SCSI Fiber Optic Extender

Similar documents
Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

RS-232/RS-422 Optical Isolator

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

3174/3274 I-Mux FEBRUARY 1993 MX330A-C MX330A-D CUSTOMER SUPPORT INFORMATION

DRD-4 DRD-4 JULY 1992 FX140A CUSTOMER SUPPORT INFORMATION

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

USB USB Data Transfer

PC Media Converter, Switching (TP-TX/FX)

3270 Repeater Fiber 3270 Repeater UTP 3270 Repeater Fiber RJ Repeater UTP RJ45

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

10/100 Autosensing PC Media Converter

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

Four Port RS-232 Serial Interface

Personal MiniHub. Personal MiniHub RX LINKPORT #AUI PORT 5 UP LINK PWR JUNE 2001 LE2650A LE2650AE CUSTOMER SUPPORT INFORMATION

DB9 Microdriver CUSTOMER SUPPORT INFORMATION JULY 1994 ME792A ME793A ME794A

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

ADL-100 Operator s Manual

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved.

Dual Port RS-232 Serial Interface

Cat. No KT/B. Installation Data

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

1.0 Description. 2.0 Unpacking. 3.0 Installation

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

Computertop TV-I. Computertop TV-I SEPTEMBER 1993 AC451A CUSTOMER SUPPORT INFORMATION

INSTALLATION INSTRUCTIONS

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

CANADIAN D.O.C. WARNING

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

SYSNet QS7700A Network Interface ControlBus Module for BCS7700

DSU 5600 Data Service Unit USER MANUAL

Installer/User Guide

Connectivity Peripherals User s Guide. Point 510 Point 1600

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

INSTALLATION AND OPERATIONS MANUAL

TELink FLASH. Model 700a. Installation and Operation Instructions. Magic On Hold is a Registered Service Mark and Trademark of Avaya Communications

Giga-MiniMc TX & RX USER MANUAL

Rack Input Module Installation Instructions

BEETLE /Fusion Compact. Installation Guide

FiberLinX Modules Hardware Installation Manual

PCI Differential Ultra SCSI Adapter Installation and User's Guide

Quick Start Installation Guide

CrystalLink USB 2.0 CAT5 INSTALLATION AND OPERATIONS MANUAL. Part Number CLK-1U4TP-100M/PE Stancliff Road Phone: (281)

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

CHS 7Ci. Bluetooth Cordless Barcode Scanner. Quick Start Guide

NETGEAR, Inc Great America Parkway Santa Clara, CA USA. April 2004

Allworx Tx 92/24 Telephone Expander Installation Guide

Infosystem Remote Touchscreen Installation Instructions

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Optical DVI Daisy-chain Extender

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

BEETLE MSR Module. Swipe Card Reader. for BA7x. User Guide

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual

TELink 700 FLASH INSTALLATION AND OPERATION MANUAL

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

Support for Non-Ultra2 SCSI Devices

LN Series Remote Input/Output (I/O) Modules

Fast Ethernet Switch AT-FS705L. Installation Guide Rev. A

Installation Guide for. PCC Premier Precision Camera Controller. Document Rev. C

SCSI Adapter. A device-independent interface for attaching tape drives. Documentation Edition 2

68-pin Internal Ultra160-LVD Connector. Adaptec SCSI Card 29160N

Operating Instructions

7800 SERIES S7810B Multi-Drop Switch Module

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved.

Verify Package Contents

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

User s Guide CPSMM Dual-Slot Master Management Module CPSMM Single-Slot Expansion Management Module

twister 2131 Optical Extender

RS-422/485 to Fiber Industrial Converter

AdderLink X50 USB. User.Guide. contents ADDER LOCAL POWER OUT LINK TO REMOTE

Operator s Manual For Use With the Signature III CD Color Printer or Inscripta Thermal CD Printer

SCSI Model Flash Drive --- MFD35C-xxxxS Series ---

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

2DScan TM Barcode Scanner

Connects 1000BASE-T twisted-pair to 1000BASE-SX/LX fiber.

