DELTA CONTROLS CORPORATION

Similar documents
DELTA CONTROLS CORPORATION

Oldham OLCT 200 Revision 1

Kurz Instruments, Inc. MFT B-Series

PrimaX IR. HART Specification

HART Field Device Specification PR 5437 Device Revision 2

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

HART Field Device Specification: CiDRA SONARtrac

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

Dissolved Oxygen (DO) Transmitter SMARTPro HART Command Specification

Siemens SITRANS LUT400 revision 1

Report Title : IR-Display HART Field Device Specification

HART 7.x Field Device Specification for STT700 SmartLine Temperature Transmitters Document Number: 34-TT Revision: 1.0 Release: June 2017

MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification

Model Ultima OPIR-5. Infrared Open Path Gas Detector HART Field Device Specification. Instruction Manual

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

HART Field Device Specification Fisher FIELDVUE DVC5000 Digital Valve Controllers

HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve

HART Field Device Specification Fisher FIELDVUE DVC6000 and DVC6200 HW1 Digital Valve Controllers

Mettler-Toledo Smart Communications Protocol Revison 1.0: June 9, 2004 Cond Ind 7100/2(X)H Command Specification Page: 1 of 16

HART 7.x Field Device Specification for Honeywell SLG 700 SmartLine Level Transmitter 34-SL Rev 6.0 December 2017

Transmitter Cond 7100 e /2 (X)H

Advanced Test Equipment Rentals ATEC (2832)

Communication Modules. Add-on modules HART. Operating Instructions 07/2010 SITRANS F

KROHNE H250 SN /01-03 MC H250/RR/M9/K2/ESK-Z C K F CIV MD C2H50H D 0.93 kg/l V 2.5 mpa.s T 23.5 C P 0.

MODEL 173 PROBE TYPE LEVEL TRANSMITTER With HART INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS DELTA CONTROLS CORPORATION

Transducers & Transmitters HART USERS MANUAL. GP:50 New York LTD Long Road Grand Island, NY USA

HART 7.x Field Device Specification for Honeywell ST 800 Smart Pressure Transmitters Document Number: 34-ST Revision: 1.

AW Flow Meters HART Summary for RT-Ex15

HART Actuator Field Unit Technical Manual Modular Design Electric Valve Actuators

The Omega product you have just received is of the highest quality available, offering superior performance, reliability and value to the user.

PC CONFIGURATOR Model: 27HUCFG. Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

For 2-wire Universal Temperature Transmitter B6U. PC CONFIGURATOR Model: B6UCFG. Users Manual

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

Technical Bulletin, HT/HM HART Module

RS485 S-Protocol Communications Supplemental Manual for Brooks GF40/GF80 Series Mass Flow Controllers and Meters

HART Protocol User Manual Rev. 1.0 December, 2014

Write Primary Variable Range Values Data written using command 35 will update the 4mA and 20mA settings in the menu.

HART Actuator Field Unit Technical Manual. (IQ / IQT 3 rd generation, CVA, CMA DEV_REV2) Publication PUB _0615

Model B3HU. PC CONFIGURATOR Model: B3HUCFG. Users Manual

Remote Operation Instructions HART Communicator 275 Asset Management Solutions (AMS) IFC090 KROHNE 11/2000

Advanced Test Equipment Rentals ATEC (2832)

MESCO HART Slave Stack 7.6 Datasheet for HART Slave Stack

HART Applications SEC-5000 Gas Detector

Contents General Data Data Exchange Mode Block Model

MICRO MOTION, INC. HART - Smart Communications Protocol 2000 SERIES ANALOG MVD TRANSMITTER-SPECIFIC COMMAND SPECIFICATION REVISION 6.

Profibus DP/V1 Interface for Bayard-Alpert / Pirani Gauge and High Pressure / Pirani Gauge

Calibrating HART Transmitters. HCF_LIT-054, Revision 1.1

Profibus DP/V1 Interface for Bayard-Alpert Pirani Capacitance Diaphragm Gauge

Electromagnetic Flowmeter ProcessMaster, HygienicMaster FEX300, FEX500

Device Management Protocols Protocoles de gestion des appareils Gerätezugangsprotokolle. The HART Protocol

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

Introduction. For more information. HART Protocol 7.0 Valid for software levels from 05.00

HART. Actuator Control. Redefining Flow Control

FLXA202/FLXA21 2-Wire Analyzer HART Communication. Functions Available via HART Communication...4. DD Menu Structure for ISC Meter Functions

