IPS INTELLIGENT PUMP STARTER

Similar documents
EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

ENERGY MANAGEMENT SOFT-STARTER THE MOST INTELLIGENT SOFT-STARTER YET

Smartstart Control Module

SMARTSTART MOTOR STARTERS

FRANKLIN CONTROL SYSTEMS HVAC SMART STARTERS

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

MODELS DPDT DPDT DPDT-60MS DPDT-60MS

SP SP-T-9

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

PowerFlex 400 AC Drive Guide Specification

S.W. Version SubMonitor Connect Installation & Operation Manual

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

PHASE MONITOR RELAYS Product Summary

E1 Plus Electronic Overload Relay

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

LM10 to MM200 Retrofit

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Fire Pump Controllers Jockey Pump Controllers

Baltimore Aircoil Company

Compact Coded Magnetic Safety Interlock Switch and Control Units

Trident and Trident X2 Digital Process and Temperature Panel Meter

LOW HARMONIC DRIVE U1000

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Standard SureVolt Power Conditioner / Voltage Regulator

SECTION ( ) LIGHTING CONTROL PANELBOARD

SECTION SWITCHBOARDS

Quick Start Guide TS A

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

STANDARD SUBMITTAL PACKAGE

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

VLT 2800 DRIVE SPECIFICATIONS

QCPort Cover Control Trouble Shooting Guide

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

SED2 Variable Frequency Drives

For normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Enclosed DOL Motor Starter Type 4x, Plastic, 3-Phase

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

A drive dedicated to variable speed control for HVAC applications

INTEGRATED AUTOMATION ACTUATORS AND OPERATORS

SECTION DISCONNECT SWITCHES

MAJOR VA Power Inverter

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

SED2 Variable Frequency Drives

AIR COOLED MODULAR RECTIFIER

AND OPTIONAL ACCESSORIES

Jockey Pump Controllers

Operating Instructions. For. Level Control Module. Model SSR 1000

Controls Enclosed Non-Combination Starters - PESW Series

GS1 and GS2 Series AC Drives

Specification Sheet For electronically commutated motors

GE Power Management. MMII Intelligent MCC Controller

Supplementary operating instructions for your air curtain system Controller TMC 500

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

RX Series. MotorProtection/OverloadRelay ,000VAC,1through2000A ADVANCEDINSTALLATION,OPERATION COPYRIGHT2016 ALLRIGHTSRESERVED,MOTORTRONICSINC.

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

METERING/DISPLAY MANUAL

Installation, Operation and Maintenance Manual

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Jockey Pump Controllers

Multi-Point Gas Detection and Control System

New Solutions. for AC Motor Starters

160 AA02SF1 AF DS-D17

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

Installation Manual for D244X Series 24-volt Power Supplies

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

Installation Manual Updated May 2017

High Voltage DC Meter

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers

PowerFlex 40 Sample Specification

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

TECHNICAL BROCHURE BCPNEMAST R0. NEMA Rated Three-Phase Starters BY EATON

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

Q9 ASD LOW VOLTAGE DRIVE

Product Description. Table of Contents

SSW06. Soft Starters.

Transcription:

IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60 Hz, 20~AC, /2~00 hp INTEGRATED TRU-POWER ELECTRONIC PROTECTION Eliminates need for costly pump protection relays Dry pump detection using power (nuisance trip-free); time-based automatic restart and well recovery mode Features a wide-range, adjustable, class -0 electronic overload Provides superior motor protection from the following conditions: Over/Under power (dry-run) Over/Under voltage protection Voltage phase loss Voltage and current phase unbalance Stalled/locked rotor Cycle fault Ground fault (UL 0 certified) Voltage phase reversal BUILT-IN POWER MONITORING AND FAULT LOGGING View voltage, current, power factor, and more through an intuitive display Quickly identify common power problems such as phase imbalance, voltage drop, and over/under current conditions to ensure proper pump operation Built-in fault log, counter and parameter change log: records last fault types with power condition values, stores how many times each fault type has occurred (up to 2 count), and logs changes to parameter settings (e.g. FLA, OV/UV, under power) TRU-POWER SENSING Tru-power sensing protects pumps from dry-run, dead head, run-out, and jammed impeller conditions - keeping you online and preventing costly premature pump failure. Along with superior protection, measuring underload using power allows for a more flexible trip range, as opposed to measuring by current, which requires a more precise set point. The end result is the elimination of nuisance trips. POWER NO LOAD FULL LOAD CURRENT NO LOAD NOTE: Power is linear for superior load monitoring FULL LOAD 2

