CLOCKAUDIO. MR88 Automatic Microphone Mixer RS232 Programming Version 4.2

Similar documents
Planar Simplicity Series

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC

AU5017. General Description

Technical Specification. Third Party Control Protocol. AV Revolution

Dual-axis Electronic Digital Magnetic Compass Module User s Guide

Dell S500/S500wi RS232 Protocol Document

Application Note BDLxxxx RS232 SERIAL INTERFACE COMMUNICATION PROTOCOL (SICP V1.82)

PRE32 RS232 protocol v1.21 Tomas Andersson

Dell 7609WU RS232 Protocol Document

Control Codes. Viewing control state (Get control command) Controlling (Set control command) Command. No. Command type Command Value range

SC1602LC 16x2 Large Characters RS232 LCD Module. User s Manual. Large Viewing Area 99mm x 24mm. Large Character Size. 4.84mm x 9.66mm.

RS232 User Guide. Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K. Simplicity Series 4K Displays User Guide A

Dell 4610X RS232 Protocol Document

RS-232 Control of the Advantage EQ281/8, EQ282/8 and Advantage SMS200

Appendix) Specifications of Monitor & Control Rev. 4.0 July 13, 2016

Titan Dot Matrix Display (A05)

ambient XC RS232 Control Command Specification

JMY505G User's Manual

MODEL TDAI-2170 INTEGRATED AMPLIFIER EXTERNAL CONTROL MANUAL

Interface Card, Interface Box, Datalogger & Interface. Bedienungsanleitung. Kommunikationsprotokoll. Operating Instructions. Communications protocol

1 SETTING UP GENERAL FUNCTION TYPE PROTOCOL MESSAGES COMMAND RETURN CODES... 6 TRANSACTION EXAMPLES...

RS-232 Control of the Advantage DRI

LCD Module with I2C / Serial Interface and Keypad Control «LCD I2C/Serial» User s Guide. Copyright 2008 IMS

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 3 Art. no.:

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam T32 Tuner

Serial Communication Control Interface User s Manual

Custom Installation Notes IP/Serial programming interface and IR remote control commands for the SA10/SA20 integrated amplifier

Venstar Thermostat Adapter

MTR-4. C8 Command to MODBUS Bridge User Manual F-1, No. 631, Chung Der Road, Sec 1, Taichung Taiwan.

JMY504M User's Manual

MCW Application Notes 24 th February 2017

CTT MODBUS-RTU COMMUNICATION PROTOCOL TEMPERATURE MONITOR DEVICE

Technical Information. Command overview of Vision Systems

Interface MDB SLAVE to RS232 v Quick reference

Device: MOD This document Version: 1.0. Matches module version: v1. Date: 24 February Description: MP3 Audio Module

1. Implemented CM11 protocol

Russound Dual Tuners (ST2, ST2-XM, ST2-XM2, and ST2S)

Logosol Joystick Node LS-731

Lumio Release Note Lumio Multi-Touch Communication Protocol

Input Channels: 4 differential or four single-ended. Address / Baud rate / range configurable by the user

AX-18F/ AX-18A. Part Photo. H/W Specification [AX-18F] [AX-18A]

Computer Control of the Advantage DRC 4+4

v1.10 Closer to Real, User s Manual RX-28 Dynamixel ROBOTIS CO.,LTD.

CyberAtom X-202 USER MANUAL. Copyrights Softexor 2015 All Rights Reserved.

SRF02 Ultrasonic range finder Technical Specification

M-BUS PROTOCOL for ML 311

Ethernet to Digital I/O and Analog Input. (Model: IP-IO)

EcologicSense. NEXT-PM User Guide. Ecologic Sense. ZI Rousset 296, Avenue Georges Vacher, Rousset - France

COMMUNICATION M-BUS PROTOCOL CE4DMID0M (MBus meter)

460 Presentation Audio Mixer

User Manual. Multi-display Control Module Protocol MCS. dedicated KVM switch and rackmount screen technology

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam UDP411 BD Player

Rotel RS232 Serial Bus Communication

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

CyberAtom X-200 USER MANUAL. Copyrights Softexor 2015 All Rights Reserved.

