Technical Bulletin, HT/HM HART Module

Similar documents
AW Flow Meters HART Summary for RT-Ex15

DELTA CONTROLS CORPORATION

Dissolved Oxygen (DO) Transmitter SMARTPro HART Command Specification

Technical Bulletin, Recalculating a Previous Batch within the Flow Computer

Technical Bulletin, Upgrading Flow Computer Firmware

DELTA CONTROLS CORPORATION

OMNI Flow Computers, Inc. Last Updated: 19-June-2009 OMNI CPU Rev B

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

GE Fanuc IC695ALG708. Rx3i PacSystem

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

HART Protocol User Manual Rev. 1.0 December, 2014

Oldham OLCT 200 Revision 1

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

HART Applications SEC-5000 Gas Detector

ControlWave Micro HART / BTI Interface Module

HART Field Device Specification PR 5437 Device Revision 2

PAC BI-DP BIM and 8701-CA-BI Carrier

HART. Actuator Control. Redefining Flow Control

HART 7.x Field Device Specification for Honeywell SLG 700 SmartLine Level Transmitter 34-SL Rev 6.0 December 2017

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

VOLUME 1 SYSTEM ARCHITECTURE AND INSTALLATION

MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification

Docking Stations DS-U1, DS-U2, DS-U4, DS-U4-WL and DS-U Adjustment and configuration procedure for the analog inputs

HART 7.x Field Device Specification for STT700 SmartLine Temperature Transmitters Document Number: 34-TT Revision: 1.0 Release: June 2017

HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation

The following steps will allow you to install and quickly begin using DevCom:

AE25-DPP OPERATION INSTRUCTIONS

HART 7.x Field Device Specification for Honeywell ST 800 Smart Pressure Transmitters Document Number: 34-ST Revision: 1.

The following steps will allow you to install and quickly begin using DevCom:

HRM-0800 Instruction Manual

HART Field Device Specification Fisher FIELDVUE DVC6200 SIS Digital Valve

Modem-16 Module. User Manual. Part Number L1

The Omega product you have just received is of the highest quality available, offering superior performance, reliability and value to the user.

Transmitter Cond 7100 e /2 (X)H

Transducers & Transmitters HART USERS MANUAL. GP:50 New York LTD Long Road Grand Island, NY USA

Advanced Test Equipment Rentals ATEC (2832)

Modbus Communications Board

HART Field Device Specification Fisher FIELDVUE DVC5000 Digital Valve Controllers

Mettler-Toledo Smart Communications Protocol Revison 1.0: June 9, 2004 Cond Ind 7100/2(X)H Command Specification Page: 1 of 16

Chipset Evaluation and Development Loadboard Version 2

HART Field Device Specification Fisher FIELDVUE DVC2000 Digital Valve

Model Ultima OPIR-5. Infrared Open Path Gas Detector HART Field Device Specification. Instruction Manual

Modbus Communications Board

RS485 S-Protocol Communications Supplemental Manual for Brooks GF40/GF80 Series Mass Flow Controllers and Meters

ControlWave Micro HART / BTI Interface Module

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

Dynamic Flow Computers, Inc Southwest Freeway, Suite 320 Stafford, TX Ph: (281) Fax: (281)

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

Advanced Test Equipment Rentals ATEC (2832)

HART INTERFACE PROGRAMS. User Manual

Operating Instructions and Description of Instrument Function Prothermo NMT539

Analog Input, 16-Bit Thermocouple Module

WirelessHART Toxic & Combustible Gas Detector P/N: TCD50H1A

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

GFK-2372L September 2015

DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

LCD Meter for Model 3051 Pressure Transmitters English Rev. AA

Model 3005 Analog Board. User s Guide

T E C H N O T E. Peer-to-Peer Communication with WirelessHART. HCF_LIT-129, Revision 1.0. Abstract:

PC CONFIGURATOR Model: 27HUCFG. Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

Quick Start Installation Guide

InLinK HM Setup Software Installation & Operation Manual

KROHNE H250 SN /01-03 MC H250/RR/M9/K2/ESK-Z C K F CIV MD C2H50H D 0.93 kg/l V 2.5 mpa.s T 23.5 C P 0.

