Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes

Similar documents
Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.1 release notes

Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.2.1 release notes

Configuration Guide -Server Connection-

HP StorageWorks Emulex Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux, VMware and Citrix operating systems release

HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-

HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

HP StorageWorks Emulex Adapters Release Notes

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes

The Contents and Structure of this Manual. This document is composed of the following four chapters.

HP StorageWorks Using the QLogic HBA driver for single-path or multi-path failover mode on Linux systems application notes

HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

Using Device-Mapper Multipath. Configuration and Administration 5.2

HP StorageWorks Emulex host bus adapters for x86 and x64 Linux and Windows systems release notes

The Contents and Structure of this Manual. This document is composed of the following three chapters.

1. Set up the storage to allow access to the LD(s) by the server following the NEC storage user guides.

Red Hat Enterprise Linux 5 DM Multipath. DM Multipath Configuration and Administration Edition 3

HP 3PAR StoreAll 9300 Gateway Storage Implementation Guide

Linux Host Utilities 6.2 Quick Start Guide

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)

HP StorageWorks QLogic fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems

HP StorageWorks QLogic host bus adapters for x86 and x64 Linux and Windows and x86 NetWare release notes

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux

サーバー製品 Linux 動作確認一覧表 システム構成図 2010 年 11 月 1 日

NEC Storage M series for SAP HANA Tailored Datacenter Integration Configuration and Best Practice Guide

Using Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2

HYPER-UNIFIED STORAGE. Nexsan Unity

iscsi Adapter Inbox Driver Update for Linux Kernel 2.6.x Table of Contents

HP BladeSystem Matrix Compatibility Chart

HP StorageWorks QLogic fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents

hp StorageWorks Using the QLogic Driver for Single-path or Multi-path Failover Mode on Linux Systems

HP Serviceguard for Linux Certification Matrix

Red Hat Enterprise Linux 7

Red Hat Enterprise Linux 4 DM Multipath. DM Multipath Configuration and Administration

Red Hat Enterprise Linux 7 DM Multipath

Hitachi Dynamic Link Manager (for Linux ) Release Notes

NEC Storage M series for SAP HANA Tailored Datacenter Integration

Hitachi Dynamic Link Manager (for Linux ) Release Notes

DtS Data Migration to the MSA1000

Red Hat Enterprise Linux 6

Oracle Validated Configuration with Cisco UCS, Nimble Storage, and Oracle Linux

HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes

v Release Notes

Fibre Channel Adapter and Converged Network Adapter Inbox Driver Update for Linux Kernel 2.6.x and 3.x. Readme. QLogic Corporation All rights reserved

v Release Notes

LINUX IO performance tuning for IBM System Storage

v Release Notes

The Host Server. Citrix XenServer Configuration Guide. May The authority on real-time data

Linux Multipathing Solutions: MPP vs. DM-RDAC

HP StorageWorks Continuous Access EVA 2.1 release notes update

QLogic QLA4010/QLA4010C/QLA4050/QLA4050C/ QLA4052C/QMC4052/QLE4060C/QLE4062C iscsi Driver for Linux Kernel 2.6.x.

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide

HP StorageWorks SmartStart EVA Storage 3.2 Release Notes

Tegile Best Practices for Oracle Databases

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

HP StorageWorks MPxIO for Sun Solaris application notes

HP StorageWorks MPxIO for Sun Solaris application notes

STORAGE CONFIGURATION BEST PRACTICES FOR SAP HANA TAILORED DATA CENTER INTEGRATION ON EMC VNX SERIES UNIFIED STORAGE SYSTEMS

The Host Server. Linux Configuration Guide. October 2017

Veritas Storage Foundation for HPE-OEM Solutions 6.1 Hardware Compatibility List

FC HBA Driver for Linux Kernel 2.6.x. Table of Contents

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide

DM-Multipath Guide. Version 8.2

Storage Updates for OpenVMS 8.4

Host and storage system rules

HP BladeSystem Matrix 6.0 Compatibility Chart

Release Notes. EMC PowerPath for Linux. Version 4.3. P/N Rev A09. June 7, 2005

The Host Server. Citrix XenServer Configuration Guide. November The Data Infrastructure Software Company

HP Serviceguard Solutions Storage Support Matrix (HPUX) Jan 13, 2015, Ver 02.60

HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system.

Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix

HP 3PAR Host Explorer MU1 Software User Guide

Release Notes P/N Rev A05

Storage Compatibility Guide for ESX Server 3.0

QuickSpecs. Models. HP StorageWorks 8Gb PCIe FC HBAs Overview

Tested By: Hewlett-Packard Test Date: Configuration Section Configuration

FUJITSU Storage ETERNUS Multipath Driver V2 (for Linux) Installation Information

High performance Oracle database workloads with the Dell Acceleration Appliance for Databases 2.0

HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment

HP StorageWorks Enterprise Virtual Array

HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 3.1A for Sun Solaris release notes

Software-defined Shared Application Acceleration

Configuring the MSA1000 for Linux or NetWare Environments

HP Supporting the HP ProLiant Storage Server Product Family.

v Release Notes

Windows Host Utilities Installation and Setup Guide

Overview. Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance. August By Tom Hanvey; update by Peter Brouwer

Storage / SAN Compatibility Guide For ESX Server 3.x

Notes on Using Red Hat Enterprise Linux AS (v.4 for EM64T)

Red Hat Enterprise Linux 5

Upgrading the MSA1000 for Enhanced Features

Red Hat Enterprise Linux 4 DM Multipath

FC Cookbook for HP Virtual Connect

HP StorageWorks Enterprise Virtual Array

Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix

VMware VMmark V1.1 Results

Transcription:

Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes Part number: AA-RWF9K-TE First edition: February 2010

Legal and notice information Copyright 2009-2010 Hewlett-Packard Development Company, L.P.

Overview This release notes discusses the recent product information about HP Device Mapper Multipath (HPDM Multipath) Enablement Kit for HP StorageWorks Disk Arrays v4.4.0. This incremental release is to provide enablement for HP StorageWorks Disk Arrays P2000FC and P2000FC/iSCSI. Device Mapper Multipath offers the following features: I/O failover and failback: Provides transparent failover and failback of I/Os by rerouting I/Os automatically to an alternative path when a path failure is sensed, and routing them back when the path is restored. Path grouping policies: Paths are coalesced based on the following path-grouping policies: Priority based path-grouping Provides priority to group paths based on Asymmetric Logical Unit Access (ALUA) state Provides static load balancing policy by assigning higher priority to the preferred path Multibus All paths are grouped under a single path group Group by serial Paths are grouped together based on controller serial number Failover only Provides failover without load balancing by grouping the paths into individual path groups I/O load balancing policies: Provides the following load balancing policies within a path group: Weighted round robin This round-robin algorithm routes rr_min_io number of I/Os on a selected path before switching to the next path. Least pending I/O path This determines the number of non-serviced requests pending on a path and selects the path which has the least number of pending requests for service. DM service time This is a service time oriented dynamic load balancer, which selects a path to complete the incoming I/O with the shortest time. Device name persistence: Device names are persistent across reboots and Storage Area Network (SAN) reconfigurations. Device Mapper also provides configurable device name aliasing feature for easier management. Persistent device settings: All the device settings such as load balancing policies, path grouping policies are persistent across reboots and SAN reconfigurations. Device exclusion: Provides device exclusion feature through blacklisting of devices. Path monitoring: Periodically monitors each path for status and enables faster failover and failback. Online device addition and deletion: Devices can be added to or deleted from Device Mapper (DM) Multipath without rebooting the server or disrupting other devices or applications. Management Utility: Provides Command Line Interface (CLI) to manage Multipath devices. Boot from SAN: Provides multipathing for operating system installation partitions on SAN devices. Cluster support: Provides multipathing in HP Serviceguard and SteelEye LifeKeeper clustering environment. Volume Manager support: Provides support for multipathing devices to be configured under Logical Volume Manager. Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes 3

NOTE: The following features are available only on SLES 11 operating system: Least pending I/O path DM service time For details on multipathing support for SAN Boot environment, see the Booting Linux x86 and x86_64 systems from a Storage Area Network with Device Mapper Multipath document available at: http://h18006.www1.hp.com/storage/networking/bootsan.html What's new HPDM Multipath 4.4.0 provides the following: Provides support for HP StorageWorks Disk Arrays P2000FC and P2000FC/iSCSI Provides support for Brocade PCIe Fibre Channel Host Bus Adapters NOTE: For more information on operating systems supported with HP StorageWorks Disk Arrays, see the SPOCK website: www.hp.com/storage/spock For more information on the inbox HBA driver parameters, see Setting up HPDM Multipath. Device Mapper Multipath support matrix Table 1 lists the hardware and software prerequisites for installing HPDM Multipath. Table 1 Hardware and software prerequisites System feature Operating system versions Host Bus Adapters (HBA) SAN Switches Supported hardware and software RHEL 4 Update 6 RHEL 4 Update 7 RHEL 4 Update 8 RHEL 5 Update 2 RHEL 5 Update 3 RHEL 5 Update 4 SLES 10 - SP2 SLES 10 - SP3 SLES 11 See http://h18006.www1.hp.com/storage/networking/index.html, http://h18004.www1.hp.com/products/servers/proliantstorage/adapters/index.html, and http://h20000.www2.hp.com/bizsupport/techsupport/driverdownload.jsp?lang=en& cc=us&prodnameid=3628653&taskid=135&prodtypeid=332283& prodseriesid=3628652&submit.y=2&submit.x=5&lang=en&cc=us 4

