IELR Rail-Mount Series Magnetic Circuit Protectors

Similar documents
IELR Series

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

IELR Rail-Mount Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG

Single Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

D-Series. Circuit Breaker

PERCENT OF RATED CURRENT

IAR/IUR/IER/CUR/CER Series 1RU Magnetic Circuit Protectors

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Time Delay Values (E-Series)

E-Series General Specifications

209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS

C-Series. Circuit Breaker

D-Series CIRCUIT BREAKER

C-Series. Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker

9926 Series Branch Rated Circuit Breakers AC Version

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Thermal-Magnetic Circuit Breaker 2216-S

Introduction Circuit Protection

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Model Number Structure

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

E-Series General Specifications

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

TeSys IEC Contactors and Overload Relays

Introduction Electronic Circuit Protection ESX10-T

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Miniature Circuit Breakers for Railway Applications

UL 489 DIN rail branch circuit breakers

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Applying branch circuit breakers and supplementary protectors in North America

Table of Contents. 1 General 1.1 Scope

Bulletin 1489 Circuit Breakers. Selection Guide

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

The International Power Quality Resource

Applying branch circuit breakers and supplementary protectors in North America

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

W69-X2Q12-20 Product Details

Miniature Circuit Breakers and Supplementary Protectors. Contents

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

RL Line/Load Reactors

Bulletin 817 Thermistor Protection Relay

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

TeSys protection components

Switching Power Supply

PD-Series General Specifications

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Section 4 Ground-Fault Protection Devices

SPECIFICATION. SFX Form Factor. SST-ST45SF 450W Switching Power Supply Active PFC Circuit Full Range Input. SFX Form Factor

60103 Circuit Breaker

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

IAG/IUG/IEG/CEG/LEG Single Pole Circuit Protectors 91. IAG/IUG/IEG/CEG/LEG Multi-Pole Circuit Protectors 92

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

120 WATT FLEX ATX TYPE WITH ACTIVE PFC

1492-SP Supplementary Protectors

Voltage Current Front-mounting bracket

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

SRT2-ROC08, SRT2-ROC16

Model Number Structure

WMS SUPPLEMENTARY PROTECTORS

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Model Number Structure

Model Number Structure

Model Number Structure

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

PRODUCT SPECIFICATION

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Switching Power Supply

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable


W91-X Product Details

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

2.3 Power Supply Module PS 307; 5 A; (6ES7307-1EAx0-0AA0)

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Solid State Relays with Failure Detection Function

20A DRR Module / 40A DRR Module

V REG.-Nr. 3919, Z E214024

Thermal-Magnetic Circuit Breaker 4220-T...

D2SW-3L1HS D2SW-01L1HS

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

Transcription:

IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200

IELR Series Hydraulic Magnetic Circuit Protectors INTRODUCTION Designed specifically for the 35mm symmetrical DIN rail, Airpax IALHR, IULHR and IELHR series Rail-Mount Magnetic circuit protectors offer the advantages of quick and easy mounting or removal which results in efficient and economical wiring, while conserving space. These circuit protectors are available in, 2, 3 and 4 pole models, with a choice of handle colors with on/off and international I/O markings. These protectors comply with UL and CSA standards and meet IEC and VDE spacing requirements. Typical applications include computers and peripherals, telecommunications, medical equipment, machine tools and process control instrumentation. They provide the reliable performance associated with magnetic circuit protection. Mounting - These circuit protectors are designed to mount on standard 35mm DIN rails, such as 35x7.5 or 35x5 per DIN EN50022. Other specialty rails are available from suppliers that provide a means of mounting non DIN mount components by means of special captive jam nuts. 92 IELR Series - Introduction http://airpax.sensata.com/

Single Pole IELR Rail-Mount.236 [5.99].929 [49.00].38 [3.5] DIM. A.689 [7.50].689 [7.50].83 [4.65] 3.622 [92.00].680 [42.67].22 [28.50].47 [35.99] 2.500 [63.50] ON OFF I O.437 [36.50] 2.059 [52.30] MOUNTING CLIP 2 X 6-32 THREAD M3 X 0.5-6H THREAD OPTIONAL.42 [3.6] DEEP (TYP.).240 [3.50] M5 SCREW Two Pole.236 [5.99].929 [49.00].38 [3.5] DIM. A.689 [7.50].689 [7.50].83 [4.65] 3.622 [92.00].680 [42.67].22 [28.50].47 [35.99] 2.500 [63.50] ON I ON I OFF O OFF O.437 [36.50] 2.059 [52.30] ALL MULTI-POLE CONFIGURATIONS USE TWO MOUNTING CLIPS.240 [3.50] 4 X 6-32 THREAD M3 X 0.5-6H THREAD OPTIONAL.42 [3.6] DEEP (TYP.).748 [9.00] Note: Tolerance ±.05 [.38] unless noted. Dimensions in brackets [ ] are millimeters. Multi-Pole Dimensions - DIM A pole.750 ±.02 [9.05 ±.5] max 2 pole.55 [38.48] max 3 pole 2.265 [57.53] max 4 pole 3.05 [76.58] max Note: Dimension A varies with # of poles http://airpax.sensata.com/ IELR Series - Single Pole 93

