APPLYING PROPER CABLE MANAGEMENT IN IT RACKS. A Guide For Planning, Deployment And Growth

Similar documents
SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Liebert XDA Air Flow Enhancer. User Manual

VERTIV VR RACK. Selection Guide

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

Liebert DCW CATALOGUE

SmartMod Intelligent, Integrated Infrastructure for the Data Center

Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

S-Series Superior Rack Solution for Data Centre & Network Closets

Vertiv Local Rack Access 18.5" LED LCD Console

DCF OPTIMIZED RACK SYSTEM. Selection Guide

Cable Routing Procedures for Dell PowerEdge T710 Systems

Aisle Containment Systems. Physical Containment Systems Selection Guide

ARE YOUR RACK PDUS KEEPING YOU FROM OPTIMIZING POWER MANAGEMENT?

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Cable Routing Procedures for Dell PowerEdge R630 Systems

Managing Density Managing Density in the Data Center: A Long-term Approach for the Future

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Vertiv VR Rack 1.0 GENERAL

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

V-Built Custom Preconfigured Solutions

THE CHALLENGES WITH A COLOCATION ROLL-OUT: And how to simplify the deployment and maintenance of IT equipment at the colocation facility

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

DATACOM CABINETS SOLUTION GUIDE

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Thermal management. Thermal management

A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution Architecture

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Knurr Miracel Server Rack

1. Unpacking the System

Site Preparation for ClearCube Installation. Rev. F

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

F-SERIES Innovative Rack Solution

Liebert. DCL up to 35 kw. Modular Rack Cooling

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks

Liebert. GXT3 5kVA-10kVA Compact UPS Systems For High Power Network Rack Applications

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Rack Selection Guide for NetShelter SX

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

15 Ways Belden Helps Reduce Human Error to Improve Uptime

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

InstaPATCH Cu Cabling Solutions for Data Centers

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

ENCLOSURE HEAT DISSIPATION

CRITICAL INFRASTRUCTURE ASSESSMENTS

ADDRESSING CHALLENGES TO POWERING SMALL TO MIDSIZE IT SPACES

Power and Cooling Design Guidelines for Network Access Rooms. A White Paper from the Experts in Business-Critical Continuity TM

V800 Cabinet Solution

Vertiv DCM Colocation Rack. Secure, Separate Server Hosting and Housing in Data Centers

UltraRack. Advanced Data Centre Enclosures SR SERIES

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

DCM Modular Rack System Advanced Features and Customizable Options For Unique Data Center Needs

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

Installing the Cisco MDS 9020 Fabric Switch

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

APC APPLICATION NOTE #146

THE NEW WORLD OF IT INFRASTRUCTURE SOLUTIONS. Enabling an IT Infrastructure as Dynamic as Your Business

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Liebert. MB Flexible Modular Busway

Total Modular Data Centre Solutions

Data center solutions for successful companies. cable management solutions

Preparing to Install the VG248

NetShelter SX Cable Management. Organize large volumes of cables from networking switches and patch panels

QuickSpecs. HP Rack Series. Overview. HP Rack Series - 36U

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

EF-Series EuroFrame Gen 2 Cabinet System

Data Centre Solutions

PACSystems RX7i IC698CHS009/119

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

POWER PRODUCTS AS INCLUDED IN OUR PLATINUM RESELLER, JEM TECH'S NY STATE CONTRACT

Rack Installation Instructions

Liebert. EXL UPS 800 and 1200kVA Single Module and Multi-Module Systems

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

DATA CENTER CABLING DESIGN FUNDAMENTALS

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Rack PDU Marketing Playbook

Rack & Enclosure Systems

DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications

Replacing the Power Supply

1.866.TRY.GLCC WeRackYourWorld.com

CommScope and Cisco - The ideal connectivity system for multilayer directors

TECHNOLOGY: THE COMPETITIVE ADVANTAGE FOR SUCCESSFUL RETAIL BUSINESS

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

HP Modular Cooling System: water cooling technology for high-density server installations

Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

Transcription:

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS A Guide For Planning, Deployment And Growth

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS Why Proper Cable Management Is So Important Your rack cabling systems are the lifelines of your IT operations. These cables handle critical circuits that must stay up and running. Any mishandling or excessive stress on these critical connection paths can have catastrophic results. Today s high-density rack-based IT server and switching installations provide higher and higher levels of performance and capacity. But with this growth of capability come a parallel growth of discrete data communications and power cabling that must be managed within the confine of these tightly spaced rack environments. Improper cable management can result in cable damage and failure. This can lead to data transmission errors and performance issues as well as system downtime. Data centers contain two basic types of equipment enclosures: server cabinets and network cabinets. Each of these has similarities and differences with specific cable management needs that must be addressed. It is important to follow recognized industry practices for cable management within these IT equipment enclosures. The problems created by poor cable management include: 1. Signal interference and crosstalk due to improper placement of data and power cables. Data and power cables running close to each other in parallel groups or in loops may create electromagnetic interference (EMI) due to induction. EMI can cause errors in data transmission over these cables. Whenever possible, power cables should be isolated from data cables on opposite sides of the rack to reduce the chances of EMI. 2. Excess power and data cabling that is improperly arranged and secured. Most IT racks will have varying lengths of cable resulting in the need to deal with excess cable. You should avoid simply bundling excess cable as this can often lead to EMI or even damage to the cable due to excess bends. There are preferred methods and cable management components for handling excess cable runs. 3. The chance of cable damage due to improper bends, movement or sharp edges. Installing cables within a tightly packed IT enclosure is going to require the bending of cables around components in the rack. The bend radius of these cables should be within the ranges specified for the type of cable being used. Any data cables and connectors exhibiting excessive movement should be secured and equipped with strain relief. Power cables and connectors should be securely installed to avoid any disconnection or arc flash hazard. Cables also need to be protected wherever there is a chance of contacting sharp edges or high heat. This is especially true with power cables where damaged or exposed conductors can result in downtime or safety concerns. 2

4. Rack-mounted components blocked by improperly routed cables. Access to servers and other network components housed within an enclosure is critical. Because of the high density of cabling in many of these applications, it is important that cabling does not block these components, racks or rails. Fiber optic cable presents additional challenges because of its more fragile nature. Care should be taken to avoid having other cables or components exerting tension on it to avoid damage. Velcro ties should be used to secure fiber optic cables. Try not to route fiber optic cable around corners within the enclosure. 5. Cooling and airflow restriction resulting from poor cable placement. It is important to make sure that cables are not placed in such a way that they restrict airflow from components inside the enclosure. Obstructed air movement due to blocked vents and fans can result in component overheating and possible thermal shutdown or even equipment damage. Benefits Of Cable Management Proper management of data and power cabling within an IT enclosure will deliver a number of benefits that will enhance your system availability and improve your bottom line. Reduced signal interference the elimination of crosstalk and interference between cables will enhance system performance. Improved maintenance and serviceability easier access to internal rack components reduces maintenance time and improves safety. Cooler performance cooling efficiency within the rack is enhanced thanks to proper positioning of cables to avoid air flow blockage. A roadmap for growth effective cable management solutions provide the ability to scale and adapt to changes in the IT infrastructure while minimizing service time. 6. Increased time and chance of error for maintenance, troubleshooting and cabling changes. Servicing network devices, as well as replacing and rerouting cables is unavoidable. To make this process easier, cables should be installed to enable quick access to discrete circuits. 7. Inability to make changes to equipment blocked by cabling without creating an outage. Cabling should not be placed in such a way that it must be disconnected to reach a piece of equipment for adjustments or other changes. 8. Problems with documentation for compliance as cabling becomes impossible to trace. Cables must be organized so that specific connections can be traced and validated for code compliance and other regulatory requirements. 3

