LDC-1C LED Controller Installation and Operation Manual

Similar documents
Multimode Laser-532 Installation and Operation Manual

Installation and Operation Manual Document Number

Installation and Operation Manual Document Number

Absolute Irradiance Installation and Operation Manual

ecovis Krypton Light Source Installation and Operation Manual Document Number

Blue LED Pulsed Light Source LS-475. Installation and Operation Manual Document Number

User Manual. pe-100 fiber. DOC-014 Iss 3 1

Spirit Sampler Installation and Operation Manual

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Torus Concave Grating Spectrometers Installation and Operation Manual

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Liebert MicroPOD 230V

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Ball Probe Moisture Meter With Bluetooth

Power Prowler USER MANUAL PLR In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables.

Gavita Master Controller EL1

Startup Guide C01

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

CUBE. Diode Laser System. Superior Reliability & Performance

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

NOVO-GLOSS. Flex 60. Operating Instructions. English

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

ADC2000-PCI A/D Converter Operating Instructions

User Manual. Cobia Flex R/F English - v2016.5a

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

User s Guide KODAK DP900 / DP1100 Digital Projectors

Accessory GP-EXT. EXTERNAL USB PRINTER User's Manual

1519L Multifunction 15-inch Desktop Touchmonitor

OWC Mercury On-The-Go Pro USER GUIDE

GE A Acoustic Belt Tension Tester. User s Operation Manual

Manual Version: V1.00. Video Decoder Quick Guide

16-SLOT IN-BAND MANAGEMENT CHASSIS

EMSwitch RF Switch Plug-In Card

EPS Power Supply

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

CF3000 Dealer Diagnostic Tool Instruction Manual

burst laser

User Manual. For more information, visit

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

Spectro-115E TM and Spectro-115U TM Spectroelectrochemical System. Operator s Manual

4200-DL Model # C-4200-DL DL Controller Instruction Manual V.1.0. This instruction manual serves as a guide for the 4200-DL Controller.

Mini Digital Multimeter

User Manual SP2H2A-H2. HDMI 2.0 1x2 Splitter with Audio Breakout. All Rights Reserved. Version: SP2H2A-H2_2018V1.0

4170 POS System Installation Guide

USER MANUAL. Elo Touch Solutions 2D Barcode Scanner Peripheral

LevelOne KVM User Manual. 17 Modularized KVM Console V

Line Impedance Stabilization Network (LISN)

DF-G2 High Speed Expert Dual Display Small Object Counter

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

HCC-CW-201A. CWDM Analyzer. Operation Guide

FOCIS Flex Inspection

PF LED Profile. User Manual

FTE-6000 Hand Held Tuneable Laser Source

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

Powerware 3105 UPS User s manual

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

EOS-6000 Series Optical A/B Switch User Manual DC Version

Optical DVI Module. User s Manual M1-2R2-TR. Doc No. : OEB-D R2 / Rev2.6

Powerware 3105 UPS User s manual

User Guide. Control Box. RoscoLED TM.

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

User Operation Manual: Motorized Valve Controller for Valved Sources

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

Rack Power Distribution Unit AP7530, AP7540

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

LevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

TRC-190 User s Manual

USERS GUIDE MCX-STH. 3G SDI to HDMI Converter. Manual Number:

Express All-Fiber DVI. User s Manual (For M1-1000)

Register Your Planar Products Today

Mercury Elite Pro mini ASSEMBLY MANUAL & USER GUIDE

Scanning Monochromator (MonoScan2000) Installation and Operation Manual Document Number

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

TRC-190 User s Manual

MVCI Cable User Manual X-Horse Electronics Co., Ltd.

