INNOVATION IN MAGNETICS DS0070/12. Mag-01H D/I. Declinometer/Inclinometer System.

Similar documents
Mag-01H. Fluxgate Declinometer/Inclinometer. Mag-01H D/I. World leaders in high precision magnetic field measurements

INNOVATION IN MAGNETICS DS0013/27. Mag-03. Three-Axis Magnetic Field Sensors.

Data Acquisition & Signal Conditioning Units

Innovation in Magnetic Field Measuring Instruments. Mag648 & Mag649. Low Power Three-Axis Magnetic Field Sensors.

Spacemag & Spacemag-Lite

INNOVATION IN MAGNETICS DS-2201/8 DAS1. Data Acquisition System.

Mag High Temperature Three-Axis Magnetic Field Probes

Mag-03. Three-Axis Magnetic Field Sensors.

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments

Innovation in Magnetic Field Measuring Instruments. Grad601. Magnetic Gradiometer System

Mag-03. Three-axis Magnetic Field Sensors. For innovation in magnetic measuring instruments

Innovation in Magnetic Field Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors.

Operation Manual for Mag612 Three-Axis Magnetic Field Probe

Innovation in Magnetic Measuring Instruments. Data Acquisition & Conditioning Units

HCS1 Three-Axis Helmholtz Coil System

Innovation in Magnetic Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors

Operation Manual for. Mag-01 & Mag-01H Single Axis Fluxgate Magnetometers with Mag Probes B-G

Product Identification Product name Package Noise* Range in µt Mag-03 MC= Cylindrical B = Basic ±70 MCES = Cylindrical, environmentally sealed to IP64

Operation Manual for. Mag628/629 and Mag669 Three-Axis Aerospace Magnetometers.

Operation Manual for. Geolabsoft for Windows (PC version)

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

NI 6521 Specifications

INSTALLATION INSTRUCTIONS LFH160 Cable

High-Performance Differential Probes P7350 P7330 P6330 Datasheet

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

FP-PS-4. Features. Installation

CLASS 1 DIVISION 2 PRODUCTS

Machine Vision Lyte-MV

Handheld Gaussmeter Gaussmeter

Shortform Catalogue Global Suppliers of Measurement and Protection Equipment for Industry >> moving iron >> rectified moving coil

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

The Thermal Imager for the Highest Demands

Mini position indicator

SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE

premier & acculase modulatable/machine vision lyte mv/dragonfly/ standard cw operation imatronic/laserlyte/laserlyte-flex/guideline/

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

DEFECTOMETER High detection sensitivity to surface flaws (even underneath paint) Simple, microprocessor-controlled operation

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

E D I T I O N PRODUCT LIST SURVEY PRODUCTS LTD

Keysight Technologies N4000A, N4001A, N4002A SNS Series Noise Sources

4 GHz Active Probe P7240 Datasheet

N420 R420 R423. series

TriMode Probe Family P7700 Series TriMode Probes

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

9200, Seismoprobe* Velocity Transducers

POWER. Catalogue The Crest Company All rights reserved.

Datasheet Thermal imager

Supply Voltage V dc Supply is fully isolated internally, and protected against transients. Internal power modules are CE certified.

GE Industrial Sensing. Druck DPI 104. Digital pressure indicator User manual - K394

Rugged and waterproof, plus high-power telescope with superior Nikon optics

FP-AO-200 AND CFP-AO-200

NI 653x Cable Adapter

Installation Manual for D244X Series 24-volt Power Supplies

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

Datasheet Thermal imager

Gas detection just got personal

Agilent U2941A Parametric Test Fixture

Model 1327 Chart Recorder Instruction Manual

Laserlyte Alignment System

TEL: / FAX:

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

4 GHz Active Probe P7240 Datasheet

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

DEWE-43 UNIVERSAL USB INSTRUMENT. 8 analog multi-sensor inputs 8 counter inputs 2 CAN-bus interfaces CPAD2 expansion for low speed ed temperature

All models shown smaller than actual size (probes sold separately except on RH model). UWBT-RH Relative humidity (includes probe).

