HPE Port and 48-Port Switches Quick Setup Guide

Similar documents
Aruba G/48G Switch Quick Setup Guide and Safety/Regulatory Information

Aruba JL311A Cable Guard Installation Instructions

Aruba 2930F 24G/48G Switch Quick Setup Guide and Safety/Regulatory Information

Aruba 2930M Switches Quick Setup Guide and Safety/Regulatory Information

Installation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies. PoE. Power over Ethernet Devices

HP PS1810 Switch HP PS1810-8G (J9833A) HP PS G (J9834A) Installation and Getting Started Guide. Power over Ethernet PD

ProCurve 2910al Switches

HP ProCurve Switch 2600 Series. Installation and Getting Started Guide. PoE. Power over Ethernet Devices

HP V1410 Switch Series

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4450GTX-HT- PWR+

installation and getting started guide hp procurve series 5300xl switches

ProCurve Series 3500yl and 6200yl Switches

HPE OfficeConnect 1920S Switch Series Installation and Getting Started Guide

PHYSICAL INTERFACES 5406R

Installation Job Aid for Ethernet Routing Switch 3600 Series

QuickSpecs. Models. Features and Benefits Connectivity. HP ProCurve Switch 1800 Series. Overview. Retired. HP ProCurve Switch G

Installation and Getting Started Guide

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

JG962A Datasheet. Overview. Quick Spec. Product Details

HP ProCurve Switch 1800 Series

HP V1700 Switch Series

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

ProCurve Switch 1400 Series

D-Link Switch User Manual. Table of Contents

QuickSpecs. Models HP V1810-8G Switch

Modular 8-Port Mid-span Power over Ethernet Injector

Quick Start Guide. C-100 Series Switches

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

Numerics INDEX. cables caution 1-19 cabling

Installation Job Aid for Ethernet Routing Switch 5900 Series

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Switch Installation. Preparing for Installation. Safety Warnings

Aruba 2930F Switch Series Installation and Getting Started Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

QUICK START GUIDE 7000 SERIES DEVICES. 3D7010/7020/7030 (Chassis: CHRY-1U-AC) 3D7115/7125, AMP7150 (Chassis: GERY-1U-4C8S-AC)

SW-UNM-24FE2GC-24POE 24 Fast Ethernet Ports PoE + 2 Giga Combo User Manual Ver 1.1

* * Agilent Power Distribution Unit (PDU) Installation Guide

24 RJ-45 autosensing 10/100 ports (IEEE Type 10BASE-T, IEEE 802.3u Type 100BASE-TX) Duplex: half or full

Catalyst 2360 Switch Getting Started Guide

HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch

QuickSpecs. HPE OfficeConnect 1820 Switch Series. Overview. HPE OfficeConnect 1820 Switch Series. Models

HP Designjet L25500 printer series. Site preparation guide (Second edition)

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

TRC-190 User s Manual

Chapter 1 Product Introduction

HPE FlexNetwork NJ5000 5G PoE+ Walljack Switch(JH237A)

Aruba 3000 Multi-Service Mobility Controller Series. Installation Guide

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

HP V1410 Switch Series Overview. Models HP V G Switch

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

QuickSpecs. HPE OfficeConnect 1420 Switch Series. Overview. Models. Key features

ProCurve Switch 1400 Series

Model 2380 Rack-Mount Kit

HP V1410 Switch Series. Product overview. Key features. Data sheet

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

10/28/52-Port Web-Smart Pro Gigabit Ethernet Switch 26-Port Web-Smart Pro 10G Ethernet Switch. Installation Guide.

Gigabit Ethernet Switch With 10G Uplinks. Hardware Manual MS400860M

TRC-190 User s Manual

QUICK START GUIDE 7000 SERIES DEVICES

Models HPE OfficeConnect XGT and 2XGT/SPF+ Switch HPE OfficeConnect G 4XGT Switch

iconverter 2-Module Power Chassis

Installing the Cisco MDS 9020 Fabric Switch

TippingPoint Zero Power High Availability Installation Guide

Models HPE Altoline QSFP28 x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP28 x86 ONIE AC Back-to-Front Switch

FOS-3114 Series 14-port L2+ Managed Gigabit Fiber Switch User s Guide

Models HPE OfficeConnect XGT and 2XGT/SPF+ Switch HPE OfficeConnect G 4XGT Switch

HARDWARE INSTALLATION GUIDE. Brocade ICX 7250 Switch Hardware Installation Guide

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

ExtremeSwitching 210 and 220 Series Switches: Hardware Installation Guide

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

Installing the Cisco SFS 3504 Server Switch

OV-MCR116. Media Converter Chassis System. User s Manual

Model 2380 Rack-Mount Kit

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Agilent 66000A 1200 W DC Modular Power System, GPIB

Avanti HP Series Centrifuges Preinstallation

Junos WebApp Secure 5.0 Hardware Guide

Installing the IPS 4345 and IPS 4360

Installation. Package Contents CHAPTER

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Hardware overview. Package contents MSM710, documentation, power supply, self-adhesive rubber feet.