SECTION 5 SMART PAYOUT MANUAL SET SOFTWARE IMPLEMENTATION GUIDE

SC1602LCPro-YG ( Yellow Green Backlight ) SC1602LCPro-B ( Blue Backlight ) Large Character Size ( 4.88x9.66 mm )

Using the USB and Serial Interfaces

Keywords: CRC, CRC-7, cyclic redundancy check, industrial output, PLC, programmable logic controller, C code, CRC generation, microprocessor, switch

Custom Installation Notes: Serial programming interface for Arcam A/V processors & receivers

ROBOTIS e-manual v AX-12W. Part Photo [AX-12W] Hardware Specifications. Weight : 52.9g Dimension : 32mm * 50mm * 40mm

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam BDP100/300 BD Players

Blaupunkt ( DMS?? ) Page 1 of 13

C628 Enhanced JPEG Module. User Manual

INT-RS module - short technical description

SPI Lasers UK Limited. Serial Command Reference for the PRISM Laser Platform

variable 1. Start of Packet - is used to provide synchronization when parsing packets. Always 0xFC

imetos LoRa Data payload structure

Serial Communication Protocols

RS232C / RS485C Serial Interface for Cold Cathode and Cold Cathode Pirani Gauges

THANK YOU. Control System Communication Protocol Manual RackLink. Monitor Control Alert Report Analyze. Thank you for purchasing a RackLink product.

DMTME Multimeters. Communication protocol. Technical specification V1.2 ABB

E2 Modbus RTU Register Map

PROTOCOL TRANSPORTS 4 RS232 SPECIFICATIONS 4 RS232 CABLING 4 TCP/IP 4 PROTOCOL DOCUMENT NOTES 4 COMMUNICATION 4

Specifications Manual

SCYLAR INT 7. Communication description. Software Version 01

SCDM88-8x8 Serial LED Dot Matrix Display Module. Serial Interface. Serial Command Summary

Overview. 08/06/2012 Page 2/47

TBS Unify Pro / SmartAudio

GNetPlus Communication Protocol

variable 1. Start of Packet - is used to provide synchronization when parsing packets. Always 0xFC

RS232C Serial Interface for Pirani Diaphragm and Pirani Standard Gauges. Caution. binary 8 data bits 1 stop bit no parity bit no handshake

CAN / RS485. Product Description. Technical Reference Note. Interface Adapter. Special Features

M2M/DMTME Instruments Communication protocol. Technical specification V.2.1 2CSG445011D0201

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam Solo Movie 2.1 and 5.1

SPARC INTERNATIONAL. Version1 SPARC Keyboard Specification

Serial Communications Protocol Definition. Project: SDP-3

SHARKY BR773. Communication Description. Software Version 28

FN-BC04 MP3 Sound Module with 10W Amplifier. User s Manual

AN-946 APPLICATION NOTE

JMY501H User's Manual

CONNECTION TO A HOST COMPUTER

ECE251: Intro to Microprocessors Name: Solutions Mid Term Exam October 4, 2018

Touch Encoder. Interface Control Document (CANBUS J1939 Protocol)

NHD-0220D3Z-FL-GBW-V3

Integrated Serial Communication Protocol for MCA1120/PCA1120

Serial Communications Protocol Definition. Project: MC-12/MC-12B

The RS-485 user manual for B800 series communication

GSA GAT PROTOCOL V Game Authentication Terminal

Transcription:

CLOCKAUDIO MR88 Automatic Microphone Mixer RS232 Programming Version 4.2 Clockaudio Limited, 9 Stratfield Park Elettra Avenue, WATERLOOVILLE Hampshire. UK Tel : +44 (0)2392 251193 Fax : +44 (0)2392 251201 Email : sales@clockaudio.demon.co.uk

CONTENTS INTRODUCTION... 3 RS232 Physical Parameters... 3 RS232 Packets... 3 Checksum... 3 Reserved Bytes... 3 Data Field... 4 Commands... 5 Get Output Channels... 6 Get Input Channels... 7 Get System... 10 Get Headphone Monitor... 12 Get Channel Meters and Status... 14 Set Output Channels... 16 Set Input Channels... 17 Set System... 20 Set Monitor... 22 Set Defaults... 24 Get Version... 25 Page 2