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS Cable Management In Server Cabinets Vertical Cable Fingers 18U Part No. 010200078 with Cover - 2U 19 Part No. 548785P1 with Cover - 1U 19 Part No. 548784P1 Blade configuration Server cabinets house mostly active equipment in the form of blade chassis or stackable (aka pizza box) servers. Blade servers require both front and the rear accessibility. This makes it necessary to keep data and power cables to the sides of the cabinet. With blade servers, for example, up to 120 data cables could be used and up to 80 power cords. It is important to understand the number and type of connections per server and the total number of servers expected to be housed in a cabinet. 4 The first step of preparing cable management for the enclosure is to determine the capacity needed for cabling. Calculate the number and type of connections per server and the total number of servers expected to be housed in the cabinet and determine where the cable needs to be routed. Servers will generally have a primary and secondary network connection (typically copper), primary and secondary SAN (storage area network) connections which are typically fiber optic cables, and one or two management ports for in band and out of band management. There may also be another copper connection for KVMs (Keyboard, Video and Mouse connections). The ability to house these connections in the vertical patching space assures that cables are dressed in such a manner that they do not block exhaust fans on the rear of the servers. Swing arms are not necessary to dress cabling in the rear. In lower density situations, one vertical patching channel may serve two adjacent server cabinets.

Cabling requirements unique to server cabinets: yyserver cabinets typically have the patching for the devices occupying the rear-facing portion of the cabinet, along with power connections. This requires management of both network and power cords. The copper connections and fiber connections are served from one vertical bay, while power connections are addressed from another bay. yya mounting area is provided where vertical mounted power strips are used. In instances where power and network cords have to cross from one side of the cabinet to the other, the use of horizontal cable managers can be deployed to provide distinct paths. Note that power and network cords should each be housed in separate cable managers. yythe ability to house these connections in the vertical patching space assures that cables are dressed in such a manner that they do not block exhaust fans on the rear of the servers. yyswing arms are not necessary to dress cabling in the rear. In lower density situations, one vertical patching channel may serve two adjacent server cabinets. with Cover - 2U 19 Part No. 548785P1 Vertical Cable Fingers 18U Part No. 010200078 Tool-Less Cable Management - Lobster Claw Part No. 002185050 Part No. 002185070 Tool-Less Cable Management Velcro Strap Part No. 002185060 Part No. 002185080 Full Height PDU/Vertical Cable Manager Part No. 546076G1L 1U Server Configuration 5

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS Cable Management In Network Cabinets Network cabinets house network switches and patch panels. These cabinets have the highest concentration of cabling in the data center, making patch cord management even more critical and requiring both horizontal and vertical cable management. Determine the capacity needed for cabling by calculating the number and type of connections per component expected to be housed in the cabinet and establish where the cables need to be routed. Network cabinets contain edge and/or core switches and patch panels. Due to the high concentration of cabling in these cabinets, a typical installation would use 19 patch panels and standard fiber enclosures mounted either at the top of the switch cabinet or in some cases in an adjacent cabinet when the cabinet houses multiple switches. The network cabinet would be populated with cable management, for both copper and fiber connections. The majority of the patching connections typically occur at Cisco Nexus 7010 application Vertical Cable Backplane Part No. 546550P1 Part No. 546553P1 Vertical Cable Fingers 18U Part No. 010200078 with Cover - 1U 19 Part No. 548784P1 with Cover - 2U 19 Part No. 548785P1 Vertical Cable Cover Part No. 546545P1 Part No. 546547P1 Additional Accessories to use: Lobster Claw Velcro Strap Metal Blanking Panel with Brush 6 the front of the cabinet. For in row switching or top of rack switching, the set back-side rails populated with horizontal cable managers allow patching within the cabinet and down the row. Typically these cabinets would be configured in a manner using rack mount patch panels and cable managers along with vertically mounted cable managers to provide pathways for patch cords transcending from top of rack patch panels to bottom of rack switches.