FUJI HART EXPLORER INSTRUCTION MANUAL

Remote Operation Instructions HART Communicator 275 Asset Management Solutions (AMS) Process Device Manager (PDM) Device Type Manager(DTM) M10

USER INSTRUCTIONS. MX/QX HART Field Unit. Installation Operation Maintenance. Experience In Motion FCD LMENIM /16

HART UNIVERSAL TEMPERATURE TRANSMITTER

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

EX200-HART. Compact Electronic Actuator Positioner for use in EX2010A System. Features. Simple two-step calibration

HART UNIVERSAL TEMPERATURE TRANSMITTER

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

Autrol STT30 Ver 1.0. User s Guide MPC-E012B. Series. STT30 Ver 1.0. User Guide. Duon System Co.,Ltd

PACSystems* RX3i IC694ALG232

GE Fanuc IC695ALG708. Rx3i PacSystem

Model M3LLC STRAIN GAUGE TRANSMITTER. PC CONFIGURATOR SOFTWARE Model: M3LLCCFG. Users Manual M3LLCCFG USERS MANUAL EM-9197-T

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Electrical Measurement Module Kit with Docking Station

Technical Documentation 0630

PAC BI-DP BIM and 8701-CA-BI Carrier

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Providing the missing piece in your Condition Based Monitoring platform

HK-H375A HART. Hand Held Communicator. Manual

Report Title : IRmax Public Modbus Interface

Smart Wireless THUM Adapter

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

2G Actuator Communications Protocol Document Rotary & Linear Actuators

HART 710. User s Manual Version HART-710 User Manual (Version 1.00, July/2010) PAGE: 1

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

QUALITROL QTMS Transformer Monitoring System

Operating Instructions and Description of Instrument Function Prothermo NMT539

SOFTWARE FUNCTIONAL REQUIREMENTS SPECIFICATION. Athena DeviceNet Interface Module Revision /26/2001

PACSystems* RX3i IC694ALG233

Digital Thermometer and Thermostat

Low Voltage, 10-Bit Digital Temperature Sensor in 8-Lead MSOP AD7314

Rosemount Transmitter Diagnostics Reduce Maintenance Costs

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Model B6U / B6U-B PC CONFIGURATOR (model: B6UCON)

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

LCD Meter for Model 3051 Pressure Transmitters English Rev. AA

1.6 Configuring Intelligent Devices

16-Channel 16-Bit PMC Analog I/O Board

Solumetrix Toroidal Conductivity Sensors

DIGITAL TRANSDUCER TESTER & PC-INTERFACE (AVA-03) 16-APR-2015 PAGE 1 OF 9 1. GENERAL

Fox Thermal Instruments, Inc.

Intrinsically Safe Temperature Concentrator System

On Control SUSA v1.1 MODBUS Functions

XgardIQ. Intelligent Gas Detector and Transmitter. Modbus Field Device Specification

Transcription:

HART Field Device Specification: DELTA CONTROLS CORPORATION MODEL 173 REV 3.0 Document 00-17335, rev. A Initial release: 2 January 2019 Current release: 2 January 2019 Author: Ted Keys Delta Controls Corporation 585 Fortson Street Shreveport, LA 71107 USA HART is a registered trademark of the HART Communication Foundation

Revision A, Release Date: 2 JANUARY 2019 Page 34 of 53

TABLE OF CONTENTS 1. Introduction... 37 1.1 Scope... 37 1.2 Purpose... 37 1.3 Who should use this document?... 37 1.4 Abbreviations and definitions... 37 1.5 References... 37 2. Device Identification... 38 3. Product Overview... 38 4. Product Interfaces... 38 4.1 Process Interface... 38 4.1.1 Sensor Input Channels... 38 4.2 Host interface... 39 4.2.1 Analog Output: Process Temperature... 39 4.3 Local Interfaces, Jumpers and Switches... 39 4.3.1 Local Controls and Displays... 39 4.3.2 Internal Jumpers and Switches... 39 5. Variables... 40 5.1 Device Variables... 40 5.2 Dynamic Variables... 40 6. Status Information... 40 6.1 Device Status... 40 6.2 Extended Device Status... 42 6.3 Additional Device Status (Command #48)... 43 7. Universal Commands... 43 8. Common-Practice Commands... 44 8.1 Supported Commands... 44 8.2 Burst Mode... 44 8.3 Catch Device Variable... 45 9. Device-Specific Commands... 45 9.1 Command #128: READ PARAMETER... 45 Revision A, Release Date: 2 JANUARY 2019 Page 35 of 53

