DPM-3221 Digital DC Power Meter with data logging capability.

Similar documents
DPM Digital DC Power Meter with Data logging capability. User Manual

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

MT-150. RENOGY 150A Peak High Precision Watt Meter and Power Analyzer E. Philadelphia St., Ontario CA Version: 1.

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Metiri Scientific COUMET60100SB Metiri Hobbyist COUMET60100HB Smart Energy Meter

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

IIM Warwick Court. Williamsburg VA REV 5

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

is then retained absolutely without interruption.

Sensacell Troubleshooting Guide

Gigabit inline PoE tester and detector

Visit to download the software Digalox Manager. Package contents: Panel meter Digalox DPM72, 5 jumpers, 1 mounting bracket

I. PANEL DESCRIPTION... 1

600 g x 0.02 g DIGITAL BALANCE

GSM HOME SECURITY SYSTEM

RS Stock No Instruction Manual RS Input Data Logging Thermometer

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

ECM-1220 User s Manual

ACT-1B Series Panel Tachometer

SY021 Portable Load/Force Meter User instructions

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

BC-7000 Field Calibration Procedure 55 AMP

Energy Meter and. Current Transducer. Assembly Manual

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

CONTENTS 1. SAFETY INFORMATION SPECIFICATION PARTS & CONTROLS General Specification Electrical Specification...

Billion SG3030S. Billion SG3030. Three-phase Power Meter Series. Three-phase ZigBee Power Meter. Three-phase RS485 Power Meter.

Series 3000 User Manual and Product Features

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

UNIVERSAL CURRENT CONVERTER

PADPULS2 M-BUS Pulse Input Modules

3700 SERIES USER MANUAL

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

M4-ATX-HV 6-34V Intelligent ATX Power Supply

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

407B 1/16 DIN Multi-Mode Timer

Digital Keypad Introduction

Harbortronics Time-Lapse Package Troubleshooting Guide This document is intended to help diagnose any problems with your Time-Lapse Package.

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers

Absolute Encoders Multiturn

BC-5000 Field Calibration Procedure 55 AMP

VERSION 1.1 SEPTEMBER 12, 2017 ULTIMATE POWERBOX PRODUCT MANUAL BY PEGASUS ASTRO [COMPANY ADDRESS]

Lightning Stitch Assembly

Ethernet to Digital I/O +RS232 +Switch

Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism.

Blue Point Engineering

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Installation of advanced communications board and LG Chem RESU

Multifunction Calibrator

Technical Specificaions. kwh Energy Meter

User Manual. cmt-svr Startup Guide

UK +44 (0) // USA // JAPAN //

UK +44 (0) // USA // JAPAN //

E600 VX01 Installation guide

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

7511 / / / 711 / / 731 / Preset 27

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

LVX Control Unit. Features:

MTP INSTRUCTION MANUAL

CPC 01/02. Description. x86 Computer Module. Datasheet

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC REGULATED POWER SUPPLIES SDP / 3636 / User Manual

HCS-3200/3202/3204 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Energy Management System. Operation and Installation Manual

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

Barefoot Power Ltd 2013 v1.4

Process displays For current and voltage

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

Installation of the PCMeasure Movement Sensor (30114)

Vibration Meter SD Card real-time datalogger

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

EnerSure Installation Guide

Datalogging Hot Wire CFM Anemometer

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

405A Timer with Instantaneous Relay

Environdata FA ma Converter Guide

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

Pen Drive USB Datalogger!

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

OT EASY 60 II. LED control unit Operating instructions

AirCare General Purpose ModBus Interface ACM1001. OptiDrive Modbus Module Product Specification. For assistance call

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

SMK525 / SMK585 / SMK595

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

Products no longer available

BRAND ELECTRONICS DIGITAL POWER METER MODEL

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

Transcription:

