NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

Similar documents
NI SD Card Memory Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

NI 6521 Specifications

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, Sinking Digital Input/Sourcing Digital Output Module. ni.

You need the following to set up and use your terminal block:

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

Electrical. SPECIFICATIONS SH Cable

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

INSTALLATION INSTRUCTIONS LFH160 Cable

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

FP-AIO-600 and cfp-aio-600

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

CompactRIO Reconfigurable Embedded Chassis

SH Cable Specifications

Getting Started with the NI 8234

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

NI SMB-2145/2146/2147/2148

SCC-AO10 Isolated Analog Output Module

FP-AO-210 AND CFP-AO-210

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Stepper Drive. ni.com/manuals

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

FP-AO-200 AND CFP-AO-200

FP-PS-4. Features. Installation

NI USB-9201/9221. Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 12-Bit Analog Input Devices

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

NI crio-9101/9102/9103/9104

SCC-RLY01 Relay Module

Getting Started with the NI PCI-1405

NI 9503 Stepper Drive

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sourcing Digital Output Device

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

Getting Started with the NI PCIe-8253

Getting Started with the NI 8234

SCXI -1313A Terminal Block

Getting Started with the NI PCI-8254R

Getting Started with the NI PCIe-1433

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

Getting Started with the NI PCIe-8235

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

TBX-96 TERMINAL BLOCK

Getting Started with the NI PCIe-8255R

NI 653x Cable Adapter

QUICK START GUIDE. What You Need to Get Set Up

Getting Started with the NI PXI/PCIe-8231

CompactRIO NI crio-9012/9014

NI 9472 DATASHEET. 8 DO, 6 V to 30 V, Sourcing, 100 μs

NI PXI-2567 Specifications

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

USER GUIDE Universal Motion Interface (UMI)-7764

Compact FieldPoint cfp-cal

Calibrating FieldPoint Analog Input Modules with Calibration Executive

Getting Started with NI-Motion for NI 73xx Motion Controllers

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

NI PCIe-8255R Quick Start Guide

NI 9266 Datasheet DATASHEET. 8 AO, 0 ma to 20 ma, 16 Bit Simultaneous

Getting Started with the NI PXI/PCI-1422

NI 9375 DATASHEET. 16 DI/16 DO, 30 VDC, 7 μs Sinking DI, 500 μs Sourcing DO

NI 9213 Calibration Procedure

NI PXI-1042 Series Power Supply Shuttle

NI 9201 DATASHEET. 8 AI, ±10 V, 12 Bit, 500 ks/s Aggregate

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

GETTING STARTED GUIDE NI Port, RS232 Serial Module. Français Deutsch 日本語한국어简体中文. ni.com/manuals

NI 9269 DATASHEET. 4 AO, ±10 V, ±40 V Stacked, 16 Bit, 100 ks/s/ch Simultaneous

VME-GPIB Installation and User Guide

NI 6584R User Guide and Specifications

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

GETTING STARTED GUIDE NI Port, RS485/RS422 Serial Module. Français Deutsch 日本語한국어简体中文. ni.com/manuals

36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module. DSUB are referred to inclusively as the NI 9476.

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

Getting Started with the NI PXI/PCI-1409

TBX-1316 High-Voltage Attenuator Terminal Block

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

FP-2000/2010 FieldPoint Quick Start Guide

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

NI Serial Hardware Specifications Guide

NI 9220 DATASHEET. 16 AI, ±10 V, 16 Bit, 100 ks/s/ch Simultaneous

Getting Started with R Series Multifunction RIO

Getting Started with R Series Intelligent DAQ

8 AI (12-Bit, 10 ks/s), 2 AO (150 Hz), 12 DIO USB Multifunction I/O Device

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

CompactRIO crio-9072/3/4

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

FieldPoint cfp-21xx. Quick Start Guide. What You Need to Get Set Up

USB Definitions. Conditions. Analog Input SPECIFICATIONS. 8 AI (10 ks/s), 4 DIO USB Multifunction I/O Device

NI 9223 Datasheet DATASHEET. 4 AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

Getting Results with the NI PXI-6585R

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

Transcription:

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9265 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module Français Deutsch ni.com/manuals