9.2 Command #129: WRITE PARAMETER... 46 9.3 Command #130: CALIBRATE TABLE VALUE... 46 9.4 Command #131: WRITE CALIBRATION TABLE ENTRY... 47 Request Data Bytes... 47 10. Tables... 48 10.1 List of Device Parameters (see command 128 & 129)... 48 11. Performance... 49 11.1 Sampling Rates... 49 11.2 Power-Up... 49 11.3 Reset... 49 11.4 Self-Test... 49 11.5 Command Response Times... 50 11.6 Busy and Delayed-Response... 51 11.7 Long Messages... 51 11.8 Non-Volatile Memory... 51 11.9 Modes... 51 11.10 Write Protection... 51 11.11 Damping... 51 Annex A. Capability Checklist... 52 Annex B. Default Configuration... 53 Annex C. Revision History... 54 Revision A, Release Date: 2 JANUARY 2019 Page 36 of 53

1. INTRODUCTION 1.1 Scope The Delta Controls Corporation Level Transmitter, model 173, revision 3 complies with HART Protocol Revision 7.06. This document specifies all the device specific features and documents HART Protocol implementation details (e.g., the Engineering Unit Codes supported). The functionality of this Field Device is described sufficiently to allow its proper application in a process and its complete support in HART capable Host Applications. 1.2 Purpose This specification is designed to complement other documentation (e.g., the 173 Installation Manual) by providing a complete, unambiguous description of this Field Device from a HART Communication perspective 1.3 Who should use this document? The specification is designed to be a technical reference for HART capable Host Application Developers, System Integrators and knowledgeable End Users. It also provides functional specifications (e.g., commands, enumerations and performance requirements) used during Field Device development, maintenance and testing. This document assumes the reader is familiar with HART Protocol requirements and terminology. 1.4 Abbreviations and definitions ADC Analog to Digital Converter CPU DAC EEPROM Central Processing Unit (of microprocessor) Digital to Analog Converter Electrically-Erasable Read-Only Memory 1.5 References HART Smart Communications Protocol Specification. HCF_SPEC-12. Available from the HCF. 173 Installation Manual, Document 00-17303. Available from the Delta Controls Corporation. Revision A, Release Date: 2 JANUARY 2019 Page 37 of 53

2. DEVICE IDENTIFICATION Manufacturer Name: Delta Controls Corporation Model Name(s): 173 Manufacture ID Code: 24842 (0x610A) Device Type Code: 58439 (0xE447) HART Protocol Revision 7.06 Device Revision: 3 Number of Device Variables 1 Physical Layers Supported Physical Device Category FSK Transmitter, Non-DC-isolated Bus Device The 173 consists of an explosion-proof housing mounted on an extractable-under-pressure capacitance probe. The name plate is located on the housing cover and indicates the model name and revision. 3. PRODUCT OVERVIEW The 173 is a simple two-wire loop-powered level transmitter with a 4-to-20mA output. Measurement is via probe capacitance The 173 rev. 3 replaces the earlier rev. 2 model, providing improved HART communication capability. The device measures probe capacitance over the maximum range of 0-2000pF and converts this to a level measurement. 4. PRODUCT INTERFACES 4.1 Process Interface 4.1.1 Sensor Input Channels The device has two input channels labeled Probe and Comp. The Probe input measures the sum of the probe capacitance and any interconnecting cable between the probe and the electronics (if any). The Comp input is typically connected to an identical interconnecting cable. The device subtracts the capacitance measured on the Comp terminal from the capacitance measured on the Probe terminal, thus eliminating the interconnecting cable capacitance from the probe measurement. This is done to eliminate accuracy problems that could occur due to cable capacitance changes with temperature. When the electronics are mounted directly to the probe the short interconnecting wire that connects between the electronics and the probe has an insignificant capacitance, and thus the Comp terminal is left unused. Revision A, Release Date: 2 JANUARY 2019 Page 38 of 53