Introduction DPM-3221 Digital DC Power Meter with data logging capability. User Manual As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-200 A with the correct shunt), Watts, and it also displays the Amp-hour, Watt-hour, Watts Max, the total running time, the maximum & minimum values of voltage and current during the measuring period. The power meter can either be powered by the input (source) or the output (load) which ever has a minimum 5V DC. The Power Meter can also be powered by an external DC voltage of 5 to 60V DC if DC voltage range of 0-60V is desired. Once the Power Meter is powered up, it starts to data logged Amp hour, Watthour, Max. & Min. Voltage & Current values selectable interval from 30 seconds to 3 minutes. Up to 1,500 sets of Voltage and Current are stored in the Power Meter Memory (EEPROM) even when the Power Meter is off power. The data can be retrieved by a PC using our optional Data adapter and software program. The Power Meter has a magnetic back and a clip on mounting bracket. Precaution Do not exceed 60V DC or the rated value of external shunt in the application. This meter is designed and made for indoor use only. Do not dis-assemble or attempt to repair the power meter. If Start-up screen does not appear when power up, immediate remove the power sources. Double check for correct polarity. If either input or output connection is in wrong polarity, there will be no display on LCD. Damage to the Power Meter may result if wrong polarity power is applied. Do not exert pressure on the display to avoid damage to LCD display.

Controls and Indicators 1. LCD display 2. Shunt connect flat cable with phone plug 3. External Power Jack: for external power source (5-60V DC) to extend measured voltage to 0-60V DC from 5-60V. Pin: 5V / GND / RC 5V = Positive 5v to 60v external DC power source. GND = Negative of external DC power source RC = This is for changing the Shunt Rating setting. 4. Data Jack: for connection to optional Data adapter. 5. Reset button: a. To clear previous saved data. b. To change the Shunt Rating setting.

Wiring Diagram PIN Function Description 1 C- SENSOR - 2 C+ SENSOR + 3 NC No Connection 4 NC No Connection 5 V+ Voltage + 6 GND Voltage -

Using the DC Power Meter 1. Checking LCD and the shunt rating of DPM Before wiring the DPM with the external shunt, it is advisable to check the DPM by powering it up with any of the following methods. Use a 9V battery or any DC source of 5V to 60V to connect: a. the external power jack (3) 5v and GDN. b. the Load side ( +, -) see wiring diagram. c. the Source side (+, -) see wiring diagram. When powered up, the LCD displays first shows the firmware version and then factory preset data port mode as below. Diagram software version Diagram Shunt rating Diagram Sampling time After the above three displays disappear, the normal display will be shown. The V, A, and W will appear continuously while the bottom left quadrant displays all other data in a cyclic order at 2 to 3 second interval. The unit is then confirmed to be in good working order. If there is no display, check for reverse polarity or if the applied dc power is less than 5V. Diagram showing normal operation

Setting the shunt rating of the DPM to match your shunt If you want to change the DPM shunt rating to match your shunt, proceed as following: 1. After checking the DPM is in good order, plug in the supplied external power plug. 2. Unplug the shunt phone jack half way such that the LCD display disappears. 3. Press and hold the reset button and re-insert the shunt phone jack again at the same time until the LCD display is on again. 4. The LCD will show the present shunt setting See fig.1 5. Release the reset button. The LCD will display USB. see fig 2 6. Make a quick contact of the black and white wires from the external power wires to enter the setting mode of shunt type. The LCD will show as in fig 3 7. Quick press on the Reset Button will cycle the setting from 50A to 100 A to 200A. 8. Making a quick contact of the black and white wires will confirm your new shunt setting and the LCD should show normal operation display. See fig 4 9. Unplug and replug the phone jack to check if your new shunt setting has been successful. FIG.1 FIG.2 FIG.3 FIG.4

Remarks: If at step 3, the reset button is pressed for a longer time than 5 seconds, the DPM will enter into selection of communication mode then all the steps 4, 5, 6, 7, 8 will be for selection of USB->RS232->RS->485->USB. However at present only USB is available all other communication modes are for future development. Setting data logging time interval (with firmware version 2.0 or above) 1. DPM will display Sampling time setting after External Shunt rating display. To enter sampling time setup mode, PRESS and HOLD RESET button within 5 second while Sampling time showing. 2. The sampling time can be set as integer second between 30s and 180s. It start setup from most left-hand side digit. The digit under setting is keep flashing. 3. Short press of RESET button to change value in the digit. 4. PRESS and HOLD the RESET button to confirm number in digit. It show OK then go to next digit. 5. Repeat step 3 and step 4 to set all digit. 6. After setup all three digits, it will display a Y for you to confirm.