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

Honeywell HC-900 with Acromag 967EN Modbus/TCP Module as Remote I/O

CT: Conductivity-Temperature

HART/ MODBUS Gateway HTM-611. User Manual REV

HART Actuator Field Unit Technical Manual Modular Design Electric Valve Actuators

QTS-CLX-APACS APACS IOBUS Module. User Manual

HART Field Device Specification Fisher FIELDVUE DVC6000 and DVC6200 HW1 Digital Valve Controllers

PrimaX IR. HART Specification

HART Field Device Specification: CiDRA SONARtrac

IC695ALG608, IC695ALG616

Low Voltage Probe, LVP-1 (#30019)

Helios PD Large Display Meter Quick Start Guide

Smart Wireless THUM Adapter

LC-110/H. Reference Manual

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

mbc082 Bus Converter

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

QUICK START. DevCom2000 User Manual

Mini4 Data Mux User s Manual. ( xxx) And. Troubleshooting Guide

Rev Cutler-Hammer Smart Breaker Panel Control Manual

Plus-X 300. Installation and Operation Manual

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

Master-Touch INSTRUCTION MANUAL. Series 9000MP Multipoint System Series 9600MP System Control Panel Thermal Gas Mass Flowmeters. version 7.

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

Kurz Instruments, Inc. MFT B-Series

Prizm Mux Monitor (PMon) User Manual. March 13, Rev. 2.1

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

HART 710. User s Manual Version HART-710 User Manual (Version 1.00, July/2010) PAGE: 1

Dash HF Family High Speed Data Acquisition Recorder

Intrinsically Safe Temperature Concentrator System

1791 Analog Block I/O Input/Output Modules User Manual

Transcription:

Last Updated: 04-January-2012 TB-090003B Technical Bulletin, 68-6207 HT/HM Module OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land, Texas 77478 United States of America Phone-281.240.6161 Fax: 281.240.6162 www.omniflow.com 52-0000-0019/Rev B Page 1 of 12

NOTE: User Manual Reference - This Technical Bulletin complements the information contained in Volume 1, System Architecture and Installation for all firmware revisions. Table of Contents Scope...3 Abstract...3 Features and Specifications...3 Installation...3 Terminal Connections...5 Diagnostics...6 Connecting Transmitters...6 I/O Point Assignments ( inputs)...8 I/O Point Assignments (Analog outputs)...8 Configuration...9 Transmitter Configuration...9 OMNI Input Configuration...9 OMNI Input Status Display...10 Alarms and Error Messages...11 Calibration...11 Figures Figure 1. HT or HM Label Rev B...4 Figure 2. HT or HM Label Rev C and Later...5 Figure 3. Connection using Internal Load Resistor...6 Figure 4. Connection using External Load Resistor...6 Figure 5. Multi-Drop...7 Figure 6. Connection using IS Barrier and Internal Load...7 Figure 7. MTL5042, Internal Load...7 Figure 8. Input Status Display...11 52-0000-0019/Rev B Page 2 of 12

