TBX-1316 High-Voltage Attenuator Terminal Block

Similar documents
SCXI -1313A Terminal Block

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

SCC-AO10 Isolated Analog Output Module

SCXI OFFSET-NULL AND SHUNT-CALIBRATION HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE

SCC-RLY01 Relay Module

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

TBX-96 TERMINAL BLOCK

You need the following to set up and use your terminal block:

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

NI PXI-1042 Series Power Supply Shuttle

Where to Start with NI ELVIS

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

Where to Start with NI ELVIS

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

CB-27T, TBX-68T, AND CB-68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE

NI PXIe-1062Q Power Supply Shuttle

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

Low-Cost Multifunction DAQ for USB

Electrical. SPECIFICATIONS SH Cable

Ethernet/Serial Interfaces for Compact FieldPoint

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

NI 6521 Specifications

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

NI PXI-2567 Specifications

FP-AO-210 AND CFP-AO-210

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

FP-AO-200 AND CFP-AO-200

1-Wire 4 x 128 Matrix Terminal Block for the NI PXI/PXIe-2532B

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

FP-PS-4. Features. Installation

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

The following conventions appear in this document:

USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

FP-AIO-600 and cfp-aio-600

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

NI 6703/6704 Calibration Procedure for NI-DAQ mx

Low-Cost Digital I/O Device for USB

INSTALLATION INSTRUCTIONS LFH160 Cable

NI crio-9101/9102/9103/9104

Electromagnetic Compatibility Guidelines

NI SMB-2145/2146/2147/2148

Electromagnetic Compatibility Guidelines

Electromagnetic Compatibility Guidelines

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

FP-2000/2010 FieldPoint Quick Start Guide

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Getting Started with the NI 8234

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

Safety and Radio-Frequency Interference

NI Serial Hardware Specifications Guide

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

For NI PXI and NI SCXI Switch Modules

USB-2001-TC. USB-based Thermocouple Input. User's Guide

High-Precision Data Acquisition

Compact FieldPoint cfp-1808

Compact FieldPoint cfp-cal

Getting Started with the NI PCI-1405

Line Impedance Stabilization Network (LISN)

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4339 and TB-4339/B/C 8 Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

ESERIES CALIBRATION FIXTURE INSTALLATION GUIDE

8 AI (12-Bit, 10 ks/s), 2 AO (150 Hz), 12 DIO USB Multifunction I/O Device

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

24-Channel, ±24 V Precision PXI Source Measure Unit

12-Channel, ±24 V Precision PXI Source Measure Unit

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

RTM Contents. Definitions. Conditions SPECIFICATIONS. PCI Express Rear Transition Module for ATCA

Chapter 1 Introducing the OM-USB Functional block diagram... 5

USB Definitions. Conditions. Analog Input SPECIFICATIONS. 8 AI (10 ks/s), 4 DIO USB Multifunction I/O Device

NI TSM-101x. LCD Characteristics NI TSM-1012 NI TSM-1015 SPECIFICATIONS. NI TSM-1012, NI TSM-1015, NI TSM-1017 Touch Screen Monitors

NI PXI Contents CALIBRATION PROCEDURE

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

Nokeval. FD100 series. User Manual

Getting Started with the NI 8234

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

General-Purpose 8-Slot Chassis for PXI

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

Single-Channel Precision System Source Measure Unit (SMU)

NI Safety Guidelines. Safety Guidelines for Hazardous Locations GETTING STARTED GUIDE. Ethernet Expansion Chassis for C Series Modules

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Getting Started with the NI PCI-8254R

Getting Started with the NI PCIe-8253

Transcription:

