNAL LED indicator blinks the value that you set for the 10s digit in the DMX address. Page 10 of 16 ETC

Task What to do What you will see 4: Set the 1s digit of the DMX address. 100s 10s 1s 201 5: Save the new DMX address. Press the MODE button to advance to the 1s digit. Press the SET button to set the 1s digit. If the 1s digit in the new DMX address is the same as in the current DMX address, you can keep the digit by skipping to step 5. Press the MODE button. The POWER LED indicator blinks once to indicate that you are setting the 1s digit of the DMX address. The SIGNAL LED indicator blinks the 1s digit in the current DMX address. For example, if the current DMX address is 201, the SIGNAL LED indicator blinks once. If the SIGNAL LED indicator rapidly blinks red, this means that you set the 10s digit to an invalid value. When this occurs, the exits DMX addressing mode without saving. The POWER LED indicator continues to blink once to indicate that you are setting the 1s digit of the DMX address. The SIGNAL LED indicator blinks the value that you set for the 1s digit in the DMX address. The POWER LED indicator and SIGNAL LED indicator return to their normal functions (see LED Indicators and User Interface on page 13). If the SIGNAL LED indicator rapidly blinks red, this means that you set the 1s digit to an invalid value. When this occurs, the exits DMX addressing mode without saving. The will exit DMX addressing mode after 1 minute of inactivity. When this occurs, the controller retains the DMX address that was saved before you entered DMX addressing mode. Page 11 of 16 ETC

Data Loss Behavior Use RDM to set the behavior of the when DMX is lost. The has three options for data loss behavior: Hold last look Wait and fade Go to full The Go to full data loss behavior does not meet the requirements of UL924 for emergency lighting control. Power Up and Test 1: Restore power to the circuit. The will power up and turn on all connected loads to full output. 2: Verify that DMX input is present. The green signal LED on the unit should be lit steadily. If it is blinking, check the DMX wiring. 3: Configure the controller. If additional configuration is required, use an RDM controller such as ETC Net3 Concert software to configure the appropriate properties. For more detailed information, see the Net3 Concert integrated help system. 4: Test the controller response. Use the DMX control system to alter the control level, and make sure the responds. Power-Up Behavior In the event of a power loss to the, the controller will return to its last output level when power is restored. Page 12 of 16 ETC

LED Indicators and User Interface POWER LED SIGNAL LED SET button MODE button LED Indicator Color State Description SIGNAL Green Update the Software You can update the software for the using ETC UpdaterAtor software and an ETC Gadget II or Gateway. Both LED indicators on the blink during software updates. Restore Defaults Solid Slow blinking DMX present, system OK. DMX absent. Verify that the DMX wiring is correct, and verify that the DMX source is functioning correctly. DMX errors. Verify that the DMX wiring is Rapid blinking correct, and verify that the DMX source is functioning correctly. POWER Blue Solid Power is OK. Return the to factory defaults by pressing and holding both the MODE and SET buttons simultaneously for 5 seconds. Both LEDs will blink rapidly to indicate that the factory defaults have been restored. For factory default values, see RDM Parameters on page 14. Page 13 of 16 ETC

RDM Parameters You can set the following RDM parameters on the using Net3 Concert or another RDM controller. Parameter ID and Number Description Default Value Device Label E120_DEVICE_LABEL 0x0082 User-configurable name for the device ETC DMX Dual Relay 0 10V DMX Start Address E120_DMX_START_ADDRESS 0x00F0 DMX address, range = 1 512 1 DMX Personality E120_DMX_PERSONALITY 0x00E0 Sets the channel mode: Dual-channel mode Single-channel mode Dual-channel mode DMX Fail Mode (Data Loss) E137_1_DMX_FAIL_MODE 0x0141 Configures the behavior when DMX is lost: Hold last look Wait and fade Go to full Go to full Packet Delay ETC_E120_PACKET_DELAY 0xB000 Requires any change of level to be present for at least this number of packets before action is taken (open/close the relay or change 0 10V output). Range = 0 50. 0 Page 14 of 16 ETC

Page 15 of 16 ETC

Page 16 of 16 ETC