Monarch 939i Intelligent Keyboard

PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL

Digital Storage Products Model DSP5200 Model DSP5350 Installation Guide. Order Number: EK-DS002-IG. C01

NCH-1000 (Multiple Breaker Types) Installation Instructions

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

CANADIAN D.O.C. WARNING

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

NSD/M1 Installation Instructions

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

Modular Media Converter Installation Guide (includes 10 Mbps Ethernet, 100 Mbps Fast Ethernet and Protocol-Independent Fiber Mode Conversion Modules)

G.SHDSL NTU DECEMBER 2006 LB510A

Enclosure TS-530 User Manual

AHA-3980/3980W AHA-3985/3985W

User s Guide CPSMC Single-Slot Point System Chassis with Internal Power Supply

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

DIGITAL IO BOX Owner s Manual

Transcription:

Black Box Corporation The Source for Connectivity JUNE 1996 IC495A-R2 SCSI Fiber Optic Extender SCSI FIBER OPTIC EXTENDER LINK ACTIVE BUS ACTIVE LINK ERROR POWER CUSTOMER SUPPORT INFORMATION Call our Technical Support Specialists to discuss your application. For 24-hour technical support: Call (412) 746-5500 or Fax: 1-800-321-0746 To order: Call (412) 746-5500 8:00 A.M. to 8:00 P.M. EST Mail order: Black Box Corporation, P.O. Box 12800, Pittsburgh, PA 15241

SCSI Fiber Optic Extender FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. TRADEMARKS All applied-for and registered trademarks are the property of their respective owners. ST is a registered trademark of American Telephone and Telegraph Company. 2

FIBEROPTIC INTERFACE CHAPTER 1: Specifications Maximum Cable Length Up to 3000 ft. (about 1 km) of duplex fiberoptic cable between a matched pair of extenders Recommended Fiberoptic Cable 62.5/125 µm, 100/140 µm, or 50/125 µm Serial Data Rate 175 MHz Optical Wavelength 830 nm Typical Bit Error Rate (BER) 10-12 SCSI INTERFACE Maximum SCSI Cable Length 19.7 ft. (6 m) Maximum Speed 10 megabytes per second Slew Rate 5 ns (maximum) Protocol Sync or async Standards ANSI X3.131 and X3T9.2 Interface Compatible with SCSI I and SCSI II SCSI to Fiber Conversion Delay 200 ns Termination Active Internal Bus PHYSICAL Indicators (4) LEDs: Line Active, Bus Active, Line Error, Power Connectors (2) fiber ST, (1) 50-pin SCSI, (1) IEC (power) Power 110/220 VAC ±10%, 65/45 Hz (switch-selectable), 7 watts Size 2.1"H x 6"W x 9.6"D (5.3 x 15.2 x 24.4 cm) Weight 3 lb. (1.4 kg) 1. Specifications 3

SCSI Fiber Optic Extender 2.1 Overview 2. Introduction The SCSI bus (pronounced scuzzy) is one of the most popular interfaces for connecting peripheral devices to a computer system. However, the maximum allowable cable distance from computer to SCSI peripheral is just 19.7 ft. (6 m). But by using a pair of SCSI Fiber Optic Extenders, you can far exceed that distance. Now you can connect SCSI components such as disk drives, CD-ROM systems, RAID arrays, tape backup drives, and laser printers up to 3000 feet (about 1 km) from the host computer, via fiberoptic cable (see Figure 2-1). SCSI Peripherals Host Computer SCSI Terminators SCSI Fiber Optic Extenders Linked Via Duplex Fiberoptic Cable Up To 3000 feet (1 Km) SCSI Terminators Figure 2-1. Sample Application Using SCSI Fiber Optic Extenders. Note the location of the SCSI terminators. SCSI Fiber Optic Extender supports a maximum SCSI data rate of 10 MBytes per second in asynchronous or synchronous mode. It supports the Fast SCSI standard, available in top-of-the-line computers and peripherals. And proprietary switching enables the Extender to maintain complete SCSI command functionality and remain transparent to the user. The Extender conforms to ANSI X3.131 and X3T9.2 specifications with single-ended device termination. Disconnect and Reselect are fully supported to ensure complete SCSI compatibility. Also, the Extender does not require a SCSI device address. Besides extending a single SCSI chain, you can use a pair of these Extenders to link two remote SCSI chains (see Figure 2-2), enabling computer users in distant workgroups to share multiple SCSI peripherals. 4

