NovaScale 5xx5 NOVASCALE. Cabling Guide REFERENCE 86 A1 92ER 03

Similar documents
UNIVERSAL NOVASCALE R421 R422 R422-INF. HOW TO: Install Windows Using a Virtual Media Drive. REFERENCE Rev05v01

WLM Accounting. User s Guide AIX ORDER REFERENCE 86 A2 76EF 00

Integrated Virtualization Manager. ESCALA Power7 REFERENCE 86 A1 41FF 08

Bull. HACMP 4.4 Programming Locking Applications AIX ORDER REFERENCE 86 A2 59KX 02

Bull. Performance Tools Guide and Reference AIX ORDER REFERENCE 86 A2 27EG 01

Live Partition Mobility ESCALA REFERENCE 86 A1 85FA 01

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

QuickSpecs. HP Server Console Switches Overview

ExpressCluster X 2.0 for Linux

NEC EXPRESS5800/R320a-E4 Configuration Guide

Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx

Cisco TEO Adapter Guide for Microsoft System Center Operations Manager 2007

ExpressCluster X 3.2 for Linux

NEC EXPRESS5800/R320b-M4 Configuration Guide

Bull. SNMP Agent for HiSpeed Adapters Administrator & User Guide AIX ORDER REFERENCE 86 A2 73AT 02

Cisco TEO Adapter Guide for

NEC EXPRESS5800/R320a-E4 Configuration Guide

1+1 Console 8/16/32 ports Modularize CAT-5 KVM Switch (Console Free)

The HP Server Console Switch with Virtual Media is backwards compatible with all HP Cat5 based Server Console Switches and interface adapters.

Bull. System Management Concepts Operating System and Devices AIX ORDER REFERENCE 86 A2 28EF 03

QuickSpecs. HP Server Console Switches. HP Server Console Switches

QuickSpecs. What's New New USB interface adapter compatible with CAC and virtual media. HP KVM Server Console Switch G2 with Virtual Media & CAC

NEC EXPRESS5800/R320b-M4 Configuration Guide

DPN-4 Duo. User Manual. 4-Port Dual-Head Displayport KVM switch with USB 2.0 and Audio Sharing

Hitachi Compute Blade Installation Guide for Oracle Linux OS Installation Guide

Cisco TEO Adapter Guide for Microsoft Windows

The HPE Server Console Switch with Virtual Media is backwards compatible with all HPE Cat5 based Server Console Switches and interface adapters.

PRIMECLUSTER GDS Snapshot 4.3A20. Installation Guide. Linux

Cisco TelePresence VCS CE1000 Appliance

Bull ESCALA PL 820R. Installation Guide ORDER REFERENCE 86 A1 19EG 01

ExpressCluster X 3.1 for Linux

Hardware Installation Guide Installation (x3350)

Bull. AIX Communications Programming Concepts AIX ORDER REFERENCE 86 A2 35JX 01

AX3000 Platine Terminal Ethernet TCP/IP

QuickSpecs. HP IP Console Switch with Virtual Media Overview

AX3000 Platine Terminal Ethernet TCP/IP

EXPRESSCLUSTER X 3.3 for Linux

Hitachi Compute Blade Installation Guide for Oracle Solaris OS Installation Guide

Microsoft Windows Server 2008 On Integrity Servers Overview

Host Upgrade Utility User Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

AlterPath KVM/net Plus Installation, Configuration, and User s Guide

Cluster Configuration Design Guide (Linux/PRIMECLUSTER)

ThinkCentre M57e systems offer excellent performance at a competitive price

Copyright 2013 Trend Micro Incorporated. All rights reserved.

CoreBuilder 9000 Enterprise Switch Getting Started Guide.

