LOAd def. The display load defaults appears after choosing to load the default values for approx. 5 sec.

Similar documents
Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

Index. 07/15 Subject to technical changes. Temperature controls. Page. DP1 / 2 Controls DP3 / 5 DP6 9.1.

OVEN INDUSTRIES, INC.

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

GÜNTHER Hot Runner Systems

GIR 230 TC Version 1.1

Description TR D

Thermoelectric Cooler Controller TED1000

Intrinsically safe batch controller Batching Master 110i

SK CU4-ECT-C Part number:

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

ProMinder Standard Heating System Installation Instructions

Operation Manual Series W-500

Operating instructions Evaluation system for flow sensors VS / / 2013

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

Dialock DT Lite. Operating instructions...2. Operating instructions

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

18W Round LED Bulkhead Light with Microwave Sensor

Operating instructions. ProcessLine analogue module AC / / 2012

INFRARED PRE HEATER

AE25-DPP OPERATION INSTRUCTIONS

SMARTHOME RC-plus next 230 ZW

GCI-5K INSTALLATION AND OPERATOR S MANUAL

SK CU4-EIP-C Part number:

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER BATTERY MONITOR

Manual Control Unit GFC 32

Quick Start Installation and User Manual

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

Operating manual Solareg II BASIC

DLB1248 single channel EASY-BLE

TEC 2000 INSTRUCTION MANUAL TEC SERIES

GMH to 1300 mbar absolute Version 4.7

Operating Instructions. November 2008 (Subject to technical modifications) PROFESSIONAL. HUMMEL AG Geschäftsbereich EL

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Manual Simatek Control Unit GFC 32

PMSW12 12 Position Selector Switch Operation and Instruction Manual

2x 10W LED Slimline PIR Floodlight Twin Flood

Cube67 - Modular I/O station

ERC 21X Modbus parameter

Controller Smart Box Translation of operating and installation instructions

Operating Manual Digital Quick Response Thermometer GMH 3210 For Thermocouple Probes Type J, K, N, S, T from Version 1.0

RT4F-120V/20A-WAC RECTIFIER

REGARD mA output module. Installation, operation and maintenance

Operation and Settings of CPU & Power Modules, series 9440

PTC/PT100 board 2.0 Option

Mini Environmental Quality Meter

RT4F-48V/50A-WAC RECTIFIER

PTC/PT100 board 2.0 Option

Magnum Club Smoke System

HPS-C-S Hotrunner Controllers Operating manual for multi-zone controllers. Item-numbers:

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Advanced Thermal Controller TEC Series

DS-1312 USER'S MANUAL

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

HPS-C-PRO Hotrunner Controllers. Operating Manual. Valid for

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Type K/J Thermometers

Products no longer available

Safety Temperature Limiter TT-STL 50

Ethernet / RS485 Gateway

Mold Control Systems, Inc.

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

Installation and User Guide

GIR 230 FR Version 1.1

Operating manual Solareg II BASIC DC

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Pulsar EXtreme 2000/3000 VA

Basic User and Installation Manual

Thermal DC-DC Control System TEC Series

Rev Single-Channel Pulse Modulating Anti-Sweat Control (SC-PMAC) Installation and Operation Manual

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Operating manual Solareg II ENERGY

Portable Temperature Calibrator QUARTZ Dry Block Calibrator -50 C C

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Operating Instructions VEGAMET 381

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

ACS-30-EU-MONI-RMM2-E

Supplied with. Calibration certificate. TM 200 Thermometer

Therma-Stor LLC Model LM in-1 Pocket Thermo-Anemometer, Hygrometer, Thermometer & Illuminometer. Instruction Manual.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Tempco Instruction Manual

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

Delta T Dew Heater for CDK

Pull Cord Time Delay Switch 3-wire version

Page Series TECSource User s Manual

masibus : UT-94 Page 1 of 6 INTRODUCTION SPECIFICATIONS Dimensions Document Ref No. m98a/om/101 Issue No: 08

