Page 1 of 2. Power Supply SL POWER ELECTRONICS CORP 6050 KING DRIVE, BLDG A VENTURA CA 93003, USA

Similar documents
UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

File E Project 91SC COMPONENT POWER SUPPLIES INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

UL TEST REPORT AND PROCEDURE

E A54-UL 2012-AUGUST-29 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

UL TEST REPORT AND PROCEDURE

Page 1 of 2. Component - Power Supply SL POWER ELECTRONICS CORP 6050 KING DR. BLDG A VENTURA, CA 93003, USA

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

UL TEST REPORT AND PROCEDURE

DEMKO CERTIFICATE. Certificate No Page 1/3 Date of Issue Certificate Holder. Manufacturer. Production site

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

Page 1 of 2. Component - Power Supply SL POWER ELECTRONICS CORP BLDG A, 6050 KING ST VENTURA CA 93003, USA

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

File E Project 91SC Issued: July 4, 1991 Revised: August 23, 2007 REPORT

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

File E Project 00SC September 27, 2000 REPORT COMPONENT - POWER SUPPLIES, MEDICAL AND DENTAL EQUIPMENT

UL TEST REPORT AND PROCEDURE

CERTIFICATE OF COMPLIANCE

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

C E R T I F I C A T E O F C O M P L I A N C E

File E Vol. 1 Sec. 35 *Page 1 Issued: and Report Revised:

File E Project 93ME39941, Issued: November 29, 1993 New: April 26, 2006 REPORT COMPONENT - POWER SUPPLIES. For Use In

UL TEST REPORT AND PROCEDURE

Underwriters Laboratories (UL LLC) Safety Certification Report

Power Supply SL POWER ELECTRONICS CORP BLDG A, 6050 KING DRIVE VENTURA CA 93003, USA

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

File E Project 11SC May 15, 2012 REPORT COMPONENT DRIVERS FOR LIGHT-EMITTING-DIODE ARRAYS, MODULES AND CONTROLLERS

TEST REPORT IEC Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements

File E Project 98ME March 9, 1998 REPORT

TEST REPORT IEC Safety of household and similar electrical appliances

TEST REPORT IEC or ISO Reference Number Title of the IEC or ISO Standard

File E Project 01ME October 15, 2001 REPORT

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC Medical electrical equipment Part 1: General requirements for basic safety and essential performance

File E Project 89ME November 30, 1989 REPORT COMPONENT - POWER SUPPLY. Vicor Corp. Andover, MA

File E Project 03ME REPORT COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

SPECIFICATION FOR APPROVAL AC/DC ADAPTOR

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

C E R T I F I C A T E O F C O M P L I A N C E

Procedure And/Or Report Material

Electrical Specifications

File E Project 90ME March 12, 1991 REPORT

Safety Standards. Model Number:

Features. Applications and Benefits TRC ELECTRONICS, INC

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Other Aspects: The completed test report includes the following documents: (total page 14)

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Max. Input Power (W) Input Current. (A pk/50%-µs) Dimming Method. 1-10V Isolated DALI

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

File E Project 03ME Issued: March 4, 2004 REPORT COMPONENT - POWER SUPPLIES, SPECIALTY - COMPONENT

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

Applying branch circuit breakers and supplementary protectors in North America

Electrical Specifications

SIMATIC Ident RFID systems Wide-range power supply unit for SIMATIC RF systems Compact Operating Instructions

Safety Standards. Model Number: Unit Weight:

C E R T I F I C A T E O F C O M P L I A N C E

275 Watt Medical Ultra low profile

RTU500 series Data Sheet Power Supply CP-E 24/2.5

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

M E M O R A N D U M I.S.

Safety Standards. Model Number:

D15CC55UNVD K/KS. UNV DALI Dimming LED Driver 1500mA Constant Current Output Class 2, 55W Output DALI Dimming to 1% Performance.

Safety Standards. Model Number:

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Are you ready for Electrical Safety Testing?