About This Book. Who Should Use This Book. Highlighting. Case Sensitivity in AIX. iii

AlterPath KVM/net Installation, Configuration, and Users Guide

DPN 4 Duo. User Manual. 4-Port Dual-Head DisplayPort 1.2 KVM Switch with USB 2.0 and Audio Sharing

P3AM ENZ0. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. Operation Guide (Basic)

NEC EXPRESS5800/R320a-E4 Configuration Guide

Videoscape Distribution Suite Software Installation Guide

GB-Ware. Quick Guide. Powered by: Tel: Fax Web:

Veritas NetBackup Appliance Fibre Channel Guide

Copyright 2012 Trend Micro Incorporated. All rights reserved.

Retired. Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

ExpressCluster X 3.0 for Windows

EXPRESSCLUSTER X 4.0 for Linux

DX System Operating Guide

Installation and Configuration Guide for Visual Voic Release 8.5

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

VERITAS NetBackup 6.0 for Microsoft SharePoint Portal Server 2001

NOVASCALE 7000 DPS7000/XTA V7000. Operators' Guide. Hardware: DPS7000/XTA REFERENCE 77 A2 74US 10

Conext EasyConfig Tool

JTDS. DSA Acess from Java (JTDS) 47 A2 98US Rev00

QuickSpecs. HP IP Console Switch G2 with Virtual Media & CAC. Overview

Model A4268A FWD SCSI Adapter Installation and Service Guide. Embedded Systems Operation Part No. A Edition E1097

DKVM-IP1. Before You Begin. Check Your Package Contents. 1 Port KVM Switch Over IP

CONFERENCE 911 USER GUIDE NEC

Cisco Host Upgrade Utility 1.5(1) User Guide

Color imageclass MF8170c Network Guide

AX3000 Platine Terminal Ethernet TCP/IP

ExpressCluster X 1.0 for Linux

IBM System x3850 M2 servers feature hypervisor capability

FUJITSU Server PRIMEQUEST 2000 Series Design Guide

Structure and Overview of Manuals

AX3000 Platine Terminal Ethernet TCP/IP

Optimizing Fusion iomemory on Red Hat Enterprise Linux 6 for Database Performance Acceleration. Sanjay Rao, Principal Software Engineer

IBM. User's Guide and Installation and Service Guide. Supplement to the RS/6000 Enterprise Servers S70 and S7A:

AX3000 Platine Terminal Ethernet TCP/IP


Black Box Tech Support: FREE! Live. 24/7.

SKM-08. USER MANUAL (rev 2.0) 8-Port Keyboard and Mouse Switch with USB 2.0 Sharing

Hitachi Compute Blade 2500 Series

NEC EXPRESS5800/E110d-1 Configuration Guide

HP OmniBook DiagTools. User s Guide

ETERNUS SF Express V15.3/ Storage Cruiser V15.3/ AdvancedCopy Manager V15.3. Migration Guide

DockingStation28May03.qxd 5/28/2003 9:12 PM Page 1 READ FIRST!

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux

Hitachi Compute Blade 500 Series

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation

Extends your KVM from PS/2 or USB servers up to 100 feet (30 m) away.

IBM GCM16 and GCM32 Global Console Managers IBM System x at-a-glance guide

novascale Blade BL465

EXPRESSCLUSTER X SingleServerSafe 3.3 for Linux. Installation Guide. 01/29/2016 4th Edition

System Manager Unit (SMU) Hardware Reference

Areas Covered. PRIMERGY BX620 S2 Server Blade User s Guide

FCC COMPLICANCE STATEMENT

D/ESAM Installation Guide

UHDN 4P Duo. User Manual. 4-Port Dual Head Ultra 4K-60Hz HDMI KVM Switch with USB 2.0 and Audio Support. Manage 4 computers from a single workstation

Transcription:

NovaScale 5xx5 Cabling Guide NOVASCALE REFERENCE 86 A1 92ER 03

BLANK

NOVASCALE NovaScale 5xx5 Cabling Guide Hardware September 2007 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 92ER 03