INTRODUCTION The purpose of this manual is to assist programmers in successfully writing code to control the MR88 automatic mixer. This manual describes the RS232 interface to the MR88 automatic mixer. When more than one MR88 is linked via the Link In/Out connectors, the RS232 control will extend through the link. Any MR88 in the chain can be used as the RS232 input. The MR88 s are automatically addressed from 1 to n. The first MR88 in the chain is Mixer 1 RS232 Physical Parameters The MR88 is controlled via RS232: 38400 baud, no parity, 8 data bits 1 stop bits. The physical connection is to the DB9 way connector on the MR88 rear panel. Pin 2 Pin 3 Pin 5 Rx data to PC. Tx data from PC. Ground. RS232 Packets All RS232 packets, whether they are transmitted to, or received from the MR88 mixer, use the same packet format. All values are in bytes using unique headers and footers with byte stuffing. In this manual, a byte is represented by a hexadecimal number in the form 0xNN. Packet Header Data Checksum Packet Footer 1 byte ( 0x7E ) N bytes 1 byte 1 byte ( 0x7D ) Checksum The one-byte checksum is calculated as the 1 s complement of the sum of the data bytes, modulo 256 before byte stuffing. Therefore the sum of all the data bytes including the checksum will be 0xFF. If the data or checksum contains any reserved bytes they are replaced with a 2 byte sequence. Reserved Bytes 0x7D becomes 0x7F 0xFD 0x7E becomes 0x7F 0xFE 0x7F becomes 0x7F 0xFF Page 3

Data Field Commands are sent in the form Address Command Data 1 byte 1 byte N bytes All commands respond as follows Address Command Data 1 byte 1 byte OR 0x80 N bytes Page 4

Commands Command Number 0x00 Command Get Output Channel 0x01 Get Input Channel 1 0x02 Get Input Channel 2 0x03 Get Input Channel 3 0x04 Get Input Channel 4 0x05 Get Input Channel 5 0x06 Get Input Channel 6 0x07 Get Input Channel 7 0x08 Get Input Channel 8 0x09 0x0A 0x0B 0x0C Get System Settings Get Monitor Settings Get Status and Meters Set Output Channels 0x0D Set Input Channel 1 0x0E Set Input Channel 2 0x0F Set Input Channel 3 0x10 Set Input Channel 4 0x11 Set Input Channel 5 0x12 Set Input Channel 6 0x13 Set Input Channel 7 0x14 Set Input Channel 8 0x15 0x16 0x17 0x7F Set System Set Monitor Reset to Factory Defaults Get Version Page 5

Get Output Channels Command 0x00 2 Command 0x00 Get Output channels Response from MR88 2 Command 0x80 Get Output Channels Ack 3 Gain A 0xC4 0x00-60dB to 0dB 4 Gain B 0xC4 0x00-60dB to 0dB 8 Source A 0x00 0x03 0x00 = Off 0x01 = Channel X 0x02 = Channel Y 0x03 = Channel X+Y 9 Source B 0x00 0x03 0x00 = Off 0x01 = Channel X 0x02 = Channel Y 0x03 = Channel X+Y Example to get the output settings for mixer address 2 :- 0x7E, 0x02, 0x00, 0x7F, 0xFD, 0x7D The mixer would respond with, for example :- 0x7E, 0x02, 0x80, 0xFC, 0xF0, 0x01, 0x02, 0x8E, 0x7D Page 6

Get Input Channels All input channel Get commands are of the form 2 Command 0x01 0x08 Get Input Channel 1-8 Where command is Command Description 0x01 Get Input Channel 1 0x02 Get Input Channel 2 0x03 Get Input Channel 3 0x04 Get Input Channel 4 0x05 Get Input Channel 5 0x06 Get Input Channel 6 0x07 Get Input Channel 7 0x08 Get Input Channel 8 Page 7

Response from MR88 2 Command 0x81 0x88 Get Input Channel n Ack 3 Mono/Stereo 0x00 0x01 0x00 = Mono 0x01 = Stereo 4 Input Level 0x00 0x02 0x00 = Mic + Phantom 0x01 = Microphone 0x02 = Line 5 Input Gain 0xD8 0x14-40db +20dB 6 Compression 0x00 0x09 0 = Off 9 = Max 7 Eq Low 0xF4 0x0C -12dB +12dB 8 Eq High 0xF4 0x0C -12dB +12dB 9 Output to 0x00 0x03 0 = Off 1 = Bus X 2 = Bus Y 3 = Bus X and Bus Y 10 Priority Level 0x01 0x04 1 = Priority 1.. 4 = Priority 4 11 Gate Level 0x00 0x22, 0x23 6dB 40dB and Mute 12 Detector Type 0x00 0x04 0x00 = Auto Speech 0x01 = Auto Music 0x02 = Manual 0x03 = Force Off 0x04 = Force On 13 Manual Level 0xD8 0x00-40dB 0dB 14 Hold Time 0x00 0x05 0 = 50mS 1 = 100mS 2 = 200mS 3 = 500mS 4 = 1S 5 = 2S 15 NOMA 0x00 0x01 0 = Exclude from Noma 1 = Include in NOMA Page 8

