Protection relay for secondary distribution

Similar documents
SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

SIA C. Self-powered overcurrent relay USER MANUAL

SIL. Protection relays for primary and secondary distribution

INSTALLATION & COMMISIONING GUIDE

protection & control specialists

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

SIA B Self and Dual powered Overcurrent & Earth Fault Protection Relay USER S MANUAL L

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850

Index POWER T&D. SIA-B (Dual & Self powered) OC&EF Protection for Secondary Distribution with specific transformers... 20

GENERAL CATALOGUE. Equipments. Devices. fanox.com

Protection Relays PHASE & RESIDUAL OVERCURRENT

ISO 9001:2000 SIL A. Overcurrent and Earth-Fault relay USER S MANUAL SER S MANUAL

SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics

ISO 9001:2000 SIL A. Overcurrent and Earth fault relay INSTALLATION GUIDE. Guia_SIL-A_Rev / 48

VIP 40/45 VIP 400/410

Bus Bar Protection Relay B-PRO 4000

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

Feeder protection relay SPAA 121 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

MINER-S Station Controller

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Products Portfolio. Pole mounted Vacuum Recloser

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

RT4F-120V/20A-WAC RECTIFIER

InteliPro. Protection Relay for Parallel Applications. Technical Specification

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

Residual overvoltage relay

Feeder protection relay SPAA 341 C. Product Guide

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

RT4F-48V/50A-WAC RECTIFIER

NPW800R RETROFITTING. Power and Volatge Protection Relay

Feeder Protection Relay REF 610. Product Guide

RT4F-110V/25A RECTIFIER

Specialized in Self Powered Relays PRODUCTS

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

Transformer Protection Relay

For Transmission, Distribution and Machinery protection.

Feeder protection relay

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

SM100. On-Line Switchgear Condition Monitoring

RT4B-110V/12A RECTIFIER

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

iswitch imotor Compact QR

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

RT12-240V/2.4kW Rectifier Specification

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication

Section 4 Ground-Fault Protection Devices

Scout-S Station Controller

Synchro-check relay. Application

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

2C138. Sensitive Earth Fault Relay. Features. Application. Operation

ATS Automatic transfer switches Advanced version

GRD130 - FEATURES APPLICATION

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

SACE Emax 2 Specification guide

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

extending the boundaries of technology evolution of proven technology FEATURES

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SLI 15 INVERTER SERIES, 1500 W

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

CURRENT PROTECTION RELAY SMPR-1

tec P - CK010 Self-Powered

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

750/760 Feeder Management Relay Instruction Manual

Feeder/ Motor Protection Relay VAMP 40

FP-5000 Feeder Protection

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

ACOS 300. Reliable protection for network and constructions in medium- and high voltage

Arc protection relay. Features Three-phase overcurrent function. Application

Protection relays.

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Voltage Transducer UMT516 / MT516

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Comprehensive Modular Genset Controller

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

Transcription:

Protection relay for secondary distribution Dual and Self powered Signalling with flag indicators High electromagnetic compatibility Events recorder and specific test menu

Protection relay for secondary distribution. SIA 4 Protection functions and Standards 5 How to select the SIA relay 6 SIA-C 8 Main specifications 8 Technical specifications 8 Model list SIA-A 2 Main specifications 2 Technical specifications 2 Model list 5 SIA-D 6 Main specifications 6 Technical specifications 6 Model list 9 Common features and technical specifications 20 Accessories 22

Through creativity, attention to customer needs, a wealth of experience, and extensive research, Fanox consistently delivers innovative products with unmatched features and performance. Fanox, as an innovation driver and trendsetter, is establishing itself on the energy market as a powerful manufacturer of numerical protection relays that can be consistently used throughout all applications in the Transmission and D_istribution networks. With the SIA and SIL range operators have their systems firmly and safely under control, and have the basis to implement cost-efficient solutions for all duties in modern, intelligent and smart grids.

