Installation and Programming Manual. This Manual describes the IBSS InterBus-S Slave, its uses and set up.

Similar documents
Installation and Programming Manual

Installation and Programming Manual

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

Installation and Programming Manual

Installation and Programming Manual

Installation and Programming Manual

Installation and Programming Manual. This Manual describes the MLWF (Momentum LONWORKS Free Topology), its uses and set up.

QUCM ACCU-SORT. Installation and Programming Manual

Accessories IC690ACC900

QUCM Limitorque Controller

IBS ST (ZF) 24 BK LB-T

Installation and Programming Manual

DEB SY/MAX Video. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

PMEUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

DEB Setup Video. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

PLCADD1616 User Guide 3/29/10. Overview

Installation and Programming Manual

PAC BI-DP BIM and 8701-CA-BI Carrier

MUCM ModLon Gateway. Installation and Programming Manual

8520/8520R. User Manual

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

IBS IL 24 BK RB-T-2MBD

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

Type IBS EVA BASIC IBS EVA ADDITION 1 IBS EVA ADDITION 2 IBS SIG PART 2 UM IBS SIG PART 2 UM E. length: 50 mm acc. to RS x 9-pin D-SUB

SER-4485-SI-M USER S MANUAL

VersaMax IP I/O Module

Edition. INTERBUS UFI11A Fieldbus Interface 06/2002. Manual / EN

TABLE OF CONTENTS. Communication Functions

GFK-2415A March Type of sensor connection

1. FEATURES AND BENEFITS

I / O Expander. Instrument for torque control ASL 11/17

Defining the Future in Motion Control

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

VersaMax IP Input Module

FAST_EnergyCam-Communication-Interfaces.doc 7/7/2016 Page 1 of 6

Installing the DX LCD Display

-C5RS-LC RS232 EXTENDER

Installation and Programming Manual

Installation and Programming Manual

A66SM Installation and Programming Manual

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

TURCK Modular Industrial I/O PROFIBUS -DP Products

ICN Mini Link/External. User s Guide. 1733N Model A Mini Link/EXT (Version 1) 1732N Model A ICN Interface Board (Version 1)

ADDJOG User Guide 7/30/10. Overview

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

270 MHz Control Modules

IQ3/XNC M-Bus Master

Installation and Programming Manual

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

PAS 300, PROFIBUS Slave Interface Module

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

IST ULTRASTAB Power Supply for high precision transducers

Absolute Encoder HE-65-M

es Six programmable controller and Input/Output Communications Control Module (I/O CCM) IC600BF948 General Description GEK-90824D July 1989

Device/PLC Connection Manuals

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

UC-2000 Installation Manual Unicorn Computers Technology Limited

The possibility of combining interface modules allows various bus and network systems to be integrated into the B&R SYSTEM 2005.

CAN 300 PRO, Communication Module

Installation and Programming Manual

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

Features: Analog to Digital: 12 bit resolution TTL outputs, RS-232 tolerant inputs 4.096V reference (1mV/count) 115K max speed

BeagleBone Black USB Expansion RS232 Module Cape Coolgear, Inc. Version 1.1 September 2017 Model Number:

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

AXL E IOL AO1 U M12 R

LMC078CECS20T motion controller LMC078-20DIO transistor sercos compact Ethernet Canopen 24Vdc

LT900SERIES. 1xN Multi-Channel Switch Operation Manual

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

T1K MODBUS Base Controller Specifications

Overview. The DIN-RS232 has three primary functions: Isolated parallel RS-232 interface Fused power distribution Animatics peripheral expansion bus

Single Phase Systems-North American PC125/PC420 Series

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

LIN bus board datasheet EB

Gateway 1400 Reference Manual

L5351 DeviceNet Communications Interface

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

TRP-C06H User s Manual

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

IB IL 24 DI 16 IB IL 24 DI 16-PAC

IBS PCI SC/I-T. Controller Board for PC Systems With PCI Bus. Data Sheet 6039B

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

Bulletin 2707 DTAM Plus Operator Interface Product Data

SEI-USB. SEI to USB Adapter Page 1 of 5. Description. Features

RS-422/485 PCIe Card

GS202 Encoder Switch

MTI Embedded Controller Part Number 91695

PSI-GPRS/GSM-MODEM/RS232-QB

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

Transcription:

IBSS Manual IBSS Installation and Programming Manual This Manual describes the IBSS InterBus-S Slave, its uses and set up. Effective: 03 June, 1996 Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO 64803 USA Telephone: (800) 235-6723 or (417) 624-8918 Facsimile: (417) 624-8920 BBS: (417) 624-2028 Internet: http://niobrara.com

SY/MAX and Square D are registered trademarks of Square D Company. Subject to change without notice. Niobrara Research & Development Corporation 1996. All Rights Reserved.