ACS HEAVY DUTY INCLINOMETER SAE J1939 INTERFACE

XL-80 spares list. Application note. Overview

Unaffected by Angle, Colour, or Dirt

from P.R.Engineering Ltd Tel:

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

Programmable DC power supplies

Cable distribution systems

Fast 3D EMC/EMI Scan with Detectus Scanning System and Tektronix Real Time Spectrum Analyzers CASE STUDY

DS BAS 08/99 UNC 532

Differential Probes TDP1500 TDP3500 Data Sheet

Optimum sensing capability for LCD manufacturing

You need the following to set up and use your terminal block:

Cable distribution systems

Multi-Function Ground Resistance Tester Model 6471

Electronic pressure switch with display For sanitary applications Model PSA-31

Agilent Noise Source Calibration Using the Agilent N8975A Noise Figure Analyzer and the N2002A Noise Source Test Set. Product Note

360W and 720W Programmable DC Power Supplies

INNOVATUM REFERENCE MANUALS. Section 4-1. Smartrak Description & Installation

Video inspection systems

Electronic SD1, AS 8, ASR 14, ASR 20

N2870A Series Passive Probes and Accessories

NEXPTZ364P(N)A HIGH-SPEED EXPLOSION-PROOF PTZ FEATURES.

ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Pressure switches and thermostats, types KP and KPI

Calibrating FieldPoint Analog Input Modules with Calibration Executive

Circuit Breaker Analyzer System

MEASURING AND TESTING INSTRUMENTS

N2870A Series Passive Probes and Accessories

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Infrared temperature measuring instrument

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Transcription:

INNOVATION IN MAGNETICS DS0070/12 Mag-01H D/I Declinometer/Inclinometer System www.bartington.com

Mag-01H D/I Declinometer/Inclinometer System Mag-01H D/I Fluxgate Declinometer/Inclinometer System The Mag-01H Declinometer/Inclinometer system provides fast, accurate and convenient measurements of the declination and inclination of the geomagnetic field. Reliability and ease of use make this system the ideal choice for magnetic observations and surveying, in both fixed and mobile locations. If required, it can be calibrated against a reference system at a magnetic observatory. The system comprises a single axis Mag-01H magnetometer, a Mag A fluxgate probe, and a WILD T1 6 seconds steel-free theodolite. A steel-free tripod is available if required. Bartington is a registered trademark of Bartington Instruments Limited in the following countries: Australia, Brazil, Canada, China, European Union, India, Israel, Japan, Mexico, New Zealand, Norway, Russia, Singapore, South Korea, Switzerland, Turkey, United Kingdom, United States of America, and Vietnam.

www.bartington.com Features Measures localised magnetic field declination and inclination to 6 seconds of arc Non-magnetic theodolite 20 hours continuous use on internal battery Typical Applications Earth s magnetic field Measurement Calibration tool for compasses and rangefinders In field referencing in oil and gas exploration Magnetic cleanliness of sites such as aircraft compass calibration pads

Mag-01H D/I Declinometer/Inclinometer System Mag-01H Single Axis Fluxgate Magnetometer This battery powered instrument provides the drive for the probe and processes its output to show the field strength on a 4½-digit display, updated at 2 readings per second. An analogue output is also provided. The Mag-01H may be fitted with an audio output indicator, on request. This facility enables the operator to seek the null position without continuously monitoring the digital display. A sensitivity switch can be used to select 1nT or 0.1nT resolution. The non-magnetic internal battery provides 20 hours of continuous use and can be recharged via the mains adaptor or vehicle connector. Battery voltage is displayed for several seconds after switch-on and an audible alarm indicates when recharging is required. The magnetometer and cable incorporate shielding against radio frequency interference. Specification Mag-01H instrument Number of axes Polarity Measuring range Bandwidth Scaling (analogue output) One +ve non-inverting output when pointing North ±0.2mT DC to 10Hz (-3dB) at 20μT p-p. Roll off -12dB per octave (DC on x10 sensitivity) 10mV/μT (100mV/μT with x10 sensitivity) Scaling temperature coefficient Offset in zero field Offset temperature coefficient <10ppm/ C ±1nT 0.01nT/ C Scaling error 0.1% Maximum resolution Operating temperature range Relative humidity Dimensions (W x H x D) Weight Enclosure material Liquid crystal display: x1 sensitivity x10 sensitivity Front panel: On/off switch Probe input Charge indicator Sensitivity control Rear panel: Battery charger inlet Analogue output x1 sensitivity x10 sensitivity Output impedance Battery 0.1nT 0 C to +50 C 0-90% non-condensing 155 x 68 x 175mm 0.950kg High impact ABS 4 1/2 digit autoranging Displays 0 to 20μT with 1nT resolution and 20 to 200μT with 10nT resolution Displays 0 to 2μT with 0.1nT resolution and 2 to 20μT with 1nT resolution Switches on internal battery 6 pole waterproof Fischer connector Illuminated when external supply connected Increases the sensitivity by a factor of 10 2.1mm socket 6-18V DC 0.5A max., polarity protected, continuous or intermittent use 4mm insulated sockets 100μT/V, ±500μT max, 1nT resolution 10μT/V, ±50μT max, 0.1nT resolution 1kΩ 6V lead acid