Protection relays for secondary distribution. SIA The range of SIA relays is designed to protect the secondary transformer and distribution substations of electrical networks. Features include protection against instantaneous and inverse time overcurrent (for phase and neutral) as well as an external trip support (temperature, pressure, etc.) for certain models. The protection functions can be enabled by using both control panel and the communications link to the SICom progamme. Combining the setting and IEC curves available, allows for precise coordination with other equipment. The outstanding feature of both the SIA-C and SIA-A models is that they are self-powered and function by employing the operating current of the installation. This means that maintenance of transformer and distribution substations is heavily reduced. All batteries, chargers and other external power elements are made redundant. Furthermore a great advantage is that these relays ease commissioning and start-up of installations, and also make it easier to manage the equipment in adverse conditions. All models can be powered from an external battery, guaranteeing total operation of the relay, including trip functions occurring due to external faults. 4

Protection functions and Standards Overcurrent protection Function 50P instantaneous phase overcurrent Function 50N instantaneous neutral overcurrent Function 5P Inverse time phase overcurrent Function 5N Inverse time neutral overcurrent Neutral directional protection Function 67N It uses the residual voltage as the polarisation magnitude and the residual current as the operating variable. If the directional function 67N is not enabled, it behaves as a 50N Function. The operative time starts when the following conditions are met simultaneously: - residual voltage higher than setting - residual current higher than setting - the gap between the residual current and residual voltage is such that the residual current is within the area of the intervention. External trip Function 49T There is a direct trip input, normally associated with a bimetallic contact that is fitted to the power transformer, which serves as a backup for the current functions. In order for it to be a real backup, this input is not related to the protection processors. This means that the processors do not read the input and trip the striker, but the input acts directly on the striker, remaining operational for as long as the equipment is powered. This input is especially protected against electromagnetic noise. Switch disconnector protection using trip blocking Many transformation centres have a disconnector as a break element. As line breakers have a limited opening current, with short-circuit events at high currents the responsibility for opening falls on the fuses, because otherwise, opening the line breaker would mean destroying it. In order to deal with these situations, tripping either in phase or neutral is blocked when the measured current exceeds a preset value. objective is clearing the fault in the least damaging place of the application. IEC Curves 60255-5 Standard curves are used for the protection function 5 phase and neutral: - Normally inverse - Very inverse - Extremely inverse - Definite time Measurements Phase and neutral currents are measured with an accuracy of ±2% over a band of ±20% of rated current and ±4% over the rest of the measurement range. Standards EN 50263 (999) Generic for equipment protection and measurement relays. EN 6000-6-4 (200) Generic for emissions in industrial environments EN 6000-6-2 (200) Generic for immunity in industrial environments. EN 550 and EN 55022 RF emissions, Group, Class A limits. IEC 6000-4-2 Electrostatic discharge immunity, level 3. IEC 6000-4-3 Radiated RF immunity, level 3 IEC 6000-4-4 Electrical fast/burst immunity (EFT), level 4 IEC 6000-4-5 Surge immunity, level 3 IEC 6000-4-6 Conducted RF immunity, level 3 IEC 6000-4-8 and IEC 6000-4-9 Pulsed magnetic field immunity, level 5 IEC 6000-4-0 Damped oscillatory magnetic field, level 5 IEC 6000-4- Voltage dip and short interruption immunity IEC 6000-4-2 and IEC 60255-22- Damped oscillatory RF wave immunity, level 3 Fanox Quality Management System its certified according to standard ISO 900:2008 Logical Trip bus Function 68 Function 68 allows the creation of a coordinated net of equipments installed in different levels of the line which enables the blocking or the tripping and whose 5

How to select the SIA relay Description SIA-C SIA-A SIA-D Functions 50P - 5P 50N 5N - 67N (2 units) - - 49T 68 - Protection of break disconnector by trip blocking - Supply Self powered through operating current - Auxiliary voltage 230 Vac - Auxiliary voltage 0-230 Vac / 90-300 Vdc - Auxiliary voltage 24-48 Vdc - Battery supply (KitCom) (2) Actuation Striker or low power coils - Potential - free contact (for coil trip can use TCM) () - () Current transformers Standard CT /5 o / - Double core CT (CT-DB) - - State and command State and command of the circuit breaker - - Number of openings - - Acumulated amps - - Control and signalling Bistable magnetic indicators 4 configurable potential-free inputs - - 4 configurable potential-free outputs - - Events Real time clock (RTC) - Oscillography - - Communication ModBus RTU protocol RS232 port RS485 port - () TCM adapter can be used to operate the coil (2) SIA-C and SIA-D 2 Vdc, SIA-A 9 Vdc Available in all models Selected according to the model 6