Example to get the input settings for Channel 1 from Mixer address 3 :- 0x7E, 0x03, 0x01, 0xFB, 0x7D The mixer would respond with, for example :- 0x7E, 0x03, 0x81, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x03, 0x03, 0x01, 0x0C, 0x00, 0xEC, 0x02, 0x01, 0x79, 0x7D Page 9

Get System Command 0x09 2 Command 0x09 Get System Response from MR88 2 Command 0x89 Get System Ack 3 Priority 1 0x00 0x01 0x00 = Inclusive 0x01 = Exclusive 4 Priority 2 0x00 0x01 0x00 = Inclusive 0x01 = Exclusive 5 Priority 3 0x00 0x01 0x00 = Inclusive 0x01 = Exclusive 6 Priority 4 0x00 0x01 0x00 = Inclusive 0x01 = Exclusive 7 Last Channel On 0x00 0x01 0x00 = Disabled 0x01 = Enabled 8 Code 1 0x00 0x09 1 st Code digit 1-9 9 Code 2 0x00 0x09 2 nd Code digit 1-9 10 Code 3 0x00 0x09 3 rd Code digit 1-9 11 Code 4 0x00 0x09 4 th Code digit 1-9 12 Control Outputs 0x00 0x01 0x00 = High 0x01 = Low 13 Control Inputs 0x00 0x01 0x00 = Force off 0x01 = Force on Page 10

14 VCA 0x00 0x04 0x00 = VCA1 to OFF, VCA2 to OFF 0x01 = VCA1 to ChA, VCA2 to OFF 0x02 = VCA1 to ChB, VCA2 to OFF 0x03 = VCA1 to ChA+B, VCA2 to OFF 0x04 = VCA1 to ChA, VCA2 to ChB 15 Locked 0x00 0x01 0x00 = Unlocked 0x01 = Locked Example to get the system settings from Mixer address 2 :- 0x7E, 0x02, 0x09, 0xF4, 0x7D The mixer would respond with, for example :- 0x7E, 0x02, 0x89, 0x01, 0x00, 0x00, 0x00, 0x01, 0x02, 0x03, 0x04, 0x05, 0x00, 0x00, 0x00, 0x00, 0x64, 0x7D Page 11

Get Headphone Monitor Command 0x0A 2 Command 0x0A Get Monitor Response from MR88 2 Command 0x8A Get Monitor Ack 3 Left 0x00 0x09 Left channel source 4 Right 0x00 0x09 Right channel source 5 Gain 0xC4 0x00-60dB to 0dB Where left and right sources are Source Description 0x00 Input Channel 1 0x01 Input Channel 2 0x02 Input Channel 3 0x03 Input Channel 4 0x04 Input Channel 5 0x05 Input Channel 6 0x06 Input Channel 7 0x07 Input Channel 8 0x08 0x09 Output Channel A Output Channel B Page 12

Example to get the monitor settings from Mixer address 2 :- 0x7E, 0x02, 0x0A, 0xF3, 0x7D The mixer would respond with, for example :- 0x7E, 0x02, 0x8A, 0x01, 0x01, 0xEC, 0x85, 0x7D Page 13

Get Channel Meters and Status Command 0x0B. 2 Command 0x0B Get Status Response from MR88 2 Command 0x8B Get Status Ack 3 Channel 1 Meter 0xC4 0x0D -60 db +13 db 4 Channel 2 Meter 0xC4 0x0D -60 db +13 db 5 Channel 3 Meter 0xC4 0x0D -60 db +13 db 6 Channel 4 Meter 0xC4 0x0D -60 db +13 db 7 Channel 5 Meter 0xC4 0x0D -60 db +13 db 8 Channel 6 Meter 0xC4 0x0D -60 db +13 db 9 Channel 7 Meter 0xC4 0x0D -60 db +13 db 10 Channel 8 Meter 0xC4 0x0D -60 db +13 db 11 Output A Meter 0xC4 0x0D -60 db +13 db 12 Output B Meter 0xC4 0x0D -60 db +13 db 13 Enabled Channels 0x00 0xFF A 1 in the corresponding bit position indicates that the channel is detected and on. Bit 0 = Channel 1 Bit 1 = Channel 2 Bit 2 = Channel 3 Bit 3 = Channel 4 Bit 4 = Channel 5 Bit 5 = Channel 6 Bit 6 = Channel 7 Bit 7 = Channel 8 Page 14

