Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Similar documents
Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Product and functional description

Product and functional description

Product and functional description

High-performance switching actuators

Product and functional description

Product and functional description

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Weather station GPS AP 257/61 Weather station AP 257/51

Weather station AP 257/51

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Push Button Interface UP 220D31

DELTA i-system wall switch single UP 221/2 5WG AB_2

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

DELTA profil wall switch, single UP 241/2 5WG AB_2

Product and Application Description

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Product and functional description

Operating voltage Maximum

Product and Applications Description

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

Push button UP 287, 4 - fold

584 5WG AB_1 DELTA

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

252F 5WG FB_1 DELTA

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016

Operating and mounting instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Product and Application Description

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

ABB i-bus KNX Blower/Fan Coil-Actuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

EAE KNX Switch Actuator

Extension module for lighting control

Use of the application program

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Power supply module, bus connection module

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 Controls:

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Operating Instructions

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

1-channel shutter actuator 6A UP Installation Instructions

ABB i-bus KNX Blower Actuator FCL/S x Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

Operating instructions. Switching amplifier DN0210 DN / / 2015

The LED display (1) turns green when the load is switched on.

Relay actuators & Status indicating modules

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

ABB i-bus. KNX JRA/S Blind/Roller Shutter Actuator with Binary Inputs Product Manual

Product and Function Description

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

UNIVERSAL DIMMER DIM02SA/500U

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

ABB i-bus KNX BCI/S Boiler/Chiller Interface

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Product manual. Mylos KNX 350w Dimmer 2CSYK1205C/S

Heating Circuit Controller

EAE KNX Room Control Unit Product Manual RCUXXYY

CC COMPACT DIP SWITCH

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Binary Inputs BE/S Product Manual

Room automation station

Operating instructions. Speed monitor D / / 2014

LUNA LUNA 111 top2 LUNA 112 top2 D GB F I E P , , Assembly and operating instructions Digital twilight switch

ETD-BL-1T-OFF-CC- 10S

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

PI-EX-ME-2NAM/COC-24VDC

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

RM35LM33MW liquid level control relay RM35-L V AC/DC

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Operating instructions. Standstill monitor A / / 2011

ABB i-bus KNX AC/S Application Controller

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

TXM1.8RB. TX-I/O Blinds module

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

COMPACT LED CONVERTERS 48 V

Transcription:

Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1 53-1DB51 5WG1 532-1DB51 5WG1 534-1DB51 12x AC 23V 5WG1 53-1DB61 5WG1 532-1DB61 5WG1 534-1DB61 Switching Actuators N53, 6AX 4-, 8- and 12-fold AC 23V Switching Actuators N532, 1AX 4-, 8- and 12-fold AC 23V Switching Actuators N534, 16/2AX 4-, 8- and 12-fold AC 23V Switching of capacitive, inductive and resistive loads Maintenance free terminals for connection and through-wiring of untreated single-core, stranded or multi-core conductors,.5... 2.5mm² conductor area Mechanical slide switches per output for checking the installation Functions when configured with ETS Comprehensive control, override and diagnostic functions per channel Control functions: Switching with status annunciation, logic gates, central switching, scene control, timer functions, night mode Override functions: Manual ON, Permanent OFF, Lock, nput monitoring Diagnostic functions: Counting of switching cycles and operating hours, status annunciation Control value input for analog values configurable as an alternative to the switching input Siemens AG DS3 Update: http://www.siemens.com/gamma-td Control Products and Systems Siemens AG 217 P.O. Box 1 9 53, D-939 Regensburg Subject to change without further notice July 217