SIA-C SIA-A SIA-D 7

SIA-C DUAL & SELF POWERED OVERCURRENT AND EARTH FAULT PROTECTION RELAY FOR SECONDARY DISTRIBUTION Main characteristics - The SIA-C is a Dual & Self powered overcurrent protection relay using the operating current through three /5 or / standard current transformers fitted on the lines. These transformers are also used to obtain current measurements. The equipment can be occasionally supplied by an external battery. - The events are recorded and a specific test menu is provided. - High electromagnetic compatibility. - The installation and subsequent maintenance of batteries is eliminated. The operating costs of the centre are reduced. - Both in dual powered and self powered modes, the start-up of the relay from 0. times of the nominal current in one phase ensures capacity to trip at low energy levels. - The line opening mechanism is activated either by means of a striker PRT, operated by the energy supplied by the relay itself, or by a coil using the TCM trip adapter in case it is necessary. - There are bistable magnetic indicators which indicate the trip cause, maintaining their position even though the relay loses the supply (flags). - Two different sizes of SIA-C relay available by model list to fulfil all the needs of our customers and make the installation easier. New Technical specifications SIA-C Functions diagram SIA-C Battery 2Vdc 50G/50N 5G/5N 49T* 68* 8

3 CT power supply-measurement CT sensitive neutral Striker Connections diagram SIA-C 2 Vdc OC & EF Protection Dual & Self powered SAFETY GROUND 3 CT power supply-measurement Potential free + TCM 2 Vdc OC & EF Protection Dual & Self powered SAFETY GROUND 9

Technical specifications Technical parameters SIA-C Function 50P Permission: yes/no Operating range: 0.0 to 30 x In (step 0.0) Operating time: 0.02 to 300 s (step 0.0) Activation level 00% Deactivation level 95% Instantaneous deactivation Function 50N Permission: yes/no Operating range: 0.0 to 30 x In (step 0.0) Operating time: 0.02 to 300 s (step 0.0) Activation level 00% Deactivation level 95% Instantaneous deactivation Function 5P Permission: yes/no Operating range: 0.0 to 7 x In (step 0,0) Curves: IEC 60255-5 Operating time: Inverse curve, very inverse curve, extremely inverse curve. Definite time: 0.02 to 300 s (step 0.0 s) Dial: 0.05 to.25 Curve, activation level 20% Curve, deactivation level 00% Definite time, activation level 00% Definite time, deactivation level 95% Instantaneous deactivation Timing accuracy: 5% or 30 ms (greater of both) Function 5N Permission: yes/no Operating range: 0.0 to 7 x In (step 0,0) Curves: IEC 60255-5 Operating time: Inverse curve, very inverse curve, extremely inverse curve. Definite time: 0.02 to 300 s (step 0.0 s) Dial. 0.05 -.25 Dial: 0.05 to.25 Curve, activation level 20% Curve, deactivation level 00% Definite time, activation level 00% Definite time, deactivation level 95% Timing accuracy: 5% or 30 ms (greater of both) Function 49T Trip output Frequency Charging time 0 s 24 Vdc - 576 mj (activation of the striker or low powered coil) Potential free-contact (for coil trip use TCM) 50/60Hz True RMS Current measure Sampling: 6 samples/cycle Accuracy ±2% over band of ±20% of rated current and ±4% over the rest of the range. RS232 port: Modbus RTU Communication RS485 port: Modbus RTU Auxiliary supply 230 Vac ±20 % / 0 Vdc ±20% / 24 Vdc ±20% Battery supply With KITCOM adapter DB9 (2 Vdc) Self power from One phase self-power level: current I > 0. x In Operating temperature: -0 to 70 C Environment Storage temperature: -20 to 80 C Humidity: 95% Transformers Power supply and measurement 3 CT /5 or / Metallic box Panel mounting Mechanical features /3 Rack - 4 U or 3/5 Rack - 4 U IP-54 panel mounted Function 68 (Trip Bus) Blocking permission for 5P, 5P, 50N, 5N Dimensions and cutout SIA-C 89 5. 52 Vertical assembly 77 67 72 0.6 35.2 ø7 9.5 CUTOUT 9.5 35.2 Horizontal assembly 0.25 86.5 85 47.9 ø6 279.5 269.5 5 ø6 77.8 6.8 0.6 CUTOUT 0.6 65 ø6 ø6 3.7 5 3.7 0 290.3