This document describes how to use the National Instruments 9265 and includes specifications and terminal assignments for the NI 9265. Visit ni.com/info and enter rdsoftwareversion to determine which software you need for the modules you are using. For information about installing, configuring, and programming the system, refer to the system documentation. Visit ni.com/info and enter cseriesdoc for information about C Series documentation. Note The safety guidelines and specifications in this document are specific to the NI 9265. The other components in the system might not meet the same safety ratings and specifications. Refer to the documentation for each component in the system to determine the safety ratings and specifications for the entire system. Visit ni.com/info and enter cseriesdoc for information about C Series documentation. Safety Guidelines Operate the NI 9265 only as described in these operating instructions. NI 9265 Operating Instructions and Specifications 2 ni.com

Hot Surface This icon denotes that the component may be hot. Touching this component may result in bodily injury. Safety Guidelines for Hazardous Voltages If hazardous voltages are connected to the module, take the following precautions. A hazardous voltage is a voltage greater than 42.4 V pk or 60 VDC to earth ground. Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards. Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same module. Caution Make sure that devices and circuits connected to the module are properly insulated from human contact. Caution When module terminals are hazardous voltage LIVE (>42.4 V pk /60 VDC), you must ensure that devices and circuits connected to the module are properly insulated from human contact. You must use the NI 9932 connector backshell kit to ensure that the terminals are not accessible. National Instruments Corp. 3 NI 9265 Operating Instructions and Specifications

Figure 1 shows the NI 9932 connector backshell. Figure 1. NI 9932 Connector Backshell Safety Guidelines for Hazardous Locations The NI 9265 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nc IIC T4, and Ex nc IIC T4 hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9265 in a potentially explosive environment. Not following these guidelines may result in serious injury or death. NI 9265 Operating Instructions and Specifications 4 ni.com

Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous. Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous. Caution Substitution of components may impair suitability for Class I, Division 2. Caution For Zone 2 applications, install the system in an enclosure rated to at least IP 54 as defined by IEC 60529 and EN 60529. Caution For Zone 2 applications, connected signals must be within the following limits: Capacitance...80 nf max Inductance...0.2 H max National Instruments Corp. 5 NI 9265 Operating Instructions and Specifications

Special Conditions for Hazardous Locations Use in Europe This equipment has been evaluated as EEx nc IIC T4 equipment under DEMKO Certificate No. 03 ATEX 0324020X. Each module is marked II 3G and is suitable for use in Zone 2 hazardous locations. If you are using the NI 9265 in Gas Group IIC hazardous locations or in ambient temperatures of 40 C Ta 70 C, you must use the device in an NI chassis that has been evaluated as EEx nc IIC T4, Ex na IIC T4, or Ex nl IIC T4 equipment. Special Conditions for Marine Applications Some modules are Lloyd s Register (LR) Type Approved for marine applications. To verify Lloyd s Register certification, visit ni.com/certification and search for the LR certificate, or look for the Lloyd s Register mark on the module. Caution To meet radio frequency emission requirements for marine applications, use shielded cables and install the system in a metal enclosure. Suppression ferrites must be installed on power supply inputs near power entries to modules and controllers. Power supply and module cables must be separated on opposite sides of the enclosure and must enter and exit through opposing enclosure walls. NI 9265 Operating Instructions and Specifications 6 ni.com

Connecting the NI 9265 The NI 9265 has a 10-terminal, detachable screw-terminal connector that provides connections for 4 analog output channels. AO0 COM0 AO1 COM1 AO2 COM2 AO3 COM3 Vsup Power Supply COM 0 1 2 3 4 5 6 7 8 9 Figure 2. NI 9265 Terminal Assignments National Instruments Corp. 7 NI 9265 Operating Instructions and Specifications

The NI 9265 has four analog output channels, AO. Each channel has a common terminal, COM, that is internally connected to the isolated ground reference of the module. The 9265 also has a terminal for an external power supply, V sup, and an external power supply common terminal, Power Supply COM. Each AO channel has a digital-to-analog converter (DAC) that produces a current signal. Each channel also has overvoltage and short-circuit protection. Refer to the Specifications section for more information about the overvoltage and short-circuit protection. Refer to Figure 3 for an illustration of the output circuitry for one channel of the NI 9265. You can connect a load to each channel of the NI 9265. Connect the positive lead of the load to the AO terminal. Connect the ground of the load to the corresponding COM terminal. Refer to Figure 3 for an illustration of how to connect a load to the NI 9265. NI 9265 Operating Instructions and Specifications 8 ni.com