Contents 1 Introduction...5 Specifications... 6 Module Specifications... 6 2 Installation...9 Module Installation... 9 IBS installation... 9 IBS Configuration... 10 3 Operation...11 InterBus-S Overview... 11 Memory Configuration... 12 IBS Output Words 1 through 4... 12 IBSS Status... 12 IBS Input Words 1 through 4... 12 IBSS Command... 13 4 Connector Pinouts... 15 InterBus-S Remote Bus IN port on IBSS (DE9P with 4-40 jack sockets)...15 InterBus-S Remote Bus Out port on IBSS (DE9S with 4-40 jack sockets)...16 External 24VDC supply connector... 16 5 Recommended Cabling... 17 Figures InterBus-S Remote Network Cabling... 17 Figure 1-1 IBSS Front Panel... 7 Figure 4-1 InterBus-S Remote Bus In Connector Pinout...15 Figure 4-2 InterBus-S Remote Bus Out Connector Pinout...16 Figure 4-3 24VDC External Connector... 16 Figure 5-1 InterBus-S Remote Cable... 17 3

Tables Table 1-1 IBSS Register List... 5 Table 3-1 IBSS Register List... 12 Table 3-2 IBSS Status Register Bits... 12 4

1 Introduction The Niobrara IBSS (InterBus-S Slave) is a SY/MAX compatible module that performs the function of Remote Bus Slave with I/O on an InterBus-S network. The IBSS interfaces with the SY/MAX PLC through the Square D SY/MAX register rack to provide access to the InterBus-S network through the backplane. Communication with the InterBus-S devices is through isolated RS-485 InterBus-S Remote Bus connectors on the front panel of the module. An external isolated 24VDC power supply may be used to provide uninterrupted IBS operation while the SY/MAX Rack is removed from service. All data is stored in the IBSS in standard 16 bit SY/MAX compatible registers. The IBSS provides 4 words of Interbus-S Outputs and Inputs. The IBSS has 10 SY/MAX Rack Addressable registers which are divided into ranges for the IBS Outputs, IBSS Status, IBS Inputs, and IBSS Command. Table 1-1 displays this information. Table 1-1 Register Range IBSS Register List Function PLC Status in hex (Direction) 1 IBS Output Word 1 E000 (PLC Input) 2 IBS Output Word 2 E000 (PLC Input) 3 IBS Output Word 3 E000 (PLC Input) 4 IBS Output Word 4 E000 (PLC Input) 5 IBSS Status (See Table 3-2) E000 (PLC Input) 6 IBS Input Word 1 A000 (PLC Output) 7 IBS Input Word 2 A000 (PLC Output) 8 IBS Input Word 3 A000 (PLC Output) 9 IBS Input Word 4 A000 (PLC Output) 10 IBSS Command A000 (PLC Output) IBSS Manual 1 Introduction 5

Specifications Module Specifications Mounting Requirements One register slot of a Square D Class 8030 Type CRK, DRK, GRK, HRK, or RRK I/O. Current Draw on SY/MAX power supply 400mA @ 5VDC Current Draw on external 24VDC power supply 80mA @ 24VDC while SY/MAX Power ON. 150mA @ 24VDC while SY/MAX Power OFF. Operating Temperature 0 to 60 degrees C operating. -40 to 80 degrees C storage. Humidity Rating up to 90% noncondensing Pressure Altitude -200 to +10,000 feet MSL InterBus-S Communication Ports 9 pin D-connectors, optically isolated RS-485 compatible. Fixed 500K baud InterBus-S protocol. Male Connector - Remote Bus IN, Female Connector - Remote Bus Out. Indicator lights 3 LEDs: Green SY/MAX Rack Power, Green 24VDC power, Green RC, Green BA, and Red Error. Physical Dimensions Single width module. Wt: 2.5 lb. W: 1.5 in. H: 12.8 in. D: 6.6 in. 6 Introduction 1 IBSS Manual