Type overview Type Order number Description 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 Switching Actuator N53D31, 4 x AC 23 V, 6 AX (1A AC1) Switching Actuator N532D31, 4 x AC 23 V, 1AX (16A AC1) Switching Actuator N534D31, 4 x AC 23 V, 16/2AX 5WG1 53-1DB51 5WG1 532-1DB51 5WG1 534-1DB51 Switching Actuator N53D51, 8 x AC 23 V, 6 AX (1A AC1) Switching Actuator N532D51, 8 x AC 23 V, 1AX (16A AC1) Switching Actuator N534D51, 8 x AC 23 V, 16/2AX 5WG1 53-1DB61 5WG1 532-1DB61 5WG1 534-1DB61 Switching Actuator N53D61, 12 x AC 23 V, 6 AX (1A AC1) Switching Actuator N532D61, 12 x AC 23 V, 1AX (16A AC1) Switching Actuator N534D61, 12 x AC 23 V, 16/2AX Features The Switching Actuators N53D31, N532D31 and N534D31 can switch four individual groups of electrical loads via their four potential-free outputs. The Switching Actuators N53D51, N532D51 and N534D51 can switch eight individual groups of electrical loads via their eight potential-free outputs. The Switching Actuators N53D61, N532D61 and N534D61 can switch twelve individual groups of electrical loads via their twelve potential-free outputs. These devices all have the following features in common. The device is an N-system DN rail mounted device for mounting in distribution or control panels on 35 mm rails according to EC 6715. The bus connection of the device is done via the bus terminal block. The power supply of the electronics of the device is provided by the bus (i.e., it requires no additional power supply). Each actuator output has a potential-free relay with a switching position indicator. Apart from showing the switching state (when switching manually as well as when switching via the bus) it can be used to manually change the switching position using a tool. Each actuator output has one terminal each for mains power supply (rated contact voltage AC 23V) and for the switched load. The maintenance-free terminals are designed for connection and through-wiring of untreated singlecore, stranded or multi-core conductors,.5... 2.5mm². Stranded or multi-core conductors can be pushed into the terminals without crimping on ferrules. The terminals each have two connection points allowing e.g. through-wiring of the mains power supply from one output to the next. Each of the outputs (relays) can be assigned various tasks depending on the application program used, i.e. the switching actuator N 53x consists of the device (hardware) and its application programs (software). Application The Switching Actuators can switch resistive loads (e.g. electrical heating, incandescent lamps), inductive loads (e.g. motors, low voltage halogen lamps with magnetic transformer) or capacitive loads (e.g. low voltage halogen lamps with electronic transformer). The devices are applicable for switching of loads with high in-rush current peaks, especially for fluorescent lamp loads (AX) according to DN EN 6669-2-1. The permissible lamp loads are listed in section Technical Data. 2 / 12 Update: http://www.siemens.com/gamma-td DS3 Siemens AG Siemens AG 217 Control Products and Systems July 217 Subject to change without further notice P.O. Box 1 9 53, D-939 Regensburg

Functions when commissioned with ETS The switching actuators provide numerous control functions per actuator output. The base function is switching with status annunciation. Via ETS configuration the base function can be extended by control functions (logic, timers, scene control, central switching), override functions (Manual ON, Permanent OFF, blocking, forced control) up to diagnostic functions (counting of operating hours and switching cycles without or with threshold monitoring). The following schema shows the functions in a logic order. Send status value Control value 1 Switching Control value input 1 Logic operation 1 Logic operation 1 Diagnostic functions Override functions Control functions Logic operation 2 Logic operation 2 Central switching t t 8-bit scene 8-bit scene Flashing 1 Night mode 1 Day mode timer period Day mode timer Night mode timer Flashing Night mode timer period Override control 1 Override control 1 Status Override control 1 Override control 2 Override control 2 Status Override control 2 Override control 3 Override control 3 Status Override control 3 Override control 4 Override control 4 Status Override control 4 Override control 5 Override control 5 Status Override control 5 Forced control Forced control Status Forced control Override control 6 Override control 6 Status Override control 6 NO / NC contact Status Status switching Number of switching cycles Number of operating hours Status Number of switching cycles Status Number of operating hours Schematic design of a switching actuator channel Siemens AG DS3 Update: http://www.siemens.com/gamma-td Control Products and Systems Siemens AG 217 P.O. Box 1 9 53, D-939 Regensburg Subject to change without further notice July 217 3 / 12

