LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Similar documents
LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

Laurel Electronics Customer Price List

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

Digital Indicator Solutions

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

Product Description. Contents. Fusion Series. New Information December 2003

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

NF760 Batch Controller

Amplifiers, Counters, Timers & Controls

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Trident and Trident X2 Digital Process and Temperature Panel Meter

7511 / / / 711 / / 731 / Preset 27

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Omega and Red Lion team-up!

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Universal counter UZ 9648 Counting - length measurement - metering - positioning

Energy Management Modular Energy meters Type EM2-96

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Simplified information where and how you want it.

User friendly and easy to program

Displays Transducers. Displays and transducers

GFC114. Low Power Flow Computer FEATURES

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Programming and Installation Manual

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

LGR-5325 Specifications

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

DI-942MB. Frequency/Counter Module. Two Frequency or Pulse Waveform Inputs

MPV. Process Panel Display. Dual-Line Rate and Total

895/896M Frequency Output Math Modules

LGR-5327 Specifications

Zelio Count - Counters RC87610

PD765 TRIDENT. Trident Series Process & Temperature Meters.

RS-485 I/O Modules: ADAM-4000

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

SPECIFICATIONS SPECIFICATIONS. Input VDC. NEMA 4X/IP65 front VDC option. Temp SPECIFICATIONS

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

L40 UNIVERSAL ANALOG INPUT DIGITAL PANEL METER OWNERS MANUAL

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Counting On Your Process Preset Counters

02/11/2015

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

RS 485 Mini Modbus 1AO

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters

Characteristics and functioning

PD765 TRIDENT. Trident Series Process & Temperature Meters.

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DPM-3. Transducer Techniques DIGITAL PANEL MOUNT METER PLUG AND PLAY IEEE COMPLIANT OPERATOR MANUAL

EDX-10 Series. Compact Recording System

Process displays For current and voltage

USB-1616FS. Analog Input and Digital I/O. Specifications

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

USB-1602HS-2AO Specifications

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

CATALOG SHORT FORM. Digital Indicators & Controllers. th ANNIVERSARY PRECISION DIGITAL CORPORATION Since 1974

LAUREATE SERIES 2 DIGITAL PANEL METER OWNERS MANUAL

NF770 Temperature Compensation Liquid Flow Computer

Temperature Measurement

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i.

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input with Loop Power 7B35

Veeder-Root brand Series C628 Rate Meter (C628-4XXX)

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TALON Network Manager- 2 & 6 Express

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers. Batch control SERIES. Precision Digital Corporation

Transcription:

Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile RAM Inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mv, or AC inputs up to 250 Vac. Up counting from zero to preset value using positive scale factor Down counting from preset to zero using negative scale factor Universal AC power, 85-264 Vac Isolated 5, 10 or 24 Vdc excitation supply to power sensors NEMA 4X, 1/8 DIN case Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter Optional relay outputs: dual or quad relays, contact or solid state Optional isolated analog output: 4-20 ma, 0-20 ma, 0-10V, -10 to +10V Optional low voltage power: 10-48 Vdc or 12-32 Vac Optional Extended Counter: all capabilities of Standard counter, plus - Channel A total and Channel B rate simultaneously - Up/down counting on Ch A, using Ch B to control count direction - Counting on Ch A, using Ch B to inhibit counting - Arithmetic functions A+B, A-B, AxB, A/B, A/B-1 (draw) The Laureate dual-channel up or down totalizer is a basic operating mode of the Laureate counter with the FR dual-channel signal conditioner board. Each channel (A or B) may be independently set up and scaled to count up from zero (or other value) to a preset limit, or to count down from a preset value to zero (or other limit). Countdown operation is set up by entering a negative scale factor. The six-digit counter display is capable of displaying any value from -999,999 to 999,999 with a programmable decimal point. Scaling allows direct readout in engineering units, such as gallons or cubic feet based on counts from a turbine flow meter, or the count of cans based on the count of six-packs. The displayed channel (A or B) is selected via a front panel pushbutton. The totals are stored in non-volatile memory so as to be retained in the absence of power. Dual or quad AC/DC relays can add on/off control capability tied to totals A and B. An optional Extended counter version provides capabilities beyond those of the Standard counter: Rate and total simultaneously. Channel A can display total while Channel B displays rate. The selection of A or B for display is via a front panel pushbutton. This mode is ideal for flow applications. Up/down counting. Channel A can serve as an up/down counter, where the count direction is dynamically changed by applying a signal to Channel B. For instance, Channel A can count and scale pulses from a turbine flow meter, while Channel B inputs the direction of flow. This allows total volume to be tracked in case of reversible flow. Totalizing with external inhibit. Totalizing by Channel A can be temporarily inhibited by applying a signal to Channel B. For instance, 60 Hz AC pulses can be counted by Channel A and be scaled to display elapsed hours. A signal can be applied to Channel B to start or stop pulse counting when a process is in operation. Custom curve linearization. Exceptionally accurate custom curve linearization is achievable, for example to linearize the low end of turbine flow meters. For setup, up to 180 data points can be input into a spreadsheet or text file by the user. The computer then calculates spline fit segments, which are downloaded into the meter via RS-232. The linearized rate can then be totalized by the Extended counter. Arithmetic functions. The Extended counter makes arithmetic functions available, namely A+B, A-B, AxB, A/B and A/B-1. These solve many applications. For instance, A+B allows two input flows to be summed for total volume, while A-B allows outflow to be subtracted from inflow for net volume. A/B allows the mixing of ingredients in a specified ratio. By monitoring and alarming the A/B volume ratio, ingredient B can be added to A until the proper ratio is achieved. Inputs to the FR dual-channel signal conditioner can be proximity switches with PNP or NPN output, TTL or CMOS logic, magnetic pickups, contact closures, low-level outputs from turbine flow meters down to 12 mv, and high-level AC line inputs up to 250 Vac. A built-in isolated 5, 10, or 24 Vdc excitation supply can power proximity switches and other sensors, thus eliminating the need for an external power supply. Designed for system use. Optional plug-in boards include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A builtin isolated 5, 10, or 24 Vdc excitation supply can power transducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 1