Applying branch circuit breakers and supplementary protectors in North America

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Standards Update Notice (SUN) Issued: April 25, 2017

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number:

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

File E Project 12SC February 9, 2013 REPORT. Component - Protectors, Low-voltage Solid-state Overcurrent

Transcription:

Page 1 of 2 US/14113A/UL Power Supply SL POWER ELECTRONICS CORP 6050 KING DRIVE, BLDG A VENTURA CA 93003, USA SL POWER ELECTRONICS CORP. 6050 KING DRIVE, BLDG A VENTURA CA 93003, USA SHENZHEN POWERLD ELECTRONIC TECHNOLOGY CO LTD NO. 4, LIAWAN ROAD NANSHAN DISTRICT SHENZEN, CHINA For Ratings see the second page of this certificate. GECA40-XG, where X is any number from 5 through 24, which represents the output voltage rating and GECA40XG, where X may be the letters A, B, D, or H. The suffix G indicates compliance to RoHS. (RoHS compliance has not been evaluated by UL) The CB Test Report comprises 7 enclosures. The CB Test Certificate and Report were amended on August 14, 2009 to update critical components and enclosures. IEC 60950-1 (2001) First Edition, Additional evaluation to CENELEC Common Modifications also included. See Test Report for National Differences. E135803-A32-CB-2 Issued: 2009 July 27 Amended: 2009 August 14 (Am. 1) Jolanta M. Wroblewska

Page 2 of 2 US/14113A/UL GECA40-XG Input: 100-240 V ac, 1.0 A, 50/60 Hz Output: 7 A or 40 W maximum or see below for standard output models. Rated power is at 45 C Ambient Convection Cooled. GECA40-5G: GECA40-12G: GECA40-15G: GECA40-24G: 5 V dc/7.0 A 12 V dc/3.3 A 15 V dc/2.7 A 24 V dc/1.7 A GECA40XG Input: 100-240 V ac, 1.4 A, 50/60 Hz Output: 45 W maximum total power, see below for output ratings. Rated power is at 45 C Ambient Convection Cooled. GECA40AG: +5 V dc/5.0 A, +12 V dc/2.5 A, -12 V dc/0.5 A GECA40BG: +5 V dc/3.5 A, +12 V dc/2.0 A, -5 V dc/0.3 A GECA40DG: +5 V dc/3.5 A, +24 V dc/1.2 A, -12 V dc/0.3 A GECA40HG: +3.3 V dc/4.0 A, +12 V dc/2.0 A, -12 V dc/0.3 A The CB Test Report comprises 7 enclosures. The CB Test Certificate and Report were amended on August 14, 2009 to update critical components and enclosures. Issued: 2009 July 27 Amended: 2009 August 14 (Am. 1) Jolanta M. Wroblewska

Issue Date: 2009-07-27 Page 1 of 3 Report Reference # E135803-A32-UL-2 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power Supplies for Information Technology Equipment Including Electrical Business Equipment QQGQ2, QQGQ8 Component Recognition Power Supply GECA40-XG, where X is any number from 5 through 24, which represents the output voltage rating and GECA40XG, where X may be the letters A, B, D, or H. The suffix G indicates compliance to RoHS. (RoHS compliance has not been evaluated by UL) GECA40-XG Input: 100-240 V ac, 1.0 A, 50/60 Hz Output: 7 A or 40 W maximum or see below for standard output models. Rated power is at 45 C Ambient Convection Cooled. GECA40-5G GECA40-12G GECA40-15G GECA40-24G 5 V dc/7.0 A 12 V dc/3.3 A 15 V dc/2.7 A 24 V dc/1.7 A GECA40XG Input: 100-240 V ac, 1.4 A, 50/60 Hz Output: 45 W maximum total power, see below for output ratings. Rated power is at 45 C Ambient Convection Cooled. GECA40AG +5 V dc/5.0 A, +12 V dc/2.5 A, -12 V dc/0.5 A GECA40BG +5 V dc/3.5 A, +12 V dc/2.0 A, -5 V dc/0.3 A GECA40DG +5 V dc/3.5 A, +24 V dc/1.2 A, -12 V dc/0.3 A GECA40HG +3.3 V dc/4.0 A, +12 V dc/2.0 A, -12 V dc/0.3 A Standards: UL 60950-1, 1st Edition, 2007-10-31 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology Equipment - Safety - Part 1: General Requirements) Applicant Name and Address: SL POWER ELECTRONICS CORP. 6050 KING DRIVE, BLDG. A VENTURA, CA 93003 Copyright 2009