CHAPTER 2: Introduction Duplex Fiberoptic Cable Up To 3000 feet (1 Km) SCSI Terminators SCSI Terminators Figure 2-2. Sample Application Using SCSI Fiber Optic Extenders. Note the location of the SCSI terminators. Connect to a host or peripheral via the single-ended SCSI connector on the rear panel of the Extender. An internal active bus terminator is included to improve SCSI reliability and performance. This terminator can be removed for systems requiring external termination. A standard duplex fiberoptic cable with ST connectors provides the interface between the local and remote Extender units. And for greater application flexibility, the Extender supports 110- or 220-VAC operation via a user-selectable switch and International standard IEC power connector. 2.2 Unpacking Your Shipment Unpack your SCSI Fiber Optic Extender from its original shipping carton and inventory the contents. The package includes: (1) SCSI Fiber Optic Extender. (1) IEC AC Power Cord. (1) Package of Replacement Parts: (1) 1-Amp fuse (1) 2-Amp fuse (1) 110-ohm network resistor. This User s Manual. 5

SCSI Fiber Optic Extender 2.3 Operator Controls and Indicators Four front-panel LEDs light to give you at-a-glance status information about the operation of the Extender (see Figure 2-3.). POWER This lights when AC power is connected and switched-on to the unit. LINK ACTIVE This LED lights when two SCSI Fiber Optic Extenders are powered up and connected to one another via fiberoptic cable. BUS ACTIVE This LED provides a visual indication of the SCSI interface BUSY signal. It is a general indication that devices are communicating via the SCSI bus. LINK ERROR Lights when the integrity of the fiberoptic link dips below specification. When this LED is lit, data errors have occurred. The SCSI Fiber Optic Extender will disconnect from the SCSI bus when a Link Error is detected. POWER SWITCH Located on the rear panel (see Figure 3-1.) Turn on power by pressing the half of the switch marked 1. Turn power off by pressing the half of the switch marked O. LINK ACTIVE BUS ACTIVE LINK ERROR POWER Figure 2-3. Front-Panel View. 6

2.4 Calling Your Supplier CHAPTER 2: Introduction If the Extender arrives incomplete, or subsequently malfunctions, do not attempt to alter or repair the unit. It contains no user-serviceable parts. Contact your supplier. Before you do, make a record of the history of the problem. Your supplier will be able to provide more efficient and accurate assistance if you have a complete description, including: The nature and duration of the problem. When the problem occurs. The components involved in the problem. Any particular application that, when used, appears to create the problem or make it worse. 2.5 Shipping and Packaging If you need to transport or ship your SCSI Fiber Optic Extender: We recommend that you use the original packaging container. If you are shipping the unit for repair, make sure you include its power supply. If you are returning it, make sure you include this manual as well. Before you ship, contact your supplier to get a Return Materials Authorization (RMA) number. 7

SCSI Fiber Optic Extender 3. Installation The SCSI Fiber Optic Extender requires no software configuration and only nearby access to an AC electrical outlet for proper operation. That makes installation fast and easy. Install the Extender in any position and any location near the host computer or peripherals that s most convenient for you. Make sure that the ventilation slots on the side of the unit are unobstructed and receive adequate air flow. Do not place the Extender on any device that generates heat. NOTE Switch off power to all computers and peripherals attached to the SCSI bus before installing the SCSI Fiber Optic Extender. 3.1 Setting the AC Line Voltage Switch The SCSI Fiber Optic Extender can be powered from either a 110- or 220-VAC power source. Figure 3-1 shows the location of the external voltage-selection switch on back of the unit. The default setting is 110-VAC. CAUTION Before installing this unit, verify that the voltage-selection switch is switched to the appropriate setting to match your AC input source. AC Voltage-Selection Switch 110 220 I O POWER AC INPUT XMT RCV Figure 3-1. Rear-Panel View. 8