4.2 Host interface 4.2.1 Analog Output: Process Temperature The two-wire 4-to-20mA current loop is connected on two terminals marked "Loop+" and "Loop-". Refer to the Installation Manual for connection details. This is the only output from this transmitter, representing the level measurement, linearized and scaled according to the configured range of the instrument. This output corresponds to the Primary Variable. HART Communication is supported on this loop. This device has a CN number of 1. A guaranteed linear over-range is provided. Device malfunction can be indicated by downscale or up-scale current. The direction is selectable by the user; see Section 4.3 below. Current values are shown in the table below. Direction Values (percent of range) Linear over-range Down -1.25% 3.8 ma Device malfunction indication Up +105.0% 1.0% 20.5 ma Down: less than -2.5% 3.6 ma Up: greater than +106.25% 21.0 ma Maximum current +112.5% 22.0 ma Multi-Drop current draw Lift-off voltage Values (ma or V) 4.0 ma 12 V 4.3 Local Interfaces, Jumpers and Switches 4.3.1 Local Controls and Displays The field device has a window providing visible access to an LCD display. 4.3.2 Internal Jumpers and Switches Four pushbuttons are provided to set up operating parameters without connection to an external controller. Detailed information is provided in the 173 Operation Manual. Device Variables Revision A, Release Date: 2 JANUARY 2019 Page 39 of 53

5. VARIABLES 5.1 Device Variables Variable Meaning Units Unit Codes DV0 PV ft,m,in,cm,mm,%,undefined 44,45,47,48,49,57,240 5.2 Dynamic Variables One Dynamic Variable is implemented. Meaning Units PV Process Variable ft,m,in,cm,mm,%,undefined 6. STATUS INFORMATION 6.1 Device Status BIT Name Meaning 0 0 Primary Variable out of limits 1 Non PV out of limits 2 Loop Current Saturated 3 Loop Current Fixed 4 More Status Available Set if the Device Variable mapped to PV is out of transducer limits. Range setting by Command 35 does not affect these limits. Set if any of the Device Variables not mapped to PV is out of limits. This bit is formed by OR-ing all out-of-limit informations of DV 0 to 5 except the one mapped to PV. Set if the analog output 1 (channel 0) current is out of the linear overrange Limits. Set if analog output 1 (channel 0) current no longer tracks the PV value. Use of any of commands 6, 40, 66 or 79 may cause the current to be fixed. Set whenever any irregularity is detected. Use of Command 48 will read additional details. 5 Cold Start Set after initial power up and after execution of Command 42. Bit is cleared for each Master individually after recognition of the first command. Revision A, Release Date: 2 JANUARY 2019 Page 40 of 53

6 Configuration Changed 7 Device Malfunction Set when the Field Device configuration is modified. Each Master will clear this bit individually by use of Command 38. Set if the Field Device's self-monitoring detected an abnormal condition of class Error. Warnings will not set this bit. Revision A, Release Date: 2 JANUARY 2019 Page 41 of 53

6.2 Extended Device Status Bit Name Meaning 0 Maintenance Required 1 Device Variable Alert Device requires maintenance. Some device variable is in an alarm or warning state 2 unused Bit not supported 3 Failure Device variable invalid due to malfunction 4 Out of Spec Condition detected that could affect accuracy (ie ambient temperature) 5 Function Check Bit not supported 6 Unused Undefined 7 Unused Undefined Revision A, Release Date: 2 JANUARY 2019 Page 42 of 53

6.3 Additional Device Status (Command #48) Command #48 returns 9 bytes of data, with the following status information: Byte Bit Meaning Class Device Status Bits Set 0 DEVICE SPECIFIC STATUS 0 Probe Out of Limits WARNING 4 1 Comp Out of Limits WARNING 4 2 Internal Reference 1 Out of Limits ERROR 4,7 3 Internal Reference 2 Out of Limits ERROR 4,7 4 Temperature Out of Limits WARNING 4 5 Not Defined 6 Loop Fault Detected WARNING 4 7 Not Defined 1,2,3, 4,5 Not Defined 6 EXENDED DEVICE STATUS 0 Device requires maintenance. This is usually set when the optical window needs to be cleaned. WARNING 4 1 Some device variable is in an alarm or warning state WARNING 4 2 Bit not supported 3 Bit not supported ERROR 4,7 4 Bit not supported WARNING 4 5 Bit not supported 6,7 Not Defined 7 Not supported 8 STANDARD STATUS 0,1,2 Bit(s) not supported 3 Watchdog reset occurred WARNING 4 4,5,6,7 Bit(s) not supported "Not Defined" bits are always set to 0. 7. UNIVERSAL COMMANDS Command #3 returns PV for a total of 9 bytes of response data). Revision A, Release Date: 2 JANUARY 2019 Page 43 of 53