Control functions n the following sections the range of control, override and diagnostic functions are each described. The new switching actuators provide automation of lighting or control of motors. The following control functions are available for this purpose: Switching input: control input for ON respectively OFF commands Control value input: A control value input with configurable thresholds for On and Off switching can be used as an alternative to a switching input. The control value input is a control input for an analog control value e.g. temperature, percent value, power, luminance and integer numbers. The control value input is transformed via an upper and a lower threshold into an ON respectively an OFF command. Alternatively available operating modes: o Normal operation o Timer operation o Flashing operation Logic operations (AND, OR, NAND, XOR, NOR, FLTER, TRGGER) Central switching 8-bit scene control Day/night operation Each output of the actuator can be individually set to one of these operating modes: o Normal operation o Timer operation o Flashing operation n the operation mode normal operation the timer functions for delayed On and Off switching and timer night mode operation are available. n the operation mode timer operation the functions timer day operation and timer night operation are available. n the operation mode Flashing the output is cyclically turned on and off with configurable on and off duty cycles. n timer day or night operation switching On of the output can be time limited (e.g. for cleaning lighting), if applicable with warning before switching off via off and on switching of the output (single flashing). Per output there is an integrated 8-bit scene control with each output assignable to up to 8 scenes. Override functions To realize special functions, there are override control functions, which have a higher priority than standard control functions. Per actuator output up to six different override functions (1 to 6) can be freely selected. The override control function 6 has the highest priority, the override function 1 the lowest. With the switching actuators, the forced control function always has second highest priority between the override functions with priority 5 and 6. For each one of the activated override functions one of the following functions can be chosen: o manual override ON o permanent OFF o blocking function o central override o user-defined override function For each actuator output this allows for flexible configuration of different priority dependent overrides. For the override functions a control value input can be used instead of a switching input. Override functions can be used to address special cases in room and building control like alarm or maintenance work. Diagnostic functions 4 / 12 The diagnostic functions support supervisory systems with their display, monitoring and archiving functions. For this purpose these diagnostic functions are available: Device function: The switching actuator cyclically sends a function signal allowing a supervisory system to monitor its function. Update: http://www.siemens.com/gamma-td DS3 Siemens AG Siemens AG 217 Control Products and Systems July 217 Subject to change without further notice P.O. Box 1 9 53, D-939 Regensburg

Status indication: Sending of the switching status can be activated per output. The current status can be read via the bus or transmitted cyclically. Status retrieval: For all outputs sending the current status can triggered via a central status retrieval object. With a single message visualization (e.g. P Control Center) can update its status information and display. Switching cycle counting with or without threshold monitoring: Counting of switching cycles can be activated per output. The number of switching cycles can be read via the bus. This allows for monitoring of the switching cycles and a switching cycle dependent maintenance. f the threshold monitoring is activated the device sends a signal onto the bus when the set threshold is reached. The exceedance of the threshold is automatically signaled respectively this can be sent as an email by the P Control Center or can be displayed by a warning light. Operating hour counting with or without threshold monitoring: Counting of operating hours can be activated per output. The number of operating hours can be read via the bus. This allows for monitoring of the operating hours and an operating hour dependent maintenance, e.g. if after 1, hours of operation lamps shall be replaced. f the threshold monitoring is activated the device sends a signal onto the bus when the set threshold is reached. The exceedance of the threshold is automatically signaled respectively this can be sent as an email by the P Control Center or can be displayed by a warning light. ETS version The application program already has been loaded in the factory. The device is configured and commissioned with Engineering Tool Software (ETS) version ETS v4 or higher. With the ETS (Engineering Tool Software) the specific parameters and addresses are assigned appropriately, and downloaded into the device. The device supports functions of ETS5 like fast downloading of the application program and further ETS5 configuration options. Behavior on bus voltage failure/recovery Building site function Factory default state Because the device electronics are powered by bus voltage a mains power failure only leads to a functional failure of the actuator if the bus voltage fails due to a failure of the mains voltage. For each actuator output the switching position of the relay on bus voltage failure can be individually configured to be Off, On, or with No change. On bus voltage failure the current switching status value and further values of each output are saved permanently for restoration on bus voltage recovery. On bus voltage recovery, the starting value of the switching object can be set to Off, On, last switching status or last received value. On bus voltage recovery the configured actions are executed and, if applicable, new status values are reported. The building site function provided ex-factory enables switching the building site lighting on and off via bus wall switches and actuators, even if these devices have not yet been commissioned with ETS. n the default factory state all channels (outputs) are set to the function switching for the building site function. Behavior on unloading the application program When the application program is unloaded with ETS the device does not function. Resetting the device to factory default settings A very long push of the programming button (> 2 s) effects a reset to factory settings. This is indicated by constant flashing for 8 seconds. All configuration settings are lost. The building site function is re-activated. Siemens AG DS3 Update: http://www.siemens.com/gamma-td Control Products and Systems Siemens AG 217 P.O. Box 1 9 53, D-939 Regensburg Subject to change without further notice July 217 5 / 12