The following copyright notice protects this book under Copyright laws which prohibit such actions as, but not limited to, copying, distributing, modifying, and making derivative works. Copyright Bull SAS 1992, 2007 Printed in France Suggestions and criticisms concerning the form, content, and presentation of this book are invited. A form is provided at the end of this book for this purpose. To order additional copies of this book or other Bull Technical Publications, you are invited to use the Ordering Form also provided at the end of this book. Trademarks and Acknowledgements We acknowledge the right of proprietors of trademarks mentioned in this book. Intel and Itanium are registered trademarks of Intel Corporation. Windows and Microsoft software are registered trademarks of Microsoft Corporation. UNIX is a registered trademark in the United States of America and other countries licensed exclusively through the Open Group. Linux is a registered trademark of Linus Torvalds. The information in this document is subject to change without notice. Bull will not be liable for errors contained herein, or for incidental or consequential damages in connection with the use of this material.

Preface Table of Contents Intended Readers......................................................... Highlighting............................................................. Related Publications...................................................... vii vii viii Chapter 1. Cabling Diagrams.............................................. 1-1 PAP Unit Data Cabling Diagram............................................ 1-2 Hub Data Cabling Diagram............................................... 1-3 KVM Switch and KVM Extender Data Cabling Diagrams...................... 1-4 KVM Switch........................................................... 1-4 KVM Extender......................................................... 1-5 Fibre Channel Disk and FC Adapter Data Cabling Diagrams................... 1-6 FDA 1x00 FC Direct Connection......................................... 1-6 FDA 2x00 FC Direct Connection......................................... 1-7 FDA 2x00 FC Connection via an FC Switch............................... 1-8 Extension Disk Rack (FDA 1x00 FC - FDA 1x00 FC)........................ 1-9 Extension Disk Rack (FDA 2x00 FC - FDA 1x00 FC)........................ 1-9 FC Switch and FC Adapter Data Cabling Diagram........................... 1-10 Nport Server Data Cabling Diagrams....................................... 1-11 Nport Server Front connection........................................... 1-11 Nport Server Rear Connection........................................... 1-11 XSP Cables.............................................................. 1-12 Side Band Cables........................................................ 1-14 Power Cabling Diagrams.................................................. 1-15 Mono-Module Power Cabling Diagram................................... 1-15 Bi-Module Power Cabling Diagram....................................... 1-16 Tri-Module Power Cabling Diagram...................................... 1-17 Quadri-Module Power Cabling Diagram.................................. 1-19 Index................................................................... X-1 Preface iii

iv Cabling Guide

List of Figures Figure 1. Pap Unit data cabling diagram................................................ 1-2 Figure 2. Hub data cabling diagram.................................................... 1-3 Figure 3. KVM Switch data cabling diagram (tri-module example).......................... 1-4 Figure 4. KVM extender data cabling diagram.......................................... 1-5 Figure 5. FDA 1x00 FC disk rack data cabling diagram (mono-module example)............. 1-6 Figure 6. FDA 2x00 FC disk rack data cabling diagram (bi-module example)................ 1-7 Figure 7. FDA 2x00 FC disk rack data cabling diagram via an FC Switch................... 1-8 Figure 8. FDA 1x00 FC - FDA 1x00 FC extension disk rack data cabling diagram............ 1-9 Figure 9. FDA 2x00 FC - FDA 1x00 FC extension disk rack data cabling diagram............ 1-9 Figure 10. FC Switch data cabling diagram (quadri-module example)........................ 1-10 Figure 11. Nport server data cabling diagram (front view)................................. 1-11 Figure 12. Nport server data cabling diagram (rear view).................................. 1-11 Figure 13. XSP data cabling diagram (bi-module interconnection)............................ 1-12 Figure 14. XSP data cabling diagram (tri / quadri module interconnection).................... 1-13 Figure 15. Side Band data cabling diagram.............................................. 1-14 Figure 16. NovaScale 5085 Server / NovaScale 5085 Partitioned Server power cabling diagram 1-15 Figure 17. NovaScale 5165 SMP Server / NovaScale 5165 Partitioned Server power cabling diagram. 1-16 Figure 18. NovaScale 5245 SMP Server / NovaScale 5245 Partitioned Server power cabling diagram. 1-18 Figure 19. NovaScale 5325 SMP Server / NovaScale 5325 Partitioned Server power cabling diagram. 1-20 Preface v