System feature Servers Supported arrays HBA drivers and Smart Array Controller drivers Supported hardware and software HP BladeSystem c-class Server Blades, ProLiant x86, ProLiant AMD64, ProLiant EM64T Servers, Integrity Servers EVA4000 (HSV200) XCS 5.110/6.200 or later EVA6000 (HSV200) XCS 5.110/6.200 or later EVA8000 (HSV210) XCS 5.110/6.200 or later EVA4100 (HSV200) XCS 6.200 or later EVA6100 (HSV200) XCS 6.200 or later EVA8100 (HSV210) XCS 6.200 or later EVA4400 (HSV300) XCS 0900 or later EVA6400 (HSV400) XCS 0950 or later EVA8400 (HSV450) XCS 0950 or later EVA iscsi Connectivity Option XP10000 fw rev 50-07-30-00/00 or later XP12000 fw rev 50-09-34-00/00 or later XP20000 fw rev 60-02-04-00/00 or later XP24000 fw rev 60-02-04-00/00 or later MSA2000 Storage product family (MSA2012fc/MSA2212fc) fw rev J200P19 or later MSA2012i fw rev J210R10 or later MSA2012sa fw rev J300P13 or later (MSA2312fc/MSA2324fc) fw rev M100R18 or later MSA2312sa/MSA2324sa fw rev M110R20 or later MSA2312i/MSA2324i fw rev M110R20 or later P2000 fc fw rev TS100R017 or later P2000 fc/iscsi fw TS100R017 rev or later HP SC08Ge Host Bus Adapter: 4.00.13.04-2 or later (for RHEL 5/SLES 10), 3.12.14.00-2 or later (for RHEL 4) available at: http://h20000.www2.hp.com/bizsupport/techsupport/driverdownload.jsp?lang=en& cc=us&prodnameid=3759720&taskid=135&prodtypeid=329290& prodseriesid=3759718&lang=en&cc=us Emulex: 8.0.16.40-11or later (for RHEL 4 U8), 8.0.16.40 or later (for /RHEL4 U7), 8.2.0.22 or later for (SLES 10 SP2 / RHEL 5 U2), 8.0.16.32 or later (for RHEL 4 U6) available at: http://h18006.www1.hp.com/products/storageworks/4gbpciehba/ index.html Qlogic: 8.02.23-1or later (for RHEL 4 U8), 8.02.11 or later (for SLES 10 SP2/RHEL 5 U2/RHEL4 U7), 8.01.07.25 or later (for RHEL 4 U6) available at: http:// h18006.www1.hp.com/products/storageworks/fca2214/index.html Brocade: 1.1.0.10 available at: http://h20180.www2.hp.com/apps/lookup?h_pagetype=s-001&h_lang=en& h_client=s-s-r2515-1&h_cc=us&h_query=hp+storageworks+pcie+4gb+host+bus+adapter HP Smart Array P700m Controller: http://h20000.www2.hp.com/bizsupport/techsupport/driverdownload.jsp?lang=en& cc=us&prodnameid=3628653&taskid=135&prodtypeid=332283& prodseriesid=3628652&submit.y=2&submit.x=5&lang=en&cc=us RHEL 5 U3/RHEL 5 U4/SLES 10 SP3/SLES 11 FC HBA drivers Inbox drivers Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes 5