Cisco 7018 Network application Vertical Cable Fingers 18U Additional Accessories to use: Part No. 010200078 Lobster Claw with Cover - 1U 19 Velcro Strap Part No. 548784P1 with Cover - 2U 19 Part No. 548785P1 Cable management situations to address in network cabinets: Power and network cables must be separate to avoid crosstalk and electro-magnetic interference. Proper routing of cables within cabinet to avoid blockage of network components that require adjustments or maintenance. Cable bends need to be within recommended specifications to avoid cable damage. Cables need to be protected cables must be kept away from sharp items as well as high heat areas within the cabinet. Proper handling of excess lengths of cable ensure that excess lengths of cable are properly run to avoid excess bends or interference issues. Metal Blanking Panel with Brush Plastic Blanking Panels Cabling requirements unique to network cabinets: yythe majority of the patching connections typically occur at the front of the cabinet. yyfor in row switching or top of rack switching, the set back side rails populated with a horizontal cable managers allow patching within the cabinet and down the row. yytypically these cabinets would be configured in a manner using rack mount patch panels and cable managers along with vertically mounted cable managers to provide pathways for patch cords transcending from top of rack patch panels to bottom of rack switches. Cables and connectors should be secured this will help to avoid excess movement, accidental disconnection or potential shorts. Identification of cables this is critical during cable installation as well as when making future changes and upgrades. 7

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS Vertiv offers a wide variety of cable management components for use in both our DCM and DCF rack systems: 19 1U Metal Blanking Panel with Brush Provides cutouts for cable pass through or mounting. PART NUMBER 542190G1L USE WITH DCM, DCF 19 1U Cable Routing Panel with D rings Facilitates cable routing within the enclosure. PART NUMBER USE WITH 011171448 DCM, DCF Vertical Cable Fingers 18U - Kit of Two With 1U center spacing, mount tool-lessly on 19 rails. PART NUMBER USE WITH 010200078 DCM, DCF Tool-Less Cable Management - Lobster Claw Provides versatile cable management within the cabinet. PART NUMBER DESCRIPTION USE WITH 002185050 Package of 10 DCM, DCF 002185070 Package of 100 DCM, DCF Tool-Less Cable Management Velcro Strap Provides versatile cable management within the cabinet. PART NUMBER DESCRIPTION USE WITH 002185060 Package of 10 DCM, DCF 002185080 Package of 100 DCM, DCF 19 Tool-Less Blanking Panel PART NUMBER DESCRIPTION 010200087 1U Plastic Tool-Less Blanking Panel; Box of 10 010200088 2U Plastic Tool-Less Blanking Panel box of 5 8

Vertical Cable Cover - Two Pieces Protects cables inside cabinets. PART NUMBER DESCRIPTION USE WITH 542970P1 18U 600-700mm DCM 542971P1 18U 600-800 & 700-700mm DCM 542972P1 18U 700 to 800mm DCM 542973P1 18U 800-800mm DCM 546545P1 18U 600-800mm DCF 546547P1 18U 800-800mm DCF Vertical Cable Backplane - Two Pieces Routes cables inside cabinets. PART NUMBER DESCRIPTION USE WITH 542974P1 18U 600-700mm DCM 542975P1 18U 600-800 & 700-700mm DCM 542976P1 18U 700-800mm DCM 542977P1 18U 800-800mm DCM 546550P1 18U 600-800mm DCF 546553P1 18U 800-800mm DCF with Cover Routes and protects cables inside cabinets. PART NUMBER DESCRIPTION USE WITH 548784P1 1U 19 DCM, DCF 548785P1 2U 19 DCM, DCF Full Height PDU/Vertical Cable Manager Full height PDU mounting bracket, 4 wide. Holds two 2 wide max PDU s with Quick Mount button system (all Knurr DI-STRIP and Liebert MPH listed in catalog). PART NUMBER DESCRIPTION USE WITH 539486G1L 42U 4 Wide DCM 539487G1L 45U 4 Wide DCM 546076G1L 42U 4 Wide DCF 546077G1L 48U 4 Wide DCF 9