vi Cabling Guide

Intended Readers This guide is intended for use by qualified personnel in charge of installing, maintaining, servicing, and upgrading Bull NovaScale Servers. NovaScale 5xx5 Server Cabling Diagrams: Data cables, on page 1-2 Power cables, on page 1-15 Highlighting The following highlighting conventions are used in this guide: Bold Italics Identifies predefined commands, subroutines, keywords, files, structures, buttons, labels, and icons. Identifies referenced publications, chapters, sections, figures, and tables. < > Identifies parameters to be supplied by the user. Abbreviations, acronyms and concepts are documented in the Glossary. Preface vii

Related Publications NovaScale 5xx0/6xx0 Servers /NovaScale 5xx5 Servers Site Preparation Guide, 86 A1 87EF explains how to prepare a Data Processing Center for Bull NovaScale Servers, in compliance with the standards in force. This guide is intended for use by all personnel and trade representatives involved in the site preparation process. Bull 1300H/L & 1100H/L Cabinets, 86 A1 91EM explains how to install and fit out rack cabinets for Bull NovaScale Servers and peripheral devices. PAM Help Message Guide, 86 A7 32ER provides the complete collection of PAM Help Messages containing valuable troubleshooting information. Troubleshooting Guide, 86 A7 91EF explains how to diagnose and solve any problems occurring during Bull NovaScale Server operation. This guide is intended for use by qualified support personnel. Praxidiag Diagnostics Guide, 86 A7 33ER provides the complete collection solutions to known problems extracted from the Praxidiag database. Bull NovaScale Series Documentation Overview, 86 A2 27EM describes the hardware, software and online documentation available for Bull NovaScale Servers, related Operating Systems, and licensed programs. NovaScale 5xx0/6xx0 Servers Installation Guide, 86 A1 93EM explains how to set up and start NovaScale 5xx0/6xx0 Servers for the first time. This guide is intended for use by qualified support personnel. User's Guide, 86 A1 94EM explains how to use the NovaScale 5xx0/6xx0 Servers servers. This guide is intended for use by Customer Administrators and Operators. Maintenance and Service Guide, 86 A7 95EM explains how to maintain, service, and upgrade NovaScale 5xx0/6xx0 Servers. This guide is intended for use by qualified support personnel. NovaScale 5xx5 Servers Installation Guide, 86 A1 40EM explains how to set up and start NovaScale 5xx5 Servers for the first time. This guide is intended for use by qualified support personnel. User's Guide, 86 A1 41EM explains how to use the NovaScale 5xx5 Servers. This guide is intended for use by Customer Administrators and Operators. Maintenance and Service Guide, 86 A7 42EM explains how to maintain, service, and upgrade NovaScale 5xx5 Servers. This guide is intended for use by qualified support personnel. viii Cabling Guide

Chapter 1. Cabling Diagrams Data Cables PAP unit, on page 1-2 Hub, on page 1-3 KVM switch and KVM extender, on page 1-4 KVM switch, on page 1-4 KVM extender, on page 1-5 Fibre Channel Disk and FC adapter, on page 1-6 FDA 1x00 FC direct Connection, on page 1-6 FDA 2x00 FC direct connection, on page 1-7 FDA 2x00 FC connection via an FC switch, on page 1-8 FDA 1x00 FC - FDA 1x00 FC extension disk rack, on page 1-9 FDA 2x00 FC - FDA 1x00 FC extension disk rack, on page 1-9 FC switch and FC adapter, on page 1-10 Nport server, on page 1-11 Module interconnection (XSP cables), on page 1-12 Module interconnection (Side Band cables), on page 1-14 Power Cables Mono-module power cables, on page 1-15 bi-module power cables, on page 1-16 Tri-module power cables, on page 1-17 Quadri-module power cables, on page 1-19 NovaScale 5xx5 Servers 1-1

