Post-mission Adjustment Methods of Airborne Laser Scanning Data

Similar documents
REGISTRATION OF AIRBORNE LASER DATA TO SURFACES GENERATED BY PHOTOGRAMMETRIC MEANS. Y. Postolov, A. Krupnik, K. McIntosh

Planimetric and height accuracy of airborne laserscanner data: User requirements and system performance

; < /$6(5675,3$'-8670(17)25'$7$&$/,%5$7,21$1'9(5,),&$7,21. 5 = misalignment between laser and IMU. Helén Burman

Airborne Laser Survey Systems: Technology and Applications

A QUALITY ASSESSMENT OF AIRBORNE LASER SCANNER DATA

Performance Evaluation of Optech's ALTM 3100: Study on Geo-Referencing Accuracy

TerraMatch. Introduction

Processing of airborne laser scanning data

LIDAR SYSTEM SELF-CALIBRATION USING PLANAR PATCHES FROM PHOTOGRAMMETRIC DATA

SURFACE ESTIMATION BASED ON LIDAR. Abstract

KEY WORDS: Laser altimetry, Error recovery, Strip adjustment, Segmentation

ifp Universität Stuttgart Performance of IGI AEROcontrol-IId GPS/Inertial System Final Report

Marc Crombaghs, Sander Oude Elberink, Regine Brügelmann, Erik de Min

AUTOMATIC IMAGE ORIENTATION BY USING GIS DATA

Chapters 1 9: Overview

Airborne LIDAR borsight error calibration based on surface coincide

RIGOROUS LIDAR STRIP ADJUSTMENT WITH TRIANGULATED AERIAL IMAGERY Yongjun Zhang*, Xiaodong Xiong, Xiangyun Hu

ICC experiences on Inertial / GPS sensor orientation. A. Baron, W.Kornus, J.Talaya Institut Cartogràfic de Catalunya, ICC

ANALYSIS AND ACCURACY ASSESSMENT OF AIRBORNE LASERSCANNING SYSTEM

COMPARATIVE ANALYSIS OF DIFFERENT LIDAR SYSTEM CALIBRATION TECHNIQUES

The Applanix Approach to GPS/INS Integration

Phone: Fax: Table of Contents

Phone: (603) Fax: (603) Table of Contents

THE INTERIOR AND EXTERIOR CALIBRATION FOR ULTRACAM D

Automating Data Alignment from Multiple Collects Author: David Janssen Optech Incorporated,Senior Technical Engineer

HEURISTIC FILTERING AND 3D FEATURE EXTRACTION FROM LIDAR DATA

INVESTIGATING ADJUSTMENT OF AIRBORNE LASER SCANNING STRIPS WITHOUT USAGE OF GNSS/IMU TRAJECTORY DATA

Mapping Project Report Table of Contents

AIRBORNE LASER SCANNING STRIP ADJUSTMENT AND AUTOMATION OF TIE SURFACE MEASUREMENT 1

William E. Dietrich Professor 313 McCone Phone Fax (fax)

1. LiDAR System Description and Specifications

Chapter 1: Overview. Photogrammetry: Introduction & Applications Photogrammetric tools:

[Youn *, 5(11): November 2018] ISSN DOI /zenodo Impact Factor

Automatic DTM Extraction from Dense Raw LIDAR Data in Urban Areas

HAWAII KAUAI Survey Report. LIDAR System Description and Specifications

Building Segmentation and Regularization from Raw Lidar Data INTRODUCTION

WAVELET AND SCALE-SPACE THEORY IN SEGMENTATION OF AIRBORNE LASER SCANNER DATA

ADS40 Calibration & Verification Process. Udo Tempelmann*, Ludger Hinsken**, Utz Recke*

There are an increasing number

UCGE Reports Number 20179

AUTOMATIC TIE ELEMENTS DETECTION FOR LASER SCANNER STRIP ADJUSTMENT

REFINEMENT OF FILTERED LIDAR DATA USING LOCAL SURFACE PROPERTIES INTRODUCTION

Airborne Laser Scanning and Derivation of Digital Terrain Models 1

Assessing the Performance of Different Direct-Georeferencing with Large Format Digital Cameras