INSTALLATION GUIDE TBX-1316 High-Voltage Attenuator Terminal Block This guide describes how to install and use the TBX-1316 high-voltage attenuator terminal block with the following modules: SCXI-1125 (recommended) SCXI-1126 SCXI-1120/D The TBX-1316 is a shielded metal enclosure with a built-in high-voltage attenuator. You can use it to measure high-voltage signals of up to 1000 V Category I and 600 V Category II. Caution Do not use the TBX-1316 to connect to signals above 600 V Category II. Do not use the TBX-1316 in Category III or IV applications. Do not connect to MAINS supply circuits above 600 VAC. The TBX-1316 has eight differential high-voltage input channels. Each high-voltage input channel has three screw terminals one each for input plus, input minus, and chassis ground. For maximum safety, all the chassis-ground terminals and the enclosure are connected. You can use 6 to 20 AWG signal wire in the screw terminals. Use an SH3232 shielded cable to connect the TBX-1316 to the module. Note Refer to the Read Me First: Safety and Radio-Interference document for definitions of Categories and other safety information. Caution Do not use uninsulated input signal wires. All input signal wires must be separated from each other and must have a minimum voltage rating of 1000 V for Category I or 600 V for Category II and have a temperature rating of 90 C. Each input channel is formed by a pair of 200:1 fixed-attenuation-ratio high-voltage resistor networks. The nominal inaccuracy of the attenuation factor is < 1%, and the attenuation-ratio drift temperature coefficient is < 20 ppm/ C.

Caution Install an application appropriate UL-Listed external breaker (disconnect) for each input line. Conventions A calibration EEPROM is built into the TBX-1316. When the TBX-1316 is used in conjunction with an SCXI-1125, the EEPROM stores calibration constants. These constants provide software correction values that the application development software uses to correct measurements for gain error in the attenuation circuitry. The EEPROM is shipped with nominal values. Refer to the Calibrating the TBX-1316 section for calibration information. The following conventions are used in this guide:» The» symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this icon is marked on the product, refer to the Read Me First: Safety and Radio-Frequency Interference document, shipped with the product, for precautions to take. When symbol is marked on a product it denotes a warning advising you to take precautions to avoid electrical shock. When symbol is marked on a product it denotes a component that may be hot. Touching this component may result in bodily injury. bold italic monospace Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Bold text also denotes parameter names. Italic text denotes variables, emphasis, a cross reference, or an introduction to a key concept. This font also denotes text that is a placeholder for a word or value that you must supply. Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions. TBX-1316 High-Voltage Attenuator Terminal Block 2 ni.com

What You Need to Get Started To install and use the TBX-1316, you need the following items: Hardware TBX-1316 terminal block One of the following modules: SCXI-1125 (recommended) SCXI-1126 SCXI-1120/D One of the following chassis: SCXI PXI/SCXI combination One of the following: E/M Series DAQ PCI device E/M Series DAQ PXI module SH3232 shielded cable and cable adapter as required for your application Documentation Read Me First: Safety and Radio-Frequency Interference DAQ Quick Start Guide SCXI Quick Start Guide TBX-1316 High-Voltage Attenuator Terminal Block Installation Guide One of the following user manuals (application-dependent): SCXI-1125 User Manual SCXI-1126 User Manual SCXI-1120/D User Manual SCXI or PXI/SCXI combination chassis user manual Tools Number 1 and 2 Phillips screwdriver 1/8 and 3/8 in. flathead screwdriver Long nose pliers Wire cutter National Instruments Corporation 3 TBX-1316 High-Voltage Attenuator Terminal Block

Wire insulation stripper Miscellaneous tools to permanently mount the enclosure Installing the TBX-1316 Enclosure Note Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers or connecting or disconnecting any signal wires. To install the TBX-1316 enclosure, complete the following steps: 1. Install an application appropriate UL-Listed external breaker (disconnect) for each input line as follows: a. Install the disconnect device(s) within close proximity of the TBX-1316 and within easy reach of the operator. b. Mark this enclosure as a disconnect device. Note The TBX-1316 is intended for mounting in a permanent location. NI recommends installing the enclosure in a permanent location whenever possible. 2. Securely mount the enclosure to the building per the local safety codes. If the enclosure is mounted on plaster board (drywall), mount the enclosure using four #14 1 1/2 in. wood screws installed through the four, 7.6 mm (0.3 in.) clearance mounting holes. Position the enclosure so that all four screws are driven into wooden studs. Figure 1 shows the clearance holes. 3. While referring to Figure 2, unlock and open the enclosure door using a 3/8 in. flathead screwdriver. 4. While referring to Figure 3, complete the following steps to install the protective earth (PE) ground wire. Note The PE ground wire must comply with your local codes and be the same or larger size AWG as the input signal wires. a. Insert the PE ground wire through the PE ground strain-relief collar. b. Install a UL-Listed uninsulated closed-ring terminal, suitable to your application, on the end of the PE ground wire. c. Place the lock-washer over the ground-screw followed by the PE ground terminal. d. Place the provided lock washer over the end of the ground screw. The screw should now have a ring terminal between two lock washers. TBX-1316 High-Voltage Attenuator Terminal Block 4 ni.com