IBSS InterBus-S Slave Indicators (LEDs) Rack Power (Green) - Lights when SY/MAX Rack is providing 5 VDC. Rack Power RC BA RC (Green) - Remote Bus Connection. Lights when the Remote Bus connection is OK. Flashes when the network is incorrectly configured. BA (Green) - Remote Bus Active light. On when the IBSS is an active node on the Remote Bus. Flashes when the network is incorrectly configured. Error (Red) - Lights on Remote Bus Errors. Error Remote Bus In Remote Bus In Port InterBus-S standard male 9-pin D-subminiature connection to remote bus. Remote Bus Out Remote Bus Out Port InterBus-S standard female 9-pin D-subminiature connection to remote bus. 24VDC + 24 VDC - External Power Supply Indicator 24VDC (Green) - Lights when the external 24VDC supply is present. External Power Supply Connector 24VDC supply for powering IBSS when SY/MAX rack power is off to allow IBS operation while servicing the SY/MAX system. Figure 1-1 IBSS Front Panel IBSS Manual 1 Introduction 7

2 Installation Warning Do NOT install or remove the IBSS with power applied to the Rack. Turn OFF power at the power supply. Damage to the equipment may occur if the power is on during installation. Module Installation IBS installation 1 Remove power from the rack. 2 Mount the IBSS in an available slot in the register rack. Secure the screw at the bottom of the module. 3 Apply power to the rack. The green Rack Power light should illuminate and remain lit. The IBSS connects to the InterBus-S network using its Remote Bus In port. The IBSS uses the 2 Twisted-Pair Remote Bus Wiring scheme and the pinout of its 9 pin port is compatible with Phoenix Contact products.. Connect to the previous Remote Bus device with a proper remote bus cable such as the Niobrara IR9D cable shown on page 17. For a complete IBS overview see the Phoenix Contact document: InterBus-S Instruction Manual IBS SYS INST UM E Order No.: 27 54 804. This document may be ordered from Phoenix Contact. Downstream Remote Bus devices may be connected to the Remote Bus Out port of the IBSS with an IR9D cable. If it is desired to have the IBS network continue to operate when the SY/MAX rack power is removed, connect a suitable 24VDC supply to the connector on the front of the IBSS. The green 24VDC light will be on when the external power is connected. IBSS Manual 2 Installation 9

IBS Configuration The IBS Master for the network requires the identity and width of each device on the network; the IBSS ID is 03 and the Module width is 4 words. The first 4 SY/MAX registers provide the IBS outputs (PLC Inputs). The 5th register provides status (PLC Input) of the IBSS. The 6th through 9th registers are the IBS Inputs (PLC Outputs). The 10th register (PLC Output) is a reserved command register for the IBSS and is currently not implemented. 10 Installation 2 IBSS Manual

3 Operation InterBus-S Overview The InterBus-S sensor/actuator network operates in a manner that is effectively a large shift register. The IBS Master keeps a table of registers that corresponds to all of the output bits on the InterBus-S network. The IBS Master also keeps a table that corresponds to all of the input bits on the IBS network. During a normal scan of the IBS network, the Master clocks output data to the network modules while the modules clock their input data to the Master. Each device on the IBS network checks the integrity of the data with CRC calculations between nodes. The data must pass all checks around the loop before it is allowed to be latched in the outputs or placed in the Master s input table. This structure requires the Master and all of the modules on the IBS network to know the size of the network. This is accomplished by the Master issuing an ID cycle. The ID cycle information allows the Master to know the exact I/O module type and position on the bus. The Master keeps a table of the current bus layout and compares the current bus to a table that contains the intended bus layout. If the tables do not match, the Master will halt the IBS network. The IBSS has a network ID of 03 and has a width of 4 words. The IBS serial protocol is implemented in two formats: remote bus and local bus. Both of these bus types operate in the same manner for shifting the data but differ in transmission distance. The remote bus operates at differential RS-485 levels for long distance communication of up to 1300 feet. Up to 32 remote bus devices may be connected to a single master. Only serial communication is passed through the remote bus cable. Each remote bus device is independently powered as no power passes through the remote bus. The IBSS is remote bus device. The local bus is intended for localized areas of I/O. The local bus is limited to 8 modules with a maximum cable length of 32 feet. The communication ports of each local IBSS Manual 3 Operation 11