Issue Date: 2009-07-27 Page 2 of 3 Report Reference # E135803-A32-UL-2 This Report includes the following parts, in addition to this cover page: 1. Specific Technical Criteria 2. Critical Components 3. Enclosures Copyright 2009

Issue Date: 2009-07-27 Page 3 of 3 Report Reference # E135803-A32-UL-2 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. Test Report By: Reviewed By: Edgard Rincand Associate Project Engineer David Feusier Staff Engineer Copyright 2009

Issue Date: 2009-07-27 Page 1 of 7 Report Reference # E135803-A32-UL-2 SPECIFIC TECHNICAL CRITERIA UL 60950-1, First Edition Information technology equipment - Safety- Part 1: General Requirements Report Reference No...: E135803-A32-UL-2 Compiled by...: Edgard Rincand Reviewed by...: David Feusier Date of issue...: 2009-07-27 Standards...: UL 60950-1, 1st Edition, 2007-10-31 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology Equipment - Safety - Part 1: General Requirements) Test procedure...: Component Recognition Non-standard test method...: N/A Test item description...: Power Supply Trademark...: Model and/or type reference...: GECA40-XG, where X is any number from 5 through 24, which represents the output voltage rating and GECA40XG, where X may be the letters A, B, D, or H. The suffix G indicates compliance to RoHS. (RoHS compliance has not been evaluated by UL) Rating(s)...: GECA40-XG Input: 100-240 V ac, 1.0 A, 50/60 Hz Output: 7 A or 40 W maximum or see below for standard output models. Rated power is at 45 C Ambient Convection Cooled. GECA40-5G GECA40-12G GECA40-15G GECA40-24G 5 V dc/7.0 A 12 V dc/3.3 A 15 V dc/2.7 A 24 V dc/1.7 A GECA40XG Input: 100-240 V ac, 1.4 A, 50/60 Hz Output: 45 W maximum total power, see below for output ratings. Rated power is at 45 C Ambient Convection Cooled. GECA40AG +5 V dc/5.0 A, +12 V dc/2.5 A, -12 V dc/0.5 A GECA40BG +5 V dc/3.5 A, +12 V dc/2.0 A,

Issue Date: 2009-07-27 Page 2 of 7 Report Reference # E135803-A32-UL-2-5 V dc/0.3 A GECA40DG +5 V dc/3.5 A, +24 V dc/1.2 A, -12 V dc/0.3 A GECA40HG +3.3 V dc/4.0 A, +12 V dc/2.0 A, -12 V dc/0.3 A Particulars: test item vs. test requirements Equipment mobility...: for building-in Operating condition...: continuous Mains supply tolerance (%)...: +6%, -10% Tested for IT power systems...: Yes (for Norway) IT testing, phase-phase voltage (V)...: 230 V (for Norway) Class of equipment...: Class I (earthed) Mass of equipment (kg)...: 0.5 Protection against ingress of water...: IP X0 Possible test case verdicts: - test case does not apply to the test object...: N / A - test object does meet the requirement...: Pass - test object does not meet the requirement...: Fail (acceptable only if a corresponding, less stringent national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