Sensor serial number is Not Defined, and returns 0. 8. COMMON-PRACTICE COMMANDS 8.1 Supported Commands The following common-practice commands are implemented: 33 Read Device Variables 34 Write Damping Value 35 Write Range Values 40 Enter/Exit Fixed Current Mode 42 Perform Master Reset 44 Write PV Units 45 Trim DAC Zero 46 Trim DAC Gain 48 Read Additional Device Status 54 Read Device Variable Information 59 Write Number of Response Preambles 72 Squawk (Causes Outline Rectangle on LCD for 2 seconds) 100 Write Primary Variable Alarm Code 103 Write Burst Period 104 Write Burst Trigger 105 Read Burst Mode Configuration 107 Write Burst Device Variables 108 Write Burst Mode Command Number 109 Burst Mode Control 8.2 Burst Mode This Field Device supports three Burst Messages. Revision A, Release Date: 2 JANUARY 2019 Page 44 of 53

The following commands can be represented in a Burst Message: 1 Read Primary Variable 2 Read Loop Current and Percent Of Range 3 Read Dynamic Variables and Loop Current 9 Read Device Variables with Status 33 Read Device Variables 48 Read Additional Device Status 8.3 Catch Device Variable This Field Device does not support Catch Device Variable. 9. DEVICE-SPECIFIC COMMANDS The following device-specific commands are implemented: 128 Read Parameter 129 Write Parameter 130 Write Calibration Value 131 Write Calibration Table Entry 9.1 Command #128: READ PARAMETER Read a device parameter value Request Data Bytes Byte Format Description 0 Enum Parameter to read (see section 10.1) Response Data Bytes Byte Format Description 0 Enum Parameter to read 1 Enum Datatype (See bytes 3-6) 2 Enum Units 3 Byte Value Datatype = 0 3-4 Int[2] Value Datatype = 2 3-6 Float Value Datatype = 3 Command-Specific Response Codes Revision A, Release Date: 2 JANUARY 2019 Page 45 of 53

Code Class Description 0 Success No Command-Specific Errors 2 Error Invalid selection (of units) 5 Error Too few data bytes 9.2 Command #129: WRITE PARAMETER Request Data Bytes Byte Format Description 0 Enum Parameter to write (see section 10.1) 1 1,2 1,2,3,4 Byte Int Float Byte value to write Integer value to write Float value to write Response Data Bytes Byte Format Description 0 Enum Parameter (see section 10.1) 1 Enum Datatype (See bytes 3-6) 2 Enum Units 3 3-4 3-6 Byte Int[2] Float Value Datatype = 0 Datatype = 2 Datatype = 3 Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 2 Error Invalid selection (of units) 5 Error Too few data bytes 9.3 Command #130: CALIBRATE TABLE VALUE Calibrate by setting the process level to a known value. Write that value to a calibration point using command 130. Set the process level to a different known value (as far away from the first level as possible). Write that value to a different calibration point using command 130. Calibration point to write must be less than or equal to the number of active calibration points. Note: After writing, the device sorts the calibration table in order of level, so you should Revision A, Release Date: 2 JANUARY 2019 Page 46 of 53

read all calibration points before calibrating the next point, in case the values were moved to another calibration point. Request Data Bytes Byte Format Description 0 Byte Calibration Point to write 1-4 Float PV to associate with current process level Response Data Bytes Byte Format Description 0 Byte Calibration point to write 1-4 Float PV to associate with current process level 5-8 Float Net capacitance at current process level Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 2 Error Invalid selection (of units) 5 Error Too few data bytes 9.4 Command #131: WRITE CALIBRATION TABLE ENTRY Use this command to update the calibration table offline. Request Data Bytes Byte Format Description 0 Byte Calibration Point to write 1-4 Float PV to associate with the Calibration Point 5-8 Float Net Capacitance to associate with the Calibration Point Response Data Bytes Byte Format Description 0 Byte Calibration point to write 1-4 Float PV to associate with the Calibration Point 5-8 Float Net Capacitance to associate with the Calibration Point Command-Specific Response Codes Code Class Description 0 Success No Command-Specific Errors 2 Error Invalid selection (of units) 5 Error Too few data bytes Revision A, Release Date: 2 JANUARY 2019 Page 47 of 53