14 Disabled Channels 0x00 0xFF A 1 in the corresponding bit position indicates that the channel is detected, but disabled. Bit 0 = Channel 1 Bit 1 = Channel 2 Bit 2 = Channel 3 Bit 3 = Channel 4 Bit 4 = Channel 5 Bit 5 = Channel 6 Bit 6 = Channel 7 Bit 7 = Channel 8 15 Overload 0x00 0x01 0x00 = No overloads 0x01 = An input or output channel is overloaded. Example to get the meter settings from Mixer address 2 :- 0x7E, 0x02, 0x0B, 0xF2, 0x7D The mixer would respond with, for example :- 0x7E, 0x02, 0x8B, 0x01, 0x00, 0x00, 0x00, 0x01, 0x02, 0x03, 0x04, 0x05, 0x00, 0x00, 0x00, 0x00, 0x62, 0x7D Page 15

Set Output Channels Command 0x0C 2 Command 0x0C Set Output Channels 3 Gain A 0xC4 0x00-60dB 0dB 4 Gain B 0xC4 0x00-60dB 0dB 5 Source A 0x00 0x03 0x00 = Off 0x01 = Channel X 0x02 = Channel Y 0x03 = Channel X+Y 6 Source B 0x00 0x03 0x00 = Off 0x01 = Channel X 0x02 = Channel Y 0x03 = Channel X+Y Response from MR88 2 Command 0x8C Set Output Channels Ack Example to set Gain A to 20dB, Gain B to 10dB, Source A to Channel X, Source B to Channel Y for mixer address 2 0x7E, 0x02, 0x0C, 0xEC, 0xF6, 0x01, 0x02, 0x0C, 0x7D The mixer would respond with :- 0x7E, 0x02, 0x8C, 0x71, 0x7D Page 16

Set Input Channels All Set input channel commands are of the form 2 Command 0x0D 0x14 Set Input Channel 1 8 3 Mono/Stereo 0x00 0x01 0x00 = Mono 0x01 = Stereo 4 Input Level 0x00 0x02 0x00 = Mic + Phantom 0x01 = Microphone 0x02 = Line 5 Input Gain 0xD8 0x14-40db +20dB 6 Compression 0x00 0x09 0 = Off.. 9 = Max 7 Eq Low 0xF4 0x0C -12dB +12dB 8 Eq High 0xF4 0x0C -12dB +12dB 9 Output to 0x00 0x03 0 = Off 1 = Bus X 2 = Bus Y 3 = Bus X and Bus Y 10 Priority Level 0x01 0x04 1 = Priority 1.. 4 = Priority 4 11 Gate Level 0x00 0x22, 0x23 6dB 40dB and Mute 12 Detector Type 0x00 0x04 0x00 = Auto Speech 0x01 = Auto Music 0x02 = Manual 0x03 = Force Off 0x04 = Force On 13 Manual Detector Level 0xD8 0x00-40dB 0dB Page 17

14 Hold Time 0x00 0x05 0 = 50mS 1 = 100mS 2 = 200mS 3 = 500mS 4 = 1S 5 = 2S 15 NOMA 0x00 0x01 0 = Exclude from Noma 1 = Include in NOMA Where command is Command Description 0x0D Set Input Channel 1 0x0E Set Input Channel 2 0x0F Set Input Channel 3 0x10 Set Input Channel 4 0x11 Set Input Channel 5 0x12 Set Input Channel 6 0x13 Set Input Channel 7 0x14 Set Input Channel 8 Response from MR88 2 Command 0x8D 0x94 Set Input Channel 1 8 Ack Page 18

Example to set Channel 1 to Mono, Line level, Gain 10dB, Compression 4, Eq low +6dB, Eq High 6dB, Output to bus Y, Priority 2, Gate level 20dB, Detector type Manual, Detector level 25dB, Hold time 200mS, NOMA Exclude for Mixer Address 2 :- 0x7E, 0x02, 0x0D, 0x00, 0x02, 0xF6, 0x04, 0x06, 0xFA, 0x02, 0x02, 0x16, 0x02, 0xE7, 0x02, 0x00, 0xEF, 0x7D The mixer would respond with :- 0x7E, 0x02, 0x8D, 0x70, 0x7D Page 19

