KUUMIC OY DATA TRANSFER FALLBACK SWITCH KU113. Technical Reference

Similar documents
3500/53 Electronic Overspeed Detection System

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

3500/45E Position Monitor

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

SitePORTAL Lite TA-SPL32-R48

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SIU-218 and SIU-2218

Fiber optic converter audio and CAN TA OPERATION MANUAL

Total Reach ISDN/DDS Isolation Card P P30059 Isolation Card

RSTI-EP Slice I/O. Digital Output Module

Process displays For current and voltage

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Easy To Use OEMS Take Note

rdczbk User Manual ZigBee to RS-232 / RS-485 Converter

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Connecting a Cisco Output Module

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

3500/50E Tachometer Module

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

Pepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power

Version 1.0c May 6, 2010 ATK3

IST ULTRASTAB Power Supply for high precision transducers

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

OPERATION MANUAL SMARTLAB USB 8 CHANNELS RELAY OUTPUT 8 CHANNELS PHOTO ISOLATOR INPUT BOARD

DPS Telecom Your Partners in Telecom Management Networks

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

Suprex RS-485 SPX-7500 Wired Reader-Extender

Nicotra Sistemi RTU 2012 REMOTE TEST UNIT KEY FEATURES

APP 700 Technical Specification

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

PB4350DAC1 - D/A Module User s Guide

Model NM512. TS1 Conflict Monitor Standard 12 Channel Unit. Naztec Operations Manual. For. Published by

BA/BS4S Temperature Sensor Installation & Operating Instructions

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

RS232/TTL Modem Interface Data Sheet Product Specifications and Performance

Total Reach ISDN/DDS Isolation Card P VDC to 24VDC External Power Supply P30060 Description & Installation

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

3500/33 16-Channel Relay Module Bently Nevada* Asset Condition Monitoring

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

I/O Expansion Module Installation & Reference

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Overview. Application. Function. Technical specifications. Home

PAC BI-DP BIM and 8701-CA-BI Carrier

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Prisma II Platform. Optoelectronics

SPX-7400_SPX-7410_MAN_161028

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

VersaPoint I/O Module

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PRODUCT SPECIFICATION

USER MANUAL. SATEL i-link. I/O-converter. Version 1.4

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

DS1 Isolation Cards. P Wire Card P Wire Card. Description & Installation

3500/32M 4-Channel Relay Module

M-series Intrinsically Safe I/O

Data Sheet 1SD536F2-MG1200FXF1US53 Single-Channel SCALE Plug-and-Play IGBT Driver

Tu Sitio de Automatización!

IMIO100 IMIO105. DDC controllers. Summary

LGR-5325 Specifications

PRODUCT SPECIFICATION

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

INSTALLATION INSTRUCTIONS

3500/45 Position Monitor

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

PGR-3200 MANUAL INSULATION MONITOR

RS485 MODBUS Module 6RO

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

RS-485 I/O Modules: ADAM-4000

M1600 Parallel Input / Output

Relay Deck Datasheet

M2400 Analog Output. Technical Description. Eiserstraße 5 phone 05246/ Verl fax 05246/ Date : Version : 2.

1. DB-9 interface pins Definition

GT- IRDM-9603 Product description Rev. 2 17/06/2014

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

SBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description

2.5 Solid State Disk. Description. Features. Placement. Dimensions. Transcend Information Inc. 1. Side Millimeters Inches

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

File (19 inches) for RS3 FIC I/Os (AI/AO) migration toward a new system

SPECIFICATION. SFX Form Factor. SST-ST45SF 450W Switching Power Supply Active PFC Circuit Full Range Input. SFX Form Factor

3. APPEARANCE AND CONNECTORS

Industrial Media Converters

Residual overvoltage relay

Masibus Automation And Instrumentation Pvt. Ltd.