PAP Unit Data Cabling Diagram A: Modem USB B: Telephone network socket D: Enterprise LAN E: PAP unit F (1, 2): IOL (IOC 0, 1) G: KVM Switch J: Hub Mark Cable Type From To 3 Combined PS2/VGA cable G (Port 1) E (VGA/PS2) 4 Combined USB/VGA cable G (Port 2) F1 (Video/USB) 5 Combined USB/VGA cable G (Port 3) F2 (Video/USB) 8 RJ45 - RJ45 Ethernet E (Ethernet) D (Enterprise LAN) 9 RJ11 - RJ11 cable A (Line) B 11 RJ45 - RJ45 Ethernet E (Ethernet) J 12 USB cable A (USB) E (USB) 13 DB9 to DB9 cross cable E (COM 2) F1 (COM2) 14 DB9 to DB9 cross cable E (COM 1) F2 (COM2) Figure 1. Pap Unit data cabling diagram 1-2 Cabling Guide

Hub Data Cabling Diagram A: S/S Disk B: FDA2x00 C (1, 2, 3,4): PMB (module 0, 1,2,3) D: Nport Server E: PAP unit J: Hub F: FC Switch Mark Cable Type From To 10 RJ45 - RJ45 Ethernet RJ45 - RJ45 Ethernet RJ45 - RJ45 Ethernet RJ45 - RJ45 Ethernet C1 C2 C3 C4 11 RJ45 - RJ45 Ethernet E J 12 RJ45 - RJ45 Ethernet FDA 1x00 FC (optional external FC disk) J 13 RJ45 - RJ45 Ethernet FDA 2x00 FC (optional external FC disk) J 14 RJ45 - RJ45 Ethernet Nport server Note: a second Nport server is needed for more than 6 domains configuration 15 RJ45 - RJ45 Ethernet F J Figure 2. Hub data cabling diagram J J J J J NovaScale 5xx5 Servers 1-3

KVM Switch and KVM Extender Data Cabling Diagrams KVM Switch KVM switch, on page 1-4 KVM extender, on page 1-5 E: PAP unit F (1, 2): IOL (IOC 0, 1) Module 0 F (3, 4): IOL (IOC 0, 1) Module 1 F (5, 6): IOL (IOC 0, 1) Module 2 G: KVM Switch H KVM Drawer Note: If the KVM is not in the rack, the KVM switch is connected to the KVM via a KVM extender as shown in figure 4. Mark Cable Type From To 1 VGA/PS2/PS2 cable G H 3 Combined PS2/VGA cable G (Port 1) E (VGA/PS2) 4 Combined USB/VGA cable G (Port 2) F1 (Video/USB) 5 Combined USB/VGA cable G (Port 3) F2 (Video/USB) 6 Combined USB/VGA cable G (Port 4) F3 (Video/USB) 7 Combined USB/VGA cable G (Port 5) F4 (Video/USB) 8 Combined USB/VGA cable G (Port 6) F5 (Video/USB) 9 Combined USB/VGA cable G (Port 7) F6 (Video/USB) Figure 3. KVM Switch data cabling diagram (tri-module example) 1-4 Cabling Guide

KVM Extender A: KVM Switch B: KVM extender (local unit) C: KVM extender (remote unit) D: USB or PS2 mouse E: USB or PS2 keyboard F: Monitor Mark Cable Type From To 1 Combined PS2/VGA cable A B 2 RJ45 - RJ45 cable B C 3 USB or PS2 mouse cable D C 4 USB or PS2 keyboard cable E C 5 VGA cable F C Figure 4. KVM extender data cabling diagram NovaScale 5xx5 Servers 1-5

