SPM Zero dead volume dilutor DATASHEET

Similar documents
Mitos Duo XS-Pump Part No

Mitos P-Pump. product datasheet

Installation and operation manual ReciFlow Gas

Liquid Volume Dispenser

F. Z-Series Pump Operator s Manual 200 µl, 1000 µl, 2000 µl and 5000 µl Models

Educational Microfluidic Starter Kit

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Rometec srl Rometec srl Rometec srl -

Flow Control. User s Guide. Programmable Dosing Pumps for Liquid Delivery, Solutions Application & Switching

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

HuddleCamHD RS-232 Joystick Controller Model Number: HC-JOY

Electronic SD1, AS 8, ASR 14, ASR 20

CONFIGURATION: The Reader, LED Indicator, pin numbers for the 9-pin connector and the 25-pin adapter are shown in Figure 1-2.

Upchurch Scientific Nano Flow Sensor User s Guide

Tecan Cavro components overview. Tecan Cavro innovation is everywhere

Intelligent Flow Rate Peristaltic Pump- Lab V Series. Model No.: Lab V1, Lab V3, Lab V6. Acceptable Pump Head: YZ1515x, YZ2515x, SN Series, MC Series

SPECIFICATIONS. SYRINGE SAMPLER (25 ml syringe version) KZ-30W Higashimotomachi, Kokubunji, Tokyo , Japan

Manual for the MicroSIA Instrument

AD Leak Tester INSTRUCTION MANUAL 1WMPD

PROGRAMMABLE STEP MOTOR CONTROLLER R

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

SYRINGE PUMPS SO ADVANCED, THEY RE SIMPLE!

Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.

Output Operating Switch Schmitt Trigger Combination Voltage & Locating Lug 291 V F 832 A B A Rev. D

One station Impact Printer. Model: WP-300 Version : 1.03

The SilverNugget is a servo controller/driver for NEMA 34 frame microstep motors.

SPECIFICATIONS SYRINGE SAMPLER KZ-31W Higashimotomachi, Kokubunji, Tokyo , Japan. No E Printed in Japan

User s Guide. Pressure Controller for liquid delivery systems

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual

Introduction to the FTA4000

GOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S.

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Power Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41

INTEGRATED MICROSTEPPING MOTOR DRIVER AND HIGH PERFORMANCE MACHINE/PROCESS CONTROLLER

HuddleCamHD Serial Joystick Controller Model Number: HC-JOY-G3

Tecan Cavro components overview TECAN CAVRO INNOVATION IS EVERYWHERE

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Flex Series User Guide

opus titration Motorized titration ensures reproducible results

Product Description. Simplifying Motion Control

Graphical User Interface V1.0.3

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

Fixed mount CCD bar code reader NFT Specification Ver. 1.0

Product Overview. Tecan Cavro Components Tecan Cavro innovation is everywhere

User Operation Manual: Motorized Valve Controller for Valved Sources

New Era Pump Systems, Inc Catalog

NEMESYS Hardware Manual and Reference

Bartels Micropumps. DE Seite 14

Pump 33 DDS Dual Drive System

Bartels Micropumps. ( ) rev mp6 double actuator micropump. Functional principle of mp6. mp5 smallest available plastic micropump

"Infuses Only!" Your partner for Scientific & Medical Equipments

Z58-6XX SERIES 6 Digits Universal Position Indicator for incremental or absolute encoders

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

T E M P O S O N I C S I I I INSTALLATION CAUTION! B. CONNECTORS RG Connector. D6 Connector: INTEGRAL CABLE P Integral Cable

Copy Machine Reader. Installation and Setup Guide

Overview INTELLIGEN ULV DISPENSE SYSTEM. Advanced two-stage system enabling superior dispense and filtration of ultra-low viscosity fluids

Sidewinder Pumps Inc. AC Timer/Controller

ME2110: Creative Decisions and Design Electromechanical and Pneumatic Kit Manual

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide

Mechatronics and Pneumatics Kit Manual

Driver/Controller Development Assistance Package For IDEX Health & Science TitanHT TM Driver Board

Electronic Indicator

Evaluation Kit & Driver User s Guide

AD Leak Tester INSTRUCTION MANUAL 1WMPD B

Precise Programmable Syringe Pumps

Modbus Signal Output Adapter Quick Start Guide

14. Chromatography Syringes/Microlitre Syringes

Wireless Receiver W/ USB Output BA/RCVxxx-USB Installation and Operating Instructions

MULTISPENSE 2000 STYLE B CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page #

BenchMark 200/BM470 Marking System

MODEL : TRP-100-II Receipt Printer User s Manual

FG-7000 Digital Force Gauge Operation Manual

Inductive Cylinder Position Sensors

SPID Elektronik. Driver MD-02 MD-02

Microreactor Chips. product datasheet

Multiple-Rotation Absolute Encoder

FEC-240G. Rev. Date

Diamond FLQ-Series. Q-Switched Fiber Lasers FEATURES & BENEFITS

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

TableofContents. Important Information: Warning: Please read operating manual carefully before operation.