AT-GS950/16 AT-GS950/24

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

NI 6521 Specifications

Installation and Quick Start Guide

Retired. Models HPE Altoline QSFP+ x86 ONIE AC Front-to-Back Switch HPE Altoline QSFP+ x86 ONIE AC Back-to-Front Switch

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Installation and Maintenance

FP-PS-4. Features. Installation

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Disclaimer. Note that the Midspan is designed for indoor use only.

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Dell MD1280 Storage Enclosure Getting Started Guide

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

This section describes Web resources for ordering parts, and for technical support and resources for ordering related documentation and software.

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

PT-7728/7828 Quick Installation Guide

Transcription:

HPE 2530 24-Port and 48-Port Switches Quick Setup Guide The switch drawings in this document are for illustration only and may not match your particular switch model. For more detailed instructions and information to set up your switch, view or download the Installation and Getting Started Guide for your switch at http://www.hpe.com/networking/support. 1. Unpack and check included parts. Documentation kit Switch Console port serial cable (DB-9 to RJ-45) Accessory kit (installation hardware) AC power cord 2. Prepare for installation. To avoid personal injury or product damage, review Safety and Regulatory Information for HPE 2530 24/48-Port Switches (page 4). 3. Power on and verify that Self-Test completes normally. Power on the switch by connecting the power cord through the AC power connector and switch on the power switch. *5900-4818* Copyright 2014, 2015 Hewlett Packard Enterprise Development LP The information in this document is subject to change without notice. Part Number: 5900-4818 Published: November 2015 Edition: 2

4. Install the switch hardware. Unplug the AC power from the switch before installing the switch hardware. Rack mounting: Use a #1 Phillips (cross-head) screwdriver to attach the accessory kit brackets to the switch using the eight 8-mm M4 screws. Then use the four number 12-24 screws to secure the brackets to the rack. NOTE: The HPE 2530 24-port and 48-port switches can also be mounted in 4-post racks and cabinets by using the HPE X410 Switch Rail Kit (J9583A). For instructions on using the kit, see the documentation that is included with the kit. Table or desktop mounting: Attach the four self-adhesive pads (included in the accessory kit) to the bottom corners of the switch and place the switch on a secure horizontal surface. Wall or under-table: Use a #1 Phillips (cross-head) screwdriver to attach the supplied brackets to the switch using the eight 8-mm M4 screws in the orientation shown. For wall-mounting, the network ports must be facing up or down. Do not mount the switch with ventilation or fan ducts facing up or down. ( See Installation Precautions (page 4).) Attach the switch to the wall or wood surface with four 5/8-inch number 12 wood or tap screws (not included). 5. Power on the switch. As shown in step 3. 6. Connect network cables. NOTE: For transceiver connections, install and use only Hewlett Packard Enterprise SFP transceivers supported by the switch.

See SFP Installation Notes (page 3). 7. (Optional) Configure the switch for management. By factory default, the switch will automatically obtain its IP network configuration from a DHCP or BootP server. Subsequently, you can determine the IP address assigned to the switch by inspecting your DHCP/BootP server or by using LLDP from a connected device. You can also manage and configure the switch through a console port connection. Connect a VT-100 terminal or PC (with suitable terminal emulation software) to the switch using the serial cable (DB-9 and RJ-45 connectors) supplied with the switch. NOTE: You can also connect a console to the switch through the USB console port (cable not provided). Use a USB 2.0 high-speed cable with a male type A (4-pin) to male micro-b (5-pin) connector. Maximum allowable length is 5m. For more information on using the USB console port, see the Installation and Getting Started Guide for your switch. For information on configuration and remote management, see the Management and Configuration Guide for your switch. The manuals are available at http://www.hpe.com/networking/support. SFP Installation Notes Use only genuine Hewlett Packard Enterprise SFPs. Non-Hewlett Packard Enterprise SFP transceivers are not supported. Use of genuine Hewlett Packard Enterprise products ensures that your network maintains optimal performance and reliability. Should you require additional transceivers, contact an Hewlett Packard Enterprise sales representative or an authorized reseller. Hot swapping SFP transceivers. Supported SFP transceivers that you can install in your Hewlett Packard Enterprise switch can be hot swapped removed and installed while the switch is receiving power. You should disconnect the network cables from the SFP transceivers before hot-swapping them. When you replace an SFP transceiver with another of a different type, the switch may retain selected port-specific configuration settings that were configured for the replaced unit. Be sure to validate or reconfigure port settings as required.