CHAPTER 3: Installation With the voltage-selection switch set properly, plug the female end of the power cord into the back of the unit and plug the male end of the cord into your AC power outlet. 3.2 Recommended Cable Twisted-Pair Cable A 50-pin shielded cable and connector will provide a connection with the greatest noise immunity and distance from your host or peripheral to the SCSI Fiber Optic Extender. But note that this cable connection may never exceed 6 feet (19.7 m). Section 3.5 describes requirements for connecting to the SCSI Bus. Appendix B shows the standard SCSI connector pinning chart. Fiberoptic Cable Up to 3000 feet (about 1 km) of standard, full-duplex multimode 62.5/125 µm, 100/140 µm, or 50/125 µm fiberoptic cable. Improper connector termination, splicing of the fiberoptic cable, or use of other cable diameters will result in reduced link distances and increased data error rates. Neither of these cables are included with this unit. Call your supplier to order them separately. 3.3 Internal/External Terminator Options The SCSI Fiber Optic Extender features internal active SCSI bus termination to improve the cable-matching characteristics between multiple SCSI devices. Since some applications require external terminators, you may remove these internal terminators for added application flexibility. To remove the internal terminators, remove the four screws on the bottom of the unit (see Figure 3-2) and gently unplug terminators RN1, RN2, and RN3 from their positions on the printed circuit board (PCB) (see Figure 3-3). Normally, terminators should be installed on opposite ends of the SCSI bus. Note that data errors may result if more than two sets of terminators are installed on any SCSI bus. 3.4 Internal Terminator Power and Fuse The SCSI Fiber Optic Extender contains a replaceable internal fuse to provide power for an external terminator. This fuse supplies 1 amp at 5 volts to the TERMPWR signal. The fuse is installed in the socket labeled F2 on the PCB (see Figure 3-3). The Extender contains internal protection and will not be affected if other SCSI devices provide terminator power. 9

SCSI Fiber Optic Extender 1 2 MODEL NO: ACI 2000A SERIAL NO: 2003100 INPUT VOLTAGE 110/220VAC 3 4 Figure 3-2. Remove Four Bottom-Panel Screws to Access the PCB. 3.5 Connecting to the SCSI Bus The SCSI Fiber Optic Extender provides a transparent, optically isolated SCSI bus over extended distances, so you can install the Extender at any point on your SCSI bus. Terminators must be installed on both the local and extended bus, so make sure that a maximum of two terminators are installed on each side of the Extender link (see Figures 2-1 and 2-2). Connect the twisted-pair cable from the host or SCSI peripheral to the 50-pin SCSI connector on back of the Extender. Use the bail-locking mechanism to anchor the connection securely. NOTE If external termination is required, be sure to remove the internal termination networks and replace them with an internal terminator fuse F2 (included). (See Figures 3-2. and 3-3.). 10

CHAPTER 3: Installation F2: TERMPWR Fuse (1-Amp) F2 RN1 RN2 RN3 RN1, RN2, RN3: Internal SCSI Terminators 1A @ 250V 1A @ 125V F1: Input Power Fuse (2-Amp) F1 Figure 3-3. Location of the Internal Fuses and Terminators. 3.6 Connecting the Fiberoptic Cable Most duplex fiberoptic cable is marked to indicate which fiber connector is transmit (XMT) and which is receive (RCV). Attach the appropriate connectors to the labeled ST connectors on the rear panel of the SCSI Fiber Optic Extender. Do this for both the local and remote Extender units. Take care to keep the fiberoptic connectors and optical components free of dust and dirt. And whenever cables are not atttached to the Extender s ST ports, cover them with the protective plastic caps included with the unit. For the link to operate properly, connect the transmit (XMT) port of the local Extender to the receive (RCV) port of the remote Extender and connect the receive (RCV) port of the local Extender to the transmit (XMT) port of the remote Extender. 11

SCSI Fiber Optic Extender To identify unmarked fiber connectors, attach both connectors at one end of the cable to the SCSI Fiber Optic Extender and then switch on power to the unit. Then visually examine both connectors at the opposite end of the cable to determine which one is the transmit fiber. A faint red light will be visible at the tip of one of the connectors. This indicates the transmit fiber. This is the connector that should be attached to the receive (RCV) port of the remote Extender unit. 3.7 Verify the Connection Switch on power to both SCSI Fiber Optic Extenders and verify that the LINK ACTIVE LEDs are lit on the front panels of both units. This confirms that the local and remote units are communicating. You may now switch on power to your attached computers and peripherals. 12

