Data sheet CC 03, Commander Compact (603-1CC21)

Similar documents
Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Data sheet CPU 115 (115-6BL02)

Data sheet VIPA CPU 115DP (115-6BL22)

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/PN ECO (315-4PN33)

Data sheet CPU 013C (013-CCF0R00)

Operating and Monitoring Systems

Data sheet VIPA CPU M13C (M13-CCF0000)

Data sheet CPU 015PN (015-CEFPR00)

Data sheet CPU 015PN (015-CEFPR01)

Data sheet SLIO CPU 015PN (015-CEFPR01)

VIPA HMI. Commander Compact CC 03 Manual

Product type designation. General information. Supply voltage. Input current

General information. Supply voltage

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Product type designation. General information. Supply voltage

SIPLUS CPU 313C-2DP. Function

System description SLIO

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current. Power loss

Product type designation. General information. Supply voltage. Input current. Power losses

Main Catalog 2012/2013 for specialists in automation and control technology

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

Supply voltage. Input current. Encoder supply. Memory

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

Main Catalog 2012/2013 for specialists in automation and control technology

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Supply voltage. Input current

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Supply voltage. Input current

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

General information. Display. Supply voltage

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

Product type designation

General information. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Display. Supply voltage

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

CPU 412H. Function. Parameterizable properties

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information Engineering with Programming package. Display with display

Structure and Function

Product type designation. General information. Supply voltage

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

SIMATIC S /2 3/4 3/22 SIPLUS 3/26 3/33 SIPLUS

Fieldbus slave modules w/o I/Os

CPU 1214C. Overview. Design. The compact CPU 1214C has:

SIMATIC S /2 Introduction

VIPA System 200V. CPU Manual

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

General information. Supply voltage

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

General information. Configuration control. Display. Control elements. Supply voltage

CPU 412. Function. Programmable properties

Transcription:

Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory: 128 kb Languages: DE, EN, FR, ES, IT, SV, NO, DA Project engineering via VIPA OP-Manager or Siemens ProTool Integrated PLC-CPU: 16/24kByte work/load memory, 16 x DI, 16 x DO, up to 4 I/O expansion modules Display Number of rows 2 Characters per row 20 Character height Type of display 5 mm STN with LED backlighting OP functionality User memory 128 KB Number of variables 4096 Language DE/EN/FR/ES/IT/SV/NO/DA Operating controls Touchscreen - Mouse - Number of system keys 8 Number of soft keys 5 Technical data power supply Power supply (rated value) Power supply (permitted range) DC 20.4...28.8 V Reverse polarity protection Current consumption (-load operation) 130 ma Current consumption (rated value) 1 A Inrush current 60 A I²t 0.35 A²s Max. current drain at backplane bus 0.8 A Max. current drain load supply - Power loss 8 W Reverse polarity protection Technical data digital inputs Number of inputs 16 Cable length, shielded Cable length, unshielded 1000 m 600 m Page 1/6

Rated load voltage Reverse polarity protection of rated load voltage Current consumption from load voltage L+ (without load) - Rated value Input voltage for signal "0" DC 0...5 V Input voltage for signal "1" DC 15...28.8 V Input current for signal "1" 7 ma Connection of Two-Wire-BEROs possible Max. permissible BERO quiescent current 1.5 ma Input delay of "0" to "1" 3 ms Input delay of "1" to "0" 3 ms Input characteristic curve IEC 61131-2, type 1 Initial data size 2 Byte Technical data digital outputs Number of outputs 16 Cable length, shielded 1000 m Cable length, unshielded 600 m Rated load voltage Reverse polarity protection of rated load voltage - Current consumption from load voltage L+ (without load) 50 ma Total current per group, horizontal configuration, 40 C 4 A Total current per group, horizontal configuration, 60 C 4 A Total current per group, vertical configuration 4 A Output voltage signal "1" at min. current L+ (-125 mv) Output voltage signal "1" at max. current L+ (-0.8 V) Output current at signal "1", rated value 0.5 A Output delay of "0" to "1" max. 100 µs Output delay of "1" to "0" max. 350 µs Minimum load current - Lamp load 5 W Switching frequency with resistive load max. 1000 Hz Switching frequency with inductive load max. 0.5 Hz Switching frequency on lamp load max. 10 Hz Internal limitation of inductive shut-off voltage L+ (-52 V) Short-circuit protection of output, electronic Trigger level 1 A Output data size 2 Byte Technical data counters Number of counters - Counter width - Maximum input frequency - Maximum count frequency - Mode incremental encoder - Mode pulse / direction - Mode pulse - Mode frequency counter - Mode period measurement - Page 2/6

