Technical specification Marine Master Clock

Similar documents
Neon pr. ph/ ORP measurement. Applications. Description

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Main Options. Synchronisation source: Satellite (GPS) Terrestrial Low Frequency (MSF, DCF77, WWVB, etc) Timecode (IRIG, AFNOR, etc)

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Programmable Relay ZEN V2 Units

TM221M16TG controller M IO transistor PNP spring

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

TM221ME32TK controller M IO transistor PNP Ethernet

TM221M32TK controller M IO transistor PNP

General information Engineering with Programming package. Display with display

TM221M16R controller M IO relay

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

KS5 SYNCHRONIZATION METER

General information. Display. Supply voltage

NF760 Batch Controller

ATU800. Technical specification

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Micro Motion Model 7950 and Model 7951 Signal Converters

General information. Display. Supply voltage. Input current

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

TM221CE40T controller M IO transistor PNP Ethernet

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Technical Information Fieldgate SFG500

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

APP 700 Technical Specification

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

TM200CE24T controller M IO transistor Source+ Ethernet

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

CPU 1214C. Overview. Design. The compact CPU 1214C has:

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

SM100. On-Line Switchgear Condition Monitoring

Power Meter PowerMonitor 500

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

RIC PROGRAMMABLE INTELLIGENT CONTROLLER

MCX08M2 Programmable controller

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

is then retained absolutely without interruption.

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

General information. Display. Supply voltage. Input current

TM221CE24R controller M IO relay Ethernet

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

General information. Display. Supply voltage

TM221CE40R controller M IO relay Ethernet

MID approval no. DE-08-MI004-PTB004 Date of release

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

TM241CE24T controller M IO transistor PNP Ethernet

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

TM241CE40R controller M IO relay Ethernet

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Lux Intelligent Emergency Light Testing System. Lx Features

Momentum 171 CCC Processor with Ethernet Communication Port

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

LBVR1718. Description. Features channel paperless recorder

ProtoConvert Modbus RTU / Modbus TCP/IP / BACnet MSTP / BACnet IP / SNMP - Telnet (Lighting Controller) PG

TM221ME16T controller M IO transistor PNP Ethernet

SH2WEB24. Central unit module. Benefits. Description

AC-DC Converter REC K10

TM241CE24T controller M IO transistor PNP Ethernet

MIC-2 Multi-instrument DATA SHEET

General information. Display. Supply voltage. Input current

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Pen Drive USB Datalogger!

PS U Series W to 3000 W. Programmable DC Power Supplies THE POWER TEST EXPERTS.

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

TM241CE40R controller M IO relay Ethernet

SA2WEB24. Central unit module. Benefits. Description

AIAS. Technical description

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM241CE40R controller M IO relay Ethernet

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Master Time Center. Control Center for Multifunctional Time Distribution Systems and Mains Frequency Supervision

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Transcription:

Page: 1 av 5 Technical specification Marine Master Clock 1 2 1 0 A MON 24 APR 2006 21.07:36 LT ALARM POWER RADIO LINK NO LT UTC LT General The master clock has 6 buttons and one (2 line x 16 character) LCD. To facilitate time zone change there are 2 separate buttons for this purpose. The master clock also has a dimmer to adjust background illumination. Technical data Crystal frequency: 4,915200 MHz. Accuracy: 0,1 sek./24 hours (+20C ). Microprocessor: HD6412394. Time memory: 30 days (Back-up with Super Capacitor) Ambient temperature: 0 C to +50 C. Relative humidity: Max. 85% non-condensing. Case: 19 case according to drawing 085811-00. IP rating: IP20 Weight: 5.0 kg. CE-approval, EMC Emission according to EN61000-6-3, Immunity according to EN61000-6-2.

Page: 2 av 5 Outputs for slave movements *: Control clocks: Output 1: Output 2: Output 3: Output 4: Analogue display, with background illumination. 2-wire,. 3-wire for forward forward/back. 1/1-minute alt. 1/2-minute. Max. load / output: 2A Total load all outputs together: 2.5A The outputs have short circuit protection that is restored automatically. *Analogue intelligent slave clocks connected to time code output receive the time code and steps to correct time by rapid impulses. The rapid impulses have a speed of approx. 10 steps /second. To step forward 11 hours takes approx. 1 minute and 10 seconds.

Page: 3 av 5 Relay outputs Number of outputs: 2 Changeover potential-free contacts. Max load/relay output: 230 V 6A. Program memory: 100 year (EEPROM). Signal points: 800 Special pulse output Relay output no. 2 can be dedicated to send out a special pulse. When this function is enabled the relay is activated every day for 5 seconds at 02.00 UTC. Telegraph Logger Clock signal If one of the impulse outputs is configured to work as telegraph logger clock signal (1/2M-12B), then relay output no. 2 is used to send out a Counter C.W. signal and can not be used for other purposes. Alarm output Number of outputs: Type of alarms Output no. 1 (general alarm): Output no. 2 (power alarm): 2 Changeover potential-free contacts. Overload / short circuit, synchronisation alarm Power failure alarm

Page: 4 av 5 Serial ports The Master Clock is equipped with two serial ports, one RS232 and one RS422/485. Both ports can be used either as input or output for serial time messages. If programmed as output the port can be used to send out time to external equipment such as computers etc. If programmed as input the port can be used to synchronise the master clock with an external time source provided with RS232 or RS485 output. The purpose of this is to achieve higher accuracy. Protocol, data format and baud rate is selectable for respective serial port. Serial output Baud rate (selectable): 300, 600, 1200, 2400, 4800, 9600, 19200 baud. Data format (selectable) 7N1, 7N2, 7O1, 7O2, 7E1, 7E2, 8N1, 8N2, 8O1, 8O2, 8E1, 8E2 No. of data bits: 7 or 8. Type of parity: None, odd or even. No. of stop bits: 1 or 2. Selectable data format: Available protocols - ZDA Time string, NMEA 0183 - Westerstrand protocol no. 2, 3, 5, 7 etc. (Automatic time message protocols) Type of time (selectable): UTC, LT Serial input Baud rate: 4800 baud. Data format: 8N1 Type of protocol: ZDA Time string, NMEA 0183

Page: 5 av 5 Power supply The master clock has two inputs for power supply, one for AC, and one for 24V DC. As standard the DC-input is a direct connected input without galvanic isolation and no compensation for low input voltage. With option DC/DC the DC-input will be galvanic isolated and low / high input voltage is compensated automatically. Supply voltage: Option DC/DC: (Galvanic isolated) Input voltage: Output voltage: Isolation voltage: Power consumption AC: DC: 90-264V 50/60 Hz and 24VDC. 19-36VDC 23 30VDC (adjustable) 1500V 65W 50W Options DC/DC -converter Ethernet LAN connection GPS-receiver Table model Software for time to computer, WINT Ethernet LAN (option) Protocol: NTP according to RFC1305 and RFC1361, TCP/IP Compatibility: Ethernet version 2/IEEE 802.3 Ethernet: Connection 100BASE-T (RJ45) Rules and regulations The Marine Master Clock fulfils the rules according to IEC / EN60945:2002, maritime navigation and radiocommunication equipment and systems.