IELR Specifications Series Trip The most popular configuration for magnetic protectors is the series trip where the sensing coil and contacts are in series with the load being protected. The handle position conveniently indicates circuit status. In addition to providing conventional overcurrent protection, it s simultaneously used as an on-off switch. Switch Only In the event that over-current protection is not desired, the coil mechanism can be deleted, providing an excellent low cost, single or multi-pole power switch. Insulation Resistance 00 megohm minimum at 500Vdc between all electrically isolated terminals. Dielectric Strength 3750Vac (3750V~) shall withstand AC voltages 50/60Hz for 60 seconds between all electrically isolated terminals. Endurance Circuit breakers shall operate a minimum of 0,000 operations; 6,000 with rated current and voltage and 4,000 with no load. Operating Temperature 40 C to +85 C. Series Switch Only LINE LOAD IEC 44 Classification Type handle spacings IP40. Terminals IP00. Moisture Resistance 0 days, 95 percent relative humidity at 40 C in accordance with IEC68-2-3, test C. Three Pole Schematic Diagram Salt Spray Five percent solution at 35 C in accordance with IEC68-2-, test K, 48 hours. Shock 50g, m sec, half sine with rated current, except no current with handle down. Instantaneous units use 80 percent rated current. Test in accordance with IEC68-2-27, test Ea. This assumes that adequate end stops are used to prevent longitudinal movement of the circuit protector. t=f (I) Vibration 4g, 5 500Hz (maximum double amplitude displacement.5mm) with rated current except no current with handle down. Instantaneous units use 80 percent rated current, in accordance with IEC68-2-6, test F, method A, one hour per plane. This assumes that adequate end stops will be used to prevent longitudinal movement of the circuit protector. 94 IELR Series - Specifications http://airpax.sensata.com/

IELR OPERATING CHARACTERiSTICS IELR Rail-Mount APL/UPL - Nominal DCR / IMPEDANCE Current Ratings (Amps) Resistance (ohms) Impedance (ohms) Impedance (ohms) DC Delays AC, 50/60Hz Delays AC, 400Hz Delays 5, 52, 53, 59 6, 62, 63, 69 4, 42, 43, 49 0.20 45.8 28.5 7.94.0.38.0 2.85 5.0.37.29.76 0.0.055.05.2 5.0.07.06.032 20.0.006.006.00 30.0.003.004.006 50.0.009.008.009 60.0.0057.0034 70.0.0047.0033 Notes: DCR and impedance based on 00% rated current applied and stabilized for a minimum of one hour. Tolerance.05-2.5 amperes ± 20%; 2.6-20 amperes ± 25%; 2-70 amperes ± 50%. Consult factory for special values and for coil impedance of delays not shown. Inrush Pulse Tolerance Pulse tolerance is defined as a single pulse of half sine wave 50/60Hz peak current amplitude of 8 milliseconds duration that will not trip the circuit breaker. PULSE TOLERANCES Delay Pulse Tolerance 6, 62, 63 (. to 70 amps) 2 times (approx.) rated current 6F, 62F, 63F (. to 25 amps) 20 times (approx.) rated current 6F, 62F, 63F (25. to 70 amps) 8 times (approx.) rated current Percentage of Rated Current vs Trip Time in Seconds at +25 C Delay 00% 25% (Note A) 50% 200% 400% 600% 800% 000% 4 No Trip May trip.5 to 8.5 to.9.02 to 4.006 to.25.004 to..004 to.05 42 No Trip May trip 5 to 70 2.2 to 25.40 to 5.02 to 2.006 to.2.006 to.5 43 No Trip May trip 35 to 350 2 to 20.5 to 20.02 to 2.2.0 to.22.0 to. 49 No Trip May trip.00 max..050 max..020 max..020 max..020 max..020 max. 5 No Trip.5 to 6.5.3 to 3. to.2.03 to.5.0 to.25.004 to..004 to.08 52 No Trip 2 to 60.8 to 30 to 0.5 to 2.04 to.008 to.5.006 to. 53 No Trip 80 to 700 40 to 400 5 to 50 2 to 20.23 to 9.08 to.55.02 to.2 59 No Trip.20 max..00 max..050 max..022 max..07 max..07 max..07 max. 6 No Trip.7 to 2.35 to 7.30 to 3.030 to.05 to.3.0 to.5.008 to. 62 No Trip 0 to 20 6 to 60 2 to 20.2 to 3.02 to 2.05 to.8.0 to.25 63 No Trip 50 to 700 30 to 400 0 to 50.5 to 20.4 to 0.03 to.85.03 to.5 69 No Trip.20 max..00 max..050 max..022 max..07 max..07 max..07 max. 7 No Trip.44 to 0.3 to 7. to 3.03 to.02 to.3.004 to.5.004 to. 72 No Trip.8 to 00.7 to 60 to 20.5 to 3.04 to 2.008 to.79.006 to.28 73 No Trip 50 to 600 30 to 400 0 to 50.8 to 20.22 to 0.8 to.88.0 to.5 79 No Trip.20 max..00 max..050 max..023 max..06 max..05 max..05 max. Notes: All trip times and trip currents are specified with the protector mounted in the normal vertical position at ambient temperature of 25 C. Protectors do not carry current prior to application of overload. A: 35% for delays 7, 72, 73 and 79. http://airpax.sensata.com/ IELR Series - Operating Characteristics 95