www.bartington.com Mag A Probe The Mag A probe contains a fluxgate element selected for high rejection of orthogonal fields. The element is extremely high quality, very stable and well aligned with little offset. The probe alignment will normally be stable to 1 minute of arc over the suggested two-year calibration period. Re-adjustment is seldom required. A mechanically isolated enclosure protects the sensor from accidental misalignment. The probe has a strong but highly flexible 5-metre cable for connection to the Mag-01H instrument. Each probe is individually calibrated to a standard traceable to the UK National Physical Laboratory. Probes and electronics units are fully interchangeable, with a cumulative calibration uncertainty of 0.25%. Specification - Mag A Probe Calibration accuracy 0.1% Collimation error Fluxgate element Operating temperature range Dimensions (H x W x D): with WILD T1 theodolite with Zeiss theodolite Weight Protective enclosure Connecting cable: length core-screen capacitance resistance <20 seconds (collimation adjustment by joystick and clamp) Temperature coefficient <10ppm/ C, length 55mm, with precision feedback solenoid -20 C to +80 C 32.5 x 106* x 50mm 25 x 100* x 50mm * Add on 10mm for cable gland 250g Aluminium housing, mechanically isolated from element mounting 4-core overall screened high flexibility audio grade with 6 pole Fischer connector 5m standard (alternative lengths available) 160pF/m 92Ω/km

Mag-01H D/I Declinometer/Inclinometer System WILD T1 Steel-free Theodolite As these optical theodolites are no longer manufactured, each unit supplied is pre-used, restored as far as possible to its original condition and meticulously converted to be steel-free. All magnetic components are replaced by a nonmagnetic equivalent. The horizontal and vertical axis bearings are replaced with specially plated phosphor bronze parts, and the steel ball-race removed from the horizontal axis. The WILD axis lubrication system ensures that these parts require zero maintenance. The redundant resetting mechanism for the horizontal circle has been eliminated to give enhanced accuracy. The steep sighting prisms allow fields down to 18 to be measured. The optical/magnetic collimation error is set to less than 20 seconds. All theodolites undergo a rigorous check for magnetic hygiene and are guaranteed to be non-magnetic. Theodolite (steel-free) WILD T1 (360 o ) Scaling division Estimation Directional accuracy* 6 seconds 3 seconds 3 seconds * The directional accuracy is given as the standard deviation to DIN 18723 of a direction measured in two telescope positions. Weight with fluxgate sensor fitted Weight in carrying case 5.85kg 8.75kg A separate manual for the WILD T1 theodolite is available on request.

www.bartington.com Accessories and Optional Extras The Mag-01H and the Wild T1 theodolite are each provided in a robust polycarbonate carrying case. Accessories AC mains adaptor for 110/220/240V with outlet adaptors Vehicle charging connector 12V DC output (12-24V input) Operation Manual for Mag-01H Declinometer/Inclinometer and Wild T1 theodolite Screwdriver Orange filter and sun filter Lens cap Mag-01H carry bag Polycarbonate carrying case for Mag-01H and accessories Optional extras Steel-free tripod (5/8-11 UNC) Tripod weight: 6.1kg (8kg packaged) Steep sighting prisms Audio output Calibration check at Hartland Point Observatory Chemiluminescent light sources (for night use) Pillar mounting adaptor (5/8-11 UNC) with pins on a 120mm PCD

Bartington Instruments Ltd 5, 8, 10, 11 & 12 Thorney Leys Business Park Witney, Oxford, OX28 4GE. England Telephone: +44 (0)1993 706565 Email: sales@bartington.com Website: www.bartington.com The specifications of the products described in this brochure are subject to change without prior notice.