Model list SIA-C TYPE PHASE MEASURE NEUTRAL MEASURE NET FREQUENCY POWER SUPPLY EXTRA FUNCTIONS COMMUNICATIONS INPUTS / OUTPUTS PROCESSOR AND MEMORY LANGUAGE MECHANICS SIA C 50P + 5P + 50N + 5N 5 A 5A 5 A 5A 5 6 50 Hz 60 Hz 0 2 3 0 2 3 2 Vdc + Self power 2 Vdc + Self power + 230 Vac 2 Vdc + Self power + 0 Vac 2 Vdc + Self power + 24 Vdc With striker trip and without direct trip, 49T With striker trip and with direct trip, 49T With potential-free trip and without direct trip, 49T With potential-free trip and with direct trip, 49T 0 Local ModBus (RS 232) Local ModBus (RS 232) and Scada (RS 485) 0 2 Without inputs / outputs Signaling (2 outputs) Function 68 Trip bus (2 inputs & 2 outputs) 0 2 With standard RAM memory With non-volatile RAM memory With non-volatile RAM memory and fast startup A B C English, Spanish and French English, Spanish, French and Turkish English, Spanish, French and Polish A B C D E Vertical assembly, withdrawable with 3 flag indicators Horizontal assembly with flag indicator Horizontal assembly with 3 flag indicators Vertical assembly with flag indicator Vertical assembly with 3 flag indicators Note: Common technical specifications and accessories, page 20.

SIA-A DUAL & SELF POWERED OVERCURRENT AND EARTH FAULT PROTECTION RELAY FOR SECONDARY DISTRIBUTION Main specifications - The SIA-A is a Dual & Self powered overcurrent protection relay using the operating current through specific dual-core current transformers, one used for measuring and the other for powering. - The events are recorded. - High electromagnetic compatibility. - Self power allows for the minimisation of costs for installation and maintenance of the centre as there is no need for batteries or other external power supply items. - SIA-A starts up from 4 A of primary three phase and 0 A of primary single phase with the relay fully operative at this low energy level. - Its reduced depth of 60 mm makes it easy to install. - It includes the switch disconnector protection function by means of trip blocking. - The line opening mechanism is activated by means of a striker PRT operated by the energy supplied by the relay itself. - There are bistable magnetic indicators which indicate the cause of the trip, maintaining their position even though the relay loses the supply (flags). CT-60-00 Highest voltage/insulation rating: 0.72 kv/3 kv Insulation class: Class B, 30 ºC Short-circuit thermal intensity/dynamic: 20 ka - s / 50 ka SIA-E WITH ADDITIONAL FEATURES REGARDING TO SIA-A MODEL Additional specifications - It can be powered up from 5 A of primary single phase current. - It includes 50P and 5N protection functions. - It has Neutral input, getting higher sensibility. - It is provided with Multilanguage menu (English/Spanish/French) and optional Real Time Clock (RTC). - It is available with remote communication through RS-485 port and Modbus RTU protocol. - It has different dimensions. 24.3 8.9 29 CT-35-60 CT-60-00 77.8 6.8 CUTOUT 65 Highest voltage/insulation rating: 0.72 kv/3 kv Insulation class: Class B, 30 ºC Short-circuit thermal intensity/dynamic: 20 ka - s / 50 ka 2

Technical specifications SIA-A Connections diagram SIA-A 3 CT measurement 3 CT power supply <6v <4mj SELF POWER MEASUREMENT KITCOM SIA-A 9 Vdc OC & EF Protection Dual & Self powered 3