APPLICATION AND ACCURACY EVALUATION OF LEICA ADS40 FOR LARGE SCALE MAPPING

COMBINED BUNDLE BLOCK ADJUSTMENT VERSUS DIRECT SENSOR ORIENTATION ABSTRACT

Third Rock from the Sun

A METHOD TO PREDICT ACCURACY OF LEAST SQUARES SURFACE MATCHING FOR AIRBORNE LASER SCANNING DATA SETS

Least-Squares Matching with Airborne Laserscanning Data in a TIN Structure

Light Detection and Ranging (LiDAR)

DISSERTATION. The Degree Doctor of Philosophy in the Graduate. School of The Ohio State University. Nora Csanyi May, M.S. *****

Up to 4 range measurements per pulse, including last 4 Intensity readings with 12-bit dynamic range for each measurement

Exterior Orientation Parameters

CALIBRATION PROCEDURES OF THE IMAGING LASER ALTIMETER AND DATA PROCESSING

Terrain Modeling and Mapping for Telecom Network Installation Using Scanning Technology. Maziana Muhamad

LIDAR MAPPING FACT SHEET

Aalborg Universitet. Published in: Accuracy Publication date: Document Version Early version, also known as pre-print

Terrestrial GPS setup Fundamentals of Airborne LiDAR Systems, Collection and Calibration. JAMIE YOUNG Senior Manager LiDAR Solutions

The suitability of airborne laser scanner data for automatic 3D object reconstruction

LiDAR data pre-processing for Ghanaian forests biomass estimation. Arbonaut, REDD+ Unit, Joensuu, Finland

Assimilation of Break line and LiDAR Data within ESRI s Terrain Data Structure (TDS) for creating a Multi-Resolution Terrain Model

Airborne Laser Scanning: Remote Sensing with LiDAR

DOCUMENTATION AND VISUALIZATION OF ANCIENT BURIAL MOUNDS BY HELICOPTER LASER SURVEYING

MODELLING FOREST CANOPY USING AIRBORNE LIDAR DATA

Neusiedler See project

LIDAR Data for Photogrammetric Georeferencing

BUNDLE BLOCK ADJUSTMENT WITH HIGH RESOLUTION ULTRACAMD IMAGES

University of Technology Building & Construction Department / Remote Sensing & GIS lecture

MONO-IMAGE INTERSECTION FOR ORTHOIMAGE REVISION

Planimetric offset adjustment of multitemporal laser scanner data

Final Report FWHA/INDOT/JTRP-2006/23 CORRIDOR MAPPING USING AERIAL TECHNIQUE. James S. Bethel Professor of Civil Engineering

On the Selection of an Interpolation Method for Creating a Terrain Model (TM) from LIDAR Data

The YellowScan Surveyor: 5cm Accuracy Demonstrated

N.J.P.L.S. An Introduction to LiDAR Concepts and Applications

LiDAR & Orthophoto Data Report

Processing of laser scanner data algorithms and applications

PERFORMANCE ANALYSIS OF FAST AT FOR CORRIDOR AERIAL MAPPING

GPS SUPPORTED AERIAL TRIANGULATION USING UNTARGETED GROUND CONTROL

RANSAC APPROACH FOR AUTOMATED REGISTRATION OF TERRESTRIAL LASER SCANS USING LINEAR FEATURES

Matching Topographic Surfaces: Application to lidar and photogrammetric surfaces.

Simulating Dynamic Hydrological Processes in Archaeological Contexts Mapping Project Report

Lidar Technical Report

DETERMINATION OF IMAGE ORIENTATION SUPPORTED BY IMU AND GPS

Generate Digital Elevation Models Using Laser Altimetry (LIDAR) Data

Hands-on practice: LIDAR data quality analysis and fine-georeferencing

Title: Understanding Hyporheic Zone Extent and Exchange in a Coastal New Hampshire Stream Using Heat as A Tracer

Experiments on Generation of 3D Virtual Geographic Environment Based on Laser Scanning Technique

Quantifying the Geomorphic and Sedimentological Responses to Dam Removal. Mapping Project Report

DIGITAL TERRAIN MODEL USING LASER SCANNING IN THE NEAPOLITAN VOLCANIC AREA. DAUR - University of Padua (2) DISTART - University of Bologna (3)

Automatic Building Extrusion from a TIN model Using LiDAR and Ordnance Survey Landline Data

Project Report Nooksack South Fork Lummi Indian Nation. Report Presented to:

PERFORMANCE ANALYSIS OF ALTM 3100EA: INSTRUMENT SPECIFICATIONS AND ACCURACY OF LIDAR DATA

ALS40 Airborne Laser Scanner

THE USE OF ANISOTROPIC HEIGHT TEXTURE MEASURES FOR THE SEGMENTATION OF AIRBORNE LASER SCANNER DATA

An Education Tool. Airborne Altimetric LiDAR Simulator:

INTEGRATED SENSORS FOR PLATFORM ORIENTATION AND TOPOGRAPHIC DATA ACQUISITION

AN INTEGRATED SENSOR ORIENTATION SYSTEM FOR AIRBORNE PHOTOGRAMMETRIC APPLICATIONS

USING ROAD PAVEMENT MARKINGS AS GROUND CONTROL FOR LIDAR DATA

SPAR, ELMF 2013, Amsterdam. Laser Scanning on the UK Highways Agency Network. Hamish Grierson Blom Uk

A COMPETITION BASED ROOF DETECTION ALGORITHM FROM AIRBORNE LIDAR DATA

Transcription:

Kris MORIN, USA and Dr. Naser EL-SHEIMY, Canada Key words: ALS, LIDAR, adjustment, calibration, laser scanner. ABSTRACT Airborne Laser Scanners (ALS) offer high speed, high accuracy and quick deployment in the field. These attributes have contributed to their growing use. To date however, there has been a lack of common calibration methods; especially on the commerical market. Users are often left to develop their own methods which is time consuming and labour intensive. This paper reviews the effects of miscalibration on the derived terrain data, covers current methods of calibration and suggests a new adjustment model that allows for the parameterization of ALS scanner errors. Using data from a Leica Geosystems ALS4, the results of the new adjustment model show that a calibration solution can be obtained without the need of surveyed ground control points. Other results indicate that tie point selection is an important factor on the quality and consistency of the calibration model. CONTACT Kris Morin, Geomatics Engineer Leica Geosystems 1965 Via Frontera San Diego, CA 92128 USA Tel. +1 858 675 3335 Fax + 1 858 675 3345 E-mail: morin@lh-systems.com Web site: http://www.lh-systems.com Dr. Naser El-Sheimy, Chair FIG Commission 5 WG 3 Department of Geomatics Engineering The University of Calgary, Canada 25 University Drive N.W. Calgary, AB T2N 1N4, CANADA Tel. + 1 43 22 7587 Fax + 1 43 284 198, E-mail: naser@geomatics.ucalgary.ca Web site: http://www.geomatics.ucalgary.ca/~nel-shei/ 1/12 Washington, D.C. USA, April 19-26 22

Kris MORIN, USA and Dr. Naser EL-SHEIMY, Canada INTRODUCTION Airborne Laser Scanning (ALS) systems are gaining in popularity due to their high accuracy, quick deployment and delivery and high automation. Multiple products such as bald Earth, forest stand counting and building delineation can be automatically extracted from a single dataset (Axelsson 2). ALS systems are relatively lightweight and can be deployed in standard aircraft (Leica Geosystems 22). As more systems operate however, the demand for standard solutions to common operating issues is increasing. These demands include postprocessing software and calibration/alignment issues. While commercial products have begun appearing for post-processing (Terrasolid 22, Leica 22), many users are left to develop their own methods for calibration; which can be both a time consuming and knowledge intensive operation. This paper will review some current methods of ALS calibration, and report on an ongoing project to automate the calibration of several major parameters. CALIBRATION ERRORS ALS systems are the combination of several surveying technologies. While there are differences between commercial systems, the basic package remains the same: a Global Positioning System (GPS) receiver and an Inertial Navigation System (INS) as the navigation component, and laser range finder and a scanner as the remote sensing component (Wehr 1999). Each component requires calibration and the offsets between the components needs to be determined. GPS/INS and range finders are usually calibrated in the lab; thus this paper will concentrate on scanner and misalignment (bore sight) values. The misalignment between the INS system and the scanner is the largest source of systematic error in an ALS and must be addressed before the sensor can be effectively deployed. It has been observed empirically that these misalignment errors are often relatively small (.1 3 degrees), but their effect on the recorded ground points will depend on flying height and the scanner field of view (maximum scan angle) (Burman 2b). When comparing data from overlapping strips on an un-calibrated system, the effects of these errors will be seen as in Figure 1 (next page): On systems using an oscillating scanner (such as the Leica ALS4 and the Optech ALTM), additional errors can be visible when comparing strips (Crombaugh et al. 2) (Figure 2): 2/12 Washington, D.C. USA, April 19-26 22