Fibre Channel Disk and FC Adapter Data Cabling Diagrams FDA 1x00 FC Direct Connection FDA 1x00 FC direct Connection, on page 1-6 FDA 2x00 FC direct connection, on page 1-7 FDA 2x00 FC connection via an FC switch, on page 1-8 FDA 1x00 FC - FDA 1x00 FC extension disk rack, on page 1-9 FDA 2x00 FC - FDA 1x00 FC extension disk rack, on page 1-9 A: S/S Disk B: Hub C: PAP unit D, E: FC Adapters Mark Cable Type From To 1 RJ45 - RJ45 Ethernet cable B (port 7) C 2 LC-LC cable A (CTL 0) D (IOC 0) 3 LC-LC cable A (CTL 1) E (IOC 1) 6 RJ45 - RJ45 Ethernet cable A B (port 6) 8* DB9 to DB9 serial cable * C (COM 1) A (RS232) * optional cable used to configure the S/S disk. Figure 5. FDA 1x00 FC disk rack data cabling diagram (mono-module example) 1-6 Cabling Guide

FDA 2x00 FC Direct Connection A: S/S Disk B: Hub C, D, E, F: FC Adapter G: PAP unit Mark Cable Type From To 2 LC-LC cable A (CTL0-HF0) C (IOC 0 Module 0) 3 LC-LC cable A (CTL0-HF1) D (IOC 1 Module 0) 4 LC-LC cable A (CTL1-HF0) E (IOC 0 Module 1) 5 LC-LC cable A (CTL1-HF1) F (IOC 1 Module 1) 6 RJ45 - RJ45 Ethernet cable A B (port 6) 8 * DB9 to DB9 serial cable A (RS232) G (COM 1) * optional cable used to configure the S/S disk. Figure 6. FDA 2x00 FC disk rack data cabling diagram (bi-module example) NovaScale 5xx5 Servers 1-7

FDA 2x00 FC Connection via an FC Switch A: S/S Disk B: Hub C: FC Switch Mark Cable Type From To 1 RJ45 - RJ45 Ethernet cable A B (port 6) 2 LC-LC cable A (CTL0-HF0) C (Port 16) 3 LC-LC cable A (CTL0-HF1) C (Port 15) 4 LC-LC cable A (CTL1-HF0) C (Port 14) 5 LC-LC cable A (CTL1-HF1) C (Port 13) 8 * DB9 to DB9 serial cable A (RS232) G (COM 1) * optional cable used to configure the S/S disk. Figure 7. FDA 2x00 FC disk rack data cabling diagram via an FC Switch 1-8 Cabling Guide

Extension Disk Rack (FDA 1x00 FC - FDA 1x00 FC) A: S/S Disk B: S/S Disk Extension Mark Cable Type From To 1 HSSDC-HSSDC cable A B 2 DE diagnosis cable A B Figure 8. FDA 1x00 FC - FDA 1x00 FC extension disk rack data cabling diagram Extension Disk Rack (FDA 2x00 FC - FDA 1x00 FC) A: S/S Disk FDA 2x00 FC B: S/S Disk FDA 1x00 FC (extension) Mark Cable Type From To 1 HSSDC-HSSDC cable A B 2 DE diagnosis cable A B Figure 9. FDA 2x00 FC - FDA 1x00 FC extension disk rack data cabling diagram NovaScale 5xx5 Servers 1-9

FC Switch and FC Adapter Data Cabling Diagram A: S/S Disk B: Hub C: FC Switch D, E, F, G, H, I, J, K: FC Adapter Mark Cable Type From To 2 LC-LC cable A (CTL0-HF0) C (Port 16) 3 LC-LC cable A (CTL0-HF1) C (Port 15) 4 LC-LC cable A (CTL1-HF0) C (Port 14) 5 LC-LC cable A (CTL1-HF1) C (Port 13) 6 LC-LC cable D (IOC 0 Module 0) C (Port 12) 7 LC-LC cable D (IOC 1 Module 0) C (Port 11) 8 LC-LC cable D (IOC 0 Module 1) C (Port 10) 9 LC-LC cable D (IOC 1 Module 1) C (Port 9) 10 LC-LC cable D (IOC 0 Module 2) C (Port 8) 11 LC-LC cable D (IOC 1 Module 2) C (Port 7) 12 LC-LC cable D (IOC 0 Module 3) C (Port 6) 13 LC-LC cable D (IOC 1 Module 3) C (Port 5) 14 RJ45 - RJ45 Ethernet cable C B (port 7) 15 * DB9 to DB9 serial cable A (RS232) C (COM 1) * optional cable used to configure the S/S disk. Figure 10. FC Switch data cabling diagram (quadri-module example) 1-10 Cabling Guide