e. Install the ground-screw/lock-washer into the enclosure, and tighten it with a number 2 Phillips screwdriver. f. Tighten the PE ground strain-relief collar. 304.80 mm [12.000 in] 323.85 mm [12.750 in] 342.90 mm [13.500 in] 1000 V CAT I 600 V CAT II 50 µa MAX per channel 9.53 mm [0.375 in] 25.4 mm [1.000 in] 203.20 mm [8.000 in] 254.00 mm [10.000 in] Figure 1. TBX-1316 Enclosure Mounting Hole Spacing National Instruments Corporation 5 TBX-1316 High-Voltage Attenuator Terminal Block

Connecting the Signals Note Be certain that the signal wires are of the appropriate AWG and voltage for your application, and are rated for 90 C. To connect a signal to the TBX-1316, perform the following steps while referring to Figures 2 and 3: 1. Unlock and open the enclosure door using a 3/8 in. flathead screwdriver. Figure 2. Opening the TBX-1316 2. Loosen the signal strain-relief collar. 3. Run the signal wires through the strain-relief opening. 4. Prepare the signal wire by stripping the insulation no more than 10 mm (0.39 in.). Note When connecting the signals to the TBX-1316, follow the labeling on the TBX-1316. TBX-1316 High-Voltage Attenuator Terminal Block 6 ni.com

5. Connect chassis ground to the chassis-ground terminal strip. 6. Connect the signal wires to the signal wire screw terminals by inserting the stripped end of the wire fully into the terminal. Caution No bare wire should extend past the screw terminal. Exposed wire increases the risk of short circuits and failures. 7. Tighten the terminal screws to a torque of 1.2 to 1.5 N m (10.62 to 13.28 in. lb). 8. Tighten the signal strain-relief collar. 9. Repeat steps 2 through 8 for each signal wire. 10. Close and lock the enclosure door. 11. Connect the TBX-1316 to the SCXI module front connector as explained in the Connecting the Module section. National Instruments Corporation 7 TBX-1316 High-Voltage Attenuator Terminal Block

8 6 7 9 5 4 3 10 11 12 2 1 13 1 Protective Earth Ground Strain-Relief Collar 2 Protective Earth Ground 3 Signal Cable Insulation 4 Signal Wire Insulation 5 Enclosure Door Lock 6 Enclosure Door 7 Enclosure Door Ground 8 SH3232 Shielded Cable Connector 9 Protective Cover 10 Signal Wire Terminal Strip 11 Chassis Ground Terminal Strip 12 Enclosure 13 Signal Strain-Relief Collar Figure 3. TBX-1316 Parts Locator Diagram Connecting the Module This section describes how to connect the TBX-1316 to an SCXI and PXI/SCXI combination chassis. Note The illustrations show the SCXI chassis only. TBX-1316 High-Voltage Attenuator Terminal Block 8 ni.com

To connect the TBX-1316 to an SCXI module front connector, perform the following steps: 1. If you have not already installed the E/M Series DAQ device, refer to the DAQ Quick Start Guide for installation instructions. 2. If you have not already installed the SCXI module, refer to the SCXI Quick Start Guide for installation instructions. 3. Power off the SCXI chassis. 4. Do one of the following: Power off the computer that contains the E/M Series DAQ device, and disconnect the device from the chassis. Power off the PXI portion of the PXI/SCXI combination chassis, and if used, remove the cable connecting the SCXI portion of the chassis to E/M Series device. 5. Connect the TBX cable adapter to the appropriate SCXI module, and secure it by tightening both thumbscrews, as shown in Figure 4. 4 3 2 5 4 3 2 1 ADDRESS 5 1 3 1 Mounting Screws and Ears 2 Cable 3 Thumbscrews 4 SCXI Chassis 5 TBX Cable Adapter Figure 4. Connecting the Cable to the SCXI Module National Instruments Corporation 9 TBX-1316 High-Voltage Attenuator Terminal Block