Gate input available - Latch input available - Reset input available - Counter output available - Status information, alarms, diagstics Status display Interrupts Process alarm Diagstic interrupt Diagstic functions Diagstics information read-out Supply voltage display Group error display Channel error display possible green LED red SF LED red LED per group Isolation Between channels of groups to 8 Between channels and backplane bus Insulation tested with DC 500 V Load and working memory Load memory, integrated 24 KB Load memory, maximum 24 KB Work memory, integrated Work memory, maximal Memory divided in 50% program / 50% data - Memory card slot MMC-Card with max. 512 MB Hardware configuration Racks, max. 1 Modules per rack, max. 4 Number of integrated DP master 0 Number of DP master via CP 4 Operable function modules 4 Operable communication modules PtP 4 Operable communication modules LAN - Command processing times Bit instructions, min. 0.25 µs Word instruction, min. 1.2 µs Double integer arithmetic, min. 2.6 µs Floating-point arithmetic, min. 50 µs Timers/Counters and their retentive characteristics Number of S7 counters 256 S7 counter remanence adjustable 0 up to 64 S7 counter remanence adjustable C0.. C7 Number of S7 times 256 S7 times remanence adjustable 0 up to 128 Page 3/6

S7 times remanence adjustable t retentive Data range and retentive characteristic Number of flags 8192 Bit Bit memories retentive characteristic adjustable adjustable 0 up to 256 Bit memories retentive characteristic preset MB0.. MB15 Number of data blocks 2047 Max. data blocks size Number range DBs 1... 2047 Max. local data size per execution level 1024 Byte Max. local data size per block 1024 Byte Blocks Number of OBs 14 Maximum OB size Total number DBs, FBs, FCs - Number of FBs 1024 Maximum FB size Number range FBs 0... 1023 Number of FCs 1024 Maximum FC size Number range FCs 0... 1023 Maximum nesting depth per priority class 8 Maximum nesting depth additional within an error OB 4 Time Real-time clock buffered Clock buffered period (min.) 30 d Type of buffering Vanadium Rechargeable Lithium Battery Load time for 50% buffering period 20 h Load time for 100% buffering period 48 h Accuracy (max. deviation per day) 10 s Number of operating hours counter 8 Clock synchronization - Synchronization via MPI Synchronization via Ethernet (NTP) Address areas (I/O) Input I/O address area 1024 Bit Output I/O address area 1024 Bit Process image adjustable - Input process image preset Output process image preset Input process image maximal Output process image maximal Digital inputs 8192 Digital outputs 8192 Digital inputs central 144 Digital outputs central 144 Integrated digital inputs 16 Page 4/6

Integrated digital outputs 16 Analog inputs 512 Analog outputs 512 Analog inputs, central 32 Analog outputs, central 16 Integrated analog inputs - Integrated analog outputs - Communication functions PG/OP channel Global data communication Number of GD circuits, max. 4 Size of GD packets, max. 22 Byte S7 basic communication S7 basic communication, user data per job 76 Byte S7 communication S7 communication as server S7 communication as client - S7 communication, user data per job 160 Byte Number of connections, max. 16 Functionality Sub-D interfaces Type MP²I Type of interface RS485 Connector Sub-D, 9-pin, female Electrically isolated - MPI MP²I (MPI/RS232) DP master - DP slave - Point-to-point interface - 5V DC Power supply max. 90mA, n-isolated 24V DC Power supply max. 100mA, n-isolated Type - Type of interface - Connector - Electrically isolated - MPI - MP²I (MPI/RS232) - DP master - DP slave - Point-to-point interface - 5V DC Power supply - 24V DC Power supply - Functionality MPI Number of connections, max. 16 PG/OP channel Page 5/6

Routing - Global data communication S7 basic communication S7 communication S7 communication as server S7 communication as client - Transmission speed, min. 19.2 kbit/s Transmission speed, max. 187.5 kbit/s Functionality PROFIBUS slave PG/OP channel - Routing - S7 communication - S7 communication as server - S7 communication as client - Direct data exchange (slave-to-slave communication) - DPV1 - Transmission speed, min. - Transmission speed, max. - Automatic detection of transmission speed - Transfer memory inputs, max. - Transfer memory outputs, max. - Address areas, max. - User data per address area, max. - Mechanical data Housing / Protection type Material die-cast aluminum Mounting via integrated pivoted lever Protect type front side IP 65 Protect type back side IP 20 Dimensions Front panel Rear panel 187 mm x 90 mm x 6 mm 154 mm x 77 mm x 55 mm Installation cut-out Width Height Minimum Maximum front panel thickness Net weight 156 mm 78 mm 2.5 mm 6 mm 580 g Environmental conditions Operating temperature 0 C to 60 C Storage temperature -20 C to 70 C Certifications UL certification KC certification - Page 6/6