Scope This Technical Bulletin applies to all Revisions of the OMNI 6000/3000 Flow Computer running the following application firmware and OMNICOM Version: 20.75.01 and Higher with OMNICOM V1.42 and higher 22.75.02 and Higher with OMNICOM V1.43 and higher 23.75.01 and Higher with OMNICOM V1.44 and higher 24.75.01 and Higher with OMNICOM V1.42 and higher 26.75.03 and Higher with OMNICOM V1.40 and higher 27.75.04 and Higher with OMNICOM V1.41 and higher The application firmware applies to OMNI 3000/6000 Flow Computers equipped with the 68-6201 CPU board only. NOTE: Always install and run the latest copy of OMNICOM. Abstract OMNI Flow Computers manufactures an I/O Module and supporting firmware for the OMNI 3000/6000 Flow Computer that implement the Protocol. The model number for the module is: Features and Specifications The 68-6207 HT/HM Module provides the following: Four (4) independent FSK networks Two (2) 4-20 ma Analog Outputs Maximum of four (4) modules per OMNI 3000/6000 Point-to-point transmitter connections use the (HT) option Multi-drop and multivariable transmitter connections use the (HM) option Four (4) devices per network in Multi-drop mode. The module is shipped as one (1) of two (2) optional types, a 68-6207-HT or a 68-6207-HM. The HT option is for use in point-to-point systems, while the HM option can be used in point-to-point, multi-drop, or multivariable mode systems. The type of the module is programmed at the factory and cannot be changed in the field. It is indicated by an HT or HM label as shown in Figures 1 and 2. There can be a maximum of six (6) installed 68-6207 Modules per OMNI 3000/6000 and these can be any combination of HT or HM modules. Each module must be configured for a unique address between one (1) and six (6) using jumpers on the module. The 68-6207 module and flow computer firmware support Protocol Revision 5 and above. Supported devices include: temperature, pressure and differential pressure transmitters. Installation The Module can be installed in any I/O slot but it is recommended that it be placed after other combo module types(s) installed in the chassis. Each module installed in the chassis must be configured for a unique address using the module address jumpers. It is recommended that HT modules be addressed first followed by any HM modules. Loop power must be provided externally using the OMNI 24 VDC terminals or an additional power supply. Loop load resistors are provided on the module for convenience and can be selected as being OUT of circuit, 250 ohms, or 500 ohms. When in the OUT position, a load resistor from 250 ohms to 600 ohms must be provided externally. 52-0000-0019/Rev B Page 3 of 12

Figure 1. HT or HM Label Rev B 52-0000-0019/Rev B Page 4 of 12

Figure 2. HT or HM Label Rev C and Later Terminal Connections Table 1. Terminal Assignments 68-6207 Terminal Assignments Terminal Assignment 1 Net 1+ 2 Net 1-3 Net 2+ 4 Net 2-5 Net 3+ 6 Net 3-7 Net 4+ 8 Net 4-9 Return (DC-) for Analog Out 1 &2 10 Return (DC-) for Analog Out 1 &2 11 Analog Out 1 12 Analog Out 2 52-0000-0019/Rev B Page 5 of 12

Diagnostics Each Network is provided with four (4) LEDs to help diagnose communication problems. They indicate the communication traffic on each network (Figures 1 and 2). RTS TX CD RX This red LED indicates that the FSK carrier has been turned on and that the flow computer is attempting to send a message to the network. This red LED indicates that data is being sent to the network. This green LED indicates that an FSK carrier that satisfies the minimum level of the standard has been detected on the network. This may be generated by a transmitter and/or a handheld communicator attached to the network. This green LED indicates that data is being received and is being transferred to the flow computer. This may be a response transmission from a transmitter or a handheld communicator if one is being used. Connecting Transmitters Transmitters can be connected using the internal load resistor or an external load resistor. Multiple transmitters are wired in parallel in multi-drop mode (Figures 3 thru 7) +24VDC OMNI 68-6207 INTERFACE BOARD NET + 250 Ohm or 500 Ohm JUMPER NET -. DC RETURN Figure 3. Connection using Internal Load Resistor +24VDC OMNI 68-6207 INTERFACE BOARD NET + JUMPER OUT NET - 250 Ohm to 600 Ohm DC RETURN Figure 4. Connection using External Load Resistor 52-0000-0019/Rev B Page 6 of 12

+24VDC OMNI 68-6207 INTERFACE BOARD NET + 250 Ohm or 500 Ohm JUMPER NET - DC RETURN Figure 5. Multi-Drop SAFE AREA HAZARDOUS AREA I.S. BARRIER OMNI 68-6207 INTERFACE BOARD +24VDC NET + 1 2 MTL 7787+ 3 4 250 Ohm or 500 Ohm JUMPER NET - DC RETURN Figure 6. Connection using IS Barrier and Internal Load SAFE AREA HAZARDOUS AREA OMNI 68-6207 INTERFACE BOARD +24VDC I.S. BARRIER 250 Ohm or 500 Ohm NET + 14 12 11 13 MTL 5042 5 4 2 1 JUMPER NET - DC RETURN HANDHELD COMMUNICATOR Figure 7. MTL5042, Internal Load 52-0000-0019/Rev B Page 7 of 12

