Table of Contents Product Overview Before using the product Installation Procedure... 5

Similar documents
Installation, Operation and Maintenance Manual

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- RELAY OUTPUT FR-A5AR

FR-A8AR INSTRUCTION MANUAL

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Analog Monitor Installation Manual

Analog Input Installation Manual

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

INVERTER INSTRUCTION MANUAL. Relay output function. Plug-in option FR-A7AR PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT

INSTALLATION INSTRUCTIONS

VECTOR INVERTER -INSTRUCTION MANUAL- HIGH RESOLUTION ANALOG INPUT / EXTRA CONTACT INPUT / THERMISTOR INTERFACE FR-V5AX

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

PV Rapid Shutdown device

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

SMVector Additional I/O Module Installation and Operation Manual

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Installation Instructions

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

Model 2657A-LIM-3 LO Interconnect Module

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

INVERTER INSTRUCTION MANUAL. Analog output function Digital output function. Plug-in option FR-A7AY PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

ELV12 Series. Instruction Manual

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

Installation Instructions

The identified danger could cause physical and property damage.

Installation Job Aid for Ethernet Routing Switch 3600 Series

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

ICON SERIES ipool. Swimming Pool Pump Controller. User Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

OPLC Installation Guide

HV-CS kv Edge Mount Triaxial Jack

Checking the compatibility with IT (ungrounded) and corner-grounded delta systems. EMC filter +E200 (690 V drives and drive modules)

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

XTM1250SA DIN rail three phase four wire LCD display energy meter

PowerLogic ION7300 Series

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

SMVector Additional I/O Module Installation and Operation Manual

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

InnoMedia Business VoIP ATA Models

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

WARNING ELECTRICAL SHOCK HAZARD

HT2000 Transverter Installation & Operation Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Vision OPLC V TR6/V350-J-TR6

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

2260B-RMK-Series Rack Mount Kit

Additional Explanation for A851GOT Graphic Operation Terminal

MDM 011-Z1 Regen Resistor

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

User Manual. GUARD STATION(Gate View System) CDS-4GS

DC I/O Conversion Module FA-TB32XY

Leading LED Applications. XD6/XD10 User Manual

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

PRO-75 SERIES. User manual

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

PRO2DM DIN rail single phase two wire energy meter

Model VT120 Fast Timing Preamplifier Operating and Service Manual

POCKET MULTIMETER Model No: MM18

Optional add-on cassette Attachment Instruction manual

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

DarkFX Spot 670 User Manual English

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

Model GHz 50 Ohm RF Module

Magnetek Dynamic Braking Resistors

Chore-Tronics Mobile Server

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter

DC I/O Conversion Module

1395 Node Adapter Board Troubleshooting

ERNT-AQTX10 ERNT-AQT68AD-GH. User s Manual. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter.

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

YASKAWA AC Drive J1000

TOS-SN-1 Extended Panel Operation Manual

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Transcription:

Table of Contents Table of Contents... 1 1. Product Overview... 5 2. Before using the product... 5 3. Installation Procedure... 5 4. S100 Product Size (Drive with Option)... 14 5. H100 Product Size (Drive with Option)... 28 6. Dimensions & Screw... 34 7. Revision History... 35 1

Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS To prevent injury and property damage, follow these instructions. Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness of which is indicated by the following symbols. DANGER WARNING CAUTION This symbol indicates the instant death or serious injury if you don t follow instructions This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property The meaning of each symbol in this manual and on your equipment is as follows. This is the safety alert symbol. Read and follow instructions carefully to avoid dangerous situation. This symbol alerts the user to the presence of dangerous voltage inside the product that might cause harm or electric shock. After reading this manual, keep it in the place that the user always can find easily. This manual should be given to the person who actually uses the products and is responsible for their maintenance. 2