Specifications Display Readout Display Range Zero Adjust Span Adjust Indicators 6 LED digits, 7-segment, 14.2 mm (.56"), red or green. -999999 to +999999, XXXXEX notation beyond 999999-999999 to +999999 0 to 999999 Four LED lamps Inputs Types Signal Ground Channel A Frequency Channel B Frequency Minimum Signal Maximum Signal Noise Filter Contact Debounce AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups. Common ground for channels A & B 0.005 Hz to 1 MHz 0.005 Hz to 250 khz Nine ranges from (-12 to +12 mv) to (+1.25 to +2.1V) 250 Vac 1 MHz, 30 khz, 250 Hz (selectable) 0, 3, 50 ms (selectable) Update Rate Freq. Technique Conversion Time Gate Time Time Before Zero Out Inverse period Gate time + 30 ms+ 0-2 signal periods Selectable 10 ms to 199.99 s Selectable 10 ms to 199.99 s Accuracy Time Base Span Tempco Long-term Drift Crystal calibrated to ±2 ppm ± 1 ppm/ C (typ) ± 5 ppm/year Power Voltage, standard Voltage, optional Power frequency Power consumption (typical, base meter) Power isolation 85-264 Vac or 90-300 Vdc 12-32 Vac or 10-48 Vdc DC or 47-63 Hz 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc Excitation Output (standard) 5 Vdc 10 Vdc 24 Vdc Output 5 Vdc ± 5%, 100 ma 10 Vdc ± 5%, 120 ma 24 Vdc ± 5%, 50 ma 50 Vdc to meter ground Analog Output (optional) Output Levels Current compliance Voltage compliance Scaling Resolution 4-20 ma, 0-20 ma, 0-10V, -10 to +10V (single-output option) 4-20 ma, 0-20 ma, 0-10V (dual-output option) 2 ma at 10V ( > 5 kω load) 12V at 20 ma ( < 600Ω load) Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale) (dual analog outputs share the same ground) Relay Outputs (optional) Relay Types Current Ratings Output common 2 Form C contact relays or 4 Form A contact relays (NO) 2 or 4 Form A, AC/DC solid state relays (NO) 8A at 250 Vac or 24 Vdc for contact relays 120 ma at 140 Vac or 180 Vdc for solid state relays Isolated commons for dual relays or each pair of quad relays LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 2