NOTE: For more information on configuring iscsi parameters, see Configuring iscsi parameters. Device Mapper Multipath does not support coexistence with other multipath products. Device Mapper Multipath does not support Active-Passive Storage Arrays. HPDM Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 does not support SAS and CCISS devices on SLES 10 SP3. On SLES 11, Device Mapper Multipath for iscsi devices is supported with kernel version 2.6.27.37-0.1.1 or later Brocade HBAs are supported on RHEL5U3, RHEL5U4, SLES10 SP2 and SLES11 Installing Device Mapper Multipath tools Ensure the following RPMs bundled with the operating system distributions are installed on the system: For RHEL 4 Update 7: device-mapper-1.02.25-2.el4 or later device-mapper-multipath-0.4.5-31.el4 or later For RHEL 4 Update 8: device-mapper-1.02.28-2.el4 or later device-mapper-multipath-0.4.5-35.el4 or later For RHEL 5 Update 2: device-mapper-1.02.24-1.el5 or later device-mapper-multipath-0.4.7-17.el5 or later For RHEL 5 Update 3: device-mapper-1.02.28-2.el5 or later device-mapper-multipath-0.4.7-23.el5 or later For RHEL 5 Update 4: device-mapper-multipath-0.4.7-30.el5 or later device-mapper-1.02.32-1.el5 or later For SLES 10 SP2: device-mapper-1.02.13-6.14 or later device-mapper-devel-1.02.13-6.14 or later multipath-tools-0.4.7-34.43 or later For SLES 10 SP3: device-mapper-1.02.13-6.14 or later device-mapper-devel-1.02.13-6.14 or later multipath-tools-0.4.7-34.50.10 or later For SLES 11: device-mapper-1.02.27-8.6 or later multipath-tools-0.4.8-40.4.1 or later 6

Installing HPDM Multipath Enablement kit 4.4.0 To install HPDM Multipath 4.4.0, complete the following steps: 1. Download the HPDM Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 available at: http://www.hp.com/go/devicemapper. 2. Log in as root to the host system. 3. Copy the installation tar package to a temporary directory (for example, /tmp/hpdmmultipath). 4. Unbundle the package by executing the following commands: #cd /tmp/hpdmmultipath #tar -xvzf HPDMmultipath-4.4.0.tar.gz #cd HPDMmultipath-4.4.0 5. Verify that the directory contains the following files and folders: INSTALL README.txt COPYING bin SRPMS conf docs 6. To install HPDM Multipath 4.4.0, execute the following command: #./INSTALL Configuring Device Mapper Multipath to enable HP arrays This section describes the following: Recommended device parameter values Setting up HPDM Multipath SAN configuration supported by DM Multipath Recommended device parameter values To enable HP arrays, edit /etc/multipath.conf file by adding the following under devices section: For MSA2012fc/MSA2212fc/MSA2012i device { Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes 7

vendor "HP" product "MSA2[02]12fc MSA2012i" "/sbin/scsi_id -g -u -s /block/%n" hardware_handler "0" path_selector "round-robin 0" path_grouping_policy multibus failback immediate rr_weight uniform no_path_retry 18 rr_min_io 100 path_checker tur } For EVA4x00/EVA6x00/EVA8x00 device { } vendor "HP product "HSV2[01]0 HSV300 HSV4[05]0" "/sbin/scsi_id -g -u -s /block/%n" prio_callout "/sbin/mpath_prio_alua /dev/%n" hardware_handler "0" path_selector "round-robin 0" path_grouping_policy group_by_prio failback immediate rr_weight uniform no_path_retry 18 rr_min_io 100 path_checker tur For HP P2000 FC / P2000 FC/iSCSI device { vendor product path_grouping_policy path_checker path_selector prio_callout rr_weight failback hardware_handler no_path_retry rr_min_io "HP" "P2000 G3 FC P2000G3 FC/iSCSI" group_by_prio "/sbin/scsi_id -g -u -s /block/%n" tur "round-robin 0" "/sbin/mpath_prio_alua /dev/%n" uniform immediate "0" 18 100 } For MSA2012sa/MSA2312sa/MSA2324sa 8

device { vendor "HP" product "MSA2012sa MSA2312sa MSA2324sa" "/sbin/hp_scsi_id -g -u -n -s /block/%n" prio_callout "/sbin/mpath_prio_alua /dev/%n" hardware_handler "0" path_selector "round-robin 0" path_grouping_policy group_by_prio failback immediate rr_weight uniform no_path_retry 18 rr_min_io 100 path_checker tur } For XP device { vendor "HP" product "OPEN-.*" "/sbin/scsi_id -g -u -s /block/%n" hardware_handler "0" path_selector "round-robin 0" path_grouping_policy multibus failback immediate rr_weight uniform no_path_retry 18 rr_min_io 1000 path_checker tur } For MSA2312fc/MSA2324fc/MSA2312i/MSA2324i device { } vendor "HP" product "MSA2312fc MSA2324fc MSA2312i MSA2324i" "/sbin/scsi_id -g -u -s /block/%n" hardware_handler "0" path_selector "round-robin 0" prio_callout "/sbin/mpath_prio_alua /dev/%n" path_grouping_policy group_by_prio failback immediate rr_weight uniform no_path_retry 18 rr_min_io 100 path_checker tur Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes 9