External Power Supply _ Power Supply COM Vsup + DC/DC NI 9265 Isolated DAC Protection AO COM Load Figure 3. Connecting a Load to the NI 9265 Note You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9265. National Instruments Corp. 9 NI 9265 Operating Instructions and Specifications

You must connect an external power supply to the NI 9265. This power supply provides the current for the devices you connect to the module. Connect the positive lead of the power supply to the supply terminal, V sup, and the negative lead of the power supply to Power Supply COM. When the module powers on, the channels output the startup current. Refer to the Specifications section for more information about startup current. Refer to the software help for information about configuring startup output states in software. Visit ni.com/info and enter cseriesdoc for information about C Series documentation. Wiring for High-Vibration Applications If an application is subject to high vibration, National Instruments recommends that you either use ferrules to terminate wires to the detachable screw-terminal connector or use the NI 9932 backshell kit to protect the connections. Refer to Figure 4 for an illustration of using ferrules. Refer to Figure 1 for an illustration of the NI 9932 connector backshell. NI 9265 Operating Instructions and Specifications 10 ni.com

Figure 4. 10-Terminal Detachable Screw-Terminal Connector with Ferrule Sleep Mode This module supports a low-power sleep mode. Support for sleep mode at the system level depends on the chassis that the module is plugged into. Refer to the chassis manual for information about support for sleep mode. If the chassis supports sleep mode, refer to the software help for information about enabling sleep mode. National Instruments Corp. 11 NI 9265 Operating Instructions and Specifications

Visit ni.com/info and enter cseriesdoc for information about C Series documentation. Typically, when a system is in sleep mode, you cannot communicate with the modules. In sleep mode, the system consumes minimal power and may dissipate less heat than it does in normal mode. Refer to the Specifications section for more information about power consumption and thermal dissipation. Specifications The following specifications are typical for the range 40 to 70 C unless otherwise noted. All voltages are relative to COM unless otherwise noted. Output Characteristics Number of channels...4 analog output channels DAC resolution...16 bits Type of DAC...String Power-on output state...0 Startup current...0.0 ma Power-down current... 0.0 ma NI 9265 Operating Instructions and Specifications 12 ni.com

Full-scale output current Minimum...20.1 ma Typical...20.6 ma Maximum...21.0 ma Output range...0 to 20 ma Compliance voltage...12 VDC max Maximum load...600 Ω Accuracy Measurement Conditions Percent of Reading (Gain Error) Percent of Range * (Offset Error) Calibrated, typ (25 C, ±5 C) 0.11% 0.19% Calibrated, max ( 40 to 70 C) 0.25% 0.4% Uncalibrated, typ (25 C, ±5 C) 0.35% 1.4% Uncalibrated, max ( 40 to 70 C) 0.85% 2.5% * Range equals 0 to 20.6 ma National Instruments Corp. 13 NI 9265 Operating Instructions and Specifications

Stability Gain drift...30 ppm/ C Offset drift...45 ppm/ C External power supply voltage range (V sup )...9 36 VDC Protection (AO, V sup ) Overvoltage...±40 V Short-circuit...Indefinitely Update time Number of Channels Update Time for R Series Expansion Chassis Update Time for Any Other Chassis One 3.5 μs 3 μs Two 6.5 μs 5 μs Three 9 μs 7.5 μs Four 12 μs 9.5 μs Noise...600 na rms Crosstalk... 90 db NI 9265 Operating Instructions and Specifications 14 ni.com

Settling time (to 1 LSB) Full-scale step...10 μs 1 ma step...5 μs Glitch energy...unmeasurable Monotonicity...16 bits DNL...1 LSB max INL...±16 LSB MTBF...1,014,487 hours at 25 C; Bellcore Issue 6, Method 1, Case 3, Limited Part Stress Method Note Contact NI for Bellcore MTBF specifications at other temperatures or for MIL-HDBK-217F specifications. Power Requirements Power consumption from chassis Active mode...230 mw max Sleep mode...25 μw max National Instruments Corp. 15 NI 9265 Operating Instructions and Specifications