Addressing mode A short push of learning button (< 2 s) enables the addressing mode. This is indicated by a continuously lit programming mode LED. A second push disables this mode. Note f the bus voltage is applied while the learning button is pressed, then the application in the device does not start. The application starts again, if the device is reset with ETS or if the bus voltage is reapplied without pressing the learning button. Technical design Location and Function of the Display and Operating Elements, nterfaces A1 A2 A3 A4 A5 Maintenance-free terminals for connection of load circuits Test contacts for voltage measuring Slide switch for display of the switching status and for manual operation - slide switch up: Relay contact opened - slide switch down: Relay contact closed Learning button for switching between normal operating mode and addressing mode and for receiving the physical address. With integrated LED for indicating normal operating mode (LED off) or addressing mode (LED on); returns to normal operating mode automatically after receiving the physical address. Bus connection block, screw-less A1 A2 A3 A4 A5 Technical data Power supply KNX bus voltage KNX bus current KNX power dissipation DC 24V (DC 21...3V) typ. 8mA (w/o switching), max. 2mA <.25W (KNX connection) Outputs Rated voltage AC 23/4V, 5/6 Hz Rated current per output N53 6AX (7µF) N532 1AX (14 µf) N534 16AX (2 µf) 2AX (2 µf) up to 35 C ambient temperature and adjacent outputs with no current Physical specifications Housing Dimensions nstallation Plastic DN rail mounted device in N-design width 4 MU (N53xD31), 8 MU (N53xD51), 12 MU (N53xD61) (1 MU = 18 mm) length 9 mm height 61 mm Top hat rail according to EC 6715-TH35 Weight N53D31 ca. 235 g N53D51 ca. 43 g 6 / 12 Update: http://www.siemens.com/gamma-td DS3 Siemens AG Siemens AG 217 Control Products and Systems July 217 Subject to change without further notice P.O. Box 1 9 53, D-939 Regensburg

Physical specifications N53D61 ca. 63 g N532D31 ca. 235 g N532D51 ca. 43 g N532D61 ca. 63 g N534D31 ca. 28 g N534D51 ca. 525 g N534D61 ca. 775 g Fire Load N53D31 ca. 5 MJ N53D51 ca. 8 MJ N53D61 ca. 12 MJ N532D31 ca. 5 MJ N532D51 ca. 8 MJ N532D61 ca. 12 MJ N534D31 ca. 6 MJ N534D51 ca. 1 MJ N534D61 ca. 14 MJ Environmental conditions Ambient operating temperature -5 C +45 C Storage temperature -2 C +7 C Transport temperature -25 C +7 C Relative humidity (non-condensing) 5 % 95 % Climatic conditions EN 5428 Environment and safety regulations Protection type (in accordance with EN 6529) Protection class (according to DN EN 6114) Degree of pollution (according to EC 6664-1) Overvoltage category (according to EC 6664-1) Electrical safety Bus Device complies with EMC-requirements Markings CE mark P2 P 2C in the operable area according to EC 61439-3 2 Safety Extra Low Voltage SELV DC 24 V EN 5428 EN 5428 KNX EB Complies with the EMC regulations (residential and functional buildings), low voltage regulations, and RoHS Directive Reliability Failure rate (at 4 C) N53D31 378 fit N53D51 598 ft N53D61 82 fit N532D31 378 fit N532D51 598 fit N532D61 82 fit N534D31 377 fit N534D51 597 fit N534D61 819 fit Siemens AG DS3 Update: http://www.siemens.com/gamma-td Control Products and Systems Siemens AG 217 P.O. Box 1 9 53, D-939 Regensburg Subject to change without further notice July 217 7 / 12