Recorded point Observed range Line of flight Φ Line of flight Into the page Κ Line of flight Observed range Ω Observed range Recorded point Pitch Induced Error Φ Recorded point Roll Induced Error Ω Heading Induced Error Κ Figure 1: Boresight Induced Errors Line of flight Into the page Scanner induced error β corrected scan angle β error induced scan angle True ground Figure 2: Scanner Induced Errors These additional effects are caused by errors in the angle encoder. As the mirror accelerates and decelerates across its swath, the angle encoder undergoes small amounts of torsion. This torsion causes a small, but systematic misreading of the angle, which is manifested by the ends of the scan rising too high or dropping too low. Due to the systematic nature of this error, it can be modeled and removed during the calibration process. Washington, D.C. USA, April 19-26 22 3/12

Overlap area for tie point measurement Figure 3: Desired ALS Data for Calibration Testing To determine the calibration parameters empirically, data from overlapping strips must be collected. Alternatively, data from one strip can be compared to a known surface. The misalignment errors and scanner errors described above are all correlated with the direction of flight. If strips are flown in opposite directions, then the induced errors will be maximized and more importantly de-correlated (Burman 2b). This will allows for a least-squares approach to the problem. CALIBRATION METHODS Currently the most common method of calibrating an ALS sensor is also the least rigorous: profiles of overlapping strips are compared and an experienced operator manually adjusts the misalignment angles until the strips appear to visually fit. Although pragmatic, this approach is time consuming and labour intensive; and the results do not immediately provide any statistical measure on the quality of the calibration. More rigorous methods begin with the observation that the ALS misalignment problem appears to be no more than a classical photogrammetric problem in which the coordinates of the observed points need to be transformed into a target reference frame, i.e.: X Y Z t arg et frame = R observation to t arg et rotation R misalignment x y z observation frame (1) 4/12 Washington, D.C. USA, April 19-26 22

A user should be able to determine the value of the misalignment matrix by using surveyed control points and inverting the solution. Unfortunately with ALS data, this is not a trivial task. Unlike photogrammetry, the data is not collected on a frame or strip basis but rather point-by-point; and for each point, the aircraft is at a new position and orientation. The points are distributed in a pseudo-random manner along the scanner path (typically a Z shape for oscillating scanners) the user has no control over what the laser hits; thus signalized control points are difficult to observe. As the laser propagates through the atmosphere, the beam diverges. When its hits the ground it can be in excess of 3 cm in diameter thus measuring edges is difficult as well. In spite of these difficulties, several methods have been developed to help determine tie points between ALS strips and allow for a least-squares adjustment using Eq 1. The simplest way of collecting tie points is to measure them manually in a digital photogrammetric suite. The random points are gridded and then represented in a raster form. The user picks off common features between the strips or attempts to measure known control points (Kilian, J, Haala, N., Englich, M, 1996). This method depends on an experienced user and is time consuming; but when used with a least-squares adjustment, produces results that can be statistically analyzed. The next evolution to this method is to employ an automated area matching technique to pick out common features between strips. This method (Burman 2a) relies on areas with high gradients in the data to provide a sharp signal to match. When using elevation data alone however, this is a problem due to the poor edge-capture ability of ALS systems. This can be partially addressed by matching patches (Maas 2). To improve results further, Maas and Vosselman (2) matched patches directly from a Triangulated Irregular Network (TIN) structure holding the raw ALS observations. This method provided good matching of points, but automatically determining a feature from elevation data alone was still problematic. Another approach to tie point selection is to match features such as entire buildings or roadways (Morin and El-Sheimy, 21a). Rather than relying on a small set of observations, features are parameterized using large numbers of observations to increase the accuracy of the feature models. Common features can then be compared in the latter ALS adjustment to determine the calibration parameters. ADJUSTMENT MATH MODELS Each ground or tie point from an ALS can be described as a parametric equation, as follows: X Y Z ground control X = Y Z aircraft position + R body to frame ground rotation R misalignment l l l x y z laser range components (2) where: 5/12 Washington, D.C. USA, April 19-26 22