Technical specifications SIA-A Functions diagram SIA-A Battery 9 Vdc 49T Technical parameters SIA-A Permission: yes/no Permission: yes/no Function 5P Operating range: 3 to 00A primary (step 0.0) Curves: IEC 60255-5 Operating time: Inverse curve, very inverse curve, extremely inverse curve. Dial: 0.05 to.25 Function 50N Operating range: 0.5 to 20 A primary (step 0.) Operating time: 0.02 to 300 s (step 0.0) Activation level 00% Deactivation level 95% Instantaneous deactivation Curve, activation level 20% Battery supply With KITCOM adapter DB9 (9 Vdc) Curve, deactivation level 00% Instantaneous deactivation Timing accuracy: 5% or 30 ms (greater of both) Self power from current Maximum permanent current 3 phase self-power level I > 4 A (primary) 200 A primary Operating temperature: -0 to 70 C Trip blocking Blocking level: 300 A or 20 x 5P tap (lower of both) Environment Storage temperature: -20 to 80 C Overtemperature trip input Charging time 0 s Humidity: 95% Trip output Frequency Current measure 6 V - 4 mj (activation of the strike) 50/60 Hz True RMS Sampling: 6 samples/cycle Accuracy ±2% over band of ±20% of rated current and ±4% over the rest of the range. Transformers Mechanical features Power supply and measurement. Transformers with double core CT-DB Metallic box Panel mounting 60 x 202 x 60 mm IP-54 panel mounted Communications RS232 port: Modbus RTU Auxiliary Supply 230 Vac ±20 % 4

Model list SIA-A TYPE APPLICATION FREQUENCY EVENTS LANGUAGE POWER SUPPLY ADAPTATION SIA A 50N + 5P + 49T R Switch disconnector 5 6 50 Hz 60 Hz 0 With standard RAM memory (events) With non-volatile RAM memory (events) S E Spanish English 4 Self powered + 230 Vac + 9 Vdc A Note: Common technical specifications and accessories, page 20. Dimensions and cutout pattern SIA-A 6 28 202 28 CUTOUT 203 76 2.2 58.5 70.7 5

SIA-D OVERCURRENT AND EARTH FAULT PROTECTION RELAY FOR SECONDARY DISTRIBUTION Main specifications - The SIA-D is an Overcurrent protection relay with a switched auxiliary power supply (0-230 Vac / 90-300 Vdc or 24-48 Vdc). The current is measured by using /5 or / current transformers. - The events are recorded and a specific test menu is provided. - High electromagnetic compatibility. - Its reduced depth of 75 mm makes it easy to install. - It is ideal for transformation and distribution centres with auxiliary power supplies and/or rechargeable batteries. - It is fitted with two 67N neutral directional units. - With circuit breaker control and monitoring (circuit breaker status, number of openings, accumulated amperes, etc.) - It has 4 inputs and 4 free-potential outputs configuration. - Oscillography is available. Technical specifications 2 Vdc Functions diagram SIA-D 0-230 Vac 90-300 Vdc 24-48 Vdc 50G/50N 5G/5N 68* 6