IPS INTELLIGENT PUMP STARTER EASY TO SET-UP AND USE Inside, the display shows an easy to use menu for setting a wealth of parameters. Adjust any protective or control setting in seconds. For example, choose how long to allow for dry well recovery, set run time periods, and on/off delays. All this with just a few intuitive keystrokes. The IPS ships with factory default settings pre-programmed for optimal submersible pump protection. INDUSTRIAL GRADE CONSTRUCTION Door mounted heavy-duty HOA switch Housed in an outdoor rated, gasketed, NEMA R enclosure Multi-tap control power transformer with integrated secondary protection accommodates common motor voltages. No fuses required! Includes 20 VAC control power for field devices NEMA/IEC rated magnetic contactors feature 2. million electrical cycles at full rated current ADVANCED PROGRAMMABLE PUMP CONTROL Automatic fault reset Backspin delay - Prevents start-up while system is draining On and off delay settings Well recovery mode (up to 8 hours) Minimum run time based on last input 2-20 V input for remote start/stop Dry contact input for remote start/stop The internal keypad and LCD make the IPS intuitive and versatile. Parameters are easily changed and faults are clearly displayed. Standard control features include a 2-20 V auto run input (irrigation control system, etc.), shutdown terminal for applications such as a low level float switch, and more. The multi-tap power transformer accepts inputs of 200 V, 20 V, and 60 V STANDARD CIRCUIT BREAKER DISCONNECT* UL 89 circuit breaker provides branch and short circuit protection No fuses required saves time and money Lockable handle for safety *Service entrance rated. OPTIONAL ETHERNET CARD Download and display up to 00 faults and alarms, including operational mode and values of operation at the time of fault All power condition values are stored by phase for voltage, current, and power factor per fault Data is easily displayed and saved on any web browser using an Ethernet connection. The IPS incorporates internal web-server. No additional software required Time- and date-stamped for utility documentation

IPS INTELLIGENT PUMP STARTER - ORDERING & SIZING INFORMATION IPS (20~60 VAC) - & -Phase, 0/60 Hz, 20~60 VAC, NEMA Type R Enclosed - Combination Starter. Includes Service Entrance Circuit Breaker Disconnect. 200 V - 60 V -PHASE SFA RANGE** (A) -PHASE HP (UL) / MA. FLA** -PHASE HP (UL) / MA. SFA** 20 V 200 V 20 V 60 V HP SFA HP SFA HP SFA HP SFA HP SFA IPSR-S-J-G 6~8 8 2 8 2 8 8 - - IPSR-S-J-G20 8~. 7. - - IPSR-S-J-G0 ~7 7 7 7 0 7 - - IPSR-S-J-G0 6~22 22 22 7. 22 22 - - IPSR-SP-J-G0 20~28 28 7. 28 0 28 20 28 - - IPSR-SP-J-G60 2~ 0 0 2 - - + IPSR-S2-J-G80 2~ 7. 0 0 - - 2 IPSR-S-J-G00 0~7 0 7 7 20 7 0 7 - - IPSR-S-J-G2 0~7 7 20 7 2 7 0 7 - - IPSR-SP-J-G0 60~8 8 2 8 0 8 60 8 - - + IPSR-S-J-G200 80~ 2 0 0 0 7 - - IPSR-S-J-G20 00~DPV* 2 0 0 20 0 0 00 2 - - IPSR-S-J-G00 20~70 - - 0 70 0 70 2 70 - - IPSR-S-J-G00 60~220 - - 60 220 7 220 0 220 - - IPSR-S-J-G00 20~28 - - 00 28 00 28 200 28 - - IPSR-SP-J-G600 20~20 - - 00 20 00 20 20 20 - - IPSR-SP-J-G800 20~DPV* - - 2 9 0 60 00 6 - - *DPV = Differs per voltage **Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range. IPS W/ ETHERNET FAULT LOGGING (20~60 VAC) - & -Phase, 0/60 Hz, 20~60 VAC, NEMA Type R Enclosed - Combination Starter. Includes Service Entrance Circuit Breaker Disconnect. -PHASE HP (UL) / 200 V - 60 V MA. FLA** -PHASE HP (UL) / MA. SFA** -PHASE SFA 20 V 200 V 20 V 60 V RANGE** (A) HP SFA HP SFA HP SFA HP SFA HP SFA IPSR-S-J-G-E 6~8 8 2 8 2 8 8 - - IPSR-S-J-G20-E 8~. 7. - - IPSR-S-J-G0-E ~7 7 7 7 0 7 - - IPSR-S-J-G0-E 6~22 22 22 7. 22 22 - - IPSR-SP-J-G0-E 20~28 28 7. 28 0 28 20 28 - - IPSR-SP-J-G60-E 2~ 0 0 2 - - + IPSR-S2-J-G80-E 2~ 7. 0 0 - - 2 IPSR-S-J-G00-E 0~7 0 7 7 20 7 0 7 - - IPSR-S-J-G2-E 0~7 7 20 7 2 7 0 7 - - IPSR-SP-J-G0-E 60~8 8 2 8 0 8 60 8 - - + IPSR-S-J-G200-E 80~ 2 0 0 0 7 - - IPSR-S-J-G20-E 00~DPV* 2 0 0 20 0 0 00 2 - - IPSR-S-J-G00-E 20~70 - - 0 70 0 70 2 70 - - IPSR-S-J-G00-E 60~220 - - 60 220 7 220 0 220 - - IPSR-S-J-G00-E 20~28 - - 00 28 00 28 200 28 - - IPSR-SP-J-G600-E 20~20 - - 00 20 00 20 20 20 - - IPSR-SP-J-G800-E 20~DPV* - - 2 9 0 60 00 6 - - + *DPV = Differs per voltage **Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range. +