MD3. Microstepping Motor Driver Page 1 of 7. Description. Software. Mechanical Drawing. Features

MCS-EB1. Technical Documentation. Colour Sensor Evaluation Board. Table of contents 1. INTRODUCTION 2

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

LN3X Series Motor and Drives

T E M P O S O N I C S I I I INSTALLATION

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

RD-SDM02 Contact Angle Measurement Instrument. Operation Manual

Spraybase Technical Specifications Sheet

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RB-6 6 Channel Power Controller. P/N: Rev 1

Blood Hemolysis Detector User Manual

SeriBox. antrax Datentechnik GmbH

MX Series II Operating Manual. MX Series II Modular Automation for Nano and Analytical Scale HPLC And Low Pressure Fluid Switching Applications

PRESSURE METER OPERATION MANUAL. Model : PS-9302

ADVANCED SYRINGE PUMP

Model 2703AP Quick Reference Guide

F1000 User's Manual. (Version: V1.01)

MICROLAB 600 Series. Intelligent Pipette Automation made Simple

A2K. Absolute Optical Encoder: Kit Version Page 1 of 7. Description. Features

Transcription:

Environmental conditions Operating temperature Humidity Max pressure 5-40 C (41-104 F) 20-80%, non-condensing 5 bars (72 psi) Fluidic characteristics Tube port fittings Wetted materials Channel diameter Standard ¼-28 UNF, flat-bottom PTFE, PCTFE and borosilicate glass 0.5 mm (0.020 in) / 0.4-1 mm (0.015-0.039 in) available upon request Mechanical characteristics VALVE MODELS Default model: VD2-6 Ref. # VD2-6 VD1-6 Name 7-PORT/6-POSITION, 7-PORT/6-POSITION ultra-low carryover volume Liquid path Number of channels 2 1 inside rotary part Internal volume 4.45 μl 4.24 μl Carryover volume 1.4 μl 2.47 μl Dead volume None PLUNGER DETAILS Glossary reminder Internal volume: Volume inside the system, from entrance to exit (does not include the volume in the syringe) Dead volume: Volume that is stuck in the system (dead end), which is not cleanly swept and relies on diffusion to clear out. Carryover volume: Volume of liquid that will be mixed with the next liquid or sample. It is not stuck, but will be swept next time a liquid passes. Travel length Resolution Drive Materials 30 mm with 96 000 micro-steps Selectable 3 000 steps or 24 000 steps Screw drive with linear encoder for step loss detection PTFE or UHMW-PE Web: www.amf.ch 1 of 7 25.01.2017

SYRINGE MODELS Default model: S500-P Ref. # Plunger material Syringe volume [μl] Min. flow rate [μl/min] Max. flow rate [μl/min] Min. dosing volume [μl] S25-P PTFE 25 0.25 750 0.05 S50-P PTFE 50 0.5 1 500 0.1 S100-P PTFE 100 1 3 000 0.2 S100-U UHMW-PE 100 1 3 000 0.2 S250-P PTFE 250 2.5 8 000 0.5 S500-P PTFE 500 5 15 000 1 S500-U UHMW-PE 500 5 15 000 1 S1000-P PTFE 1 000 10 30 000 2 COMPLETE MODULE (Ref. P100-O) Weight Dimensions Default configuration External fixation system 1.5 kg 199.7 x 126.3 x 50.5 mm 500 μl syringe with PTFE plunger (S500-P) 7-port/6-position valve with ultra-low carryover volume (VD2-6) 4x M3 screws, position shown in orange Dimensions are in mm [inch] Web: www.amf.ch 2 of 7 25.01.2017

Electrical characteristics Power Required cables for operation 18-24 VDC, 2.2 A peak USB mini to USB, Power cord (power jack 2mm) Communication interface Interface Communication type USB mini, RS-232 or RS-485 Serial communication The valve controller is seen as a virtual serial port. There is an on-board FTDI USB to serial chip, so the drivers are automatically installed on recent Windows 7 and above. SERIAL COMMUNICATION PARAMETERS Baud rate 9600 Data Bit 8 Parity None Stop Bit 1 Handshake None End line <CR> COMMANDS A command is in the following format: /1 + command + R + <CR> For example, the pump is initialised with the command Z, so the instruction to send to the pump would be /1ZR<CR> A new command can only be sent once the first one is done, or if an error appears. A status message is always sent from the pump, so it is possible to debug the system in case of error. You will find a list of most used commands below. Please refer to the operating manual for an extensive list of commands and error codes. Pump configuration commands Command Operand n range Default value Operand description N<n> 0..1 0 <0> = 0.01 mm resolution microstep <1> = 0.00125 mm resolution microstep Command description Initialise the plunger drive and do valve homing E.g. /1N1R<CR> will choose the 0.01 mm resolution microstepping mode. Web: www.amf.ch 3 of 7 25.01.2017