NOTE: For SLES 11, in the device section, replace /sbin/scsi_id -g -u -s /block/%n with /lib/udev/scsi_id -g -u /dev/%n For SLES 10 SP2/SLES 10 SP3/RHEL 5 U4, in the device section for MSA2012sa, MSA2312sa, and MSA2324sa, replace /sbin/hp_scsi_id -g -u -n -s /block/%n with /sbin/scsi_id -g -u -n -s /block/%n For SLES 10 SP2/SLES 10 SP3/SLES 11, in the device section, replace prio_callout /sbin/mpath_prio_alua %n with prio alua In XP arrays, there are different LUNs, such as OPEN-<x>, 3390-3A, 3390-3B, OP- C:3390-3C, 3380KA, 3380-KB, and OP-C:3380-KC where x = {3,8,9,K,T,E,V}. The product strings for XP LUNs are based on these emulation types. A new device section must be added for each emulation type, because each product string requires a new device subsection. OPEN-* is sufficient for the product string for all the XP LUNs with different OPEN emulations because, regular expressions are supported in the /etc/multipath.conf file. For more information on editing /etc/multipath.conf file, see the Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays Installation and Reference Guide. You can find this document on the Manuals page of Multi-path Device Mapper for Linux Software, which is accessible at http://www.hp.com/go/devicemapper. Setting up HPDM Multipath Setting up HPDM Multipath includes configuring HBA and iscsi initiator parameters for multipathed environment. This involves the following: Configuring QLogic HBA parameters Configuring Emulex HBA parameters Configuring iscsi parameters Configuring mptsas parameters Configuring Brocade HBA parameters 10

Configuring QLogic HBA parameters To configure the QLogic HBA parameters for QLogic 2xxx family of HBAs, complete the following steps: 1. Edit the /etc/modprobe.conf file in RHEL hosts and /etc/modprobe.conf.local file in SLES hosts with the following values: For operating systems using the native Qlogic drivers, options qla2xxx ql2xmaxqdepth=16 qlport_down_retry=10 ql2xloginretrycount=30 For other operating systems using the HP Qlogic drivers, options qla2xxx ql2xmaxqdepth=16 qlport_down_retry=10 ql2xloginretrycount=30 ql2xfailover=0 ql2xlbtype=0 ql2xautorestore=0x00 ConfigRequired=0 2. Rebuild the initrd by executing the following commands: For operating systems using the native Qlogic drivers, complete the following steps: a. Backup the existing initrd image by executing the following command: #mv /boot/initrd-<version no.>.img /boot/initrd-<version no.>.img.old b. Make a new initrd image by executing the following command: For SLES 10/SLES 11 operating systems: mkinitrd -k <kernal> -i <initrd> For other operating systems: #mkinitrd /boot/initrd-<version no.>.img `uname -r` c. Edit the value for default parameter in /boot/grub/menu.lst file to boot with the new initrd image. For other operating systems using the HP Qlogic drivers, /opt/hp/src/hp_qla2x00src/make_initrd 3. Reboot the host. Configuring Emulex HBA parameters To configure the Emulex HBA parameters, complete the following steps: 1. For Emulex lpfc family of HBAs: In RHEL 4 hosts, edit the /etc/modprobe.conf file with the following values: options lpfc lpfc_nodev_tmo=14 lpfc_lun_queue_depth=16 lpfc_discovery_threads=32 In SLES 10/SLES 11 hosts, edit the /etc/modprobe.conf.local file with the following values: options lpfc lpfc_nodev_tmo=14 lpfc_lun_queue_depth=16 lpfc_discovery_threads=32 In RHEL 5 hosts, edit the /etc/modprobe.conf file with the following values: options lpfc lpfc_nodev_tmo=14 lpfc_lun_queue_depth=16 lpfc_discovery_threads=32 2. Rebuild the initrd by executing the following commands: For operating systems using the native Emulex drivers, complete the following steps: a. Backup the existing initrd image by executing the following command: Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes 11