Nport Server Data Cabling Diagrams Nport Server Front connection A: Nport server (front view) F1, F2, F3, F4: IOL Mark Cable Type From To 1, 2, 3, 4 DB9 to DB9 cross cable A Note: a second Nport server is needed for more than 6 domains configuration Figure 11. Nport server data cabling diagram (front view) Nport Server Rear Connection F1, F2, F3, F4 (COM2) A: Nport server (rear view) B: Hub Mark Cable Type From To 1 RJ45 - RJ45 Ethernet cable A B (port 7) Figure 12. Nport server data cabling diagram (rear view) NovaScale 5xx5 Servers 1-11

XSP Cables Bi-module Configuration Module 1 MSX 0 MSX 1 B D XSP 1 XSP 1 A XSP 0 C XSP 0 B D XSP 1 A XSP 1 C XSP 0 XSP 0 MSX 0 MSX 1 Module 0 Mark Cable Type From To A XSP cable Module 0 (MSX 0 XSP 0) Module 1 (MSX 0 XSP 0) B XSP cable Module 0 (MSX 0 XSP 1) Module 1 (MSX 0 XSP 1) C XSP cable Module 0 (MSX 1 XSP 0) Module 1 (MSX 1 XSP 0) D XSP cable Module 0 (MSX 1 XSP 1) Module 1 (MSX 1 XSP 1) Figure 13. XSP data cabling diagram (bi-module interconnection) 1-12 Cabling Guide

Tri/Quadri-module Configuration Module 3 Module 2 Module 1 Module 0 Figure 14. XSP data cabling diagram (tri / quadri module interconnection) NovaScale 5xx5 Servers 1-13

Side Band Cables Error and reset signal cables connected to MIOR. Module 3 sb0 sb1 Module 2 Module 2 sb0 sb1 sb0 sb1 Module 1 Module 1 sb0 sb1 sb0 sb1 sb0 sb1 Module 0 Module 0 sb0 sb1 sb0 sb1 sb0 sb1 Bi-Module Tri-Module Quadri-Module Figure 15. Side Band data cabling diagram 1-14 Cabling Guide

Power Cabling Diagrams Mono-Module Power Cabling Diagram All power supply cables are connected to the internal PDU(s), as shown below: Internal Disk configuration Module PAP unit Console KVM switch External FC Disk configuration Module PAP unit Console KVM switch Hub FC Disk Figure 16. NovaScale 5085 Server / NovaScale 5085 Partitioned Server power cabling diagram NovaScale 5xx5 Servers 1-15

Bi-Module Power Cabling Diagram Internal Disk configuration Module x 2 PAP unit Console KVM switch Hub Nport server External Disk configuration Module x 2 PAP unit Console KVM switch Hub Nport server FC Disk Figure 17. NovaScale 5165 SMP Server / NovaScale 5165 Partitioned Server power cabling diagram 1-16 Cabling Guide

Tri-Module Power Cabling Diagram Internal Disk configuration (Main Cabinet) Module x 3 PAP unit KVM switch Hub Nport server KVM extender (local) NovaScale 5xx5 Servers 1-17

External Disk configuration (Main Cabinet) Module x 2 PAP unit KVM switch Hub Nport server KVM extender (local) FC Disk FC switch Internal or External Disk configuration (I/O Cabinet) Console KVM extender (remote) Figure 18. NovaScale 5245 SMP Server / NovaScale 5245 Partitioned Server power cabling diagram 1-18 Cabling Guide

Quadri-Module Power Cabling Diagram Internal Disk configuration (Main Cabinet) Module x 4 PAP unit KVM switch x 2 Hub Nport server x 2 KVM extender (local) Internal Disk configuration (I/O Cabinet) Console KVM extender (remote) NovaScale 5xx5 Servers 1-19