WARNING Do not remove the cover while power is applied or the unit is in operation. Otherwise, electric shock could occur. Do not run the inverter with the front cover removed. Otherwise, you may get an electric shock due to high voltage terminals or charged capacitor exposure. Do not remove the cover except for periodic inspections or wiring, even if the input power is not applied. Otherwise, you may access the charged circuits and get an electric shock. Wiring and periodic inspections should be performed at least 10 minutes after disconnecting the input power and after checking the DC link voltage is discharged with a meter (below DC 30V). Otherwise, you may get an electric shock. Operate switches with dry hands. Otherwise, you may get an electric shock. Do not use the cable when its insulation is damaged. Otherwise, you may get an electric shock. Do not subject the cables to scratches, excessive stress, heavy loads or pinching. Otherwise, you may get an electric shock. 3

CAUTION Install the inverter on a non-flammable surface. Do not place flammable material nearby. Otherwise, fire could occur. Disconnect the input power if the inverter gets damaged. Otherwise, it could result in a secondary accident and fire. Do not touch the inverter while the input power is applied or after removed. It will remain hot for a couple of minutes. Otherwise, you may get bodily injuries such as skin-burn or damage. Do not apply power to a damaged inverter or to an inverter with parts missing even if the installation is complete. Otherwise, electric shock could occur. Do not allow lint, paper, wood chips, dust, metallic chips or other foreign matter into the drive. Otherwise, fire or accident could occur. OPERATING PRECAUTIONS Make sure the assembly to the specified torque, do not over tighten the screw to the specified torque. Otherwise, it could result in product damage. 4

1. Product Overview This installation guide is applied to the LSLV S100 / H100 drive series Option.. 2. Before using the product Perform the following tasks after receiving the conduit option. Inspect the conduit option for damage. If the conduit option appears damaged upon receipt, contact the shipper immediately. Check the label of model whether it is as same as the model number printed on the package of the conduit option. 3. Installation Procedure Option Assembly and Installation Procedure DANGER! Electrical Shock Hazard : Do not connect or disconnect wiring while the power is on. Failure to comply will result in death or serious injury. Wiring and periodic inspections should be performed at least 10 minutes after disconnecting the input power And after checking the DC link voltage is discharged with a meter (below DC 30V) 5

3.1 S100 0.4~4.0kW 1 Remove the I/O cover and cable guide of the product as shown in the Figure 1. Figure 1. Remove I/O Cover and CABLE Guide 2 Fasten the Option to fit on the ground terminals of the product using the prescribed bolt as shown in the Figure 2. 6 Figure 2. Install and Front Viewing

3 Install the I/O cover again. Figure 3. After installation 3.2 S100 5.5~22kW 1 Remove the Power cover and cable guide of the product as shown in the Figure 4. Figure 4. Remove Power Cover and CABLE Guide 7

2 Fasten the Option to fit on the side of ground terminals of the product using the prescribed bolt as shown in the Figure 5. Figure 5. Install 3 Install the Power cover again. 8 Figure 6. After installation

3.3 S100 30~75kW 1 Remove the Power cover and cable guide of the product as shown in the Figure 7. Figure 7. Remove Power Cover and CABLE Guide 2 Fasten the Option to fit on the ground terminals and both ends (4points) of the product using the prescribed bolt as shown in the Figure 8. Figure 8. Install 9

3 Install the Power cover again. Figure 9. After installation 10

3.4 H100 0.8~30kW 1 Remove the Power cover and cable guide of the product as shown in the Figure 10. Figure 10. Remove Power Cover and CABLE Guide 2 Fasten the Option to fit on the side of ground terminals of the product using the prescribed bolt as shown in the Figure 11. Figure 11. Install 11

3 Install the Power cover again. 3.5 H100 37~90kW Figure 12. After installation 1 Remove the Power cover and cable guide of the product as shown in the Figure 13. 12 Figure 13. Remove Power Cover and CABLE Guide

2 Fasten the Option to fit on the ground terminals and both ends (4points) of the product using the prescribed bolt as shown in the Figure 14. Figure 14. Install 3 Install the Power cover again. Figure 15. After installation 13