4200 Model # - C Controller Instruction Manual V.3.1. This instruction manual serves as a guide for the 4200 Controller.

Perle MCR200 Installation Guide

AquaController Apex Probe Module 2

850VA 480W Line-Interactive UPS with 6 C13 Outlets - AVR, 230V, C14 Inlet, LCD, USB, Tower

Remote Divert User Interface DI. Instruction Manual

1902L 19-inch LCD. Product Overview. Touchscreen Monitor. Edge-to-edge design with integrated 10-touch

Folding Rackmount Console

Dolphin ebase. Communication Cradle for the Dolphin 9700 Mobile Computer. User s Guide

T1/E1 Channelized Gigabit Router

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

TVAC25100 TVAC25110 User manual

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

UV Power Flood. User Manual. Order code: EQLED029

Internet Office 120V 550VA 300W Standby UPS, Ultra-Compact Desktop, USB

Transcription:

LDC-1C LED Controller Installation and Operation Manual Document: 27-MNL-LDC-1 Version: 1.0

AMERICAS & WORLD HEADQUARTERS Phone: +1 727-733-2447 Fax: +1 727-733-3962 Sales: Orders: Support: info@oceanoptics.com orders@oceanoptics.com techsupport@oceanoptics.com EUROPE, MIDDLE EAST & AFRICA Phone: +31 26-319-0500 Fax: +31 26-319-0505 Email: info@oceanoptics.eu Germany : +49 711-341696-0 UK : +44 1865-811118 France : +33 442-386-588 ASIA Phone: +86 21-6295-6600 Fax: +86 21-6295-6708 Email: asiasales@oceanoptics.com Japan & Korea: +82 10-8514-3797 Ocean Optics, Inc. 8060 Bryan Dairy Road. Largo, FL 33777 USA Manufacturing & Logistics 4301 Metric Dr. Winter Park, FL 32792 USA Sales & Support Geograaf 24 6921 EW Duiven The Netherlands Manufacturing & Logistics Maybachstrasse 11 73760 Ostfildern Germany Ocean Optics Asia 666 Gubei Road Kirin Tower Suite 601B Changning District Shanghai PRC, 200336 www.oceanoptics.com Copyright 2018 Ocean Optics, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from Ocean Optics, Inc. Trademarks All products and services herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners. Limit of Liability Every effort has been made to make this manual as complete and as accurate as possible, but no warranty or fitness is implied. The information provided is on an as is basis. Ocean Optics, Inc. shall have neither liability nor responsibility to any person or entity with respect to any loss or damages arising from the information contained in this manual. ii 27-MNL-LDC-1

Table of Contents Table of Contents...iii About This Manual... iv Document Purpose and Intended Audience... iv Document Summary... iv Product-Related Documentation... iv Upgrades... iv Important Safety Notices... v Warranty... v Certifications and Compliance...vi Chapter 1... 1 Overview... 1 Unpacking the LED Equipment... 2 Contents... 2 Additional Accessories... 2 Components... 3 Front Panel... 3 Side Panel... 3 Rear Panel... 4 LSM... 4 Chapter 2... 6 Specifications... 6 Unit Specifications... 6 Operating Environment... 6 Parts List... 7 Chapter 3... 8 Operating Instructions... 8 Connecting the LDC-1C Controller and Light Source... 8 Navigating the LDC-1C... 8 Configuring the LDC-1C... 9 Configuration Settings...11 Information...16 Chapter 4...17 Troubleshooting and Maintenance...17 Warning Messages...17 Touch Screen Verification...18 FAQs...18 LED Replacement...19 Index...20 27-MNL-LDC-1 3

About This Manual About This Manual Document Purpose and Intended Audience This document describes the LDC-1C and provides you with an installation and operation section to get your LED system up and running. Document Summary Chapter Chapter 1: Overview Chapter 2: Specifications Chapter 3: Operating Instructions Chapter 4: Troubleshooting and Maintenance Description Contains a list of package contents and unpacking instructions. Also describes the components on the front and back face of the unit. Contains operating environment specifications, as well as other physical details of the product. Provides instructions for operating the LDC-1C and the LED Light Source Modules Contains Frequently Asked Questions (FAQs) and bulb replacement information. Product-Related Documentation You can access documentation for Ocean Optics products by visiting our website at http://www.oceanoptics.com. Select Support Documents, then choose the appropriate document from the available drop-down lists. Ocean Optics offers a Glossary of spectroscopy terms to help you further understand your state-of-the-art products and how they function, located at: http://oceanoptics.com/glossary/. Upgrades Occasionally, you may find that you need Ocean Optics to make a change or an upgrade to your system. To facilitate these changes, you must first contact Customer Support and obtain a Return Merchandise Authorization (RMA) number. iv 27-MNL-LDC-1