Set System Command 0x15 2 Command 0x15 Set System 3 Priority 1 0x00 0x01 0x00 = Inclusive 0x01 = Exclusive 4 Priority 2 0x00 0x01 0x00 = Inclusive 0x01 = Exclusive 5 Priority 3 0x00 0x01 0x00 = Inclusive 0x01 = Exclusive 6 Priority 4 0x00 0x01 0x00 = Inclusive 0x01 = Exclusive 7 Last Channel On 0x00 0x01 0x00 = Disabled 0x01 = Enabled 8 Code 1 0x00 0x09 1 st Code digit 1 9 9 Code 2 0x00 0x09 2 nd Code digit 1 9 10 Code 3 0x00 0x09 3 rd Code digit 1 9 11 Code 4 0x00 0x09 4 th Code digit 1 9 12 Control Outputs 0x00 0x01 0x00 = High 0x01 = Low 13 Control Inputs 0x00 0x01 0x00 = Force off 0x01 = Force on 14 VCA 0x00 0x04 0x00 = VCA1 to OFF, VCA2 to OFF 0x01 = VCA1 to ChA, VCA2 to OFF 0x02 = VCA1 to ChB, VCA2 to OFF 0x03 = VCA1 to ChA+B, VCA2 to OFF 0x04 = VCA1 to ChA, VCA2 to ChB 15 Locked 0x00 0x01 0x00 = Unlocked 0x01 = Locked Page 20

Response from MR88 2 Command 0x95 Set System Ack Example to set mixer address 2 to Priority 1 exclusive priority 2 4 inclusive, Last Channel On = true, Code = 2345, Control outputs active high, Control inputs to Force off, VCA = off, Unlocked 0x7E, 0x02, 0x15, 0x01, 0x00, 0x00, 0x00, 0x01, 0x02, 0x03, 0x04, 0x05, 0x00, 0x00, 0x00, 0x00, 0xD8, 0x7D The mixer would respond with :- 0x7E, 0x02, 0x95, 0x68, 0x7D Page 21

Set Monitor Command 0x16 2 Command 0x16 Set Monitor 3 Left 0x00 0x09 Left channel source 4 Right 0x00 0x09 Right channel source 5 Gain 0xC4 0x00-60dB 0dB Where left and right sources are Source Description 0x00 Input Channel 1 0x01 Input Channel 2 0x02 Input Channel 3 0x03 Input Channel 4 0x04 Input Channel 5 0x05 Input Channel 6 0x06 Input Channel 7 0x07 Input Channel 8 0x08 0x09 Output Channel A Output Channel B Response from MR88 2 Command 0x96 Set Monitor Ack Page 22

Note if the left and right channels are set differently they must be to the same input or output channel pair. Example to set Gain A to 20dB, Gain B to 10dB, Source A to Channel X, Source B to Channel Y for mixer address 2 0x7E, 0x02, 0x16, 0x00, 0x01, 0xF6, 0x06, 0x7D The mixer would respond with :- 0x7E, 0x02, 0x96, 0x67, 0x7D Page 23

Set Defaults Command 0x17 2 Command 0x17 Set Factory Defaults Response from MR88 2 Command 0x97 Set Factory Defaults Ack Example to restore the factory defaults for mixer address 2 0x7E, 0x02, 0x17, 0xE6, 0x7D The mixer would respond with :- 0x7E, 0x02, 0x97, 0x66, 0x7D Page 24

Get Version Command 0x7F 2 Command 0x7F Get Version Response from MR88 2 Command 0xFF Get Version Ack 3 ID1 0x02 4 ID2 0x01 5 Hardware Version 0x00 0xFF Currently 4 6 Hardware State 0x00 0xFF Currently 2 7 Boot Version 0x00 0xFF Currently 1 8 Firmware Major 0x00 0xFF Currently 4 9 Firmware Minor 0x00 0xFF Currently 2 Example to get the version for mixer address 2 :- 0x7E, 0x02, 0x7F, 0xFF, 0x7F, 0xFE, 0x7D The mixer would respond with, for example :- 0x7E, 0x02, 0xFF, 0x02, 0x01, 0x04, 0x02, 0x01, 0x04, 0x02, 0xEE, 0x7D Page 25