4. S100 Product Size (Drive with Option) LSLV S100 0.4kW 2/4 Drive + 14

LSLV S100 0.4kW 1, 0.8kW 2/4 Drive + 15

LSLV S100 0.8kW 1, 1.5kW 2/4 Drive + 16

LSLV S100 1.5kW 1, 2.2kW 2/4 Drive + 17

LSLV S100 2.2kW 1, 3.7kW 2/4, 4.0kW 2/4 Drive + 18

LSLV S100 0.4kW 1/4(EMC), 0.8kW 4(EMC) Drive + 19

LSLV S100 0.8kW 1(EMC), 1.5kW 1/4(EMC), 2.2kW 4(EMC) Drive + 20

LSLV S100 2.2kW 1(EMC), 3.7~4.0kW 4(EMC) Drive + 21

S100/H100 Option Installation Manual LSLV S100 5.5~7.5kW 2/4 Drive + 22

S100/H100 Option Installation Manual LSLV S100 11kW 2/4, 15kW 4 Drive + 23

LSLV S100 15kW 2, 18.5~22kW 4 Drive + 24

LSLV S100 30kW 4 Drive + 25

LSLV S100 37~45kW 4 Drive + 26

LSLV S100 55~75kW 4 Drive + 27

5. H100 Product Size (Drive with Option) LSLV H100 0.8~11kW 2/4 Drive + 28

LSLV H100 15kW 2/4, 18.5kW 4 Drive + 29

LSLV H100 18.5kW 2, 22~30kW 4 Drive + 30

LSLV H100 37kW 4 Drive + 31

LSLV H100 45~55kW 4 Drive + 32

LSLV H100 75~90kW 4 Drive + 33

6. Dimensions & Screw Product - capacity W1 H1 D1 Terminal Screw Size Screw Torque (Kgf cm/nm) 0004S100-1/2/4 0008S100-2/4 68 (2.68) 89.6 (3.52) 33.5 (1.32) 0008S100-1 100 89.6 38.5 0015S100-1 /2/4 (3.93) (3.53) (1.51) 0022S100-2 /4 0022S100-1 0037S100-2 /4 0040S100-2 /4 004S100-1/4 (EMC Type) 008S100-4 (EMC Type) 008S100-1 (EMC Type) 015S100-1/4 (EMC Type) 022S100-4 (EMC Type) 022S100-1 (EMC Type) 037S100-4 (EMC Type) 040S100-4 (EMC Type) 0055S100-2 /4 0075S100-2 /4 0110S100-2/4 0150S100-4 0150S100-2 0185S100-4 0220S100-4 0300S100-4 0370S100-4 0450S100-4 0550S100-4 0750S100-4 0055H100-2/4 0075H100-2/4 0110H100-2/4 0150H100-2/4 0185H100-4 0185H100-2 0220H100-4 0300H100-4 0370H100-4 0450H100-4 0550H100-4 0750H100-4 0900H100-4 140 (5.51) 68 (2.68) 100 (3.93) 140 (5.51) 160 (6.23) 180 (7.08) 215 (8.46) 275 (1.08) 325 (12.79) 325 (12.79) 160 (6.30) 180 (7.08) 215 (8.46) 275 (1.08) 325 (12.79) 325 (12.79) 89.1 (3.51) 91.2 (3.59) 86.3 (3.39) 85.7 (3.37) 83.3 (3.28) 89.3 (3.52) 90.6 (3.56) 192 (7.56) 192 (7.56) 187 (7.36) 117.6 (4.63) 125.9 (4.95) 120 (4.72) 184 (7.24) 184 (7.24) 179 (7.05) 43 (0.16) 33.5 (1.32) 37.4 (1.47) 44.4 (1.75) 45 (0.17) 49 (1.93) 63.5 (2.5) 112.5 (4.43) 134 (5.27) 183 (7.20) 55.6 (2.18) 60 (2.36) 64 (2.52) 112.5 (4.43) 134 (5.27) 183 (7.20) M3 M4 2.1~6.1/0.2~0.6 M5 4.0~10.2/0.4~1.0 M8 61.2~91.8/6.1~9.2 M4 2.1~6.1/0.2~0.6 M5 4.0~10.2/0.4~1.0 M8 61.2~91.8/6.1~9.2 W,H,D Units : mm(inches) 34

7. Revision History No Date Editioin Changes 1 2016.11 First Edition - 35