IELR DELAY CURVES 400Hz, DC, 50/60Hz Delay Curves (typ) A choice of delays is offered for DC, 50/60Hz, 400Hz, or combined DC/50/60Hz applications. Delays 49, 59, 69 and 79 provide fast acting, instantaneous tripping and are often used to protect sensitive electronic equipment (not recommended where a known inrush exists). Delays 4, 5, 6 and 7 have a short delay for general purpose applications. Delays 42, 52, 62 and 72 are long enough for most transformers and capacitor loads. Delays 43, 53, 63 and 73 are extra long for special motor applications. 50/60Hz Delay Curves (typ) 0000 0000 000 DELAY 6 000 DELAY 63 00 0 00 0...0.0.00 0 00 25 50 200 300 400 500 600 700 800 900 000.00 0 00 25 50 200 300 400 500 600 700 800 900 000 0000 0000 000 DELAY 62 000 DELAY 69 00 0 00 0...0.0.00 0 00 25 50 200 300 400 500 600 700 800 900 000.00 0 00 25 50 200 300 400 500 600 700 800 900 000 96 IELR Series - Delay Curves http://airpax.sensata.com/

IELR Rail-Mount DC Delay Curves (typ) 0000 0000 000 DELAY 5 000 DELAY 53 00 0 00 0...0.0.00 0 00 25 50 200 300 400 500 600 700 800 900 000.00 0 00 25 50 200 300 400 500 600 700 800 900 000 0000 0000 000 00 0 DELAY 52 000 00 0 DELAY 59...0.0.00 0 00 25 50 200 300 400 500 600 700 800 900 000.00 0 00 25 50 200 300 400 500 600 700 800 900 000 http://airpax.sensata.com/ IELR Series - Delay Curves 97

DC/50/60Hz Delay Curves (typ) (Multi-Frequency) 0000 0000 000 00 DELAY 7 DC/50/60 Hz Short Delay 000 00 DELAY 73 DC/50/60 Hz Motor Start Delay 0 0...0.0.00 0 00 35 50 200 300 400 500 600 700 800 900 000.00 0 00 35 50 200 300 400 500 600 700 800 900 000 0000 0000 000 00 DELAY 72 DC/50/60 Hz Long Delay 000 00 DELAY 79 DC/50/50 Hz 35% Instant Trip 0 0...0.0.00 0 00 35 50 200 300 400 500 600 700 800 900 000.00 0 00 35 50 200 300 400 500 600 700 800 900 000 98 IELR Series - Delay Curves http://airpax.sensata.com/

400Hz Delay Curves (typ) IELR Rail-Mount 0000 0000 000 DELAY 4 000 DELAY 43 00 00 0 0...0.0.00 0 00 25 50 200 300 400 500 600 700 800 900 000.00 0 00 25 50200 300 400 500 600 700 800 900 000 0000 0000 000 00 DELAY 42 000 DELAY 49 00 0 0...0.0.00 0 00 25 50 200 300 400 500 600 700 800 900 000.00 0 00 25 50 200 300 400 500 600 700 800 900 000 http://airpax.sensata.com/ IELR Series - Delay Curves 99