Issue Date: 2009-07-27 Page 3 of 7 Report Reference # E135803-A32-UL-2 GENERAL PRODUCT INFORMATION: CA1.0 CA1.1 Report Summary N/A CB1.0 CB1.1 Product Description The product covered by this report is a Switching Power Supply intended for building in and for use in information technology equipment. The power supply is constructed of components mounted on a Printed Circuit Board. CC1.0 CC1.1 Model Differences The GECA40-XG models are similar to each other and differ only in secondary circuitry. The GECA40XG models are also similar to each other and differ only in Secondary circuitry. The GECA40-XG and GECA40XG are Class 1 power supplies and are similar in Primary circuitry. Differences between GECA40-XG and GECA40XG are as follows: GECA40-XG models have only one output and the GECA40XG models have three outputs. Component CY5 is provided in all models in the GECA40-XG except GECA40-12G and omitted in the GECA40XG Series. CY3-CY4 (Y1 type capacitor) is provided in the GECA40XG Series, and CY8 (Y1 type capacitor) is provided only in model GECA40-12G in the GECA40-XG Series. CD1.0 CD1.1 Additional Information Testing was conducted at 2311 Statham Parkway, Oxnard, CA 93033 which was the applicant's previous address and UL San Jose, a CBTL. During the course of this investigation the applicant under went an address change as well as a name change from Condor Power to the current SL Power Electronics. Condor Power name may still be used for marketing purposes. The Y- Capacitor AC series manufactured by Pan Overseas, CBTC is more than three years old. According to Publication IECEE02, Clause 6.3.4, Recognizing NCB's may challenge this certificate. This CBTR is a reissue of CBTR Ref. No. E135803-A32-CB-1 with Cert US/10536A/UL to ensure that the CBTR is valid and less than three years old per the procedures of the IECEE CB Scheme (Publication 02, clause 6.3.4). Summary of Testing indicates the testing that was conducted on the original CBTR Ref No. E135803-A32-CB-1 with Cert. US/10536A/UL. CE1.0 CE1.2 Technical Considerations The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 45 C CE1.4 The product is intended for use on the following power systems: IT (for Norway), TN,, CE1.7 The product was investigated to the following additional standards: EN 60950-1:2001 (which includes all European national differences, including those specified in this test report).

Issue Date: 2009-07-27 Page 4 of 7 Report Reference # E135803-A32-UL-2 CE1.12 CE1.14 The following were investigated as part of the protective earthing/bonding: Printed wiring board trace were tested at current = 210 % of input fuse value T 4 A/250 V, IEC 60127-2, Sheet 3. 0.0196 ohm - GECA40-X tested at 8.4 A which is 210 % of fuse value;, 0.0185 ohm - GECA40X tested at 8.4 A which is 210 % of fuse value. The following are available from the Applicant upon request: Specific data sheets for LEDs that are used for indicating purposes and assumed to be inherently Class 1 operating in the 400-700 nm wavelength range. CF1.0 CF1.1 Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by CF1.2 CF1.3 CF1.5 CF1.7 CF1.11 CF1.12 When installed in an end-product, consideration must be given to the following: The following Production-Line tests are conducted for this product: Electric Strength, The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary-SELV: 272 Vrms, 516 Vpk The following secondary output circuits are SELV: All. The following secondary output circuits are at non-hazardous energy levels: All. The power supply terminals and/or connectors are: Not investigated for field wiring The maximum investigated branch circuit rating is: 20 A CF1.13 The investigated Pollution Degree is: 2 CF1.15 CF1.16 CF1.18 CF1.20 CF2.0 CF2.1 CF2.2 Proper bonding to the end-product main protective earthing termination is: Required. An investigation of the protective bonding terminals has: Not been conducted The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation system with the indicated rating greater than Class A (105 C): T1 (Class B) (130 C) The following components require special consideration during end-product Thermal (Heating) tests due to the indicated maximum temperature measurements during component-level testing: C4 and C5 (125 C), T1 (130 C) This component has been judged on the basis of the required spacings in the Standard for Safety of Information Technology Equipment, UL60950-1, First Edition, dated April 1, 2003. The power supply shall be installed in compliance with the enclosure, mounting, spacing, casualty and segregation requirements of the end-use application. The product input and output are isolated from each other by Reinforced insulation. CF2.3 All tests were conducted with an internal UL R/C fuse, rated T4.0 A, 250 V.