3 CT measurement CT sensitive neutral neutral voltage Connections diagram SIA-D OC & EF Protection 7

Technical specifications SIA-D Technical parameters Permission: yes/no Permission: yes/no Operating range: 0.0 to 30 x In (step 0.0) Operating range: 0.0 to 30 x In (step 0.0) Function 50P Operating time: 0.02 to 300 s (step 0.0) Activation level 00% Function 50N Operating time: 0.02 to 300 s (step 0.0) Activation level 00% Deactivation level 95% Deactivation level 95% Instantaneous deactivation Instantaneous deactivation Permission: yes/no Permission: yes/no Operating range: 0.0 to 7 x In (step 0.0) Operating range: 0.0 to 7 x In (step 0.0) Curves: IEC 60255-5 Curves: IEC 60255-5 Function 5P Operating time: Inverse curve, very inverse curve, extremely inverse curve. Definite time: 0.02 to 300 s (step 0.0 s) Dial: 0.05 to.25 Curve, activation level 20% Curve, deactivation level 00% Definite time, activation level 00% Definite time, deactivation level 95% Instantaneous deactivation Timing accuracy: 5% or 30 ms (greater of both) Function 5N Operating time: Inverse curve, very inverse curve, extremely inverse curve. Definite time: 0.02 to 300 s (step 0.0 s) Dial: 0.05 to.25 Curve, activation level 20% Curve, deactivation level 00% Definite time, activation level 00% Definite time, deactivation level 95% Instantaneous deactivation Timing accuracy: 5% or 30 ms (greater of both) Function 67N (2 units) Permission: yes/no Operating range Io: 0. to 30 x In (step 0.0) Operating range Vo: 0.4 to 20 V (step 0. V) Operating time: 0.02 to 300 s (step 0.0 s) Directionality: yes/no Current, activation level 00% Current, deactivation level 95% Voltage, activation level 00% Voltage, deactivation level 95% Operating angle: 0 to 359 (step º) Semicone angle: 0 to 70 (step º) RS232 port: Modbus RTU Communications RS485 port: Modbus RTU Conmuted supply 0-230 Vac / 90-300 Vdc, ±20 % Auxiliary supply 24-48 Vdc ±20 % Battery supply With KITCOM adapter DB9 (2 Vdc) Operating temperature: -0 to 70 ºC Environment Storage temperature: -20 to 80 ºC Humidity: 95% Transformers Measurement CT /5 or / Mechanical features Metallic box Panel mounting /2 Rack - 4 U IP-54 panel mounted 4 inputs configurables 4 outputs configurables 0 Vdc ±40 % - 0.5 VA 250Vac - 8A 30Vdc - 5A Trip blocking Blocking level: 7 to 20 x In (step 0.0) Function 52 (Breaker monitoring) Frequency Current measure Oscillography Function 68 (Trip Bus) Alarm, maximum number of openings: to 2000 Alarm, maximum number of acumulated amps: 0 to 999.999 (ka 2 ) 50/60Hz True RMS Sampling: 6 samples/cycle Accuracy ±2% over band of ±20% of rated current and ±4% over the rest of the range. 6 records per cycle The beginning of the oscillography is configurable 2 registers: 3 cycle previous to the fault and 30 after fault Blocking permission for 50P, 5P, 50N, 5N, 67N, 67N2 8

24.3 74.6 77.8 6.8 0.6 3.7 3.7 3 3 290.3 74.2 60 Dimensions and cutout pattern SIA-D ø7 5.7 5.6 CUTOUT 65 Model list SIA-D TYPE 28 PHASE MEASURE NEUTRAL MEASURE HARDWARE SETTINGS POWER SUPPLY EXTRA FUNCTIONS COMMUNICATIONS 202 INPUTS / OUPTUTS EVENTS AND OSCILLOGRAPHY 28 LANGUAGE ADAPTATION 6 203 SIA D 50P + 5P + 50N + 5N + 52 5 5 76 2.2 58.5 70.7 A 5A A 5 A 5 6 7 8 50 Hz + Switch disconnector 50 Hz + Circuit Breaker 60 Hz + Switch disconnector 60 Hz + Circuit Breaker 2 3 0-230 Vac / 90-300 Vdc 24-48 Vdc 0 2 Without 67N With 67N (2 units) With 67NA 0 Local ModBus (RS 232) Local ModBus (RS 232) and Scada (RS 485) 2 4O + 4I 0 2 A B With standard RAM memory With non-volatile RAM memory (events) With non-volatile RAM memory (events + oscillo) English, Spanish and French English, Spanish, French and Turkish A B Standard With Function 68 Trip Bus + USB-Bistables Note: Common technical specifications and accessories, page 20. 9