AGENCY APPROVALS Voltage (Volts) Rated Current (Amps) Interrupting Capacity, Amps Max Voltage Frequency (Hz) Phase Min Poles UL/CSA VDE UL077 & CSA VDE 80 DC.05 to 50.0-50 7500 4000 80 DC.05 to 70 7500 80 DC.05 to 00 0000 250 50/60 & 3.05 to 50.0-50 3500 2000 250 50/60 & 3.05 to 70 2000 250 50/60 & 3.05 to 50 5000 () 250 50/60 & 3.05 to 70 5000 () 277 50/60.05 to 50 2000 277 50/60.05 to 50 5000 () 240/45 50/60 & 3 2.05 to 50.0-30 2000 2000 240/45 50/60 & 3 2.05 to 50 5000 () 277/480 50/60 3 2.05 to 30 2000 250 400 & 3.05 to 50 750 Note: () with 25A max series fuse. IELR DECISION TABLES How to Order The ordering code for IELR circuit protectors may be determined by following the steps in the decision tables shown here. The coding given permits a self-assigning part number, but with limitations. Using the illustrated coding system, it will automatically be assumed that all poles are identical. When all poles of a multi-pole protector are not identical, please contact an Airpax sales representative or the factory for a part number. One great virtue of magnetic circuit protectors is their adaptability to complex circuits. Thus, variations from pole to pole can become the rule rather than the exception. Descriptive drawings are recommended to avoid confusion. Notes: When poles are not identical, each pole is to be described and a special Airpax number will be assigned. Thomas & Betts (T&B) Narrow Tongue Lug P/N 556 is recommended for units rated above 50A. The T&B lug or an equivalent must be used on units rated 70A and above. When specifying a protector for AC motor start or high inrush applications, it is helpful to know the peak amplitude and surge duration for proper protector selection. 200 IELR Series - Approvals & Decision Tables http://airpax.sensata.com/

First Decision Type 5 Fifth Decision Rated Current IELR Rail-Mount IALHR One handle per pole (multi-pole only) Standard ratings listed. For other ratings, please contact the factory. IULHR One handle per pole (multi-pole only) UL Recognized, CSA Certified and VDE Approved ratings.00.250.500 0.0 5.0 20.0 IELHR IALR IULR IELR IMLR One handle per pole (multi-pole only) UL Recognized, CSA Certified and VDE Approved ratings One handle per unit One handle per unit UL Recognized and CSA Certified ratings One handle per unit UL Recognized, CSA Certified and VDE Approved ratings Mid-trip indication, One handle per unit Example: IELR - - 6-20.0-0 - V 2 3 4 5 7 6.750.0 2.5 5.0 7.5 Use three numbers to print required value between.050 amperes minimum and 70.0 amperes maximum. Sixth Decision Optional 30.0 35.0 40.0 50.0 60.0 70.0 IMLHR Mid-trip indication, One handle per pole Standard hardware. No designation necessary. 2 Second Decision Poles Single pole -A -C -D Metric thread mounting inserts 277V (50/60Hz only) 240/45V (50/60Hz only) Two pole Three pole Four pole 4 SW Fourth Decision Frequency & Delay Switch Only 7 Seventh Decision Handle Color Selection Unmarked 3-0 Third Decision Configuration Switch only (Omit 4th decision) -4-42 -43-49 400Hz short delay 400Hz long delay 400Hz motor start 400Hz 50% instant trip -00-0 -20-30 Black Yellow Red Blue - Series -5 DC short delay -40 Green -52 DC long delay -60 Orange V = VDE Approved -53-59 DC motor start DC 25% instant trip -90 White Marked (Combination On - Off / I-O) The shaded areas denote VDE Approval options. This approval requires the addition of a V at the end of the part number. The V will be added to any part number formed entirely from shaded decisions. If non-shaded areas are selected, the unit will not be VDE approved, but other approvals still apply. -6-62 -63-69 50/60Hz short delay 50/60Hz long delay 50/60Hz motor start 50/60Hz 25% instant trip -0 - -2-3 Black with white markings Yellow with black markings Red with white markings Blue with white markings -7 DC/50/60 Hz short delay -4 Green with white markings -72 DC/50/60 Hz long delay -6 Orange with black markings -73-79 DC/50/60 Hz motor start DC/50/60 Hz 35% instant trip -9 (Std.) White with black markings For addition of inertial delay, add an F to any delay numeral.