About This Manual Important Safety Notices 1. Do not remove or modify any installed safety device on this equipment. Doing so will void your warranty and create an unsafe operating environment. 2. There are NO user serviceable parts inside the device. 3. Only allow qualified personnel to operate this unit. 4. Do not use the unit if it is damaged in any way. Contact your dealer for repair or replacement information. 5. Always screw in the fiber optic cable to the LSM before starting the instrument. WARNING Protective eyewear must be worn when using light source modules. Never look directly into the light beam, as this can cause eye damage. Warranty The LDC-1C is covered by Ocean Optics Exclusive Three Year Warranty. For details, please visit the following webpage: https://oceanoptics.com/wp-content/uploads/warranty-sheet.pdf This instrument should not be used for any Clinical or Diagnostic purposes. Data generated in these areas is not warranted in any way by Ocean Optics, Inc. 27-MNL-LDC-1 v

About This Manual Certifications and Compliance ISO CERTIFICATION Ocean Optics, the industry leader in miniature photonics, has been certified for ISO 9001:2008 applicable to the design and manufacture of electro-optical equipment since 2009. WEEE COMPLIANCE The WEEE symbol on the product indicates that the product must not be disposed of with normal household waste. Instead, such marked waste equipment must be disposed of by arranging to return to a designated collection point for the recycling of waste electrical and electronic equipment. Separating and recycling this waste equipment at the time of disposal will help to conserve natural resources and ensure that the equipment is recycled in a manner that protects human health and the environment. vi 27-MNL-LDC-1

Chapter 1 Overview Ocean Optics LED Current Driver Controller (LDC-1C) is a compact single channel driver and controller for a next generation of LED Light Source Modules (LSMs). The LDC-1C is an easy to use, menu driven device. It automatically reads identification and operational information stored in the LSM and configures itself appropriately, thereby protecting the LSM from potential damage due to excessive current. The LDC-1C is fully self-contained; no external input device is required for operation. The LDC- 1C may also be connected to an external source such as a function generator or a modulation signal from a spectrometer or other electronic device.. LDC-1C LED Current Driver Controller 27-MNL-LDC-1 1

1: Overview The following sections provide instructions on unpacking and setting up your LDC-1C controller and LSMs. Unpacking the LED Equipment Procedure 1. Unpack your LED controller and lamp module(s) carefully. 2. Inspect the outside of the devices and make sure that there is no damage. Do not use the device if damage is present. 3. Use this instrument in a clean laboratory environment. Contents Your LED Controller package contains the following: LDC-1C LED Current Driver Controller Power cord Cable for connecting to LSM LDC-1C Quick Start Guide Additional Accessories The following are additional accessories available from Ocean Optics that you may need, depending on your system set-up: Rack mount wings for attaching to a 19 2U rack (LDC-RACK-2U) DIN rail clip for LDC-1C and LSM (LDC-1C-DIN) WARNING The beam emerging from the LSMs below 400nm contain UV radiation that can cause serious eye injury upon direct contact with the eye and UV safe eye protection should be worn if there is the possibility of exposure to the emissions of these devices when energized. Never look directly into the light source regardless of the wavelength attached. The body of the LSMs and the SMA 905 Connector may get hot during operation. After lamp use, allow sufficient time to cool before handling. There are no user-serviceable parts inside. Never open the unit. 2 27-MNL-LDC-1

Components 1: Overview Components located on the front, rear and side panels of the LDC-1C unit are described below. Front Panel Touchscreen Micro USB Connector Component Touchscreen Micro USB connector Description A multi-function display used for both a graphical display of LSM current as well as providing an input method for selecting desired functions. Provides access for loading firmware to the controller. Side Panel On-Off Switch Component On/Off Switch Description Applies power to the LDC-1C. (This does not turn on the LSM.) 27-MNL-LDC-1 3