Lamp loads Type Contact current N 53D31 N 53D51 N 53D61 N 532D31 N 532D51 N 532D61 N 534D31 N 534D51 N 534D61 Rated current, AC [A] 6AX 1AX 16/2AX AC3-operation (cos φ =,45) [VA] 138 25 368 Maximum peak switch-on current t = 15µs [A] t = 25µs [A] t = 6µs [A] Contact voltage 4 32 2 4 32 2 Rated voltage, AC [V] 23 23 23 Service life Mechanical service life, Switching cycles in millions Electrical service life, Switching cycles in millions Power loss 6 48 3 1 1 1 1) 1) 1) Maximum power loss per device at rated power [W] 4 8 12 4 8 12 4 2) 8 2) 12 2) Switching capacities/load types, loads Resistive load [W] 23 25 368 Minimum switching capacity [V/mA] 12/1 12/1 12/1 DC switching capacity [V/A] 24/1 24/1 24/1 Maximum capacitive load[µf] 7 14 2 ncandescent lamps ncandescent lamps [W] 23 25 368 Halogen lamps 23 V [W] 23 25 368 LV halogen lamp with conventional transformer (inductive) [VA] T5/T8 fluorescent lamps 5 5 2 Uncorrected [VA] 138 23 368 Parallel corrected (at max. possible C) [W] 13 13 25 DUO-circuit [VA] 138 23 368 Compact fluorescent lamps Uncorrected [VA] 138 16 368 Parallel corrected (at max. possible C) [W] 11 11 3 1) on request 2) at 16A 8 / 12 Update: http://www.siemens.com/gamma-td DS3 Siemens AG Siemens AG 217 Control Products and Systems July 217 Subject to change without further notice P.O. Box 1 9 53, D-939 Regensburg

Notes The notes apply to all Switching Actuators N53x. nstallation notes The device may be used for permanent interior installations in dry locations within distribution boards or small casings with DN rail EN 6715-TH35. Safety DANGER The device must be mounted and commissioned by an authorized electrician. A safety disconnection of the device must be possible. The device must not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and Standards of the respective country are to be considered. Manual operation of the slider switches Manual operation of the slider switches is intended only for emergency operation or for testing during installation. No telegram is sent onto this bus and the changed switching position is not detected by the device. On bus voltage failure/recovery a manually switched relay is also set to the configured switching state. Assembly 23/4V AC EN 6715-TH35-7,5-15 Removal Siemens AG DS3 Update: http://www.siemens.com/gamma-td Control Products and Systems Siemens AG 217 P.O. Box 1 9 53, D-939 Regensburg Subject to change without further notice July 217 9 / 12

Connection 9... 1 mm Cu.5... 2.5 mm² 9... 1 mm.6 x 3.5 mm 2.5 mm² 9... 1 mm A Q = A Q MLFB 5WG1 53-1DB31 5WG1 53-1DB51 5WG1 53-1DB61 5WG1 532-1DB31 5WG1 532-1DB51 5WG1 532-1DB61 5WG1 534-1DB31 5WG1 534-1DB51 5WG1 534-1DB61 B / 16 A B / 16 A B / 16 A B / 2 A 5... 6 mm Cu.6....8 mm 5... 6 mm BLACK - RED + Disconnection.6 x 3.5 mm 1 / 12 Update: http://www.siemens.com/gamma-td DS3 Siemens AG Siemens AG 217 Control Products and Systems July 217 Subject to change without further notice P.O. Box 1 9 53, D-939 Regensburg

Commissioning < <2s 1 s PROG LED ON < <2s 1 s LED OFF > <2s 2 s RESET KNX 24VDC typ. SELV O - OFF A B C A B C - ON A B C A B C O1.2 mm / 1 Dimension Drawing Dimensions in mm 55 44 9 4 TE / 72 8 TE / 144 12 TE / 216 61 Product documentation Related documents like operation/installation instructions, application program description, product data base entry, additional software, product picture, CE declaration, et. Al. Can be found via this nternet address: http://www.siemens.com/gamma-td 11 / 12 Siemens AG DS3 Update: http://www.siemens.com/gamma-td Control Products and Systems Siemens AG 217 P.O. Box 1 9 53, D-939 Regensburg Subject to change without further notice July 217

Support General Notes The operating instructions must be handed over to the client. A faulty device shall be returned with a Return Good Note for Service provided by the appropriate Siemens sales office. f you have further questions concerning the product please contact our technical support. & +49 (911) 895-7222 6 +49 (911) 895-7223 ) support.automation@siemens.com http://www.siemens.com/automation/support-request Published by Siemens AG Control Products and Systems P. O. 1 9 53, D-939 Regensburg 217 Copyright Siemens AG Subject to change without further notice Update: http://www.siemens.com/gamma-td July 217 12 / 12