VersaMax IP I/O Module

OPERATION MANUAL. Decision Group Inc. SMARTLAB USB 16 CHANNELS RELAY OUTPUT 16 CHANNELS PHOTO ISOLATOR INPUT BOARD

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

RS485 MODBUS Module 8AO

Transcription:

FALLBACK SWITCH Technical Reference

CONTENTS 1. GENERAL...1 1.1. INTRODUCTION...1 1.1.1. Basic functions...1 1.2. TECHNICAL SPECIFICATIONS...3 1.2.1. CONNECTORS...3 1.2.2. LED INDICATORS...5 1.2.3. JUMPERS AND SETTINGS...5 1.2.4. ALARMS...5 1.2.5. POWER SUPPLY...6 1.2.6. MECHANICAL DIMENSIONS...6 1.2.7. ENVIRONMENTAL CONDITIONS...6

1. GENERAL 1.1. INTRODUCTION 1.1.1. Basic functions Primary line Modem Modem Modem Modem A B C SUBSTATION Secondary line Connecting according the respond Fall Back Switch is used to select the functioning communication line for the RTU. The selection criteria is based on the responding frequency of the RTU. FBS switching time must be adjusted to match with the polling period of the RTU. If there is no poll for the RTU and no response, the FBS is chancing the line continuously. Suddenly the RTU receives the good poll and responds, this will satisfy the control logic and make the current selection permanent. If the polling is stopped then the FBS starts to hunt for the good line again. Connecting according the backup line carrier detect If there is no communication the FBS hunts for the good line. The dispatch centre uses the main line for polling and FBS selects that line as the permanent communication line. Dispatch centre changes the communication over the backup line. Backup line carrier detect is connected to the FBS line B. When the carrier detect rise up the FBS line B is selected and it stays selected as long as the carrier detect is on. Dropping the carrier detect line down starts the good line hunting again. 1

PG RTS GND PG RTS GND PG RTS GND A B C RTS MONITOR KUUMIC OY FINLAND FALLBACK SWITCH MODEL: ALARM OFF DELAY A-C B-C OK CH CHANGES TO ALARM 2 3 5 9 SWITCHING TIME POWER SUPPLY 12/24/48VDC ALARMS 1 2 V+ CH V+ V+ V- V- Line A Line C Control logic Line B 2

1.2. TECHNICAL SPECIFICATIONS 1.2.1. CONNECTORS A Communication port A 1 PG - Protective ground 2 Input Received data 3 Output Transmitted data 4 RTS Input/output Request to send 5 - - - 6 GND - Signal ground B Communication port B 1 PG - Protective ground 2 Input Received data 3 Output Transmitted data 4 RTS Input/output Request to send 5 Input Data carrier detect 6 GND - Signal ground C Communication port C (Common line) 1 PG - Protective ground 2 Output Received data 3 Input Transmitted data 4 RTS Input/output Request to send 5 Output Data carrier detect 6 GND - Signal ground 3

MONITOR Data communication monitoring 1 PG - Protective ground 2 Output Received data 3 Output Transmitted data 4 RTS Output Request to send 7 GND - Signal ground 8 Output Data carrier detect POWER SUPPLY 1 + Input Power supply + 2 + Input Power supply + 3 - Input Power supply - 4 - Input Power supply - ALARMS 4 pcs. insulated solid state relay contacts Pin Signal Description 1 1 Alarm 1 2 3 2 Alarm 2 4 5 V+ Power supply alarm 6 7 CH Switch changed alarm 8 4

1.2.2. LED INDICATORS Communication status LEDs are connected to the line C RTS A-C B-C OK CH Received data Transmited data Request to send Data carrier detect Indicates the switch position from Line A to Line C Indicates the switch position from Line B to Line C Indicates the connection is good Indicates the switch position is changed and alarm off delay is on 1.2.3. JUMPERS AND SETTINGS CHANGES TO ALARM ALARM OFF DELAY SWITCHING TIME Is used to configure the number of the switch changes to generate alarm Adjustable delay to set alarm off when connection is good Adjustable time to change switch position when data is lost 1.2.4. ALARMS 1 Alarm is generated when data is lost and switch position has changed specified times 2 Same as alarm 1 V+ Alarm is generated when power supply is off CH Alarm is generated everytime the switch position is changed The alarms are realised on the solid state relays for AC and DC voltages. Max. voltage 350 VDC/VAC peak Max. DC current 100 ma Max. AC current 100 ma Insulation voltage 2000 V Max. on resistance 35 Ω Leak current <10 µa 5

1.2.5. POWER SUPPLY Supply voltage range Power consumption 8-62 VDC 0,75W max. 1.2.6. MECHANICAL DIMENSIONS Width Height Depth (including connectors) Weight 128 mm 110 mm 71 mm 374 g 1.2.7. ENVIRONMENTAL CONDITIONS Operating temperature Storage temperature Relative humidity 0 to 50 C -40 to 85 C 10 to 90 % (noncondensing) 6