1: Overview Rear Panel BNC Jack LSM Connector Power Connector Component LSM Connector Power Connector Description 7-pin locking connector for cable to the LMS. Input terminal for power cord. Note: Only connect the power cable to the controller when the On/Off Switch is in the OFF position. 50 ohm BNC Jack External Signal Mode - allows an external source such as a function generator or a modulation signal from a spectrometer or other electronic device to be attached. Internal Signal Mode outputs frequency of waveform to an external device. LSM Your LDC-1C has been designed to operate seamlessly with Ocean Optics LED Light Source Modules (LSMs). The diagram below shows the connectors on the LSM. Mounting Point SMA Connector (with screw-on cover) Interface Connector 4 27-MNL-LDC-1

1: Overview Component SMA 905 Connector Description Connects light source to sample cuvette holder. Interface Connector Mounting Point Connects LSM to the LDC-1C. Allows attachment to a standard optical bench with ¼-20 screws. 27-MNL-LDC-1 5

Chapter 2 Specifications This section provides information on the specifications, operating environment, and parts list for LED controller. Unit Specifications Dimensions 90.8mm L X 142.6mm W x 87.5mm H Weight 0.82 kg Power requirements 15 VDC wall transformer (included) Power consumption 2A (maximum) at 15 VDC BNC Source Current when Output 150mA maximum @ 3.3V 100mA @5V Operating Environment Humidity 95% Relative humidity, non-condensing Altitude 0 m to 3050 m (0 ft. to 10,006 ft.) Temperature 0 C to 35 C (+32 F to +95 F) 27-MNL-LDC-1 6

2: Specifications Parts List Part Number LDC-1C LDC-CABLE LDC-RACK-2U LDC-1C-DIN Description LED Current Driver Controller, single channel Replacement cable to connect LDC-1C and LSM 19 2U rack mount attachment Clip for 35mm DIN Rail 27-MNL-LDC-1 7

Chapter 3 Operating Instructions Connecting the LDC-1C Controller and Light Source Follow the steps below to set up your LDC-1C and LSM for use. Procedure 1. Insert the appropriate plug into the 15 VDC power supply. 2. Plug the power supply into a power outlet, then connect the barrel connector of the power supply to the power input on the rear of the LDC-1C. 3. Connect the LDC-1C to the LSM using the provided cable. The connectors on both the LSM and LDC-1C are keyed to facilitate the correct attachment. 4. Connect a fiber cable to the SMA 905 connector on the LSM and then attach to your sample. 5. Move the On/Off switch on the side of the LDC-1C to the On position. The Touchscreen will display the main screen. 6. Optionally, you may connect an external source such as a function generator or other input signal to the BNC connector on the rear of the LDC-1C. Your LDC-1C is now ready for use. Navigating the LDC-1C Navigating the menus on your LDC-1C is accomplished via the touch screen icons. The table below describes each of the icons. You may use your finger or a soft tipped stylus for selecting items on the touch screen. Do not use a sharp instrument as this will damage the touch screen. 27-MNL-LDC-1 8

3: Operating Instructions Touch Screen Icons LSM OFF/ON - Applies current to the LSM LIGHT OFF - Turns display off. Touching anywhere on the screen will resume the display. DOWN TRIANGLE - Reduces value in selected field UP TRIANGLE - Increases value in selected field SCROLL ARROWS Scrolls to display additional information INFORMATION Displays information on LSM and LDC-1C SETTINGS - Configuration Settings for the LDC-1C SOUND ON/OFF - Turns audible feedback on/off CHECK Accepts input CANCEL Abandons any changes that were entered DISPLAY MODE INDICATOR Allows the user to select if current input is in Percent Mode or Current Mode Configuring the LDC-1C The LDC-1C is easily configured via a series of menus displayed on the touch screen. When the LDC-1C is powered on, the main screen is displayed. 27-MNL-LDC-1 9