Control commands Command Operand n range Default Operand Command description value description R - - - Execute command string X - - No trailing [R] Re-execute last executed command string G<n> 0..60000 0 0 = loop forever Mark the start of a repeat sequence g - - Loop depth = max 10 Mark the start of a repeat sequence M<n> 0..86400000 Milliseconds Delay command execution T - - No trailing [R] Hardstop initialisation required E.g. /1gP2000D2000G3R<CR> will trigger 3 back-and-forth 2000-step moves from the plunger. Initialisation commands Command Operand n range Default Operand Command description value description Z or Y - - - Initialise the plunger drive and do valve homing Plunger movement commands Command Operand n range Default Operand Command description value description A<n> or 0..3000 with N=0 - - Absolute position a<n> 0..24000 with N=1 P<n> or 0..3000 with N=0 - - Relative pickup p<n> 0..24000 with N=1 D<n> or d<n> 0..3000 with N=0 0..24000 with N=1 - - Relative dispense Valve commands Command Operand n range Default value Operand description O<n> 1..6 - Counterclockwise plug movement (valve seen from above) I<n> 1..6 - Clockwise plug movement (valve seen from above) Command description Move to valve port Move to valve port. Port numbering has been configured such that going to the next port number (e.g. the valve is on port 1 and moves to port 2) rotates the plug by 60 degrees only. E.g. /1M10000I2R<CR> will wait 10 seconds before moving the plug to port 2 in a clockwise direction. Web: www.amf.ch 4 of 7 25.01.2017

Set commands Command Operand n range Default operand Power up default Operand description Command description V<n> 5..1600-150 Peak speed Set peak speed (pulses/sec) S<n> 10..40-22 Cf. table below Set speed Speed code Value (pulses/sec) Seconds/stroke (N=0, N=1) 10 1600 1.885 11 1400 2.15 12 1200 2.5 13 1000 3 14 800 3.75 15 600 5 16 400 7.5 17 200 15 18 190 15.79 19 180 16.665 20 170 17.645 21 160 18.75 22 150 20 23 140 21.43 24 130 23.075 25 120 25 26 110 27.275 27 100 30 28 90 33.335 29 80 37.5 30 70 42.855 31 60 50 32 50 60 33 40 75 34 30 100 35 20 150 36 18 166.665 37 16 187.5 38 14 224.235 39 12 250 40 10 300 Web: www.amf.ch 5 of 7 25.01.2017

Report commands Setting the speed is a delicate process. Tubings of small inner diameter will act as restrictions for the flow and pushing liquids at high speed through such tubings will lead to high pressure in your microfluidic circuit. High pressure will increase the leakage in the circuit and could even block the pump as too much force would be required to dispense the syringe content. Finally yet importantly, high pressure can blow up the weakest part of a microfluidic setup. Therefore, we recommend choosing speeds according to a pressure estimation. These commands do not need the trailing R character. Command Description Q Current status? Report absolute plunger position?1 Report start speed?2 Report maximal speed?3 Report cutoff speed?4 Report actual position of plunger?6 Report valve position?10 or F Report command buffer status?12 Report number of backlash increments?13 Report status of input #1 (J5, Pin7)?14 Report status of input #2 (J5, Pin 8)?20 or # Report firmware checksum?23 or & Report firmware version?29 Same as Q (query, status and error bytes)?76 Report pump configuration * Report supply voltage (x0.1 V)?9000 Unique ID?9100 Detailed status of the pump?9200 Detailed status of the valve Web: www.amf.ch 6 of 7 25.01.2017

Error codes The pump immediately sends a response every time an instruction is sent to it. Only errors 2 and 3 can be found through this immediate response. The user must send the command Q to get the status in case of further errors. Error byte Bit 7 6 5 4 3 2 1 0 Value 0 1 Status bit 0 Error code Status bit value X = 0 X = 1 Description The pump will only accept report commands or terminate command (T) The pump is ready to accept new instruction Error byte ASCII symbol Error 7 6 5 4 3 2 1 0 If X = 0 If X = 1 Code Description 0 1 X 0 0 0 0 0 @ 0 No error 0 1 X 0 0 0 0 1 A a 1 Initialisation 0 1 X 0 0 0 1 0 B b 2 Invalid command 0 1 X 0 0 0 1 1 C c 3 Invalid operand 0 1 X 0 0 1 1 1 G g 7 Device not initialised 0 1 X 0 1 0 0 0 H h 8 Internal failure 0 1 X 0 1 0 0 1 I i 9 Plunger overload 0 1 X 0 1 0 1 0 J j 10 Valve overload 0 1 X 0 1 0 1 1 K k 11 Plunger move not allowed 0 1 X 0 1 1 0 0 L l 12 Internal failure 0 1 X 0 1 1 1 0 N n 14 A/D converter failure 0 1 X 0 1 1 1 1 O o 15 Command overflow Web: www.amf.ch 7 of 7 25.01.2017