(X,Y,Z) ground control is the derived terrain point (X,Y,Z) aircraft position is the aircraft position at the observation epoch R body to ground rotation is the rotation cosine matrix from the aircraft body frame to the ground frame (l x,l y,l z ) laser range are the laser range components derived from the laser range and scanner angle. The solution to R misalignment can be found by using the ALS observations (aircraft position, body frame rotation, laser range) and surveyed control points (X,Y,Z). The values for R misalignment can be solved using a standard least-squares method. If R misalignment were a cosine direction matrix containing the full sin and cosine terms, then the solution would be nonlinear and it would need to be iterated to obtain the misalignment parameters. As noted earlier however, it has been seen empirically that the misalignment angles are often < 3 degrees. The misalignment matrix R misalignment can therefore be replaced by a small-angle approximation: R misalignment where: ω,ф,κ 1 = κ φ κ 1 ω φ ω 1 are the roll, pitch and heading misalignment angles This matrix is linear with respect to the unknowns, which results in a direct solution of the misalignment angles without iteration or the need for an initial approximation. Equation 2 relies on surveyed ground control points to perform the adjustment. Although this may be practical when operating a sensor from a home base, a solution that does not require control points is highly desirable to allow for a more generic calibration method that can be used in the field. This can be achieved by replacing the control points with the constrained average of the tie point observations. This method assumes that the average value of a single point, observed in multiple strips will approximate the true location of the point. This assumption is only valid if the strips were collected in such a way that the errors are decorrelated (as described in Calibration Errors). The new model is similar to Equation 2, (3) X Y Z X Y Z where: average where : average X = Y Z 1 = n aircraft position X Y Z + R body to frame ground rotation R misalignment l l l x y z laser range components (4) 6/12 Washington, D.C. USA, April 19-26 22

n is the number of points used to parameterize the tie point This model must be iterated so that the average constraints are updated for each correction of the calibration parameters. This method allows the tie points in the different strips to converge to a common point without the need for surveyed ground control. Due to the random nature of the ALS ground point observations, data entered in the leastsquares equations is usually interpolated rather than a true observed point. Any point within the coverage area can be indexed by time and referenced to the aircraft position. From there the theoretical values for laser range and scanner angle can be computed. The interpolated observations are suitable for adjustments that solve for bore sight angles only, but when scanner corrections are modeled, this method begins to break down. Scanner corrections are dependent on scanner position and acceleration. Although a scanner position can be interpolated for a tie point, acceleration cannot be. Only true observations can be used to model scanner errors, thus true observations must appear in the adjustment model. The new model proposed here addresses the need for true observations by incorporating the tie point interpolation within the adjustment model. The methodology begins by searching out the nearest true observations of the collected tie point within the ALS dataset. The tie point is then parameterized as a function of distances from the nearest true points, i.e.: X Y Z 1 = n X Y Z observed observed observed + dx + dy + dz where: dx,dy,dz are the intial distances between the measured tie point and the uncorrected, observed ALS ground point. (X,Y,Z) observed are the updated ALS ground points using Equation 4. The averages can be simple or inverse distance weighted. The observation equation for the adjustment then changed to: (5) X Y Z average 1 = n n i= X Y Z aircraft position + R body frame to ground rotation R misalignment l l l x y z laser range components dx + dy dz tiepo dis tan int ces (6) Although a single tie point observation equation now contains several ALS observations, they are a linear combination and the partial derivatives for the design matrices are just the weighted average of the partial derivatives of each observation. In addition to the misalignment parameters, corrections for scanner errors are also included in Washington, D.C. USA, April 19-26 22 7/12

the laser range components vector. These parameters correct the scan angle for the latency and acceleration effects. Models vary from system to system and are generally kept internal to the system. The scanner correction model used in this project has 2 parameters. TEST DATA For this project, data was collected using a Leica Geosystems ALS4 (Leica 22). The test area was a small municipal airport in Fitchburg, Massachusetts. Data was collected in the clover leaf fashion (see Calibration Errors) with 2 strips flown at 8m and a field of view of 32.3 degrees, and a third strip flown at 16m with a field of view of 18 degrees. The data was collected with a pulse rate of 28kHz and a scan rate of 25Hz. This resulted in an overlapping area of (46 by 42 metres) which contained approx 9, points spaced roughly every 1 metre. The test area contained 435 known points over the runway area. This project is proceeding on a phased basis, with the first phase intended to test the adjustment model. For this phase, tie points have been collected manually using a digital photogrammetric workstation. Although not optimal, this provided tie point data of sufficient quality to test the adjustment model. In addition to the tie points, the known points were measured in the data and used to compare the solutions with and without control. RESULTS The following tables summarize the adjustment results using different combinations of control points, tie points and adjustment models. The two models tested were a solution for the bore sight angles only and a 5-parameter solution that contained 2 scanner corrections. The inputs indicate what values were adjusted. The solutions are the misalignment angles determined by the adjustment. The RMS values are a comparison of the residual errors from the adjusted points to the control or average tie point values. For control points, more weighting was applied to the elevation values to compensate for the inaccuracies in manually measuring the points. The elevation residual plots help to indicate whether there is any systematic error remaining in the solution. Systematic errors are usually present when the residuals are not centered on zero or demonstrate a non-normal distribution. In general, the results (Tables, following pages) from the bore sight only adjustment seem to show that a fairly good result can be obtained from the misalignment angles only. The adjustment with the control points gives a solution that tends to agree with the non-control point solutions. An important observation from the residual plot however is that there is still some systematic error present. This is most likely caused by unmodeled errors in the GPS/INS system and would require additional strip adjustment to remove (Morin and El- Sheimy 21b). 8/12 Washington, D.C. USA, April 19-26 22