#mv /boot/initrd-<version no.>.img /boot/initrd-<version no.>.img.old b. Make a new initrd image by executing the following command: For SLES 10/SLES 11 operating systems: #mkinitrd -k <kernal> -i <initrd> For other operating systems: #mkinitrd /boot/initrd-<version no.>.img `uname -r` c. Edit the value for default parameter in /boot/grub/menu.lst file to boot with the new initrd image. For other operating systems using the HP Emulex drivers, execute the following command: /opt/hp/hp-lpfc/make_initrd 3. Reboot the host. Configuring iscsi parameters To configure the iscsi parameters, complete the following steps: 1. Update the iscsi configuration file In RHEL 5, SLES 10, and SLES 11 hosts, edit the /etc/iscsi/iscsid.conf file with the following value: node.session.timeo.replacement_timeout=15 node.startup=automatic In RHEL 4 hosts, edit the /etc/iscsi.conf file with the following value: ConnFailTimeout=15 2. Restart the iscsi service by executing the following command: In RHEL 4/RHEL 5 hosts, #/etc/init.d/iscsi restart In SLES 10/SLES 11 hosts, #/etc/init.d/open-iscsi restart Configuring mptsas parameters To configure the mptsas parameters for RHEL 5 and SLES hosts, complete the following steps: 1. Edit the /etc/modprobe.conf file in RHEL 5 hosts and /etc/modprobe.conf.local file in SLES hosts with the following values: options mptsas mpt_cmd_retry_count=10 mpt_disable_hotplug_remove=1 2. Rebuild the initrd by executing the following commands: a. Backup the existing initrd image by executing the following command: #mv /boot/<initrd-version no.>.img /boot/<initrd-version no.>.img.old b. Make a new initrd image by executing the following command: For SLES 10 operating systems: #mkinitrd -k <kernal> -i <initrd> For RHEL operating systems: #mkinitrd /boot/<initrd-version no.>.img 'uname -r' 12

c. Edit the value for default parameter in /boot/grub/menu.lst file to boot with the new initrd image. Configuring Brocade HBA parameters To configure the Brocade HBA parameters for RHEL 5 and SLES hosts, set the time out value by executing the following command: # bcu fcpim --mpiomode <port_id> off 14 SAN configuration supported by DM Multipath Table 2 lists the maximum SAN configuration supported by DM Multipath. Table 2 Maximum SAN configuration supported by DM Multipath Maximum number of LUNs supported Maximum number of paths per LUN Maximum number of HBAs Total number of SAN devices 512 32 8 2048 NOTE: If the total number of LUNs is 512, each LUN can have 4 paths which leads to 2048 (512*4) devices. Maximum SAN configuration supported by DM Multipath is only on SLES 11 operating systems. Known issues Following are the known issues in the HPDM Multipath 4.4.0 release: multipath commands may take longer time to execute on heavily loaded servers or under path failure conditions. Blacklisting the multipath device in the /etc/multipath.conf file and restarting the multipath service may not remove the device on RHEL 4 distributions. Execute the following command to remove the blacklisted device: # multipath -f <device> Using fdisk command to create partitions may fail to create Multipath device for the partition device. It is recommended to use parted command to create partitions for the device. Multipath -l command may not reflect the correct path status for Logical Units presented from MSA2xxxsa array when paths fail or are restored under heavy load conditions. To refresh the path status, execute the # multipath -v0 command. multipathd daemon crashes on systems configured with device paths more than the system open file limits (default system open file limit =1024). It is recommended to change the system open file limits by using either the 'max_fds' parameter in the /etc/multipath.conf file or by using the ulimit -n command and restart the multipathd demon. Multipath devices may not be created for Logical Units when the system disks or internal controllers are cciss devices. It is recommended to blacklist these devices in the /etc/multipath.conf file and restart the multipathd daemon. Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes 13

If an existing LUN is deleted or unpresented from RHEL host, a DM multipath device with the invalid WWN may be created which cannot be used and will be removed after the system reboots. For LUNs greater than 2TB in RHEL 4 operating systems, DM multipath devices may not be created with appropriate size. On RHEL 4 operating systems with large number of iscsi devices, not all multipath devices may get created after a reboot. It is recommended to increase the ESTABLISHTIMEOUT value in the /etc/sysconfig/iscsi file depending on the number of LUNs, or run the multipath -v0 command after the reboot. On SLES 11 operating systems: Multipath may not always activate all partitions on reboot. The multipathd daemon may fail to stop immediately after it is started in large SAN configurations. The multipathd daemon may consume more memory in large SAN configurations. 14