IPS INTELLIGENT PUMP STARTER - ORDERING & SIZING INFORMATION IPS (AC) -Phase, 0/60 Hz, AC, NEMA Type R Enclosed - Combination Starter. Includes Service Entrance Circuit Breaker Disconnect. -PHASE HP (UL) / MA. SFA** -PHASE SFA RANGE** (A) HP SFA IPSR-S-6J-G 6~8 8 IPSR-S-6J-G20 8~ 0 IPSR-S-6J-G0 ~7 7 IPSR-S-6J-G0 6~22 20 22 IPSR-S-6J-G0 20~27 2 27 IPSR-S2-6J-G60 IPSR-S2-6J-G80 2~ 2~ 0 0 2 IPSR-S-6J-G00 0~7 0 7 IPSR-S-6J-G2 0~7 60 7 IPSR-S-6J-G0 60~77 7 77 IPSR-S-6J-G200 IPSR-S-6J-G20 80~ 00~2 00 2 2 IPSR-S-6J-G00 IPSR-S-6J-G00 20~70 60~220 0 200 7 228 IPSR-SP-6J-G00 IPSR-SP-6J-G600 20~28 20~289 20 00 28 289 + ** Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range. IPS W/ ETHERNET FAULT LOGGING (AC) -Phase, 0/60 Hz, AC, NEMA Type R Enclosed - Combination Starter. Includes Service Entrance Circuit Breaker Disconnect. -PHASE HP (UL) / MA. SFA** -PHASE SFA RANGE** (A) HP SFA IPSR-S-6J-G 6~8 8 IPSR-S-6J-G20 8~ 0 IPSR-S-6J-G0 ~7 7 IPSR-S-6J-G0 6~22 20 22 IPSR-S6J-G0 20~27 2 27 IPSR-S2-6J-G60 IPSR-S2-6J-G80 2~ 2~ 0 0 2 IPSR-S-6J-G00 0~7 0 7 IPSR-S-6J-G2 0~7 60 7 IPSR-S-6J-G0 60~77 7 77 IPSR-S-6J-G200 80~ 00 IPSR-S-6J-G20 00~2 2 2 IPSR-S-6J-G00 IPSR-S-6J-G00 20~70 60~220 0 200 7 228 IPSR-SP-6J-G00 IPSR-SP-6J-G600 200~28 20~289 20 00 28 289 + ** Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range. OPTIONS (FACTORY INSTALLABLE) DESCRIPTION IPS--PH WIRING FOR SINGLE-PHASE MOTOR (REQUIRED FOR Ø, NO COST) IPS-MODBUS* MODBUS RTU COMMUNICATIONS CARD IPS-SRG20 SURGE SUPPRESSOR, 200/20 V IPS-SRG80 SURGE SUPPRESSOR, 60 V IPS-SRG600 SURGE SUPPRESSOR, IPS-RPL RUN PILOT LIGHT, GREEN IPS-FPL FAULT PILOT LIGHT, RED IPS-SPB START PUSH BUTTON CONTROL IPS-STSP START/STOP PUSH BUTTON CONTROL (IN LIEU OF HAND/OFF/AUTO SWITCH) IPS-2 2 VAC CONTROL CIRCUIT (IN LIEU OF 20 VAC CONTROL CIRCUIT) *Cannot be installed on IPS with ethernet fault logging