External Disk configuration (Main Cabinet) Module x 4 PAP unit KVM switch x 2 Hub Nport server x 2 KVM extender (local) External Disk configuration (I/O Cabinet) Console KVM extender (remote) FC Disk FC switch Figure 19. NovaScale 5325 SMP Server / NovaScale 5325 Partitioned Server power cabling diagram 1-20 Cabling Guide

Index B Bi-Module Server, power supply cables, 1-16 C Cable FDA 2x00 FC disk rack, 1-8 side band, 1-14 XSP, 1-12 Cables FC (fibre channel), 1-6 FC switch, 1-10 FDA 1x00 FC disk rack, 1-6 FDA 1x00 FC extension disk rack, 1-9 FDA 2x00 FC disk rack, 1-7 FDA 2x00 FC extension disk rack, 1-9 Hub, 1-3 KVM extender, 1-5 KVM switch, 1-4 Nport server, 1-11 PAP unit, 1-2 D Documentation, preface, i F FC Switch, cabling, 1-10 FDA 1x00 FC Disk rack, data cables, 1-6 FDA 1x00 FC extension Disk rack, data cables, 1-9 FDA 2x00 FC Disk rack cabling, 1-8 data cables, 1-7 FDA 2x00 FC extension Disk rack, data cables, 1-9 Fibre Channel Disk rack, data cables, 1-6 H Hub, Data cables, 1-3 K KVM Extender, data cables, 1-5 KVM Switch, data cables, 1-4 M Mono-Module Server, power supply cables, 1-15 N Nport Server, cabling, 1-11 O Overview, documentation, i P PAP Unit, data cables, 1-2 Power supply cables bi-module server, 1-16 mono-module server, 1-15 quadri-module server, 1-19 server, 1-15 tri-module server, 1-17 Q Quadri-Module Server, power supply cables, 1-19 S Side Band, Data cables, 1-14 T Tri-Module Server, power supply cables, 1-17 X XSP, Data cables, 1-12 Index X-1

X-2 Cabling Guide

Technical publication remarks form Title : NOVASCALE NovaScale 5xx5 Cabling Guide Reference: 86 A1 92ER 03 Date: September 2007 ERRORS IN PUBLICATION SUGGESTIONS FOR IMPROVEMENT TO PUBLICATION Your comments will be promptly investigated by qualified technical personnel and action will be taken as required. If you require a written reply, please include your complete mailing address below. NAME : Date : COMPANY : ADDRESS : Please give this technical publication remarks form to your BULL representative or mail to: Bull - Documentation D ept. 1 Rue de Provence BP 208 38432 ECHIROLLES CEDEX FRANCE info@frec.bull.fr

Technical publications ordering form To order additional publications, please fill in a copy of this form and send it via mail to: BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDEX 01 FRANCE Phone: +33 (0) 2 41 73 72 66 FAX: +33 (0) 2 41 73 70 66 E-Mail: srv.duplicopy@bull.net Reference Designation Qty _ [ ] _ [ ] _ [ ] _ [ ] _ [ ] _ [ ] _ [ ] _ [ ] _ [ ] _ [ ] _ [ ] _ [ ] [ ] : The latest revision will be provided if no revision number is given. NAME: Date: COMPANY: ADDRESS: PHONE: FAX: E-MAIL: For Bull Subsidiaries: Identification: For Bull Affiliated Customers: Customer Code: For Bull Internal Customers: Budgetary Section: For Others: Please ask your Bull representative.

BLANK

BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 92ER 03

Utiliser les marques de découpe pour obtenir les étiquettes. Use the cut marks to get the labels. NOVASCALE NovaScale 5xx5 Cabling Guide 86 A1 92ER 03 NOVASCALE NovaScale 5xx5 Cabling Guide 86 A1 92ER 03 NOVASCALE NovaScale 5xx5 Cabling Guide 86 A1 92ER 03