COMMON FEATURES (SIA-C, SIA-A and SIA-D) HMI The HMI consists of: - A 2x20 LCD screen with alphanumeric characters that allow the equipment parameters to be set (adjusted) and monitored (measurements, statuses, events). - A membrane keyboard with six keys that allow you to navigate the menus and access information of interest. A seventh button RESET, allows you to reset the bistable indicators and the events log. For security reasons, an access code is needed to modify the settings. - LED indicators showing the type of power supply being used at all times. The relay can use more than one power source at one time. - Bistable magnetic indicators that signal the cause of tripping. These indicators remain in position when the equipment loses power, reducing the time the maintenance service needs to identify the cause of tripping. Test Menu This allows you to use the HMI to verify correct operation of the LEDs, the bistable magnetic indicators and the trip contact. Activating the trip contact from the test menu allows you to verify correct operation of the opening mechanism simply. On SIA-D, it is possible to activate the 4 outputs. Events Events are recorded and ordered chronologically (up to 500), allowing you to analyse what has happened with the installation over time (start-ups, tripping power supplies, etc.). They are recorded chronologically to the nearest millisecond in real time, thanks to the Real Time Clock (RTC). Events can be recorded on a non-volatile RAM memory. This option can be selected according to the model. 20

features Communications The relays have a communication local port on the front of the equipment and two rear ports on the back for remote communication. The SICom programme with Windows 2000/XP and Windows 7 uses a graphic user interface to allow you to access all equipment information, modify the settings and save events. The programme can be used locally by using the front port or remotely by using the rear RS485 port. There are 4 levels of access with user-definable codes. Self-diagnosis Diagnostic algorithms to generate the corresponding events are executed on starting up the equipment and all the time the relay is operating 2

Аccesories Battery power supply KitCom The KitCom is an adapter that allows you to feed SIA relays from the front communications port, allowing also to communicate with the computer locally via RS232. The power comes from two AA batteries of.5 Volts placed at the bottom of the device. The equipment has a small Dc / Dc power supply raising the voltage to 2 volts required to operate the equipment. This operation includes the energy necessary to trip. This is important in the commissioning processes of the transformation centres, allowing full verification of the centre, without any auxiliary power supply. The equipment has a microswitch that feeds the power supply with a LED (ON) when the voltage is 2 volts. The Kitcom is also available for SIA-A and SIA-E relays using the model of 9 volts (GLR-6) battery. In addition to all the necessary to give the power supply, this device has two LED associated with the Rx and Tx lines of communication, and they are used to verify that there is data traffic between the PC and the SIA relay. Striker PRT This is a single effect solenoid. The striker is spring operated. The striker is activated by low-power polarised electrical signal supplied by the relay in case of a fault. The striker is reset to its starting position manually. Travel: 8 mm Spring strength: - Start of travel: 37 N - End of travel: 8 N Response time: 4 ms Protection rating: IP-40 Trip adaptor TCM This item is connected to the potential-free trip contact of the relay and supplies the energy needed to trip the coil. It is loaded using the auxiliary voltage supply of the transformation centre and retains power for up to 3 days without external power supply. POWER SUPPLY OUTPUT VOTAGE FOR TRIP COIL ADAPTATION T R I P TCM 2 A B C - A 230 Vac 0 Vac 48 Vdc 0 Vdc 220 Vdc *SIA-C with potential-free contact Available for SIA-A and SIA-E Available for SIA-C* and SIA-D_ 22

SIL Line and Feeder protection relays for primary and secondary distribution Reduced size and light weight Two protocols simultaneously: MODBUS & IEC 60870-5-03 With auto-reclosing, trip circuit supervision and cold load pick up High electromagnetic compatibility SIL-A and SIL-B are designed for the protection of primary and secondary substations in electric distribution networks. Features include protection against overcurrent (SIL-A and SIL-B) and overvoltage and undervoltage (SIL-B). Both models come with the option of reclosing. 23

FANOX is involved in all levels of electrical distribution, both primary and secondary, and has a great deal of experience in designing and producing customized equipment for manufacturers of primary substations with relation to protection control, measurement and communication, and is an important reference within this field. 5 Five year guarantee Parque Tecnológico de Bizkaia Astondo bidea, Edif. 604 4860 D_ERIO (Spain) tel.: (+34) 94 47 4 09 fax.: (+34) 94 47 05 92 mail: fanox@fanox.com www.fanox.com Fanox reserves the right to modify technical specification of products contained within this catalogue without previous notice. 0/202/Rev4