I/O Point Assignments ( inputs) The OMNI 3000/6000 Flow Computer provides a set of 64 device I/O point assignments that range from 25 88. Each HT module is allocated four (4) I/O point assignments (one for each of the available networks). These are allocated before any HM module I/O point assignments. HT module I/O point assignments always start with input 25 and are assigned sequentially thereafter. I/O points of multiple HT modules are assigned in ascending order of their configured hardware addresses (i.e. HT-1, HT-2, HT-3 and finally HT-4). Each installed HM module is allocated sixteen (16) I/O point assignments. These are assigned after all HT module I/O assignments have been made. To accommodate up to four (4) multi-dropped devices on each HM network, four (4) I/O point assignments are allocated to each network. I/O points are assigned sequentially, starting with the first available assignment after the HT module assignments. I/O points for multiple HM modules are assigned in sequential order of their configured hardware addresses (i.e. HM-1, HM-2, HM-3 and finally HM-4) In a system with a mix of HT and HM modules, it is recommended that the hardware address be set for all HT modules then for HM modules (i.e. lower numbered addresses for the HT modules). Reference the following examples for how I/O point assignments are made. OMNICOM may be utilized in offline mode to demonstrate how I/O points are assigned with various module installation configurations. Select a desired module installation configuration on the OMNI I/O Modules property page of the configure tree within the left pane. I/O point assignments are shown both in the I/O Allocations groupbox of the same page and the various OMNI I/O Process I/O property pages for each configured module. Example 1 One (1) HT module and one (1) HM module are installed in a system. The HT module address is set to one (1) and the HM module address is set to two (2). The I/O point assignments will be as follows. o o HT-1: I/O points assigned, 25, 26, 27 and 28 (one (1) I/O point assigned per network channel) HM-2: I/O points assigned, 29 32 (network channel 1), I/O assignments 33 36 (network channel 2), I/O assignments 37 40 (network channel 3), I/O assignments 41 44 (network channel 4) Example 2 Two (2) HT modules and two (2) HM modules are installed in a system. The HT module addresses are set to one (1) and two (2). The HM module addresses are set to three (3) and four (4). The I/O points will be assigned as follows. o HT-1: I/O points assigned, 25, 26, 27 and 28 (one I/O point assigned per network channel) o HT-2: I/O points assigned, 29, 30, 31 and 32 (one I/O point assigned per network channel) o HM-3: I/O points assigned 33 36 (network channel 1), I/O assignments 37 40 (network channel 2), I/O assignments 41 44 (network channel 3), I/O assignments 45 48 (network channel 4) o HM-4: I/O points assigned 49 52 (network channel 1), I/O assignments 53 56 (network channel 2), I/O assignments 57 60 (network channel 3), I/O assignments 61 64 (network channel 4) I/O Point Assignments (Analog outputs) The 68-6207 module is equipped with two (2) analog outputs. When it is used as an HT module, the analog outputs are assigned I/O points following the assignments of any A, B, E/D or E combo modules that may be installed. Analog outputs on a HM module are allocated I/O point assignments following the I/O assignments of any HT modules installed. If there are no HT modules installed, the HM module I/O point assignments follow the output assignments of any A, B, E/D or E combo modules that are installed. Analog output I/O assignments of SV combo module(s) always are assigned after the I/O assignments of both the HT and HM modules. 52-0000-0019/Rev B Page 8 of 12