3: Operating Instructions Depending on the waveform type that has been selected (see Configuration Settings), you may change the Current, Frequency and Duty Cycle for your test. The table below shows which parameters can be changed via the touchscreen based on the selected waveform. Parameter Internal DC Internal SINE Wave Internal TRIANGLE Wave Internal SQUARE Wave External Signal Current Yes Yes Yes Yes Yes Frequency No Yes Yes Yes No Duty Cycle No No No Yes No Values for Current, Frequency and Duty Cycle may be changed by using the UP/DOWN TRIANGLES in the menu bar, or by keypad entry. To change a value using the icons, doubletap the box of the desired component. If the double-tap occurs in the Frequency or Duty Cycle box, the box will be highlighted as shown below. If a box is not highlighted, Current is selected by default. Press or in the menu bar to increase or decrease the value. To change the value via a keypad, touch and hold the Current, Frequency or Duty Cycle box on the touchscreen for 2 seconds. The appropriate keypad will be displayed. 10 27-MNL-LDC-1

3: Operating Instructions Enter the desired value and press to save it. The Current keypad also will indicate if the value being entered is a percentage of the maximum allowed current (% of Max) as shown in the keypad below, on the left. When this indication is not present, as shown in the keypad on the right, the value being entered is in milliamps. Once all the parameters are set, press on the main menu bar to apply current to the LSM. The icon highlights to indicate that the LSM is active. Configuration Settings Settings -> Configuration Settings Pressing on the menu bar results in the main Configuration Settings screen. Each selection is discussed below. You may exit the screen by pressing. 27-MNL-LDC-1 11

3: Operating Instructions Waveform Type Settings -> Configuration Settings -> Waveform Type There are 5 options for waveform type, selectable via the radio button. Once the desired option is selected, press to save and exit. System Parameters Settings -> Configuration Settings -> System Parameters This menu allows you to adjust various parameters on your device. Note that the icons for increasing or decreasing the values do not appear until one of the parameters is selected. The first two options allow you to modify the Display Timeout and Session Timeout values. Display timeout simply turns the display off after the allotted time runs out. Session timeout shuts down the unit after the allotted time runs out. Select the desired timeout to modify, then use or in the menu bar to increase or decrease the value. When the displayed value is 1 and is pressed one more time, ------- is displayed, which indicates an unlimited timeout. To save the values, press of the screen, press.. To cancel out 12 27-MNL-LDC-1

3: Operating Instructions On rare occasion, some LEDs may stay on even at the zero setting. In this case The LDC-1C may also be used to calibrate the dark offset of the LSM. This allows the user to adjust the current through the LED so that it is completely off. Select the radio button to activate the DARK OFFSET field; then use the triangle keys to increase or decrease the Dark Offset until the LED is completely off. When completed, press BNC Setup Settings -> Configuration Settings -> BNC Setup in the menu bar. This screen allows you to select Input Impedance and Voltage Range of the BNC. Press the radio button next to the desired value, then press in the menu bar to save. The function of the BNC differs depending on what type of waveform has been selected. When the Waveform Type is EXTERNAL SIGNAL, the BNC setup is treated as an input with the Voltage Range as indicated in this menu. The voltage applied to the BNC in this mode is ratiometric to the percentage of current applied to the attached LED. For example, if the range selected is 0 5.0V, a 2.5V signal applied at the BNC will drive the LED at 50% of its rated continuous current. When the Waveform Type is INTERNAL SQUARE WAVE, the BNC is used as a SQUAREWAVE output to an external device. The high going edge of the output is coincident with the start of the ON period of the LED and the signal returns low during the LED OFF period. Outputs for internal mode selections other than INTERNAL SQUARE WAVE are indeterminate. NOTE: When the LSM ON/OFF is in the OFF position, square waves may still be present on the BNC Connector. Languages Settings -> Configuration Settings -> Languages Text on the LDC-1C may be configured to English, French, Italian, German or Spanish by selecting the radio button next to the desired language. Once you have made your selection, press in the menu bar. 27-MNL-LDC-1 13

3: Operating Instructions Current Input Mode Settings -> Configuration Settings The icon in the bottom left corner allows the user to select if current is to be defined as a percentage of the maximum current, or if an absolute current value in milliamps is to be entered. Current Input Mode When the icon displays the percent sign, any input via either the arrow keys or the keypad will be a percentage of the maximum current for the connected LED. The percentage value can only be changed in increments of 1, not fractions. The corresponding current value will be displayed in the upper left corner of the main screen. Current value corresponding to percentage value User defined percentage value 14 27-MNL-LDC-1