SFP connections to devices with fixed speed/duplex configurations. When connecting a device to your switch port that contains an SFP transceiver, the speed and duplex settings of the switch port and the connected device must match; otherwise, the device may not link properly you may not get a link. For some older network devices, including some older Hewlett Packard Enterprise devices, the default speed/duplex settings may be predefined (for example, to 1000 Mbps/Full Duplex), or otherwise set differently from the default configuration of your switch port. Because of these default speed/duplex considerations, you should ensure that devices connected to your SFP ports are properly configured. At a minimum, make sure the configurations match. Environmental limitations. If using SFPs with the switch, ensure that the operating temperature range at the switch installation site does not exceed the range allowed for the SFP. Safety and Regulatory Information for HPE 2530 24/48-Port Switches To avoid personal injury or product damage when installing your switch, read the installation precautions and guidelines below. Installation Precautions WARNING! The rack or cabinet should be adequately secured to prevent it from becoming unstable, tilting or falling. Devices installed in a rack or cabinet should be mounted as low as possible, with the heaviest devices at the bottom and progressively lighter devices above. Do not wall-mount any switch without checking for restrictions in the Installation and Getting Started Guide. Wall-mount the switch with network ports facing up or down (away from or toward the floor). Do not wall-mount the switch with the ventilation or fan ducts facing up or down. CAUTION: Ensure the power source circuits are properly grounded, then use the power cord supplied with the switch to connect to the AC power source. If your installation requires a different power cord than the one supplied with the switch and/or power supply, be sure the cord is adequately sized for the switch s current requirements. In addition, be sure to use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country/region. The mark is your assurance that the power cord can be used safely with the switch and power supply. When installing the switch, the AC outlet should be near the switch and should be easily accessible in case the switch must be powered off. Ensure the switch does not overload the power circuits, wiring, and over-current protection. To determine the possibility of overloading the supply circuits, add together the ampere ratings of all devices installed on the same circuit as the switch and compare the total with the rating limit for the circuit. The maximum ampere ratings are usually printed on the devices near the AC power connectors. Do not install the switch in an environment where the operating ambient temperature exceeds its specification. Ensure the air flow around the switch is not restricted. Leave at least 7.6 cm (3 inches) for cooling. For the air flow direction, see the Installation and Getting Started Guide for your product, located on the Hewlett Packard Enterprise Networking web site at http://www.hpe.com/ networking/support.

Regulatory information For important safety, environmental, and regulatory information, see Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at http://www.hpe.com/support/ Safety-Compliance-EnterpriseProducts. Product Specifications HPE 2530-24G-2SFP+ Switch (J9856A) HPE 2530-48G-2SFP+ Switch (J9855A) HPE 2530-24G-PoE+-2SFP+ Switch (J9854A) HPE 2530-48G-PoE+-2SFP+ Switch (J9853A) Electrical: 1 AC voltage: Maximum current: Frequency range: 100 127 V / 200 240 V 0.70 A / 0.40 A 50 / 60 Hz 100 127 V / 200 240 V 0.80 A / 0.50 A 50 / 60 Hz 100 127 V / 200 240 V 2.90 A / 1.40 A 50 / 60 Hz 100 127 V / 200 240 V 5.5 A / 2.7 A 50 / 60 Hz Acoustics: Geraeuschemission LpA=29.4 db am fiktiven Noise Emission LpA=29.4 dbat virtual workspaceaccording to Geraeuschemission LpA=32.2 db am fiktiven Arbeitsplatz nach Noise Emission LpA=32.2 dbat virtual workspaceaccording to Geraeuschemission LpA=31.3 db am fiktiven Arbeitsplatz nach Noise Emission LpA=31.3 dbat virtual workspaceaccording to Geraeuschemission LpA=36.4 db am fiktiven Arbeitsplatz nachdin 45635 T.19 Noise Emission LpA=36.4 dbat virtual workspaceaccording to 1 The HPE 2530 switches automatically adjust to any voltage between 100 127 and 200 240 volts and either 50 or 60 Hz. Environmental: All HPE 2530 24-Port and 48-Port Switches Operating Temperature: Relative humidity: Non-Operating Temperature: Non-Operating Relative humidity: Maximum Operating Altitude: Maximum Non-Operating Altitude: 0 C to 45 C (32 F to 113 F) 15% to 95% at 40 C (104 F) (non-condensing) -40 C to 70 C (-40 F to 158 F) 15% to 90% at 65 C (149 F) (non-condensing) 3.0 km (10,000 ft) 4.6 km (15,000 ft) Safety: Standards: Lasers: EN60950-1:2006+A11:2009+A1:2010+A12:2011 / IEC60950-1:2005; Am1:2009; CSA22.2 No. 60950-1-07 2nd; UL60950-1 2nd EN 60825-1:2007 / IEC 60825-1:2007 Class 1 Class 1 Laser Products / Laser Klasse 1