PEM Faults and Blower Failures

Operating Manual. Micro-Ohmmeter VG-CS200 VG-CS300 VG-CS400 VG-CS600

Temperature/Process Meter

GIA 20 EB / PK as of version 2.5

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

CONFIGURATION HANDBOOK

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

SVM F4. Node. Calculator. Installation Guide

INCOE I Series IC-15A Temperature Control Module Quick Start Manual

GSM HOME SECURITY SYSTEM

Communication Register Map - Uniflair Cooling

Transcription:

display meaning LOAd def. The display load defaults appears after choosing to load the default values for approx. 5 sec.

display No Sens Pol. th.1 Note Err. th.1 t.hi Ch1 Err. Temp meaning Thermocouple failure A thermocouple is unconnected or interrupted on one wire. Please check the wiring of your thermocouple! Polarity error at thermocouple connection Polarity error at the connection of thermocouple of control circuit 1. The thermocouple seems to be connected with wrong polarity. Please check the wiring of your thermocouple! After confirming the fault report thermocouple failure or polarity error at thermocouple connection with key F, the DP1/DP2 switches into percentage control mode automatically. If the user solves the problem before confirming with key F, the controller remains in thermocouple control mode.. Thermocouple short circuit A short circuit in control circuit 1 has occurred. This fault can be detected after a period of min. 90 sec.. Please check the wiring of your thermocouple! Over temperature The temperature of control circuit 1 crosses the security mark. The max. allowed temperature can be adjusted as system parameter and is standardly set to 500. Ambient temperature above limit The unit detected an ambient temperature of above 70 C.

display quit SoFt red reda ConF meaning exit menu By selecting quit the parameter menu is closed. To return to the normal operating level, press key A1 or B1. If for approx. 10 seconds no key is pressed, the parameter menu is quit automatically.. softstart By entering the menu SOFT the softstart function for 230V nozzles is selected. Within this parameter it is possible to enable or disable the softstart function. set value lowering The menu item set value lowering ( red. or red.a ) enables the user to set the lowering temperature or the lowering current. The function is switched on by pressing keys A1 and F simultaneously. configuration menu The menu item configuration menu ( CONF. ) enables the user to enter the configuration menu. This menu is protected by a password. Please refer to the chapter 3.2 for further information on the configuration menu.

display ConF ------ PId 1 PId 2 Unit meaning Konfigurationsmenü The parameter menu leads to the configuration menu ( CONF. ). To start the configuration menu, the password has to be entered. Consider that the digits of the password have to be entered starting right (!) by pressing key A1 or B1. Enter by pressing key F. PID-parameters The item PID1 allows to change the PID regulation parameters for each zone manually. At the two zone controller DP2 there is a second menu item to select the PID parameters for the second zone. temperature unit In this menu item the temperature unit can be chosen ( C or F). Hour counter operating time In the menu item hour the operating hours are listed. SYS quit Systemparametermenü After entering the menu item sys, the system parameters of the DP1/DP2 can be changed. The menu is protected by a password and enables the user to set and change all system parameters. Changes of the system parameters should only be carried out by authorised and qualified personnel. If the manual configuration of the system parameters is inadequate or faulty, it is possible to load the standard default values as described in chapter 2.5 Load defaults. exit menu By selecting quit, the parameter menu is closed. To return to the normal operating level, press key A1 or B1. If for approx. 10 seconds no key is pressed, the parameter menu will be quit automatically.

zone 1 2 load 1 (phase) 1 3 load 2 (neutral) 2 4 thermo + 6 8 thermo - 7 9

fault/defect possible cause countermeasure A Fault report no sensor 1 Thermocouple of zone 1 or 3 defect Thermocouple not connected or interrupted Check connection plug and -cable of thermoelectric couple B Fault report no sensor 2 Thermocouple of zone 2 or 4 defect Thermocouple not connected or interrupted Check connection plug and -cable of thermoelectric couple C Fault report Pol. TH 1 Polarity error at thermocouple of zone 1 or 3 Polarity error at thermocouple Correct the polarity D Fault report Pol. TH 2 Polarity error at thermocouple of zone 1 or 3 Polarity error at thermocouple Correct the polarity E Significant fluctuation of temperature (+/- 100 C ) Thermocouple defect or load circuit not earthed Check earthing of load circuit F Temperature increase not satisfactory Load circuit (swapped) Check assignment of heater circuit to thermoelectric couple