Bore Sight Only Adjustment Model Adjustment Parameters Elevation Residual Plot 138 Control Points weighted to favor elevation over planimetric control 3:1 Ω: -1.188349 Φ: 1.25353 Κ: -.243868 RMS control (m): Z:.626m 12 1 8 6 4 2 -.5 -.45 -.4 -.35 -.3 -.25 -.2 More 138 tie points with no control. Tie points were weighted to favor elevation 3:1. Ω: -1.1839 Φ: 1.24875 Κ: -.239326 RMS tie points (m): Z:.155m 9 tie points with no control. Planimetric and elevation weighted equally. Ω: -1.19834 Φ: 1.25547 Κ: -.212592 RMS tie points (m): X:.621 Y:.68 Z:.142 9 tie points (equal weight XYZ) 138 tie points (preferring Z) Ω: -1.183779 Φ: 1.248215 Κ: -.232514 RMS tie points (m): X:.572 Y:.622 Z:.154 12 1 7 6 5 4 3 2 1 8 6 4 2-1 12 1 8 6 4 2 -.2 -.2 -.15 -.15 -.8 -.6 -.4 -.2 -.1 -.1 -.5 -.5.5.2.4.6.8 1 More.1.15.2.5.1.15.2 9/12 Washington, D.C. USA, April 19-26 22

Bore sight and Scanner Correction Adjustment Model Adjustment Parameters Elevation Residual Plot 138 Control Points weighted to favor elevation over planimetric control 3:1 Ω: -1.188636 Φ: 1.253459 Κ: -.24749 RMS control (m): Z:.622 8 7 6 5 4 3 2 1 -.56 -.51 -.46 -.41 -.36 -.31 -.26 -.21 -.16 -.11 138 tie points with no control. Tie points were weighted to favor elevation 3:1. Ω: -1.182895 Φ: 1.24818 Κ: -.239492 RMS tie points (m): Z:.155 1 8 6 4 2 -.2 -.15 -.1 -.5.5.1.15.2 9 tie points with no control. Planimetric and elevation weighted equally. Ω: -1.185449 Φ: 1.247678 Κ: -.176292 RMS tie points (m): X:.675 Y:.574 Z:.148 9 tie points (equal weight XYZ) 138 tie points (preferring Z) Ω: -1.183727 Φ: 1.24863 Κ: -.232476 RMS tie points (m): X:.58 Y:.612 Z:.155 6 5 4 3 2 1-1 1 8 6 4 2 -.2 -.15 -.8 -.6 -.4 -.2 -.1 -.5.2.4.6.8.5.1.15 1 More.2 1/12 Washington, D.C. USA, April 19-26 22