Power Cord Use one of the following: Country/Region Switch Model Argentina Australia/New Zealand Brazil Chile China Continental Europe Denmark India Israel Japan Malaysia Switzerland South Africa South Korea Taiwan Thailand United Kingdom/Hong Kong/Singapore HPE 2530-24G-2SFP+, HPE 2530-24G-PoE+-2SFP+, and HPE 2530-48G-2SFP+ Switches 8120-6869 8121-0834 8121-1069 8120-6980 8120-8377 8120-6802 8120-6806 8121-0780 8121-1035 8120-6804 8120-6809 8120-6807 8121-0919 8120-6811 8121-0964 8121-0673 8120-6809 HPE 2530-48G-PoE+-2SFP+Switch 1 8120-8375 8121-0857 8121-1132 8120-8389 8121-1034 8120-5336 8120-5340 8120-5341 8121-1009 8120-5342 8120-5334 8120-5339 8120-5341 8120-5336 8121-0967 8121-0671 8120-5334 United States/Canada/Mexico 8120-6805 8121-0973 1 The power cord for the HPE 2530-48G-PoE+-2SFP+Switch supports a higher amperage and uses a C15 connector. WARNING! Japan Power Cord: Important Note for the 2530-PoE+ Switches For PoE/PoE+ information see the HPE Power over Ethernet (PoE/PoE+) Planning and Implementation Guide on the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/support. Transceiver Support Notes Revision B or later SFP transceivers only. This switch requires revision B or later SFP transceiver products the product number ends with the letter B or later (for example, J4858B, J4859C). Use only genuine Hewlett Packard Enterprise transceivers. For a list of HPE SFP or SFP+ transceivers supported by various Hewlett Packard Enterprise switch products, visit http:// www.hpe.com/networking/support:

1. In the first text box, type J4858 (for 100-Mb and Gigabit information) or J8436 (for 10-Gigabit information). 2. Select any of the products that display in the drop down list. 3. Select Product support information. Then click on Manuals and find the Transceiver Support Matrix. Third-Party connectivity accessories Hewlett Packard Enterprise designs and manufactures its products for use with genuine Hewlett Packard Enterprise connectivity accessories such as transceivers and SFPs. Use of genuine Hewlett Packard Enterprise products ensures that your network maintains optimal performance and reliability. Third-party connectivity accessories including any non-genuine products are not supported and their use may result in product malfunction, or in degraded network performance and reliability. Customers who choose to purchase, install, or use third-party or non-genuine Hewlett Packard Enterprise connectivity accessories do so at their own risk. Hewlett Packard Enterprise, at its discretion, may not provide support for networking problems resulting from the use of third-party transceivers or SFPs. However, the warranty on genuine Hewlett Packard Enterprise products is not affected. Should you require additional Hewlett Packard Enterprise connectivity accessories, please contact a Hewlett Packard Enterprise sales representative or authorized reseller. Hot swapping transceivers. The transceivers that you can install in your Hewlett Packard Enterprise switch can be hot swapped removed and installed after the switch starts receiving power. You should disconnect the network cables from the transceivers before hot swapping them. Best practice tip: After inserting a transceiver into a switch, the Mode LED will be on for two seconds while the transceiver is initialized. Do not remove the transceiver until the Mode LED has turned off. When you replace a transceiver with another transceiver of a different type and then execute the write memory command through the switch console, the switch configures the port on the new transceiver with the default mode (speed and duplex) settings used for the new transceiver type. The default mode for the transceivers is Auto. The switch retains other port-specific configuration settings, such as trunking, (STP) Spanning Tree Protocol, and VLAN values that were configured for the previous transceiver. Connecting the transceivers to devices with fixed configurations. For some older network devices, including some older Hewlett Packard Enterprise devices, the default for Gigabit-SX, Gigabit-LX, and Gigabit-LH ports is a fixed configuration (for example, 1000 Mbps/Full Duplex) or may be otherwise different from the default transceiver configurations (which is Auto). As a result, devices may not connect properly to your transceiver port and you will not get a valid link. Because of these default configuration and full-duplex considerations, for best operation, you should ensure that the devices connected to the transceiver ports are also configured to Auto. At a minimum, make sure the configurations match. Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hpe.com). When submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of the document. For online help content, include the product name, product version, help edition, and publication date located on the legal notices page.

*5900-4818* Printed in the US