Configuration The I/O points (25 through 88) correspond to physical inputs from transmitters. The OMNI supports temperature, pressure, and DP type transmitters. I/O points associated with transmitters are similar to I/O points associated with process inputs. They have alarm limit settings and transducer fail override settings. The DP type transmitters have input scaling for use when stacking transmitters. The I/O points can also be used multiple times within the flow computers configuration. For example, I/O point 25 (in this example, a temperature transmitter) can be selected to be the I/O point for both Meter Run 1 Temperature and Meter Run 2 Temperature. The HT modules have four (4) point-to-point inputs per module. The HM modules have four (4) networks that can be configured for point-to-point, multivariable, or multi-drop. If a network is configured for point-topoint, only one (1) input is available for use on that network. Four (4) inputs are available for networks configured as multivariable or multi-drop. Transmitter Configuration Each device used with the OMNI must first be configured using the Handheld Communicator to work properly. Poll Address - The poll address is a numerical short address used to identify a field transmitter device and to enable or disable the analog portion of the output signal. transmitters are discovered by the OMNI on the network using this poll address. The OMNI searches addresses 0-15 for point-to-point and multivariable transmitters. The IDs for transmitters that are multi-dropped must be preconfigured to 1-4. When this address is set to a non-zero value, this indicates that the device is intended for use in a multi-drop configuration with its output current parked at 4 ma. If the 4-20 ma device output current will be utilized, the poll address must be set to zero (the device is then said to be unparked). Unparked devices can only used in point-to-point or multivariable network configurations. Burst Mode This mode must be off for use with the OMNI. If the burst mode is detected to be on by the OMNI it will automatically be turned off by the OMNI. These configuration data points as well as many others are viewed and modified using a second master device, usually a handheld communicator. The handheld communicator device acts as a secondary master that can coexist on a network loop with an OMNI 3000/6000 Flow Computer. Typically the probe leads of the handheld communicator are attached to the loop connections of a device present on a loop. Note that a device must be connected to an existing loop when using the handheld communicator because the communicator is not capable of powering the device. Using the handheld communicator, set the poll address of each device to a non-zero setting if the 4-20 ma current output is not required, i.e. when the device will be used in a multi-drop configuration. NOTES: The OMNI 3000/6000 does not support reading or writing of device configuration data items. Refer to the User s Manual for the handheld communicator for information on its use regarding the maintenance of the device poll address. OMNI Input Configuration If a transmitter or field device has been properly attached to the network channel terminals of an OMNI 68-6207 module and the poll address has been properly set in the network device(s), discovery of each device will commence for each device associated with a I/O input that has been assigned. The communications status indicates Discovery mode. Discovery mode is initiated when an input is assigned or reassigned, if an HM module s network is reconfigured to a different type, following a system reset, after a device response timeout, or if a Discovery command is issued (the Discovery command is a user initiated OMNICOM diagnostic function that forces all network inputs into Discovery mode for at least one cycle). Once the poll address is established, the OMNI 3000/6000 Flow Computer will begin acquisition of the device process variable(s) from each device that is assigned. When configuring the I/O point in the OMNI 3000/6000, the selected input type must match the device type (e.g. if the device is a temperature transmitter, then the selected input type should be configured as a temperature type). 52-0000-0019/Rev B Page 9 of 12