Memory Configuration bus device are powered by the remote bus terminal. The communication levels are TTL on the local bus. The operation of the IBSS is fixed with four words of IBS outputs and four words of IBS inputs determined by the configuration in its memory. The IBSS s internal useraccessible memory is represented as SY/MAX processor equivalent registers. A list of available registers is shown in Table 3-1. Table 3-1 Register Range IBSS Register List Function PLC Status in hex (Direction) 1 IBS Output Word 1 E000 (PLC Input) 2 IBS Output Word 2 E000 (PLC Input) 3 IBS Output Word 3 E000 (PLC Input) 4 IBS Output Word 4 E000 (PLC Input) 5 IBSS Status (See Table 3-2) E000 (PLC Input) 6 IBS Input Word 1 A000 (PLC Output) 7 IBS Input Word 2 A000 (PLC Output) 8 IBS Input Word 3 A000 (PLC Output) 9 IBS Input Word 4 A000 (PLC Output) 10 IBSS Command A000 (PLC Output) IBS Output Words 1 through 4 Registers 1 through 4 provide the IBS Output Words 1...4. These 16 bit registers are PLC Inputs and thus read only by the SY/MAX PLC. The data in these registers should only be considered valid when bit 1 of register 5 is set. The data in these registers is zeroed by the IBSS if the IBS network stops or if the unit is unplugged. IBSS Status Register 5 provides status bits concerning the operation of the IBSS. This register is a PLC input and thus read only to the SY/MAX PLC. Table provides the descriptions of each bit. Table 3-2 IBSS Status Register Bits Bit Description 1 Set if IBS is active. 2..14 Reserved. 15 Set if 5V from SY/MAX Rack is present. 16 Set if external 24VDC is present. IBS Input Words 1 through 4 Registers 6 through 9 provide the IBS Input Words 1..4. These 16 bit registers are PLC Outputs and may be written by the SY/MAX PLC. The data in these registers is zeroed when the PLC is halted, powered down, or set to disable outputs. 12 Operation 3 IBSS Manual

IBSS Command Register 10 is reserved as a configuration register for the IBSS. This register is a PLC output and may be written by the SY/MAX PLC. At the present time, all data written to this register is ignored by the IBSS. IBSS Manual 3 Operation 13

4 Connector Pinouts InterBus-S Remote Bus IN port on IBSS (DE9P with 4-40 jack sockets) 1 DI+ receive data (noninverted) from Remote device to IBSS 2 DO+ transmit data (noninverted) from IBSS to Remote device 3 COM isolated from the SY/MAX gnd. 4 No Connection 5 No Connection 6 DI- receive data (inverted) from Remote device to IBSS 7 DO- transmit data (inverted) from IBSS to Remote device 8 No Connection 9 No Connection 6 7 8 9 1 2 3 4 5 Figure 4-1 InterBus-S Remote Bus In Connector Pinout IBSS Manual 4 Connector Pinouts 15

InterBus-S Remote Bus Out port on IBSS (DE9S with 4-40 jack sockets) 1 DO+ transmit data (noninverted) from IBSS to next Remote device 2 DI+ receive data (noninverted) from next Remote device to IBSS 3 COM isolated from the SY/MAX gnd. 4 No Connection 5 Ground. 6 DO- transmit data (inverted) from IBSS to next Remote device 7 DI- receive data (inverted) from next Remote device to IBSS 8 No Connection 9 Remote Downstream Bus Cable Detect. 9 8 7 6 5 4 3 2 1 Figure 4-2 InterBus-S Remote Bus Out Connector Pinout External 24VDC supply connector The IBSS may be powered by an external 24VDC source. This source is isolated from the SY/MAX rack and will only power the Interbus-S portion of the IBSS. This connection will allow the IBS to continue to run even if the SY/MAX rack containing the IBSS is powered down. The green 24VDC light will be on when the external source is active. +24VDC Common Figure 4-3 24VDC External Connector The External Source should provide at least 150mA at 24VDC. 16 Connector Pinouts 4 IBSS Manual

5 Recommended Cabling InterBus-S Remote Network Cabling DE-9P (Remote OUT) DE-9S (Remote IN) 1 pair 1 1 6 pair 1 6 2 pair 2 2 7 pair 2 7 3 Common 3 5 9 Figure 5-1 InterBus-S Remote Cable This is a Niobrara IR9D cable. IBSS Manual 5 Recommended Cabling 17