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS Power And Cooling Solutions For Your Row-Based IT Infrastructure Vertiv offers a complete range of row-based power protection, power distribution and cooling systems for your IT infrastructure. We lead the industry in infrastructure support, with a comprehensive offering that provides efficient operation without compromising availability. These solutions are backed by the industry s largest service organization, ensuring continued support by factory-trained experts. IT Racks and Accessories Rack PDUs ybasic, controlled or adaptive designs. ylocal and remote monitoring. yadditional in-rack sensors available. yavailable in low and high density. y2-year no-hassle replacement warranty. Aisle Containment from Vertiv yflexible design independent from rack width. ysliding or vertical doors. ymodular, vertical or retractable overhead containment. yintegrated adaptive control reduces fan energy cost. Liebert MB Modular Busway ytool-less mounting to Knurr racks. yplug-n-play bus plug/rack PDU connections. yreplaces multiple power cables. yavailable in dual bus design. Power and UPS Liebert APM UPS yscalable capacity growth without increasing footprint: 15-90kW. yoperates with up to 94% energy efficiency. yrow-based installation. Liebert NX UPS yscalable capacity growth without increasing footprint: 40-200kVA. yparallel configurations for capacity or redundancy. yoperates with up to 97% energy efficiency. yrow-based installation. Liebert FDC / Liebert FPC yrack-size power conditioning and distribution. yrequires only front and back service access. yoffers top or bottom cable entry. Precision Cooling Liebert CRV Row- Based Cooling y20kw to 40kW precision cooling with horizontal airflow design for both non-raised and raised floors. ydigital scroll compressor and variable speed fans for highly efficient operation. yair, water, glycol and chilled water designs. y Liebert icom for intelligent control, communications and monitoring. 10

Tips For Specifying And Applying Cable Management Products 1. Start with proper planning Once you have determined the amount of cabling and connections required, you can decide where the cables need to be routed within the cabinet. This will then allow you to select the proper cable management components needed to properly secure the all of the wiring and connections. It is important to make sure that there will be adequate space within your rack for the amount of cabling to be used. Accurately establishing the amount of cabling and connections needed ahead of deployment will greatly improve the chance of a successful installation. 2. Keep growth in mind Growth in the data center environment is a certainty. Planning ahead for installing additional cabinets, servers and network components should be taken into consideration even as you are installing the first phase of your racks. This will make it easier to integrate additional racks and components in the future. Poor planning in terms of future changes can often result in the spaghetti of wiring present in many data centers. Data center standards recommend not only installing cable for present needs, but also anticipated future growth that has been identified. Accommodating growth and building in flexibility is a key challenge to data center operators. Proper planning for the future will help avoid cabling issues down the line. 3. Change is inevitable Your rack installations may change configurations a number of times during their life cycles. Properly installed cables will help facilitate change-outs and other component additions and movement within the rack environment. This can also minimize the risk of technicians accidently unplugging components that must not be taken off-line such as switches or critical servers. Identifying cables that need to be moved can also pose a challenge. Verifying proper connectivity, troubleshooting, and managing device changes can become more complex and time-consuming without accurate cable identification and can lead to unplanned downtime of critical business applications. 4. Follow industry standards Industry guidelines, such as ANSI/TIA and ISO/IEC, as well as any federal, state or local regulations regarding cabling should always be followed. This not only assures code compliance but promises a safe, failure-free installation that will minimize system downtime and data errors. A standards-based cabling system will provide the best combination of reliability today and the ability to change and reconfigure in the future. Standards provide a written foundation for establishing a sound infrastructure and guidelines for maintaining a high level of cable performance. 11

VertivCo.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2016 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. SL-11364 (R10-12)