When an HM module network channel is configured with more than one multi-dropped device, the OMNI 3000/6000 Flow Computer will acquire the primary variable of each device in turn. For example, if there are three (3) devices multi-dropped on a given HM module channel labeled A, B and C, then acquisition of the primary variable from each device will proceed as follows: A-B-C-A-B-C-A etc. The OMNI will acquire up to four (4) variables (PV, SV, TV and QV) from a multi-variable device on an HM module network. If a device only supports a subset of the variable set (i.e. PV and SV only), the inputs mapped to the unavailable inputs will indicate a communications status of "No Data". NOTES: The indicator LEDs for each network channel will indicate activity on that channel. The RED LEDs (RTS & TX) will illuminate when a message to a device is being transmitted to the network channel. Responses from field devices are indicated by the GREEN LEDs (CD & RX) activity. Reference the section titled Diagnostics and Figures 1 and 2. The protocol is designed to allow a maximum of two master devices on any network channel. When a second master is attached to the channel (typically the handheld communicator), the network channel is shared with the other master. If the other master is actively communicating with devices on a network channel, the OMNI 3000/6000 Flow Computer will alternate use of the network channel with the other master. The RED LEDs will illuminate only when the flow computer is transmitting a message on the channel. Device responses to each master device will illuminate the GREEN LEDs. If a field transmitter on a network loop is determined to be in Burst mode, the OMNI 3000/6000 Flow Computer will automatically send a command to that transmitter to exit burst mode. The bursting transmitter must have been discovered and identified before this can occur (therefore the bursting device must be assigned). Configuration Example: This example configuration will setup a system with one (1) HT module and one (1) HM module installed in an OMNI 3000/6000 Flow Computer. A temperature transmitter device is attached to network 1 of the HT module and a pressure transmitter device is attached to network 2 of the same module. One temperature transmitter and one DP transmitter are multi-dropped on network 1 of the HM module. From the discussion in the section labeled I/O Point Assignments, we can determine how the networks are assigned I/O points. Note that network 1 of the HM module is configured as multi-drop and assigned four (4) inputs. Since only two (2) devices are attached to that channel, any two (2) of the four (4) inputs may be utilized. In this example, inputs 29 & 30 are used (Table 2). HT Module Table 2. Inputs 29 & 30 HM Module Network 1 2 3 4 1 2 3 4 Input(s) 25 26 29 32 (29 & 30 used) Using the handheld communicator, set the poll address of device for input 29 as 1 and the poll address of the device for input 30 as 2. Assign the inputs shown above as desired. For example, assign input 25 to meter run 1 temperature, input 26 to meter run 1 pressure, input 29 to meter run 2 temperature and input 30 to meter run 2 DP. Set the alarm limits and overrides for each input as required. Reference the next two (2) sections to learn how to display the status of each input on the front panel display and how related errors are recorded in the system alarm log. OMNI Input Status Display The input status display is accessed on the flow computer front panel by entering the following key sequence (Display mode only). [Input] [Status] [Enter] or [Status] [Input] [Enter] The status display for input 25 will initially be displayed. All available inputs are accessed by scrolling the display using the [Up Arrow] and [Down Arrow] keys. (The number of available inputs will depend on the number and type of installed modules) 52-0000-0019/Rev B Page 10 of 12

The input status display for each input appears in Figure 8. Figure 8. Input Status Display The input number is shown and if there are communications with the device, the device s short tag is shown to the right of the input number. The CommStatus entry will present one of five possible status strings as follows: NotUsed - indicates that the given input is not assigned OK communications have been established and data is being acquired Error error while attempting communications with the device No Data indicates an unused input on a multivariable network Discovery the poll address is being determined The Device Status presents the field device status byte in hexadecimal format. The PV entry presents the current primary variable reading for the input. The PV Unit is the primary variable units configured in the device. NOTE: The configured device units are converted to the OMNI units before the value is used in the OMNI. We strongly suggest setting the device units to the same units used in the OMNI. Refer to the OMNICOM help file for a list of the unit conversion tables. Alarms and Error Messages The following are possible alarm log entries that may appear when a input is configured and assigned in the system. Mx ZZZZ Lost Communication Communication lost or reestablished to the field device. Mx ZZZZ Input mismatch Transmitter type mismatch - the unit code from a device does not match the assigned type (i.e. input assigned to a meter run temperature type when actual addressed device is not a temperature device). Mx ZZZZ Transducer Fail High The Field Device Malfunction bit (7) of the field device status byte became set. This byte is acquired from the device along with the primary variable value. Mx ZZZZ Transducer Fail Low The Primary variable outside of transmitter operation limits bit (1) of the field device status byte became set. This byte is acquired from the device along with the primary variable value. Where x = Meter run number (1 4) and ZZZZ = Input type (i.e. Temp, Pres, DP, etc.) Calibration The OMNI 3000/6000 does not directly support calibration of field devices. However, the OMNI 3000/6000 does offer a means to set an override value for use during a calibration sequence initiated by another network master (i.e. hand communicator). In addition, entering and exiting calibration mode at the front panel will log those events into the system audit log. Note that while a given field device may provide an override value of its own during its calibration sequence, it is recommended that the input be placed into and out of calibration mode at the front panel so that these calibration events will be recorded in the flow computer s audit log. 52-0000-0019/Rev B Page 11 of 12

DOCUMENT REVISION HISTORY DOCUMENT INITIAL RELEASE DATE... 23-September-2009 REVISION DATE PURPOSE / CHANGE REQUEST A 23-September-2009 DCR 090268 - Initial release B 04-January-2011 DCR 110202 52-0000-0019/Rev B Page 12 of 12