Thermal dissipation (at 70 C) Active mode...1.5 W max Sleep mode...10 mw max Power consumption from external power supply Active mode...1.4 W max Sleep mode...10 mw Physical Characteristics If you need to clean the module, wipe it with a dry towel. Screw-terminal wiring...12 to 24 AWG copper conductor wire with 10 mm (0.39 in.) of insulation stripped from the end Ferrules...0.25 mm 2 to 2.5 mm 2 Torque for screw terminals...0.5 to 0.6 N m (4.4 to 5.3 lb in.) Weight...136 g (4.8 oz) NI 9265 Operating Instructions and Specifications 16 ni.com

Safety Maximum Voltage 1 Connect only voltages that are within the following limits. Channel-to-COM or V sup -to-com...±40 V max Isolation Voltages Channel-to-channel...No isolation between channels Channel-to-earth ground, V sup -to-earth ground, or COM-to-earth ground Continuous...250 V rms, Measurement Category II Withstand...2,300 V rms, verified by a 5 s dielectric withstand test Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as 1 The maximum voltage that can be applied between any channel or V sup terminal and a COM terminal without damaging the module or other devices. National Instruments Corp. 17 NI 9265 Operating Instructions and Specifications

that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe. Caution Do not connect the NI 9265 to signals or use for measurements within Measurement Categories III or IV. Safety Standards This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by module number or product line, and click the appropriate link in the Certification column. Hazardous Locations U.S. (UL)...Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx nc IIC T4 NI 9265 Operating Instructions and Specifications 18 ni.com

Canada (C-UL)...Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex nc IIC T4 Europe (DEMKO)...EEx nc IIC T4 Environmental National Instruments C Series modules are intended for indoor use only but may be used outdoors if installed in a suitable enclosure. Refer to the manual for the chassis you are using for more information about meeting these specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2)... 40 to 70 C Storage temperature (IEC 60068-2-1, IEC 60068-2-2)... 40 to 85 C Ingress protection...ip 40 Operating humidity (IEC 60068-2-56)...10 to 90% RH, noncondensing National Instruments Corp. 19 NI 9265 Operating Instructions and Specifications

Storage humidity (IEC 60068-2-56)...5 to 95% RH, noncondensing Maximum altitude...2,000 m Pollution Degree (IEC 60664)...2 Shock and Vibration To meet these specifications, you must panel mount the system and either affix ferrules to the ends of the terminal wires or use the NI 9932 backshell kit to protect the connections. Operating vibration Random (IEC 60068-2-64)...5 g rms, 10 to 500 Hz Sinusoidal (IEC 60068-2-6)...5 g, 10 to 500 Hz Operating shock (IEC 60068-2-27)...30 g, 11 ms half sine, 50 g, 3 ms half sine, 18 shocks at 6 orientations NI 9265 Operating Instructions and Specifications 20 ni.com

Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: EN 61326 EMC requirements; Industrial Immunity EN 55011 Emissions; Group 1, Class A CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A Note For EMC compliance, operate this device with shielded cabling. CE Compliance This product meets the essential requirements of applicable European directives, as amended for CE markings, as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit National Instruments Corp. 21 NI 9265 Operating Instructions and Specifications

ni.com/certification, search by module number or product line, and click the appropriate link in the Certification column. Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers. For additional environmental information, refer to the NI and the Environment Web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/ environment/weee.htm. NI 9265 Operating Instructions and Specifications 22 ni.com

RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china (For information about China RoHS compliance, go to ni.com/ environment/rohs_china.) Calibration You can obtain the calibration certificate and information about calibration services for the NI 9265 at ni.com/calibration. Calibration interval...1 year National Instruments Corp. 23 NI 9265 Operating Instructions and Specifications

Where to Go for Support The National Instruments Web site is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/support and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725 72511, France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, Italy 39 02 41309277, Japan 0120-527196, NI 9265 Operating Instructions and Specifications 24 ni.com

Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 3390150, Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886, Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377 2222, Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545 National Instruments Corp. 25 NI 9265 Operating Instructions and Specifications

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2005 2008 National Instruments Corp. All rights reserved. 374067E-01 Feb08