The adjustment with 9 tie points shows that an approximate solution can still be found without a large number of observations. This can be useful for quickly determining a misalignment to be used as an approximate value in further modeling although the small number of observations makes it difficult to judge whether the residuals are normally distributed. The remaining solutions with 138 tie points and 138 + 9 tie points both result in similar solutions and similar RMS values. The shape of the residual plot however seems to indicate that there are additional errors going unmodeled in the solution. The adjustment with scanner corrections shows some similar trends with the bore sight only adjustment. The control point solution varies slightly from the bore sight only solution and the residual plot shows the same systematic bias. A slightly smaller RMS value however could indicate that the additional parameters are absorbing some of the error. An important difference in these adjustments is the residual plots from the 138-point solution and the 138 + 9 solution. The 138-solution shows the same residual distribution as the bore sight only solution. The 138 + 9 however shows a much more regular distribution; suggesting that a systematic error has been successfully removed. The difference in the inputs is the quality of the planimetric observations of the additional 9 tie points. The effect on the results would indicate that higher precisions in planimetric observations are required to properly model scanner errors. Overall, it appears that the strips used in these adjustments have a relative accuracy of approximately 15 cm taken from a flying height of 8 16 metres. CONCLUSIONS This phase of the ALS calibration project had the goal of testing new adjustment models for the sensor misalignment angles and scanner corrections. A new model was implemented that incorporated the interpolation of tie points within the least-squares adjustment. This change allowed for the modeling of scanner errors within the adjustment. Eight tests were undertaken to determine the best fitting misalignment angles. The results indicated that: 1. Errors from the navigation system remain in the solution and require additional adjustment 2. A solution can be found without the need for control points 3. A quick and moderately precise solution can be determined from only a few tie points 4. Higher accuracy planimetric tie points are required to fully model errors in the system. The next phase of this project will involve addressing the tie point selection process. The automated selection and processing of points should help in determining and accurate and consistent model of the calibration parameters. With a good calibration, ALS systems can continue to achieve high quality results for 21 st century mapping. 11/12 Washington, D.C. USA, April 19-26 22

REFERENCES Axelsson, P., Processing of laser scanner data - algorithms and applications,isprs Journal of Photogrammetry & Remote Sensing, v54, Elsevier, 138-147, 1999. Behan, A., Mass, H-G, Vosselman, G., Steps towards Quality Improvement of Airborne Laser Scanner Data, Internet Publication, Delft University of Technology, Faculty of Civil Engineering and Geosciences, Section of Photogrammetry and Remote Sensing, 2 Burman(a), H., Adjustment of Laser Scanner Data for Correction of Orientation Errors, International Archives of Photogrammetry and Remote Sensing, Vol. XXXIII, Part B3, Amsterdam, CDROM, 2 Burman(b), H., Calibration and Orientation of Airborne Image and Laser Scanner Data Using GPS and INS., Phd Dissertation, Royal Institute of Technology, Stockholm, 2. Crombaghs, M.J.E., Brugelmann, R., de Min, E.J., On the Adjustment of Overlapping Strips of Laseraltimeter Height Data, International Archives of Photogrammetry and Remote Sensing, Vol. XXXIII, Part B3, Amsterdam, CDROM,, 2 Kager, H., Kraus, K., Height Discrepancies between Overlapping Laser Scanner Strips, Proceedings of the Optical 3D Measurement Techniques V, Oct 1-4, Vienna, Austria, 13-11, 21 Kilian, J, Haala, N., Englich, M., Capture and evaluation of airborne laser scanner data, International Archives of Photogrammetry and Remote Sensing, Vol. XXI, Part B3, Vienna, Austria, 383-388, 1996. Leica Geosystems, Product Descriptions, http://www.lh-systems.com/products/index.html, Jan 22. Mass, H-G, Least-Squares Matching with Airborne Laserscanning Data in a TIN Structure, International Archives of Photogrammetry and Remote Sensing, Vol. XXXIII, Part B3, Amsterdam, CDROM, 2 Morin(a), K., El-Sheimy, N., A comparison of Airborne Laser Scanning Adjustment Methods., ISPRS WGII/2 Three-Dimensional Mapping from InSAR and LIDAR Workshop Proceedings, Banff, Alberta, Canada, July 11-13, 21. Morin(b), K., El-Sheimy, N., The Effects of Residual Errors in Airborne Laser Scanning Terrain Data on Ortho-Rectified Imagery., Optical 3D Measurement Techniques V Proceedings, Vienna, Oct 1-4, 21. Terrasolid Inc., Home Page, http://www.terrasolid.fi, Jan 22. Vosselman, G., Mass, H-G, Adjustment and Filtering of Raw Laser Altimetry Data, International Archives of Photogrammetry and Remote Sensing, Vol. XXXIII, Part B3, Amsterdam, CDROM, 2. Wehr, A., Lohr, U., Airborne laser scanning - an introduction and overvie, ISPRS Journal of Photogrammetry & Remote Sensing, v54, Elsevier, 68-82, 1999. 12/12 Washington, D.C. USA, April 19-26 22