Serial Data I/O (optional) Board Selections Protocols Data Rates Digital Addresses Ethernet, Ethernet-to-RS485 server, USB, USB-to-RS485 server, RS485 (dual RJ11), RS485 Modbus (dual RJ45), RS232, Modbus RTU, Modbus ASCII, Laurel ASCII protocol 300 to 19200 baud 247 (Modbus), 31 (Laurel ASCII). Environmental Operating Temperature Storage Temperature Relative Humidity Protection 0 C to 55 C -40 C to 85 C 95% at 40 C, non-condensing NEMA-4X (IP-65) when panel mounted Electrical Connections Mechanical Application Examples Up/Down Totalizing Up/down totalizing is provided by a mode of the Extended counter where pulses are either added or subtracted on Channel A based on a direction input on Channel B. The counter can also be programmed so that counting by Channel A is inhibited by an input on Channel B. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 3

Combining Two Totals A+B, A-B and A/B arithmetic functions are available with the Extended counter. A+B sums both totals, while A-B subtracts the outflow total from inflow total. The A/B ratio applied to total helps assure the proper mixing of components. Controller setup and monitoring of the mixing operation are facilitated by optional serial communications. RS-485 allows a single data line to handle multiple controllers. Up or Down Counting with Preset A single Laureate dual-channel counter will handle two repetitive fill operations by counting from zero up to a preset, or down from a preset to zero. A dual setpoint relay board is required. Machine ON Time and Utilization An easy way to measure the ON time of machines is to count AC line cycles and scale the total to hours. To display machine utilization or duty cycle in percent, use the Extended counter. Connect Channel A to switched AC and Channel B to the AC line, and have the counter display the A/B ratio with a 100 multiplier. Total and Rate Simultaneously The Extended version of the Laureate dual channel counter can display scaled rate or total for the same channel at the push of a button, and alarm both the rate and total. The Extended version can also do curve linearization, thereby extending the working range and accuracy of flow transducers. System-level Capabilities The Laureate dual channel totalizer can independently scale, display and alarm two totals, and the totals plus alarm data can be transmitted via RS-232 or RS-485. The displayed totals can also be transmitted as an isolated 4-20 ma or 0-10V analog output. The Extended version can further display and transmit arithmetic combinations of the two totals. LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 4

Ordering Guide Create a model number in this format: L50000FR, IPC Main Board L5 Standard Main Board, Green LEDs L6 Standard Main Board, Red LEDs L7 Extended Main Board, Green LEDs L8 Extended Main Board, Red LEDs The Standard Main Board handles up or down totalizing as well as frequency, rate, period, square root of rate, stopwatch operation, and periodic time interval. The Extended Main Board handles the above plus simultaneous rate and total, stopwatch, arithmetic functions, phase, batching, and custom curve linearization. Power Relay Output Analog Output Digital Interface Input Type 0 Isolated 85-264 Vac 1 Isolated 12-32 Vac or 10-48 Vdc 1 Two 8A Contact Relays 2 Two 120 ma Solid State Relays 3 Four 8A Contact Relays 4 Four 120 ma Solid State Relays 1 Single isolated 4-20 ma, 0-20 ma, 0-10V, -10 to +10V 2 Dual isolated 4-20 ma, 0-20 ma, 0-10V 1 RS232 2 RS485 (dual RJ11 connectors) 4 RS485 Modbus (dual RJ45 connectors) 5 USB 6 USB-to-RS485 converter 7 Ethernet 8 Ethernet-to-RS485 converter FR Dual-Channel Pulse Input Signal Conditioner Add-on Options CBL01 RJ11-to-DB9 cable. RJ11 to DB9. Connects RS232 ports of meter and PC. CBL02 USB-to-DB9 adapter cable. Combination of CBL02 and CBL01 connects meter RS232 port to PC USB port. CBL03-1 6-wire data cable, RJ11 to RJ11, 1 ft. Used to daisy chain meters via RS485. CBL03-7 6-wire data cable, RJ11 to RJ11, 7 ft. Used to daisy chain meters via RS485. CBL05 CBL06 CASE1 CASE2 IPC BOX1 BOX2 BL NL USB cable, A-B. Connects USB ports of meter and PC. USB to RS485 adapter cable, half duplex, RJ11 to USB. Connects meter RS485 port to PC USB port. Benchtop laboratory case for one 1/8 DIN meter Benchtop laboratory case for two 1/8 DIN meters Splash-proof cover NEMA-4 Enclosure NEMA-4 enclosure plus IPC Blank Lens without button pads Meter lens without button pads or Laurel logo LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA Tel 714-434-6131 www.laurels.com 5