IPS INTELLIGENT PUMP STARTER - DIMENSIONS & WIRING DIAGRAM DIMENSIONS STARTER H W D IPSR-S-J-G IPSR-SP-J-G IPSR-S2-J-G IPSR-S-J-G 22 0 IPSR-SP-J-G IPSR-S-J-G IPSR-S-J-G 2 2 2 0 2 IPSR-SP-J-G 62 2 NOTE: All dimensions in inches W H D WIRING DIAGRAM IPS PCB A CAT Input CON A2 COIL PWR Dry Inputs Relay Outputs Voltage Inputs Actuator Control Common D Hand D2 Auto D Status O2 Common O Fault O V Auto Run V V2 Shut Down V Motor A2 Limit Switch A Common A 2-20VAC/DC Input 20VAC, 0.2A Output JDS N.O. Input See Table DM L L2 L MCCB H H A B C OL GND CAT Output SURGE SUPPRESOR TABLE STANDARD - HOA SWITCH Common OFF H A Hand Auto IPS-SPB OFF H A Common CPT 20V To V/V Auto Run N *See Notes & JAR V 2-20VAC/DC Auto Run Input V Auto Run CON L T T L2 T2 T2 L T T 2 Hand Auto IPS-STSP STOP Common START 208V 20V 80V H2 M Hand START TRANSFORMER PRIMARY CIRCUIT BREAKER SIZING PH Auto H H VA V 208/20 80 0VA N/A N/A 00VA A A NOTES: Standard wiring schematic shown. Actual product wiring may vary depending on options selected. Dashed lines indicate field wiring. Checked boxes indicate factory installed options. Remove jumper JDS to wire limit switch. When jumper jar is present, terminals V & H2 act as connections for a normally open, dry contact, auto run input. Remove jumper jar to use V & V terminals as a voltage, auto run input. Apply 2~20 VAC/DC to energize. 6

IPS INTELLIGENT PUMP STARTER - SPECIFICATIONS SPECIFICATIONS Inputs Outputs Operational Settings Adjustments Hand/Off/Auto Voltage Auto Dry Contact Auto Shutdown Actuator Position Switch Status Relay Fault Relay Actuator Power Overload Type Power Fail Modes On/Off Time Delay Fault Reset Ambient Operating Temp Ambient Storage Temp Relative Humidity STARTER TYPE Combination - Service rated, suitable for use as a service disconnect NEMA Type R Enclosed USER INTERFACE Internal Door mounted -position switch STANDARD CONTROL OPERATIONS Accepts 2-0 VAC/DC. Applying voltage will send a run command to the starter when in auto mode. Normally open dry contact. When closed, the starter will be commanded to run when in auto mode. Accepts 2-0 VAC/DC. Applying voltage will open the contactor and the starter will not accept a run command Hand/Off/Auto LEDs will flash. Normally open dry contact. To be used in series with customer provided actuator contacts which disable the motor starter until the actuator is in position. (i.e. The contactor will not close unless this contact is closed) Normally open relay contact, 0.A @ 2 VAC, A @ 2 VAC Normally open relay contact, 0.A @ 2 VAC, A @ 2 VAC 20 VAC, 0.2A max. Electronic, I2T trip curve Restart in last mode (Hand/Off/Auto) with no delay (default) Restart in off mode Restart in off mode if power failure lasts longer than 2 seconds. Restart in last mode if power failure is less than 2 seconds. On/Off, adjustable: 0.-99 seconds Adjustable: Manual or automatic (default differs per motor protection feature) ENVIRONMENTAL - F to 0 F (-20 C to 60 C) - F to 8 F (-20 C to 8 C) % to 9% non-condensing MOTOR PROTECTION ADJUSTMENT / DESCRIPTION DEFAULT SETTING Overload Current Setting Range Differs per model Per SFA Overload Trip Class Adjustable: -0 0 Overload Service Factor Adjustable: 0.00-2.00. Under Power On/Off, adjustable: 0-99% of measured electrical input On / 60% Over Power On/Off, adjustable: 0-200% of measured electrical input On / 20% Over/Under Voltage On/Off, adjustable: +-2% over/under the nominal voltage setting On / 0% Voltage Phase Unbalance On/Off, adjustable: -20% voltage phase deviation On / % Voltage Phase Loss Always on, adjustable: -0% voltage phase deviation 0% Voltage Phase Sequence Reversal On/Off, trips within 0. seconds upon voltage phase reversal detection On Ground Fault (UL 0 Certified) On/Off, adjustable:.0-9.9a On / A Cycle Fault On/Off, adjustable: Trip if cycle rate exceeds 20 starts/minute On Warm Start Provision On/Off, delays motor restart based on calculated motor temperature On SMARTSTART PROTECTION ADJUSTMENT / DESCRIPTION DEFAULT SETTING Current Phase Unbalance On/Off, adjustable: -0% current phase unbalance On / % Locked Rotor / Stall On/Off, trips within 0. seconds On Out of Calibration On/Off, trips after 0 seconds if the FLA dial setting is incorrect (set above calculated FLA range), i.e. start current is outside of an acceptable range (FLA setting * < in-rush < FLA setting * ). On Max Time to Start On/Off, regardless of FLA or I2T curve, always trip at start if starting current is outside of an acceptable range (in-rush / ) and still decreasing after 0 seconds. On 7