3: Operating Instructions The default mode for the CURRENT INPUT icon is %. Most users will find the percentage values to be suitable for their needs. In special circumstances, added granularity in adjustment could be useful. This can be accomplished by selecting the absolute current value mode. When the icon is toggled to displays I, the user will be entering an absolute current value. The value entered may not exceed the maximum current allowed by the LSM. User defined current value Sound On/Off Settings -> Configuration Settings Sound On/Off Audible feedback when entering values on the touchscreen may be turned OFF or ON using the icon. 27-MNL-LDC-1 15

3: Operating Instructions Information Selecting on the main SETTINGS screen displays LSM information which the LDC-1C reads from the LSM when initially connected. Pressing in the menu bar cycles the display to LDC-1C information. Pressing in the menu bar cycles back to the LSM information. From either screen you may press in the menu bar to exit. 16 27-MNL-LDC-1

Warning Messages Chapter 4 Troubleshooting and Maintenance If the LSM is not connected to the LDC-1C at startup, or if it is disconnected while the LDC-1C is powered on, the following screen will be displayed. The only screen option the user has at this point is to scroll to view the LDC-1C information. Once a LSM is connected, the data will be read from the unit and the LDC-1C will display the main screen. If you have hooked up the LSM to the LDC-1C and see the disconnected message, check the connectors to make sure they are fully engaged. 27-MNL-LDC-1 17

4: Troubleshooting Touch Screen Verification If the user is touching the touchscreen while powering unit, the LDC-1C will display the Touch Screen Verification screen. Although it is not necessary to do this after unit production, you can use either your finger or stylus and touch points on the screen. Corresponding x-y coordinates will be displayed. Press to exit and move to the main screen. FAQs The display of my sine wave shows the pattern clipped at the bottom. Why? The LED current cycles on and off. When it turns off, the bottom of the sine wave becomes clipped. I set my current to a value, but a different number is displayed. Why? The value above the box is the set value. The value in the box is the measured value. My light source has a max pulse current of 1300mA, but I can only set it to 1000mA in external input mode. Why? When using an external signal source, the LDC-1C sets the maximum current to the maximum DC/continuous current. This prevents the light source from being over-driven, since the LDC-1C has no knowledge of the external waveform characteristics such as frequency and duty cycle. 18 27-MNL-LDC-1

4: Troubleshooting I have been using my LED light source for several hours, however in the information screen, it only reports several minutes of use. Why? The Session Time in the information screen reports the time of the most recent activation of the LED (equivalent to the time the ON/OFF icon on the main screen is highlighted.) My LED is not producing light. What happened? 1. Make sure you have activated the LED using the ON/OFF icon on the LDC-1C s touchscreen. 2. If using an external source to configure the LSM, make sure you have activated the source prior to pressing the ON/OFF icon on the menu bar. How can I operate the controller remotely? Remote control is not a feature of the LDC-1C. The USB interface is only used for software updates. LED Replacement All service, including LED replacements, must be performed by Ocean Optics, Inc. To initiate service, navigate to: https://oceanoptics.com/support/rma/ to obtain a RMA (Return Merchandise Authorization) number. It is very important that you obtain a RMA number. Please DO NOT SHIP merchandise to Ocean Optics, Inc. without prior authorization. 27-MNL-LDC-1 19

Index accessories, 2 battery, 18 bulb replacement, 19 certifications, vi components, 3 configuration settings, 11 bnc type, 13 current input mode, 14, 15 languages, 13 waveform type, 12 configuration system parameters, 12 configuring the LDC-1C, 9 connecting the LSM, 8 document audience, iv purpose, iv summary, iv FAQs, 18 A B C D F L LSM, LDC information, 16 N navigating the LDC-1C, 8 O operating environment, 6 package contents, 2 parts list, 7 product-related documentation, iv specifications table, 6 P S touch screen verification, 17 unpacking, 2 upgrades, iv T U W warning messages, 17 warranty, v 27-MNL-LDC-1 20