4.1 Overview 4. Operation CHAPTER 4: Operation The SCSI Fiber Optic Extender converts SCSI data and command information into a serial data stream that s transmitted over a high-speed (175-Mhz) fiberoptic interface to the remote Extender. The remote unit decodes the data stream and reconverts it back into proper SCSI signals. The fiberoptic serial link conforms to the ANSI X3T9.5 encoding scheme specified in FDDI local area networks and is virtually immune to all forms of radio-frequency and electromagnetic interferences (RFI/EMI). An unauthorized tap of the link is nearly impossible without detection. 4.2 System Performance The SCSI Fiber Optic Extender will support any combination of asynchronous and synchronous SCSI devices on the bus. Overall system performance will depend on the individual data rate and protocol of each SCSI device plus the overhead of the host computer. In general, devices connected via a SCSI Fiber Optic Extender link up to 300 feet ( about 100 m) will achieve aggregate data rates of 225 kilobytes per second in asynchronous mode. In synchronous mode, with a byte offset of 8, sustainable data rates of 4 megabytes per second can be expected. A synchronous offset of 16 will provide 5 megabytes per second data rates. 4.3 System Configuration Options The SCSI Fiber Optic Extender supports a maximum data rate of 10 megabytes per second. This data rate is often referred to as Fast SCSI. To ensure optimum system performance, some system configurations may require a secondary SCSI channel to interface with the Extender (see Figure 4-1). 13

SCSI Fiber Optic Extender Terminators Terminator Fiberoptic Cable Terminator Secondary SCSI Bus Primary SCSI Bus Figure 4-1. Alternate Configuration Linking Two SCSI Buses. In this configuration, the primary SCSI bus is used to connect the local high-speed peripherals. The secondary SCSI bus is used exclusively as the extended SCSI bus. 14

APPENDIX A: SCSI Signal Descriptions Appendix A SCSI Signal Descriptions A total of 18 signals are required for the SCSI interface. These signals are described as follows: BSY (BUSY) An OR-tied signal indicating that the bus is being used. SEL (SELECT) An OR-tied signal used by an initiator to select a target or by a target to reselect an initiator. C/D (CONTROL/DATA) A signal driven by a target that indicates whether CONTROL or DATA information is on the DATA BUS. True indicates CONTROL. I/O (INPUT/OUTPUT) A signal driven by a target that controls the direction of data movement on the DATA BUS with respect to an initiator. True indicates input to the initiator. This signal is also used to distinguish between SELECTION and RESELECTION phases. MSG (MESSAGE) A signal driven by a target during the MESSAGE phase. REQ (REQUEST) A signal driven by a target to indicate a request for a REQ/ACK data transfer handshake. ACK (ACKNOWLEDGE) A signal driven by an initiator to indicate an acknowledgement for a REQ/ACK data transfer handshake. ATN (ATTENTION) A signal driven by an initiator to indicate the ATTENTION condition. RST (RESET) An OR-tied signal that indicates the RESET condition. DB(7-0,P) (DATA BUS) Eight data-bit signals, plus a parity-bit signal that form a DATA BUS. DB(7) is the most significant bit and has the highest priority during the ARBITRATION phase. Bit number, significance, and priority decrease downward to DB(0). A data bit is defined as one when the signal value is true and is defined as zero when the signal value is false. Data parity DB(P) shall be odd. 15

SCSI Fiber Optic Extender Appendix B SCSI Connector Pinning CONNECTOR PIN NUMBER CONNECTOR PIN NUMBER SIGNAL NAME UNSHIELDED SHIELDED SIGNAL NAME UNSHIELDED SHIELDED -DB(0) 2 26 GROUND 1 1 -DB(1) 4 27 GROUND 3 2 -DB(2) 6 28 GROUND 5 3 -DB(3) 8 29 GROUND 7 4 -DB(4) 10 30 GROUND 9 5 -DB(5) 12 31 GROUND 11 6 -DB(6) 14 32 GROUND 13 7 -DB(7) 16 33 GROUND 15 8 -DB(P) 18 34 GROUND 17 9 GROUND 20 35 GROUND 19 10 GROUND 22 36 GROUND 21 11 GROUND 24 37 GROUND 23 12 TERMPWR 26 38 OPEN 25 13 GROUND 28 39 GROUND 27 14 GROUND 30 40 GROUND 29 15 -ATN 32 41 GROUND 31 16 GROUND 34 42 GROUND 33 17 -BSY 36 43 GROUND 35 18 -ACK 38 44 GROUND 37 19 -RST 40 45 GROUND 39 20 -MSG 42 46 GROUND 41 21 -SEL 44 47 GROUND 43 22 -C/D 46 48 GROUND 45 23 -REQ 48 49 GROUND 47 24 -I/O 50 50 GROUND 49 25 16

Black Box Corporation The Source for Connectivity Copyright 1996. Black Box Corporation. All rights reserved. P.O. Box 12800 Pittsburgh, PA 15241 (412) 746-5500 Fax (412) 746-0746