6. Connect one end of the cable assembly to the SH3232 shielded cable connector on the TBX-1316, and secure the cable by tightening both mounting screws, as shown in Figure 5. 1 2 1 1 Mounting Screws 2 Cable Assembly Figure 5. Connecting the Cable to the TBX-1316 TBX-1316 High-Voltage Attenuator Terminal Block 10 ni.com

7. Connect the other end of the cable assembly to the SCXI module front connector, and secure the cable by tightening the mounting screws. Figure 6 shows the completed installation. 5 4 3 2 1 ADDRESS Calibrating the TBX-1316 Figure 6. Completed Installation 8. If necessary, reconnect the E/M Series DAQ device to the chassis. 9. Refer to the SCXI Quick Start Guide to power on the SCXI chassis and configure the system in software. NI recommends you perform an external calibration once a year. You can download all available external calibration documents from ni.com/calibration by clicking Manual Calibration Procedures. National Instruments Corporation 11 TBX-1316 High-Voltage Attenuator Terminal Block

Specifications Input Voltage Range All specifications are typical at 25 C unless otherwise specified. AC/DC...1000 V Category I AC/DC...600 V Category II Max input current per channel...50 µa Impulse overvoltage...4000 V Bandwidth (3 db) SCXI-1125...400 Hz SCXI-1120...400 Hz Attenuation ratio...200:1 (fixed) Attenuation-ratio accuracy Uncalibrated...1% max Attenuation-ratio temperature drift...20 ppm/ C max Differential input resistance...44 MΩ typ Physical NI recommends that the TBX-1316 be permanently connected equipment with an appropriate UL Listed external breaker for each line. Enclosure protective earth (PE) ground must be installed. Dimensions...30.48 25.40 15.24 cm (12 10 6 in.) Weight...5.8 kg (12.8 lb) Strain-relief cable diameter...6 to 12 mm signals (0.24 to 0.47 in.) 4 to 8 mm PE ground (0.157 to 0.314 in.) TBX-1316 High-Voltage Attenuator Terminal Block 12 ni.com

Note If your application cable diameter is smaller than what is listed above, replace the supplied strain reliefs with the following strain reliefs or their equivalents. These strain reliefs are not supplied with the TBX-1316. Strain-relief cable diameter... 5 to 9 mm signals (0.197 to 0.354 in.) SKINTOP # S2213 2 to 6 mm PE ground (0.079 to 0.236 in.) SKINTOP # S2209 Strain reliefs available... 8 signals 1 PE ground Field wire Diameter... 6 to 20 AWG Temperature rating... 90 C Connector type... Screw terminal Environmental Operating temperature... 0 to 55 C Storage temperature... 20 to 70 C Humidity... 10 to 90% RH, noncondensing Maximum altitude... 2,000 m Pollution Degree (indoor use only)... 2 Safety The TBX-1316 is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1 CAN/CSA-C22.2 No. 61010-1 Note For UL and other safety certifications, refer to the product label, or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. National Instruments Corporation 13 TBX-1316 High-Voltage Attenuator Terminal Block

Electromagnetic Compatibility Emissions...EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity...EN 61326:1997 + A2:2001, Table 1 EMC/EMI...CE, C-Tick, and FCC Part 15 (Class A) Compliant Note For EMC compliance, operate this device with shielded cabling. CE Compliance The TBX-1316 meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: Low-Voltage Directive (safety)...73/23/eec Electromagnetic Compatibility Directive (EMC)...89/336/EEC Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. TBX-1316 High-Voltage Attenuator Terminal Block 14 ni.com

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2004 2005 National Instruments Corporation. All rights reserved. 374061C-01 Apr05