10. TABLES 10.1 List of Device Parameters (see command 128 & 129) Parameter Description (See doc 00-17303 for more information) Format 0 PV Float 1 Loop ma Float 2 Loop % Float 3 Units Enum 4 Lower Range Value Float 5 Upper Range Value Float 6 Number of Active Calibration Points Byte 7 Calibration point #1 PV Float 8 Calibration point #2 PV Float 9 Calibration point #3 PV (inactive cal pts return NaN) Float 10 Calibration point #4 PV Float 11 Calibration point #5 PV Float 12 Calibration point #6 PV Float 13 Calibration point #7 PV Float 14 Calibration point #8 PV Float 15 Calibration point #9 PV Float 16 Calibration point #10 PV Float 18 Calibration point #1 pf Float 19 Calibration point #2 pf Float 20 Calibration point #3 pf Float 21 Calibration point #4 pf Float 22 Calibration point #5 pf Float 23 Calibration point #6 pf Float 24 Calibration point #7 pf Float 25 Calibration point #8 pf Float 26 Calibration point #9 pf Float 27 Calibration point #10 pf Float 28 Range 0=2000pF; 1=600pF; 2=200pF Enum 29 Damping Value (seconds) Float 30 4mA trim value Int 31 20mA trim value Int 32 Alarm Action 0=drive high;1=drive low;2=hold;3=ignore Enum 33 Polling Address Byte Revision A, Release Date: 2 JANUARY 2019 Page 48 of 53

Parameter Description (See doc 00-17303 for more information) Format 34 Loop Control 0=normal;1=multidrop;2=manual Enum 35 Probe raw value Int 36 Comp raw value Int 37 Internal Reference 1 raw value Int 38 Internal Reference 2 raw value Int 39 Probe Capacitance (pf) Float 40 Comp Capacitance (pf) Float 41 Net Capacitance (pf) Float 42 Offset Cal Float 43 Module Temperature ( C) Float 11. PERFORMANCE 11.1 Sampling Rates Typical sampling rates are shown in the following table. Probe sample rate Comp sample rate Analog output update 3 per second 1 per second 3 per second 11.2 Power-Up On power up, the transmitter goes through an initialization procedure, which takes approximately 2 seconds. During this period, the device will not respond to HART commands, and the analog output is set at 4.0mA. Fixed-current mode is cancelled by power loss. 11.3 Reset Command 42 ("Device Reset") causes the device to reset its microprocessor. The resulting restart is identical to the normal power up sequence. 11.4 Self-Test Continuous self-testing is part of the normal device operation. Revision A, Release Date: 2 JANUARY 2019 Page 49 of 53

11.5 Command Response Times Minimum 20ms Typical 50ms Maximum 100ms * Revision A, Release Date: 2 JANUARY 2019 Page 50 of 53

11.6 Busy and Delayed-Response The transmitter does not respond with Delayed Response. Changing units (command 44) may cause subsequent commands to respond with BUSY for a few seconds. 11.7 Long Messages The largest data field used is in the response to Command 9: 66 bytes including the two status bytes. 11.8 Non-Volatile Memory EEPROM is used to hold the device s configuration parameters. New data is written to this memory immediately on execution of a write command. 11.9 Modes Fixed current mode is implemented, using Command 40. This mode is cleared by power loss or reset. Another method to affect the loop current is Command 6 with Loop Current Mode parameter set to disabled. This mode setting is not affected by power cycle or reset but has to be changed by execution of Command 6 with Loop Current Mode parameter set to enabled. 11.10 Write Protection This Field Device does not support write-protection. A hardware switch or jumper cannot be accessed during operation in explosion hazard areas. 11.11 Damping The damping function has a first order low pass characteristic affecting only the PV and the loop current signal. The device accepts values from 0 to 60 seconds. Revision A, Release Date: 2 JANUARY 2019 Page 51 of 53

ANNEX A. CAPABILITY CHECKLIST Manufacturer, model and revision Delta Controls Corporation model 173 Rev 3 Device type Transmitter HART revision 7.06 Device Description available Yes Number and type of sensors 2 capacitance sensors Number and type of actuators 0 Number and type of host side signals 1: 4-20mA analog Number of Device Variables 1 Number of Dynamic Variables 1 Mappable Dynamic Variables? No Number of common-practice commands 20 Number of device-specific commands 4 Bits of additional device status 8 Alternative operating modes? No Burst mode? Yes Write-protection? No Revision A, Release Date: 2 JANUARY 2019 Page 52 of 53

ANNEX B. DEFAULT CONFIGURATION Parameter Lower Range Value 0 Upper Range Value 100 PV Units % Damping time constant 4 second Polling Address 0 Number of response preambles 5 Default value Revision A, Release Date: 2 JANUARY 2019 Page 53 of 53

ANNEX C. REVISION HISTORY A1. Changes from Rev 2.0 to Rev 3.0 Support was added for HART 7. Revision A, Release Date: 2 JANUARY 2019 Page 54 of 53