7. In case it is need to setup the number again, press RESET button to change Y to N. Then PRESS and HOLD RESET button to restart setup from most left-hand side digit. 8. In case the setting is collect, then PRESS and HOLD RESET button to confirm the value. It will show OK to confirm sampling time setting. Then the DPM go to operation mode. DISPLAYS A. On the first power up the display shows the firmware version and factory preset data port mode. Then quickly shows the preset shunt rating of the DPM. B. The Sampling time C. Measured Data Displays Scrolling Display

D. The Volts, Amps and Watts are continuously shown, all other data is shown in the scrolling display at 3sec. interval, any one of the scrolling displays can be held (and released) by a quick press of the Reset button(5) 1. Current (Amps A, Peak Amps Ap, MIN. Amps): The Amps value is the average current through the Meter's shunt over the last screen update interval. Ap is the Peak (maximum) current to the LOAD side, since the startup screen to the present moment. Similarly for Am which is the minimum current. 2. Voltage (Volts V, Maximum Voltage Vp, Minimum Voltage Vm): The Volts value is the average voltage over the last screen update interval. Vp is the Peak (maximum) voltage from the source side since startup screen to the present moment. Similarly for Vm (minimum) which is the voltage dip on the source side since startup. 3. Charge (Amp-hours Ah): The value displayed is the total charge in Amp-hours delivered to the LOAD since startup synchronized with the internal clock of the MCU. 4. Energy (Watt-hours Wh): The value displayed is the total energy delivered to the LOAD in Watt-hours since start up. 5. Power (Watts W, Peak Watts Wp): The value displayed is the average power delivered. The displayed Peak Watts value (Wp) is the maximum power drawn on the LOAD side, since the startup. Display duration time after power ON. When the unit is connected, it will count the duration time until disconnect.

Deleting the stored data There are two ways to clear all the previous stored data. 1. Press the Reset Button twice allowing 5 seconds for second press. 2. Use the external power source connections, connect the remote I/O black wire to source s negative terminal for 3 seconds and then release. It will clear previous data record.

Specifications Model DPM-3221(For use with external shunt) Measured Parameters 50A/50mV 100A/50mV 200A/50mV Current Range Amp 0-50A cont. 0-100A cont. 0-200A cont. Voltage Range Volt. Power Watt(W) 5~60V or 0~60V with external DC source Max. record W:12,000W Resolution of W:0.1W for W<10,000 1W for W>10,000 Resolution of V&I 0.01V,0.01A 0.01V,0.02A 0.01V,0.05A Scrolling Display of Registered Parameter Ampere Hour(AH) Peak Watt (Wp) registered Energy: Kilo Watt Hour (KWH) Max. recorded AH: 99,999AH Resolution of AH: 0.01AH for total recorded AH <1,000AH 0.1AH for 10,000 > total recorded AH > 1,000AH 1AH for total recorded AH > 10,000AH 12000W 0-9999.9KWH, Resolution 0.1KWH Registered Peak Voltage (Vp), The new high and low values of voltage and current will replace Min. Voltage (Vm),Peak Current the old ones during the metering period and registered at the (Ap), Min. Current (Am) Peak finish of the metering period Watt(Ap) Accumulative Max. Operation Period logged Scrolling speed on LCD Data Logging Interval Operation Voltage and Current External DC Source Range Operation Condition 75Hours 3 seconds for one parameter Selectable from 30s to 180s 5 ~ 60V and 12mA 5 ~ 60V, 9mA ~ 12mA 0 ~ 50 C, non-condensing humidity Storage Condition minus -10 C ~ 60 C Construction LCD Display Housing Material VA= 54mm x 14.4mm, 16 character x 2 row STN 5*8 dots Polycarbonate Dimension & Weight Supplied Accessories Optional Accessories Approvals 75(L) x 45(W) x 23(D) mm 100g Approx. Snap-on mounter & external power wire with plug, phone cable with RJ-11 plug, Inline coupler connector. 1.Data adapter module & software for data logging. 2.External DC power box w/ socket (battery not included). 3.External shunt modules with RJ-11 socket & 5 M phone cable with plugs. CE EN 61326, FCC 7673-3221-0564 REV.4 2014/03